Kaba E-Plex 3200, E-Plex 5200 Quick Reference Manual

Summary of Pushbutton Programming Commands
To begin, put lock in programming mode by pressing: #Master Code#
Quick Reference Guide
3200/5200
Kaba Access & Data Systems Americas 2941 Indiana Avenue Winston-Salem, NC 27105 USA Tel: (800) 849-8324 (336) 725-1331 Fax: (800) 346-9640 (336) 725-3269
www.kaba-asdamericas.com
Name Command
Description of Command Authorization
Configuration
000 # MMMMMMMM# MMMMMMMM#
‘Modify Master User Access Code (lock’s activation)’ (Always 8 digits)
Master
001# MMDDYY# MMYYDD#
‘Date Setup’ (MM = 01 to 12; DD = 01 to 31; YY = 00 to 99
002# HHMM# HHMM#
‘Time Setup’ (HH = 00 to 23; MM = 00 to 59)
Manual Passage
399 #
P#
‘Activate/De-Activate Passage Mode’ (P = 0 or 1; 0 = disable Passage Mode; 1 = enable Passage Mode)
Master, Mgr
Global Lockout
499 #
L#
‘Activate/De-Activate Lockout Mode’ (Master User not affected by Lockout Mode) (L = 0 or 1; 0 = disable Lockout Mode; 1 = enable Lockout Mode)
Master
Diagnostics
500 #
1234567890*#
‘Manual diagnostics’ Master, Mgr
501 # Identify if the lock is an
E-Plex™ 5000, 5200, 5700, or 5800
Communication Startup
900# ‘Communications startup’ Master, Mgr
Visual Feedback Message Definitions
Condition Parameters
Green LED Red LED Duration Rate
Valid pushbutton pressed
ON OFF 1/10 sec Once
Keypad OFF ON 1 sec Once
Valid access code keyed
ON OFF 1 sec Once
Access granted ON OFF 1/10 sec 1 sec; till end of unlock
out time
Access granted (battery low condition)
ON ON 1/10 sec 1 sec; till end of
unlockout time
Access denied OFF ON 1 sec Once
Valid programming entry
ON OFF 1 sec Once
Invalid programming entry (including duplicate access code)
OFF ON 1 sec Once
Tamper shutdown beginning
OFF ON 2 sec Once
Tamper shutdown state OFF ON 1 sec 10 sec; till end of
tamper shutdown time
Tamper shutdown ending
ON OFF 2 sec Once
Communication starting
ON OFF 1 sec Once
Communication ending
ON OFF 1 sec Once
Communication aborted
OFF ON 1 sec Once
Communication in progress
ON ON 1/10 sec 1 sec; till end of
communication with M-unit PDA
Lock model, no feedback
On (Alternate)
On (Alternate)
1/2 sec. Once
Deadbolt/Thumbturn Privacy Activated
OFF On
(Alternate)
1 sec. Once
Deadbolt/Thumbturn Privacy De-activated
On OFF 1 sec. Once
Hard reset sequence in progress
On (Alternate)
On (Alternate)
1/2 sec. 1/2 sec.; till end of
next sequence
End of successful hard reset
On OFF 2 sec. Once
End of unsuccessful hard reset
OFF On 2 sec. Once
PKG3116 0314
Loading...