JVC RK-C42WBT3 User Manual

Wall Mounting Unit
Assembly and Mounting Instructions
RK-C42WBT3
Thank you for purchasing this Wall Mounting Unit. We recommend that you read this manual thoroughly before use in order to familiarize yourself with this unit. Please store this manual in a safe place after reading it.
Mounting a plasma display television requires specific technical knowledge. Do not attempt to mount the unit by yourself.
Please be aware that screw holes and anchor bolts will remain in the wall surface if the Wall Mounting Unit is removed
after having been mounted to the wall. Long-term use of the plasma display may result in discoloration of the wall surface due to heat/air emitted by the display.
For Assembly By Authorized Service Personnel Only
Consult authorized service personnel for the installation of this unit. Installation instructions must be followed precisely in order to prevent accidents. We are selling this product with the understanding that it will be assembled and installed by properly trained and qualified service personnel.
We are not liable for any damage caused by faulty assembly, faulty wall mounting, insecure wall mounting, misuse, alterations, or natural disasters.
Danger
This unit weighs approx. 60 kg (approx. 132 lbs.) including plasma display monitor. Incomplete or inadequate mounting of this unit to the wall may cause it to fall down, resulting in potentially fatal accidents. Please consult authorized service personnel for the installation of this unit.

Safety Precautions

Explanation of symbols
The following section describes the symbols used in this manual. Read this section prior to using the product for correct usage. The following items contain information for your safety. Follow these precautions precisely. Warning and Caution are defined as follows:
Danger
Warning
Caution
Improper handling in disregard of these notices may result in danger of death or bodily harm.
Improper handling in disregard of these notices may result in bodily injury and even death.
Mishandling of the unit in disregard of these notices may result in bodily injury or damage to the unit.
Examples:
The indicates caution (including warning or danger).
The indicates a prohibition, with the specific action indicated either in the circle itself (the symbol at left means "Do Not Disassemble"), or in the accompanying text.

Assembly and Mounting Warnings

Consult authorized service personnel for the installation and attachment of this unit to the wall. This unit weighs approx. 60 kg (approx. 132 lbs.), including display monitor. Improper assembly or installation may cause the unit to fall when it is mounted, which may result in fatal accidents. To prevent this happening, check the strength of the materials in the mounting surface, and have at least two persons carry out the installation in a suitable location. Check the material strength again after mounting as well.
Using display monitors other than those authorized by Victor with the unit may result in damage or bodily injury due to the display monitor and stand toppling over.
Assemble all bolts, nuts and screws securely. Failure to do so may result in display monitor and wall mounting falling down, potentially causing damage or bodily injury.
Avoid placing heavy objects on the power cord, as damage to the power cord may result, causing fire or electric shock.
This unit does not come with anchor bolts for securing it to walls, etc. Be sure you have materials on hand as appropriate for the mounting location.
2
Mounting the Wall Unit
Plasterboard/Thin Plywood
Warning
The Wall Mounting Unit should be mounted to a wall that can adequately hold the total weight of the plasma display and the Wall Mounting Unit over a long period of time and which can adequately withstand earthquakes, conceivable vibrations, and other external forces.
Improper installation may cause the plasma display to fall down, resulting in physical injury.
Mounting On Wooden Walls
The weight of the unit should be borne by the wall posts or studs, and these should be reinforced if insufficiently strong. Do not install the Wall Mounting Unit on walls made of plasterboard or thin plywood. Use the commercially sold screws best suited for the wall structure and material.
Mounting On Concrete Walls
Use commercially sold wall anchors capable of supporting the weight of the plasma display.
Do not install the Wall Mounting Unit in a location which is hot or humid or which may become wet, as the presence of excessive moisture may lead to fire or electric shock. Do not install the Wall Mounting Unit near the blower or air inlet of an air conditioner. Do not install the unit in a location with a large amount of dust, soot, or cigarette smoke, as this may lead to fire.
At least 15 cm
At least 20 cm
Do not block the ventilation holes, and be sure to leave sufficient space around the unit for ventilation.
Inadequate ventilation may cause the unit interior to overheat, leading to fire.
Do not install the Wall Mounting Unit on a non-vertical wall.
The unit interior may overheat, resulting in fire, or the unit may fall down, causing physical injury.
Do not install the Wall Mounting Unit in a location subject to frequent vibration, impact or other external forces.
The unit may fall down or be damaged, causing physical injury.
Do not install the unit in a location where people may hang on it or lean against it.
Doing so may cause the unit to fall down or be damaged, resulting in injury.
Do not install the unit in a location exposed to direct sunlight or strong light, as viewing the plasma display in an overly bright environment can be tiring for the eyes.
3
Caution
Consult authorized service personnel for electrical work. Using power cords damaged during installation (i.e., exposed or severed wiring) may result in fire or electric shock.
Conduct the work with adequate working space. Damage or bodily injury may result from working under unsuitable conditions.
Avoid mounting this unit in areas where there is electrical wiring or water pipes, as fire or electric shock may result.

Tools Required for Assembly:

1. Type 2 Philips Screwdriver (+)
2. Type 2 Philips Screwdriver (+) with 300mm (approx. 12-inch) or longer shaft
<Names of Parts>
Frame Fastening Screws left/right (Spacer Ring + Flat Washer + Spring Washer)
Angle Adjustment Lever
w
Plasma Display
q
e
Frame Rotation Jaw
X 10
r Angle Adjustment
Lever Lock Screw
Frame Rotation Shaft Screws (left/right)
Spacer Rings (left/right)
<Components List>
q Frame................................................................... 1
w Wall Mounting Unit............................................... 1
4
Parts bag contains:
Frame Attachment Lever Screws
e Screw (M5 X 30).......................... 10
r Screw (M5 X 20)............................ 1
<Before Attaching Plasma Display>
The Wall Mounting Unit is sold with Frame q and Wall Mounting Unit w fixed together. The following steps should be performed before attaching the plasma display.
1. Take the left and right Frame Fastening Screw Components and remove the Fastening Screw, Spacer Ring, Flat
Washer, and Spring Washer. These Frame Fastening Screws, Spacer Rings, Flat Washers, and Spring Washers will be used when attaching
the plasma display to the Wall Mounting Unit. Be sure to keep them in a safe place.
Frame Fastening Screw
Spring Washer
Flat Washer
Spacer Ring
q Frame
w Wall Mounting Unit
2. Push in the heads of the left and right Frame Removal Lever Screws a and lift up section b to remove the Frame q from the Wall Mounting Unit w.
q Frame
Frame Removal Lever Screws
Wall Mounting Unit
w
5
Mounting the Plasma Display
Fasten all bolts and screws securely. Failure to do so may cause the plasma display and Wall Mounting Unit to fall down, causing potentially fatal accidents.
Danger
Instructions for Assembly
1. Attach the Wall Mounting Unit w to the surface of the wall. The unit should be attached using the method most suited to the wall structure. When anchor nuts/bolts are to be inserted into the wall before mounting, either align the actual Wall
Mounting Unit w with the wall to determine the positioning of the holes or calculate the positioning of the holes using a dimensional drawing of the unit before installing the anchor nuts/bolts.
Improper positioning/installation of the Wall Mounting Unit on the wall may cause the unit to fall down. Check the structure, material, and strength of the mounting surface thoroughly and carry out installation in a suitable location. Failure to do so may cause the plasma display and Wall Mounting Unit to fall down, leading to potentially fatal accidents.
Position of Wall Mounting Holes
Wall Surface Side (Wall Mounting Unit)
2. Attach Frame q to the plasma display. The screws (M5X30) e should be used to attach the Frame q to a plasma display. A soft mat or similar material should be laid out to prevent damage to the plasma display during attachment to
the unit.
Plasma Display
eScrews (M5X30) x 10
w Wall Mounting Unit
Align the first Mounting Hole
6
<Instructions for Assembly, cont’d>
Caution
3. Identify the Rotation Shaft Screws of the Wall Mounting Unit. Check that the left and right Rotation Shaft Screws are secure, as the Rotation Jaw of the Frame (attached to the plasma display) will be inserted into the Rotation Shaft Screw Component of the Wall Mounting Unit w.
Avoid inserting fingers into the gap between the Frame and the Wall Mounting Unit when putting these together, as fingers will get trapped, causing injury.
w Wall Mounting Unit
Rotation Shaft Screw Component
4. Attach the plasma display to the Wall Mounting Unit. This task must be performed by at least two persons.
Insert the Rotation Jaw of the Frame q (attached to the plasma display) securely into the Rotation Shaft Screw Component of the Wall Mounting Unit, then raise up the plasma unit on this axis and push it into place
- it should lock with a clicking sound. Before releasing the unit, check that the plasma display is securely fitted and does not rattle and loose.
Rotation Shaft Screw
Spacer Ring
Rotation Jaw
q Frame Rotation Jaw
7
<Instructions for Assembly, cont’d>
Avoid inserting fingers into the gap between the Frame and the Wall Mounting Unit when
Caution
5. Fix the Frame and Wall Mounting Unit. Combine the Frame Fastening Screws, Spacer Rings, Flat Washers, and Spring Washers (from the two pairs of Frame Fastening Screw Components that were put aside when detaching the Frame q from the Wall Mounting Unit w) as shown below and fasten them securely using a screwdriver.
Frame Fastening Screw
Spring Washer
Flat Washer
Spacer Ring
putting these together, as fingers will get trapped, causing injury.
Frame Fastening Screw Component
Confirm that all of the parts are securely fastened and do not rattle and loose.
Frame Fastening Screw Spring Washer Flat Washer Spacer Ring
8
<Instructions for Assembly, cont’d>
Grip the plasma display firmly while adjusting the angle, as the display could tip over and cause
Caution
injury.
Adjusting the Angle of the Plasma Display
The angle of the Wall Mounting Unit can be adjusted to 0°, 5°, 10°, 15°, and 20°.
1. Adjust the angle of the plasma display. Brace the upper middle part of the plasma display with one hand and push the Angle Adjustment Lever to the left with the other hand. The plasma display will tip forward. Release the Angle Adjustment Lever when the desired angle setting is reached.
Angle Adjustment Lever
2. Fix the Angle Adjustment Lever. Once the plasma display has been set at the desired angle, fasten the Angle Adjustment Lever with the screw (M5X20) r.
r Screw (M5X20) x 1
Check to make sure that the Angle Adjustment Lever is securely fastened and the plasma display does not
rattle and loose.
Note: do not fasten the Angle Adjustment Lever if the power cord or system cables have yet to be attached.
9
<Instructions for Assembly, cont’d>
Connecting the Power Cord and System Cables
Caution
1. Check the Frame Fastening Screws. Check that the two Frame Fastening Screws on the upper left and right sides of the Wall Mounting Unit are
securely fastened.
Grip the plasma display firmly while connecting the power cord/system cables, as the display may tip over and cause injury.
Frame Fastening Screws
Caution
If the Frame Fastening Screws are not securely fastened the plasma display may fall, causing potentially fatal injury.
2. Place one hand on top of the plasma display to steady it and with the other hand set the Angle Adjustment Lever to 20°. If the Angle Adjustment Lever has already been fastened, perform this task after removing the Angle
Adjustment Lever Lock Screw.
20°
Caution
Grip the plasma display as you adjust the angle, as the plasma display may tip over and cause injury.
10
Angle Adjustment Lever Lock Screw
<Instructions for Assembly, cont’d>
Caution
Brace the plasma display when connecting the power cable or system cables. Failure to do so may allow it to tip over, potentially causing injury.
3. Remove the Rotation Shaft Screws and Spacer Rings at the bottom left and right of the Wall Mounting Unit. The Rotation Shaft Screws and the Spacer Rings will be used after the cables have been connected. Be sure
to keep them in a safe place.
Rotation Shaft Screws
Spacer Rings Rotation Shaft Screws
4. Pull the plasma display forward. Brace the bottom of the plasma display and push up the heads of the screws at the left/right of the Frame Attachment Lever Screw component at the bottom of the Wall Mounting Unit, until the screws come into contact with the Frame. The plasma display can now be pulled forward. This task must be performed by at least two persons.
Frame Attachment Lever Screw Component
Plasma Display
Frame
Wall Mounting Unit
Pull Forward
Lateral View
11
<Instructions for Assembly, cont’d>
Caution
5. Connect the power cable and system cables to the plasma display.
Brace the plasma display while connecting the power cord or system cables, as the display may tip over, causing injury.
Be careful not to let the cables become caught between the plasma display and the Wall Mounting Unit.
6. Fix the Plasma Display to the Wall Mounting Unit. Push the bottom of the plasma display toward the Wall Mounting Unit to securely fasten the display to the Wall Mounting Unit. Then, fasten the Rotation Shaft Screw Component at the bottom left/right of the Wall Mounting Unit with the Rotation Shaft Screws and the Spacer Rings. This task must be performed by at least two persons.
Rotation Shaft Screw
Rotation Shaft Screw
Spacer Ring
Spacer Ring
Rotation Shaft Screw
12
<Instructions for Assembly, cont’d>
7. Set the angle of the plasma display. Hold the upper part of the plasma display with one hand and set the display to the desired angle with the other hand, using the Angle Adjustment Lever on the Wall Mounting Unit.
Angle Adjustment Lever
Caution
Grip the plasma display firmly as you adjust the angle, as the display may fall forward and cause injury.
8. Fasten the Angle Adjustment Lever. Once the angle of the plasma display has been set, fasten the Angle Adjustment Lever with the Screw (M5X20)
r.
r Screw (M5X20) x 1
Check to make sure that the lever is securely fastened and the plasma display does not rattle.
13
<Instructions on Removing the Plasma Display>
Danger
1. Hold the upper middle of the plasma display and set the Angle Adjustment Lever to 0°. If the Angle Adjustment Lever has been fastened, remove the Angle Adjustment Lever Lock Screw before
performing this task.
This task must be performed by at least two persons.
Angle Adjustment Lever
Angle Adjustment Lever Lock Screw
2. Confirm that the Frame Rotation Shaft Screws at the left and right bottom of the Wall Mounting Unit are securely fastened.
Rotation Shaft Screws
14
<Instructions for Removing the Plasma Display, cont’d.>
Danger
3. Remove the Frame Fastening Screws, Spacer Rings, Flat Washers, and Spring Washers of the two Frame Fastening Screw Components at the upper left and right of the Wall Mounting Unit.
This task must be performed by at least two persons.
Frame Fastening Screws
4. Push up the heads of the screws in the Frame Attachment Lever components at the bottom left and right of the Wall Mounting Unit until they come into contact with the Frame. Then tilt the plasma display 90° forward and, without changing the inclination of the plasma display, pull the display out horizontally.
Frame Removal Lever Screws
15
Mass: 10 kg Angles of Inclination: 0°, 5°, 10°, 15°, 20°
<External Dimensions>
8190
170131
Wall Mounting Holes
13
13
2-φ5
2-φ8
2020
4-R10
110 2016020
E Section
E
470 400 340 130
4-R10
50110
13
2-φ5
2-φ8
F Section
13
20
2020
F
8.5
42-inch Display
16.5
81.5159.5
140101.5
499
20°
300
89 49
2-φ5
2-φ8
6-R10
E Section Details
20
13
1
13
2-φ5
2-φ8
1
60 120
(Outer edge)
568
20
6-R10
120180
2-φ5
2-φ8
F Section Details
1313
20
13
1
Wall Mounting Unit Exterior
1313
2-φ5
20
13
1
2-φ8
(Units in millimeters)
© 2004 VICTOR COMPANY OF JAPAN, LIMITED
VICTOR COMPANY OF JAPAN, LIMITED
RK-C42WBT3-INST-0405-A
Loading...