Küppersbusch GMS 6540.0 E-UL, GMS 9551.0 E-UL, GMS9551.0E Instructions For Use Manual

COD. 04037ULKUP - 25.06.2009
Dear Customer, Thank you for having purchased one of our products. We are certain that this new, modern, functional and practical appliance, built with the very highest quality materials, will meet your requirements in the best possible way. This appliance is easy to use. It is, however, important to thoroughly read the instructions in this handbook in order to obtain the best results.
These instructions are only valid for the countries of destination, the identification symbols of which are indicated on the cover of the instruction manual and on the appliance itself. The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance.
The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors; the designs in the figures are purely indicative. The Manufacturer also reserves the right to make any modifications to the products as may be considered necessary or useful, also in the interests of the user, without jeopardizing the main functional and safety features of the products themselves.
INSTRUCTIONS AND ADVICE FOR THE
USE, INSTALLATION AND MAINTENANCE
OF MIXED AND GAS FUELLED
BUILT-IN HOT PLATES
MODELS: GMS 6540.0 E-UL - GMS 9551.0 E-UL
Kuppersbusch USA
1883 Massaro Blvd. Tampa, FL 33619
Toll: (800) 459-0844 P: 813-288-8890 F: 813-288-8604
DESCRIPTION OF HOBS
2
1 Ultra rapid gas burner 11000 Btu/h 2 Rapid gas burner 10000 Btu/h 3 Semirapid gas burner 6100 Btu/h 4 Semirapid gas burner 6100 Btu/h 5 Auxiliary gas burner 3550 Btu/h 6 Enamelled steel pan support 2F 7 Enamelled steel pan support central 8 Burner n° 1 control knob 9 Burner n° 2 control knob 10 Burner n° 3 control knob 11 Burner n° 4 control knob 12 Burner n° 5 control knob 13 Electric ignition button
Attention: this appliance has been manufactured for domestic use only and it employment by private person.
TYPES: GMS 6540.0 E - UL
TYPES: GMS 9551.0 E - UL
3
SAFE GUARD INSTRUCTIONS
1) SAFE GUARD INSTRUCTIONS
For all appliances:
- the product shall be installed according with the a statement that the installation must conform with local codes or, in absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- The product must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
- The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of ½ psi (3.5 kPa). The maximun gas supply pressure is 4 inch WC and 11 inch WC and the gas pressure regulator provided is regulated to 1 inch water column above the manufacturer’s specified manihold pressure.
- Always disconnect all cord connect appliances shall include instructions relative to location ot the wall receptacle and the warning to the user to disconnect the electrical supply before servicing the appliance.
- Save the orifices removed from the appliance for future use.
- When a flexible service cord of the grounding type is provided to connect the appliance to a line-voltage electrical supply, the instructions shall also include the intent of the warning statement specified in 1.29.12.
- The maximum depth cabinets installed above cooking tops be 13 in. (330 mm).
- Keeping appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
- Not obstructing the flow combustion and ventilation air.
WARNING: If the information on this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer; service agency or the gas supplier.
4
2) BURNERS
A diagram is screen-printed above each knob on the front panel. This diagram indicates to which burner the knob in question corresponds. After having opened the gas mains or gas bottle tap, light the burners as described below:
- manual ignition
Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position (large flame fig. 1), then place a lighted match near the burner.
- Electrical ignition
Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position (large flame fig. 1), then depress and release the ignition button “E”.
- Automatic electrical ignition
Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position (large flame fig. 1), then depress the knob.
- Lighting burners equipped with flame failure device
The knobs of burners equipped with flame failure device must be turned in an anticlockwise direction until they reach the full on position (large flame fig. 1) and come to a stop. Now depress the knob in qu estion and re peat the prev iously indicated operations. Keep the knob depressed for about 10 seconds once the burner has ignited.
HOW TO USE THE BURNERS
Bear in mind the following indications in order to achieve maximum efficiency with the least possible gas consumption:
- use adequate pans for each burner (consult the following table and fig. 2).
- When the pan comes to the boil, set the knob to the reduced rate position (small flame fig. 1).
- Always place a lid on the pans.
- Use only pan with a flat bottom.
WARNINGS:
- burners with flame failure device may only be ignited when the relative knob has been set to the Full on position (large flame fig. 1).
- Matches can be used to ignite the burners in a blackout.
- Never leave the appliance unattended when the burners are being used. Make sure there are no children in the near vicinity. Particularly make sure that the pan handles are correctly positioned and keep a chek on foods requiring oil and grease to cook since these products can easily catch fire.
- The machine must not be used by people (including children) with impaired mental or physical capacities, or without experience of using electrical devices, unless supervised or instructed by an expert adult responsible for their care and safety. Children should not be allowed to play with the equipment.
- Never use aerosols near the appliance when it is operating.
- If the built-in hot plate has a lid, any spilt food should be immediately removed from this before it is opened. If the appliance has a glass lid, this could shatter when the hot plate becomes hot. Always switch off all the burners before closing the lid.
- Containers wider tha n th e unit are recommended.
USE
FIG. 1 FIG. 2
Burners Power ratings Pan Ø in cm
Ultra rapid 11000 Btu/h 24 ÷ 26
Rapid 10000 Btu/h 20 ÷ 22
Semirapid 6100 Btu/h 16 ÷ 18
Semirapid 6100 Btu/h 16 ÷ 18
Auxiliary 3550 Btu/h 10 ÷ 14
5
USE
Notes: use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated. Intensive and lengthy use of the appliance may require additional ventilation. This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed.
WARNING!
NEVER use this appliance as a space heater to heat or warm the room. Doing so may result in car bon mon oxi de poi soni ng and overheating ot the oven.
6
CLEANING
FIG. 3
IMPORTANT: always disconnect the appliance from the gas and electricity mains before carrying out any cleaning operation.
3) WORKTOP
Periodically wash the hot plate, the enamelled stell pan support, the enamelled burner caps “C” and the burner heads “T” (see fig. 3) with lukewarm soapy water. Following this, all parts should be thoroughly rinsed and dried. Never wash them while they are still warm and never use abrasive powders. Do not allow vinegar, coffee, milk, salted water, lemon or tomato juice from remaining in co ntact with the enamelled surf aces for long periods of time.
WARNINGS: comply with the following instructions, before remounting the parts:
- check that burner head slots “T” (fig. 3) have not become clogged by foreign bodies.
- Check that enamelled burner cap “C” (fig. 3) have correctly positioned on the burner head. It must be steady.
- The exact position of the pan support is established by the rounded corners, which should be set towards the side edge of the hot plate.
- Do not force the taps if they are difficult open or close. Contact the technical assistance service for repairs.
- Don’t use ste am je ts for the e qui pme nt cleaning.
7
INSTALLATION
TECHNICAL INFORMATION
FOR THE INSTALLER
Insta llation, adjus tments of controls a nd maintenance must only be carried out by a qualified engineer. Incor rect installati on may cause d amage to perso ns, ani mal s or p roperty for whi ch the Manufacturer shall not be considered responsible. During the life of the system, the automatic safety or regulating devices on the appliance may only be modified by the manufacturer or by his duly authorized dealer.
4) INSTALLING THE WORKTOP
Check that the appliance is in a good condition after having removed the outer packaging and internal wrappings from around the various loose parts. In case of doubt, do not use the appliance and contact qualified personnel.
Never leave the packaging materials (cardboard, bags, polystyrene foam, nails, etc.) within children’s reach since they could become potential sources of danger.
The measurements of the opening made in the top of the modular cabinet and into which the hot plate will be installed are indicated in either fig. 4. Always comply with the measurements given for the hole into which the appliance will be recessed (see fig. 4 and 5)
.
5) FIXING THE HOT PLATE
The hot plate has a special seal which prevents liquid from getting into the cabinet. Strictly comply with the following instructions in order to correctly apply this seal:
- detach the seals from their backing, checking that the transparent protection still adheres to the seal itself.
- Overturn the hot plate and correctly position seal “E” (fig. 6) under the edge of the hot plate itself, so that the outer side of t he s eal perfectly matches the outer edge of the hot plate. The ends of the st rips must fit toge ther w ithout overlapping.
- Evenly and securely fix the seal to the hot plate, pressing into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet.
- Fix the hob with the proper brackets “S” and fit the prominent part into the porthole “H” on the bottom; turn the screw “F” until the bracket “S” stick on the top (fig. 7).
- The prospective walls (left or right) that exceed the working table in height must be at a minimum distance from the cutting as mentionned both in the columns and the scheme.
- In order t o av oid accid ental touch wit h the ove rhe ati ng bot tom of the hob , dur ing t he working, is necessary to put a wooden insert, fixed by screw s, a t a minimum dis tance of
150 m m f rom the l ower s urfa ce of the t op
(see fig. 4).
FIG. 4
FIG. 5 FIG. 6
FIG. 7
COMPLY WITH THE
DIMENSIONS (in mm)
A B C D E
4F (60) 553 473 67.5 59.5 100 min. 5F (90) 833 475 67.5 62.5 73.5 min.
INSTALLATION
8
6) ROOM VENTILATION
To ensure correct operation of the appliance, it is important to ensure that the room where the hot plate is installed has sufficient ventilation.
7) GAS CONNECTION
Natural Gas and Propane Gas
Natural Gas installations require the connection of a gas regulator at the appliance. This regulator is supplied with the appliance on purchase. Assemble the regulator (no ting th e gas flow direction) and transition pieces (supplied with the appliance), in accordance with below figure.
The transition piece on the supply side of the regulator must be provided by the installer. Unions compatible with the hose fittings must be used and connections tested for gas leaks. Ensure the supply connection point is accessible with the appliance installed. Warning : ensure that the hos e assemb ly is restrained from accidental contact with the flue or flue outlet of an underbench oven.
9
INSTALLATION
FIG. 8
8) ELECTRICAL CONNECTION
The electrical connections of the appliance must be carried out in compliance with the provisions and standards in force.
Before connecting the appliance, check that:
- the electrical capacity of the mains supply and current sockets suit the maximum power rating of the appliance (consult the data label applied to the underside of the hot plate).
- The socket or system has an efficient earth connection in compliance with the provisions and standards in force. The manufacturer declines all responsibility for failing to comply with these provisions.
When the ap pliance is con nected to the electricity main by a socket:
- fit a standard plug suited to the load indicated on the data label to the cable.
- Fit the wires following figure 8, taking care of respecting the following correspondences:
Letter L (live) = wire;
Letter N (neutral) = wire;
earth symbol = green or yellow-green wire.
- Never use reductions, adapters of shunts for connection since these could create false contacts and lead to dangerous overheating.
- The outlet must be accessible after the built-in.
When the appliance is connected straight to the electricity main:
- install an omnipolar circuit-breaker between the appliance and the electricity main. This circuit­breaker should be sized, in compliance with current installation regulations.
- Remembe r that the earth wire must not be interrupted by the circuit-breaker.
- For optimum safety, the electrical connection may also be protected by a high sensitivity differential circuit- breaker.
You are strongly advised to fix the relative yellow­green earth wire to an efficient earthing system.
10
INSTALLATION
9) FIXING THE WORKTOP
The hot plate has a special seal which prevents liquid from infiltrating into the cabinet. Strictly comply with the following instructions in order to correctly apply this seal:
- detach the seals from their backing, checking that the transparent protection still adheres to the seal itself.
- Overturn the hot plate and correctly position seal “E” (fig. 6) under the edge of the hot plate itself, so that the outer side of the seal perfectly matches the outer perimetral edge of the hot plate. The ends of the s trips must fit together without overlapping.
- Evenly and securely fix the seal to the hot plate, pressing into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet.
- Fix the hob with the proper brackets “S” and fit the prominent part into the porthole “H” on the bottom; turn the screw “F” until the bracket “S” stick on the top (fig. 7).
- The prospective walls (left or right) that exceed the working table in height must be at a minimum distance from the cutting as mentionned both in the columns and the scheme.
- In ord er t o av oid accidental touch with the overheating bottom of the hob, during the working, is necessary to put a wooden insert, fixed by screws, at a minimum distance of 60 mm from the lower surface of the top (see fig. 4).
11
FIG. 9
ADJUSTMENTS
Always disconnect the appliance from the electricity main before making any adjustments. All seals must be replaced by the technician at the end of any adjustments or regulations. Our burner s do not r equire primar y air adjustment.
10) TAPS
“Reduced rate” adjustment
- Switch on the burner and turn the relative knob to the “Reduced rate” position (small flame fig.1).
- Remove knob “M” (fig. 9) of the tap, which is simply pressed on to its rod.
- Insert a small screwdriver “D” into hole “C” (fig. 9) and turn the throttle screw to the right or left until the burner flame has been adequately regulated to the “Reduced rate” position.
Check that the flame does not go out when the knob is sharply switched from the “Full on” to the “Reduced rate” position.
It is understood that only burners operating with Natural Gas o r Town gas shoul d be subjected to the above mentioned adjustments. The screw must be fully loc ked when the burne rs operate with Propa ne HD-5 (turn clockwise).
12
BURNER ARRANGEMENT ON THE HOT PLATE
TABLE
FIG. 10
CONVERSIONS
11) REPLACING THE INJECTORS
The burners can be adapted to different types of gas by mounting injectors suited to the type of gas in question. To do this, first remove the burner tops using a wrench “B”. Now unscrew injector “A” (see fig. 10) and fit a injector corresponding to the utilized type of gas in its place. It is advisable to strongly tighten the injector in place.
After the injectors have been replaced, the burners must be regulated as explained in
paragraphs 10. The technician must reset any seals on the regulating or pre-regulating devices. The envelope with the injectors and the labels can be included in the kit, or at disposal to the authorized customer Service Centre.
For the sake of convenience, the nominal rate table also lis ts the heat i nputs of the bu rners, th e diameter of the injectors and the working pressures of the various types of gas.
BURNERS
GAS
NORMAL
PRESSURE
inches water
column
INJECTOR
DIAMETER
1/100 mm
NOMINAL HEAT
INPUT (B
tu/h
)
DESCRIPTION
Min. Max.
1
ULTRA RAPID
PROPANE HD - 5 NATURAL GAS
11
7
94
176
4400 4400
11000 11000
2
RAPID
PROPANE HD - 5 NATURAL GAS
11
7
91
155
2500 2500
10000 10000
3
SEMIRAPID
PROPANE HD - 5 NATURAL GAS
11
7
70
120
1500 1500
6100 6100
4
SEMIRAPID
PROPANE HD - 5 NATURAL GAS
11
7
70
120
1500 1500
6100 6100
5
AUXILIARY
PROPANE HD - 5 NATURAL GAS
11
7
53 90
1200 1200
3550 3550
13
SERVICING
FIG. 14 FIG. 15 FIG. 16
FIG. 11 FIG. 12 FIG. 13
Always disconnect the appliance from the electricity and gas mains before proceeding with any servicing operation.
12) REPLACING COMPONENTS
Replacement of the components housed inside the appliance: remove the trivets and the burners from the upper part of the working table; remove the fixing screws "V" of the burner (fig. 11) and the knobs fixed by pressure with the hans, in order to take off the appliance. After having carried out the above listed operations, the burners (fig. 12), taps (fig. 13) and electrical components can all be replaced (fig. 14). NB: the ignition bar must be removed before replacing the taps in appliances with automatic ignition systems. It is advisable to change seal “D” whenever a tap is replaced to ensure a perfect tightness.
Greasing the taps (see fig. 15 - 16)
If a ta p becomes stiff to ope rate, it m ust be immedia tely gr eased in complian ce with th e following instructions:
- remove the tap.
- Clean the cone and its housing using a cloth soaked in diluent.
- Lightly spread the cone with the relative grease.
- Fit the cone back in place, operate it several times and then remove it again. Eliminate any excess grease and check that the gas ducts have not become clogged.
- Fit all parts back in place, complying with the demounting order in reverse.
- The tight closure test must be done using a foamy liquid. The use of the flame is prohibited.
To facilitate the servicing technician’s task, here is a chart with the types and sections of the powering cables and the ratings of the electrical components.
14
4 BURNERS (60)
PROPANE HD - 5 = 11 inches water column NATURAL GAS = 7 inches water column
Σ Qn Natural Gas = 25750 Btu/h
Voltage = 120 V AC
Frequency = 60 Hz
TECHNICAL DATA ON THE DATA LABEL
5 BURNERS (90)
PROPANE HD - 5 = 11 inches water column NATURAL GAS = 7 inches water column
Σ Qn Natural Gas = 36750 Btu/h
Voltage = 120 V AC
Frequency = 60 Hz
15
TECHNICAL DATA FOR THE APPLIANCE
GAS REGULATION
Before leaving the factory, this appliance will have been tested and regulated by expert and specialized personnel in order to guarantee the best performances. Any repairs or adjustments which may be subsequently required may only be carried out by qualified personnel with the utmost care and attention. For this reason, always contact your Dealer or our nearest After Sales Service Center whenever repairs or adjustments are required, specifying the type of fault and the model of the appliance in your possession. Please also note that genuine spare parts are only available from our After Sales Service Centers and authorized retail outlets. The above data are printed on the data label put on the inferior part of the appliance and on the packing label. The above informations give to the technical assistant the possibility to get fit spare parts and a heaven­sent intervention. We suggest to fill the table below.
MARK: ..........................................................................
MODEL: ........................................................................
SERIES: ........................................................................
TECHNICAL ASSISTANCE AND SPARE PARTS
Kuppersbusch USA
1883 Massaro Blvd. Tampa, FL 33619
Toll: (800) 459-0844 P: 813-288-8890 F: 813-288-8604