These models corresponded to the printed circuit board exchange in the PDP panel.
Therefore, this service manual describes only the information relevant to it.
For details other than those described in this manual, please refer to the PD-42D30ES service
manual (No.52090 2003/03), PD-42D30ES/A service manual (No.52090B 2003/06).
BASIC CHASSIS
MK
TABLE OF CONTENTS
1. CONFIRMING THE MODEL NAME, SERIAL NUMBER, ID NUMBER, AND CODE NUMBER
Model : NP42D2MF01AA
Serial No. : 211200192 (9 figures)
■MAIN PARTS LOCATION
COMMON PWB
Flexible cable
Common-side A
Flexible cable
Common-side B
Flexible cable
Common-side C
SIGNAL RELAY PWB(left)
ABCDEFGHIJKLMNOP
COMMON BRANCH PWB
DIGITAL PWB
SIGNAL RELAY PWB(right)
Heat-sink
SCAN RELAY PWB(upper)
HIGH VOLTAGE
PWB
Flexible cable
Scan-side A
Flexible cable
Scan-side B
Flexible cable
Scan-side C
Flexible cable
Scan-side D
SCAN RELAY
PWB(lower)
2(No.52090C)
Page 3
■INSPECTION OF COMPONENTS ON THE PW BOARD
Diagnose the PW board in PDP unit by checking defects based on the following items.
1. Inspection of fuses
Measure the resistance of each fuse with a circuit tester, and check OK or NG.
1.1 Glass fuses (F301, F302) on the HIGH VOLTAGE PWB1.2 Chip fuse (FU801) on the DIGITAL PWB
F301
OK: Short
NG: Open
F302
FU801
OK: Short
NG: Open
1.3 Fuse resistances (R10, R4, R6) and chip fuse (R20)
on the HIGH VOLTAGE PWB
R10
OK: Approx. 2.2Ω
NG: Open
R10
R4
R20
R4
OK: Approx. 2.2Ω
NG: Open
R6
R6
OK: Approx. 2.2Ω
NG: Open
R20
OK: Approx. 10Ω
NG: Open
R1
OK: Approx. 2.2Ω
R1
NG: Open
1.4 Fuse resistances (R7, R3) and chip fuse (R9)
on the HIGH VOLTAGE PWB
R7
R3
OK: Approx. 2.2Ω
NG: Open
R3
OK: Approx. 2.2Ω
R7
NG: Open
R9
R9
OK: Approx. 10Ω
NG: Open
1.6 Fuse resistance (R2) on the HIGH VOLTAGE PWB1.5 Fuse resistance (R1) on the HIGH VOLTAGE PWB
R2
R2
OK: Approx. 2.2Ω
NG: Open
1.7 Fuse resistance (R90) on the HIGH VOLTAGE PWB
R90
OK: Approx. 2.2Ω
R90
NG: Open
(No.52090C)3
Page 4
2. Inspection of data ICs
According to the following procedures, measure with a circuit tester and check OK or NG.
Check the pin 1 or pin 2 of the connector [CN12] on the SIGNAL RELAY PWB (right).
OK: Open
NG: Short
Detach the connector [CN12] on the SIGNAL RELAY PWB (right) and check the conduction between the pin 1 (or
pin 2) and the ground.
In case of "short", one of the data ICs connecting the SIGNAL RELAY PWB may be defective, and you should check
whether there is any trace of damage on the data IC's surface after removing the heat-sink on the data IC.
3. Inspection of power IC
According to the following procedures, measure with a circuit tester and check OK or NG.
The allocation of power IC to be checked is shown below.
HIGHT VOLTAGE PWB
PH2203F
4(No.52090C)
Page 5
3.1 PH2203F on the HIGH VOLTAGE PWB
Turn over the board and check each point of power IC as shown below.
PH2203F
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
U
T
S
R
Check point
Between
A - B
A - U
B - C
B - E
B - M
B - N
Between
C - U
F - U
G - H
H - J
I - J
J - K
Between
J - O
L - M
P - T
Q - T
OK: Over 1kΩ
NG: Short
U
A
B
C
D
E
F
G
H
PH2203F
I
J
K
L
M
N
T
O
S
R
P
Q
4. Inspection of scan IC drivers
According to the following procedures, measure with a circuit tester and check OK or NG.
4.1 Scan IC driver on the SCAN RELAY PWB (upper right)4.2 Scan IC driver on the SCAN RELAY PWB (lower right)
NEGA 1
POSI 2
POSI 1
NEGA 2
Check point
Between NEGA - POSI
OK: Over 1kΩ
NG: Short
Check point
Between NEGA - POSI
OK: Over 1kΩ
NG: Short
(No.52090C)5
Page 6
■DISASSEMBLY PROCEDURE
1. Removing the COMMON PWB
(1) Detach the 3 connectors.
(2) Remove the 8 screws [A].
(3) Remove the COMMON PWB.
(1) Detach the 10 connectors.
(2) Remove the 4 screws [D].
(3) Remove the SIGNAL RELAY PWB (left).
2. Removing the DIGITAL PWB
(1) Detach the 6 connectors.
(2) Remove the 6 screws [B].
(3) Remove the DIGITAL PWB.
3. Removing the HIGH VOLTAGE PWB
(1) Detach the 5 connectors.
(2) Remove the 22 screws [C].
(3) Remove the HIGH VOLTAGE PWB.
4. Removing the SIGNAL RELAY PWB (left)
Note : Removing the heat-sink in advance
is required. Refer to the following page
to remove the heat-sink.
B
COMMON
PWB
A
COMMON BRANCH PWB
5. Removing the SIGNAL RELAY PWB (right)
(1) Detach the 13 connectors.
(2) Remove the 5 screws [E].
(3) Remove the SIGNAL RELAY PWB (right).
6. Removing the SCAN RELAY PWB (upper)
(1) Detach the 5 connectors.
(2) Remove the 8 screws [F].
(3) Remove the SCAN RELAY PWB (upper).
7. Removing the SCAN RELAY PWB (lower)
(1) Detach the 5 connectors.
(2) Remove the 8 screws [G].
(3) Remove the SCAN RELAY PWB (lower).
C
SCAN RELAY PWB (upper)
F
SIGNAL
RELAY
PWB
(left)
HIGH VOLTAGE
PWB
DIGITAL PWB
Heat-sink
: connector
D
SIGNAL RELAY PWB (right)
E
Note : Check the state of the detached cables and connectors.
(1) Check any dirt or peeling in the contact part of the flat cable, and any crack, crease, disconnection
and short-circuit of wires.
(2) Check any foreign substance in the connector's contact .
(3) Check the state of plugging the flat cable into the connector, and confirm it locks completely.
G
SCAN
RELAY
H
PWB
(lower)
6(No.52090C)
Page 7
Fig. 1
Fig. 2
Fig. 3
REMOVING THE HEAT SINK
(1) Remove the 11 screws [H] shown in the previous page.
(2) Slowly, as shown in Fig.1 and Fig.2, shake up and down
repeatedly and remove the heat-sink with care. (Fig.3)
Note :
(1) The silicone sheet is stuck on the back
of the heat-sink, and if it tears off forcibly,
there is a possibility of damaging the data
TCP tips.
(2) Do not give stress to the fin of the heat sink and data TCP.
(3) Hold not the fin of the heat-sink but the
base board. (Fig.4)
Fig. 4
(No.52090C)7
Page 8
■CONFIRMING REFERENCE VOLTAGE
Each PDP panel has the characteristic voltage value.
In the adjustment after fix or exchange of a PW board,
this voltage value is used as reference.
You can get it from the vendor's web site on the Internet.
1. Getting the characteristic voltage value of the PDP panel
1.1 Access the following address by the Web browser of
your PC.
http://203.126.119.92/necpd/
1.2 After [NEC-ITLS] screen is displayed, click "Click here
to log on to NPD". (Fig. 1)
1.3 Type the following user name and password into the
dialog box and click "Enter" button. (Fig. 2)
Username: JVCJPN01
Password: jvckoseki (lower-case)
1.4 After [WELCOME TO NEC-ITLS] is displayed (Fig. 3),
click the "Voltage" icon in the "Enquiry" holder on the
upper left part of the window. (Fig. 4)
1.5 After [VOLTAGE ENQUIRY] is displayed (Fig. 5), enter
the panel ID number, which is shown on the panel
(refer to page 2), into the dialog box and click "GO".
Fig. 1
1.6 Then, the characteristic voltage value will be displayed.
(Fig. 6)
Fig. 5
Fig. 2
Fig. 3
8(No.52090C)
Fig. 6
Fig. 4
Page 9
■ADJUSTMENTS
Item
Vsw / -Vw
VOLTAGE
ADJUSTMENT
Measuring
instrument
Test point
DC voltmeterTP328 (Vsw)
TP330 (-Vw)
GND
[HIGH VOLTAGE
PWB]
Adjustment partDescription
VR2 (Vsw)
VR4 (-Vw)
[HIGH VOLTAGE
PWB]
(1) Measure the voltage between TP328 and
GND on the HIGH VOLTAGE PWB.
(2) Adjust the voltage same as the reference
data of Vsw shown in web site by VR2.
※The adjustment accuracy is within ±0.5V.
(3) Measure the voltage between TP330 and
GND on the HIGH VOLTAGE PWB.
(4) Adjust the voltage same as the reference
data of -Vw shown in web site by VR4.
※The adjustment accuracy is within ±0.5V.
VR4(-Vw)
VR2(Vsw)
TP328(Vsw)
TP330(-Vw)
Vbw / Vp
VOLTAGE
ADJUSTMENT
DC voltmeterTP327 (Vbw)
TP329 (Vp)
TP330
GND
[HIGH VOLTAGE
PWB]
VR1 (Vbw)
VR3 (Vp)
[HIGH VOLTAGE
PWB]
VR3 (Vbw)
VR1 (Vp)
(1) Measure the voltage between TP329 and
TP330 on the HIGH VOLTAGE PWB.
(2) Adjust the voltage same as the reference
data of Vbw shown in web site by VR3.
※The adjustment accuracy is within
±0.5V.
(3) Measure the voltage between TP327 and
GND on the HIGH VOLTAGE PWB.
(4) Adjust the voltage same as the reference
data of Vp shown in web site by VR1.
※The adjustment accuracy is within ±1.5V.
TP327(Vp)
TP329(Vbw)
TP330
(No.52090C)9
Page 10
■PARTS LIST
5
PDP UNIT
2
1
6
Ref No.CODE
1
2
3
4
5
6
7
8
8
AA, CA, DA
AA, CA, DA
AA, CA, DA
AA, CA, DA
AA, CA, DA
AA, CA, DA
AA, CA, DA
AA, CA
ABCDEFGHIJKLMNOP
Parts No.
NE-9S899452
NE-9S899418
NE-9S899597
NE-9S899269
NE-9S899271
NE-9S899358
NE-9S899276
NE-9S899281
NE-9S899619
NE-9S899412
NE-9S899620
NE-9S899260
Heat-sink
3
Parts name
HIGH VOLTAGE PWB
COMMON BRANCH PWB
SIGNAL RELAY PWB
SIGNAL RELAY PWB
COMMON PWB
SCAN RELAY PWB
SCAN RELAY PWB
DIGITAL PWB
4
Latest version
01C
03A
01B
01B
01B
01A
01E
01E
08A-02
08A-04
08A-06
02A-02
7
Compatible version
01A
(left)
(right)
(upper)
(lower)
08A-00, 08A-01
01A-01, 01A-02, 02A-01
DA
NOTE : (1)Please check a code number with the seal stuck on the rear side
of the PDP panel.
(2)Version is indicated by the seal stuck on each PW board.
NE-9S899436
NE-9S899493
NOTES AT THE TIME OF PW BOARD EXCHANGE
It will become the cause of failure if dust adheres to the inside of a connector, or a flat wire and
a point-of-contact part.
When the PW board is exchanged, be careful of the dust and dirt of the inside of a connector, or
a flat wire and a point-of-contact part enough.
10(No.52090C)
02A-05
02A-06
01A
FK2600686
The written example of
the seal on a PWB
Indication of Version
Page 11
(No.52090C)11
Page 12
Victor Company of Japan, Limited
AV & MULTIMEDIA COMPANY VIDEO DISPLAY CATEGORY 12, 3-chome, Moriya-cho, kanagawa-ku, Yokohama, kanagawa-prefecture, 221-8528, Japan
(No.52090C)
Printed in Japan
WP
C
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.