K40 Calibre DL, Calibre DL-P, Calibre SL, Calibre SL-P, LD5500 Specifications

GROUND
#8 X 1/2" TEK
IGNITION SWITCHED +12 VOLTS
BLACK
RED
BLUE
GRAY
WHITE
GRAY
GRAY
WHITE
BLUE
INTERIOR
NETWORK
MODULE
FRONT RADAR
LED
REAR
RADAR
LED
(CALIBRE DL
model only)
FRONT LASER DEFUSER REAR LASER DEFUSER
YELLOW*
BROWN*
WHITE
BLACK
SILVER (NOT USED)
COPPER
COPPER
SILVER
CLEAR
ZIP CORD
BLACK
ZIP CORD
BLUE
YELLOW*
BROWN*
BLACK
SILVER (NOT USED)
COPPER
COPPER
SILVER
CLEAR
ZIP CORD
BLACK
ZIP CORD
RECEIVER
CABLE
RECEIVER
CABLE
FUSE
CONNECTION
FUSE
CONNECTION
GROUND
#8 X 1/2" TEK
GROUND
#8 X 1/2" TEK
(OPTIONAL)
(OPTIONAL)
1AMP
1AMP
FRONT
REAR
+12 VOLT BATTERY
OR IGNITION
SOURCE
+12 VOLT BATTERY
OR IGNITION
SOURCE
AMPLIFIED
SPEAKER
BLOCK DIAGRAM
*THE YELLOW AND BROWN
RADAR RECEIVER WIRES ARE USED TO CONNECT TO THE OPTIONAL LASER DEFUSER. IF NO LASER DEFUSER IS BEING INSTALLED WITH THE RADAR RECEIVER (FRONT AND/OR REAR), THE YEL­LOW AND BROWN WIRES WILL NOT BE USED.
CALIBRE
44586-1 4/06
IGNITION AND GROUND
1. Use a test meter to locate an ignition on source for the Interior Network Module with +12 volts when ignition key is both on and cranking.
2. Connect the black wire to a solid chassis ground using the provided ring terminal and silver self­tapping screw.
3. Radar receivers may be connected to either a +12 volt ignition on source or +12 volt constant battery source.
*NOTE: THE RED WIRE
SHOULD BE CONNECTED TO A MINIMUM 16 GAUGE +12 VOLT IGNITION WIRE.
GROUND
#8 X 1/2" TEK
IGNITION SWITCHED +12 VOLTS
BLACK
RED
BLUE
GRAY
WHITE
GRAY
GRAY
WHITE
BLUE
INTERIOR
NETWORK
MODULE
FRONT RADAR
pod
REAR
RADAR
pod
(CALIBRE DL-P
model only)
FRONT LASER DEFUSER REAR LASER DEFUSER
+12 VOLT
BATTERY
OR IGNITION
SOURCE
YELLOW*
BROWN*
WHITE
BLACK
SILVER (NOT USED)
COPPER
COPPER
SILVER
CLEAR
ZIP CORD
BLACK
ZIP CORD
+12 VOLT BATTERY
OR IGNITION
SOURCE
BLUE
YELLOW*
BROWN*
BLACK
SILVER (NOT USED)
COPPER
COPPER
SILVER
CLEAR
ZIP CORD
BLACK
ZIP CORD
RECEIVER
CABLE
RECEIVER
CABLE
FUSE
CONNECTION
FUSE
CONNECTION
1AMP
GROUND
#8 X 1/2" TEK
GROUND
#8 X 1/2" TEK
(
OPTIONAL
)
(OPTIONAL)
FRONT
REAR
1AMP
AMPLIFIED
SPEAKER
BLOCK DIAGRAM
IGNITION AND GROUND
1. Use a test meter to locate an ignition on source for the Interior Network Module with +12 volts when ignition key is both on and cranking.
2. Connect the black wire to a solid chassis ground using the provided ring terminal and silver self­tapping screw.
3. Radar receivers may be connected to either a +12 volt ignition on source or +12 volt constant battery source.
*THE YELLOW AND BROWN
RADAR RECEIVER WIRES ARE USED TO CONNECT TO THE OPTIONAL LASER DEFUSER(S). IF A LASER DEFUSER IS NOT BEING INSTALLED WITH A RADAR RECEIVER (FRONT AND/OR REAR), THE YELLOW AND BROWN WIRES WILL NOT BE USED.
CALIBRE
*NOTE: THE RED WIRE
SHOULD BE CONNECTED TO A MINIMUM 16 GAUGE +12 VOLT IGNITION WIRE.