JVC XV-N222SUC, XV-N222SUS Service Manual

SERVICE MANUAL
DVD PLAYER
YD06420054
XV-N222SUS,XV-N222SUC
Area Suffix
US ----------------------- U.S.A. UC ------------------- Canada
STANDBY/ON
OPEN/ CLOSE
+
SLOW
DISPLAYON SCREEN
T
O
T
P
H
U
M
B
N
A
IL
L
ENTER
S
NEXTPREVIOUS
SELECT
CLEAR
123
456
789
0
SOUND
VFP
EFFECT
I/P
SUBTITLEANGLE
AUDIO
ZOOM
/
IS
T
E
T
U
P
®
VIDEO
XV-N222SUSC,XV-N222SUCC
M
E
N
U
M
E
N
U
CANCEL RETURN
TITLE/
GROUP DIMMER
SLIDE EFFECT
This model is the derivation model which changed a part of exterior parts of XV-N322S for US,UC. This service manual consists of only "Parts list", "Instruction Book". Regarding service information other than these sections, refer to the service manual XV-N320B,XV-N322S(issue number : YD053).
TABLE OF CONTENTS
2 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
3 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
4 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
5 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
COPYRIGHT © 2005 Victor Company of Japan, Limited
No.YD064
2005/4
SPECIFICATION
XV-N222SUS,XV-N222SUC
General
Readable discs DVD VIDEO, DVD-R (Video format), DVD-RW (Video format), SVCD, Video CD, Audio CD (CD-DA),
CD-R/RW (CD-DA, SVCD, Video CD, JPEG)
Video format NTSC, 480i/480p selectable
Other
Power requirements AC 120 V~, 60 Hz
Power consumption 11.0 W (POWER ON), 1.0 W (STANDBY mode)
Mass 1.5 kg (3.3 lbs)
Dimensions (W × H × D) 435mm × 44mm × 201.5 mm (17-3/16 inch × 1-3/4 inc × 7-15/16 inch)
Video outputs
COMPONENT (pin jacks) Y Output: 1.0 Vp-p (75 Ω)
Pb/Pr Output: 0.7Vp-p (75 Ω) VIDEO (pin jack) 1.0 Vp-p (75 Ω) S-VIDEO (S jack) Y Output: 1.0 Vp-p (75 Ω)
C Output: 286 mVp-p (75 Ω)
Horizontal resolution 500 lines or more
Audio outputs
ANALOG OUT (pin jack) 2.0 Vrms (10 kΩ) DIGITAL OUT (COAXIAL) 0.5 Vp-p (75 termination)
Audio characteristics
Frequency response CD (sampling frequency 44.1 kHz):2 Hz to 20 kHz
DVD (sampling frequency 48 kHz):2 Hz to 22 kHz
(4 Hz to 20 kHz for DTS and Dolby Digital bitstream signals)
DVD (sampling frequency 96 kHz):2 Hz to 44 kHz
Wow and flutter Unmeasurable (less than +- 0.002%)
Total harmonic distortion less than 0.009%
1-2 (No.YD064)
SECTION 1
PRECAUTION

1.1 Safety Precautions

(1) This design of this product contains special hardware and
many circuits and components specially for safety purpos­es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per­formed by qualified personnel only.
(2) Alterations of the design or circuitry of the product should
not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteris­tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us­ing replacement components rated for higher voltage, watt­age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser­vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac­teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.
(4) The leads in the products are routed and dressed with ties,
clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem­bling.
(5) Leakage shock hazard testing)
After reassembling the product, always perform an isola­tion check on the exposed metal parts of the product (an­tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check.
• Plug the AC line cord directly into the AC outlet. Using a "Leakage Current Tester", measure the leakage current from each exposed metal parts of the cabinet, particular­ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur­rent must not exceed 0.5mA AC (r.m.s.).
• Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensi­tivity in the following manner. Connect a 1,500 ohm 10W resistor paralleled by a 0.15 F AC-type capacitor be­tween an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return
path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.).
AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity)
0.15 F AC TYPE
Place this probe on
1500 10W
Good earth ground

1.2 Warning

(1) This equipment has been designed and manufactured to
meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that
these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant
safety standards.
(4) It is essential that safety critical components are replaced
by approved parts.
(5) If mains voltage selector is provided, check setting for local
voltage.

1.3 Caution

Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pre­forming repair of this system.

1.4 Critical parts for safety

In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the " " mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (Except the JC version)
each exposed metal part.
(No.YD064)1-3
Loading...