Kaba Mas LCLX, LCMX Operating Instructions Manual

LC SERIES
G
MODELS LCLX, LCMX
OPERATING INSTRUCTIONS
The following instructions cover lock operations for LC Series locks. The lock models are battery powered (PowerSaver instructions.
The Super Master Combination is a six-digit combination used to reset the lock to the factory default combination (50 25 50) in the event the user combination(s) are lost. See
the Super Master Operations sheet (P/N 394.101).
LOCK MODES
A maximum of two users can exist in a lock. A lock can operate in either Single Mode or Dual Custody Mode.
TM
technology). See back page for Battery Replacement
Single Mode
Single Mode defaults to having only a Manager User (User 1) in the lock. A second user (User 2) can then be added by the Manager User (User 1). (See section on Manager User Operations.)
In Single Mode only one valid user combination is required to open the lock - the Manager User (User 1) combination or the User 2 combination.
Note: Default lock status from the factory is Single Mode with an opening combination of “50 25 50” for the Manager User (User 1).
Dual Custody Mode E E
Dual Custody Mode defaults to two users in the lock - User 1 and User 2.
Both user combinations are required to open the lock - the User 1 combination and the User 2 combination.
Note: Manager User Operations are not available in Dual Custody Mode.
LOCK OPERATION & RESPONSES
• Each keystroke generates a green flash G with a beep
• To cancel entry, press
• The completion of a step within an operation is indicated by a green flash
E
88
8.
88
.
G
G
G
88
8.
88
G
88
8
88
88
8
88
with a beep
• The successful completion of an operation is indicated by two green flashes with beeps.
• An error is indicated by five green flashes with beeps.
G
88
8
88
• A low battery is indicated by 5 series of three green flashes with beeps
G
88
8
88
(See Battery Replacement on back page.)
88
8
88
G
88
8
88
G
88
8
88
G
88
8 after a lock opening.
88
G
88
8
88
88
8
88
OPEN/CLOSE THE CONTAINER
G
EE
1. For Single Mode
Enter Manager User (User 1) or User 2 combination.
For Dual Custody Mode
E
(Factory combination is “50 25 50”.)
EE
EE
E
EE
G
88
8
88
EE
E
EE
88
8
88
88
8
88
3 min. lockout
Enter User 1 or User 2 combination. G
Enter the second combination. G
Wrong Try Penalty: 5 wrong tries =
Each additional wrong try = 3 min. lockout
Green flashes with beeps G
2. Immediately rotate the container handle to retract bolt works before green
G
lights flash with beeps
container, close the door and rotate the container handle back to locked position.
CHANGE COMBINATION
WARNING: Super Master Control will be permanently lost if you do not change
the default Super Master Combination prior to changing any User combinations. See Super Master Operations sheet (P/N 388.105).
Caution: Before changing combination, open the container door to allow testing with the new combination. Record new combination and store it in a secure place.
1. For User 1 (Manager User in Single Mode)
Press
For User 2
. Press .
88
8 will occur during the lockout.
88
88
8. Open the container door. To close and lock the
88
G
88
8
88
88
8
88
88
8
88
88
8
88
88
8
88
88
8
88
88
8
88
G
G
G
88
8
88
88
8
88
88
8
88
G
88
8
88
G
88
8
88
Press . Press . G
2. Enter current combination. (Factory combination is “50 25 50”.) G
3. Enter new six-digit combination. G
4. Enter new combination again for verification.
5. Open the lock with the new combination before closing container.
CHANGE LOCK MODE (SINGLE / DUAL CUSTODY)
Note: Changing the lock mode will reset the combination(s) to “50 25 50”.
1. Press . Press . G
2. If changing from Single to Dual Custody Mode
Enter Manager User (User 1) combination.
If changing from Dual Custody to Single Mode Enter User 1 or User 2 combination.
Enter the second combination. G
Manager User Operations
These operations are only available in Single Mode and can only be performed by the Manager User (User 1). All Manager User Operations involve management of User 2.
User 2 can have a lock access status of “Enabled” or “Disabled”. If “Enabled”, User 2 can open the lock. When User 2 is added to the lock, the default lock access status is “Enabled”. The Manager User (User 1) has the authority to change the lock access status for User 2 and can temporarily “Disable” lock access for the user.
ADD USER 2
G
1. Press . Press .
88
8
88
2. Enter Manager User (User 1) combination.
Note: User 2 is added to the lock as “Enabled” with a factory combination of “50 25 50”.
User 2 can change the User 2 combination while Enabled, but only the Manager User (User 1) can change the lock access status.
DELETE USER 2
G
1. Press . Press .
2. Enter Manager User (User 1) combination.
ENABLE USER 2
1. Press . Press .
2. Enter Manager User (User 1) combination.
Note: If you try to enable User 2 when already enabled, you will get an error indication.
DISABLE USER 2
1. Press . Press .
2. Enter Manager User (User 1) combination. G
88
8
88
G
88
8
88
G
88
8
88
G
G
G
88
8
88
88
8
88
88
8
88
G
G
G
88
8
88
88
8
88
88
8
88
88
8
88
G
88
8
88
Note: If you try to disable User 2 when already disabled, you will get an error indication.
Battery Replacement
Read all instructions before attempting to replace the battery in an LC Series lock.
To replace the battery, you must
Figure 1
Insert Blade of
Screwdriver
Under Keypad
Housing
first remove the keypad assembly. To do so, insert the blade of a flat head screwdriver under the keypad housing at a point about 15 degrees to the right of 6 o’clock on the face of the keypad (below the Enter key). (See Figure 1.) There is a small indentation on the back edge of the keypad housing that will allow the screwdriver to easily be inserted at this point. Pry the keypad assembly from the face of the safe being careful not to damage the cable connection from the safe to the keypad assembly. (See Figure
2.)
Remove the old battery and
Figure 2
replace with a new 9-Volt battery. (See Figure 2.) Reattach
Battery
Cable Connection
the keypad being careful not to pinch the battery cable between the keypad housing and the mounting bracket.
Test the operation of the lock before closing the container. If the combination is entered successfully, one green flash
Battery Clip
displays to indicate the lock is ready to open. Then rotate the container handle to retract the bolt. If the test is successful, the lock and container are now ready for use.
Note: If the lock does not operate successfully, carefully remove the keypad, check the cable connection, and verify that all mounting screws are securely tightened.
Phone (800) 950-4744 or (859) 253-4744 FAX (859) 253-4748