Kaba Mauer Code-Combi K 82021 Mounting Instructions

Page 1
Mounting Instructions 82021 Code-Combi K
Lock mounting position
Bolt left
Bolt down
Bolt up
Bolt right
22,7
19,7
1 General
Use high quality alkaline/manganese monobloc batteries only. Low quality batteries may cause oxidation which results in a
functional failure of the lock..
Avoid residual crystalline moisture in the cabinet (e.g. from varnishing) to make sure that electrical contact areas are not
attacked.
Make sure that the ingress of dirt or detergents (e.g. remaining fillers or cold cleaners) is prevented.  Do not grease/oil the lock or key.  It is recommended, that unauthorized persons have no access to security sensitive parts of the lock, also the door of the
safe, where the lock is installed, is open.
2 Mounting instructions for lock and control unit
Any variation of the lock or key may result in functional trouble and must better not be done. All claims under guarantee and
warranty will expire in this case.
Lock fastening: Use of M6 steel socket head cap screws or BSW ¼" steel bolts. The length of engagement must
correspond to the applicable standards considering the thickness of the lock height (see Fig. 1).
Fig.1
Stand 17.02.2016
Seite 1 von 12
Page 2
Mounting Instructions 82021 Code-Combi K
O
1
0
O
8
,
5
O
1
0
O
1
2
59
40
60
59
40
100
97
35
23,5
30
Montageplatte
Fastening screws: minimum property class 4.8 and maximum property class 8.8.  Screws to be secured either by lock washer, flat spring, tooth lock washer, fan type lock washer considering the diameter
(d1) or to be cemented.
Screw tightening moment : minimum 5 Nm and maximum 6 Nm.  The bolt must be floating in installed condition.  Perfect function of the lock and of any additional connected or triggered systems (e.g. boltworks) must be warranted and
checked by specialists during installation of the lock.
The lock must be mounted in closed condition (bolt extended).  The opening (cable gland) in the door of the secure storage unit may not be greater than 100 sq mm (see mounting
diagrams on Page 5 and following).
The lock is designed for installation in secure storage units made of steel. Installation in storage units consisting of other
material e.g. plastic is not allowed.
Do not apply any kind of force (e.g. hammer blows) for screw fitting and adjustment of the lock.  Lock to be installed covered and so as to prevent opening by boring.  The square spindle must be inserted without jamming.  For installation and adjustment of the lock on the door, make sure that the square spindle can be inserted into the lock
without applying force and without jamming. This can be achieved by mounting the lock according to the following pattern of mounting holes (page 5 and following). For further lock dimensions please refer to the Kaba Mauer Catalogue Sheet.
Technical data:
Lift height of bolt 20 mm Bolt extension in locked-out condition: approx. 22 mm Bolt width: 40 mm; Bolt height: 9 mm The maximum allowable force acting on the key bolt in opposite direction to the direction of locking, the maximum locking
force and the lateral load acting on the bolt, correspond to 1 KN and should not exceed this value. Provision should be made design wise for bolt stoppers on both ends or for a bolt support.
The bolt was according to EN1300 with a permanent load of 2,5 N over 10.000 cycles tested. These load should not be
exceeded permanently.
The actuating torque on the spindle must not exceed 2.5 Nm. Fastening of the boltwork: via two M4 threads on the front end of the bolt head.
Fig. 2: Mounting plate measurements
Stand 17.02.2016
Seite 2 von 12
Page 3
Mounting Instructions 82021 Code-Combi K
Connecting cable
Door
Connecting sleeve
Cable cover Connecting cover
3 Assembly
Fig. 3: Exploded view 82021Code-Combi K
Fixing input unit.
Insert the input unit’s connecting cable through the door of the safe.
Care must be taken to ensure that the connecting cable is not damaged during installation. Neither the protective cable casing nor the wiring may be damaged as there would otherwise be a risk of short circuits occurring. The cable should be safeguarded against damage by means of protective casing or plastic tubing. Care should also be taken to ensure there are no kinks in the cable or that it is not crushed when it is fixed.
Adjust the plastic input unit and fix with screws. There are two possibilities of fixing the input unit:
1. From the inside of the door (see Fig. 4) with M4 countersunk screws or
2. From the outside of the door (see Fig. 5) with M4 cheese head screws Fig. 4: Fixing from the inner side of the door Fig. 5: Fixing from the outside of the door
Fix lock.
Insert the connecting plug in the lock’s socket. Adjust the lock and fix with screws.  Fit cable cover.
Insert operating shaft in the lock. Fit operating button on the operating shaft. Fit cover plate.
4 Final testing
After the fittings have been fixed the handle should be freely movable. When turned 30° the spring action should bring the
handle back into the original position.
The correct functioning of the lock is to be tested in accordance with the operating instructions.
Stand 17.02.2016
Seite 3 von 12
Page 4
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
Riegel oben
62
O
1
0
104,5 33,6
67
Cable-lead through
34
O
4
,
2
O
1
0
O
1
0
59
97 23,5
83,5
5 Assembly Diagrams
Stand 17.02.2016
Seite 4 von 12
Page 5
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
83,5
9723,5
34
59
O
1
0
O
1
0
Riegel links Knopf links
Cable-lead through
Riegel oben
62
O
1
0
104,5 33,6
67
Stand 17.02.2016
Seite 5 von 12
Page 6
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
Riegel oben
62
O
1
0
104,5 33,6
67
Riegel rechts Knopf rechts
O
4
,
2
83,5
23,597
O
1
0
O
1
0
59
34
Cable-lead through
Stand 17.02.2016
Seite 6 von 12
Page 7
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
33,6 104,5
O
1
0
62
67
83,5
9723,5
34
59
O
1
0
O
1
0
Riegel links Knopf links
Cable-lead through
Stand 17.02.2016
Seite 7 von 12
Page 8
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
Riegel rechts Knopf rechts
O
4
,
2
83,5
23,597
O
1
0
O
1
0
59
34
Riegel rechts Knopf rechts
O
4
,
2
83,5
23,597
O
1
0
O
1
0
59
34
33,6 104,5
O
1
0
62
67
Cable-lead through
Stand 17.02.2016
Seite 8 von 12
Page 9
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
90
23,5 97
59
O
1
0
O
1
0
O
4
,
2
Knopf unten
Cable-lead through
Riegel links
62
104,533,6
O
1
0
67
Stand 17.02.2016
Seite 9 von 12
Page 10
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
83,5
9723,5
34
59
O
1
0
O
1
0
Riegel links Knopf links
Cable-lead through
Riegel links
62
104,533,6
O
1
0
67
Stand 17.02.2016
Seite 10 von 12
Page 11
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
O
1
0
33,6104,5
62
Riegel rechts
67
90
23,5 97
59
O
1
0
O
1
0
O
4
,
2
Knopf unten
Cable-lead through
Stand 17.02.2016
Seite 11 von 12
Page 12
Mounting Instructions 82021 Code-Combi K
Installation position of lock
Installation position
of input unit
Hole dimensions of input unit
Screw fixing points for lock
Riegel rechts Knopf rechts
O
4
,
2
83,5
23,597
O
1
0
O
1
0
59
34
Cable-lead through
O
1
0
33,6104,5
62
Riegel rechts
67
Stand 17.02.2016
Seite 12 von 12