SERVICE MANUAL
PDP COLOUR TELEVISION
PD-42D30ES
PD-42D30ES/A
Supplementary
BASIC CHASSIS
MK
These models corresponded to the printed circuit board exchange in the PDP panel. Therefore, this service manual describes only the information relevant to it.
For details other than those described in this manual, please refer to the PD-42D30ES service manual (No.52090 2003/03), PD-42D30ES/A service manual (No.52090B 2003/06).
1.CONFIRMING THE MODEL NAME, SERIAL NUMBER, ID NUMBER, AND CODE NUMBER 2
2.MAIN PARTS LOCATION 2
3.INSPECTION OF COMPONENTS ON THE PW BOARD 3
4.DISASSEMBLY PROCEDURE 6
5.CONFIRMING REFERENCE VOLTAGE 8
6.ADJUSTMENTS 9
7.PARTS LIST 10
NOTES AT THE TIME OF PW BOARD EXCHANGE
It will become the cause of failure if dust adheres to the inside of a connector, or a flat wire and a point-of-contact part.
When the PW board is exchanged, be careful of the dust and dirt of the inside of a connector, or a flat wire and a point-of-contact part enough.
COPYRIGHT © 2004 Victor Company of Japan, Limited
No.52090C
2004/6
■CONFIRMING MODEL NAME, SERIAL NUMBER, ID NUMBER AND CODE
NUMBER
NOTE : The panel's ID number is used when you reference the characteristic voltage value of the panel on web site.
PANEL ID No. 212211041621
(12 figures)
Voltage and CODE No.
SERIAL NO. |
Model name and serial No. |
|
|
||
211200192 |
NEC NP42D2MF01AA |
|
Vd=65V |
211200192 |
|
Vs=190.1V |
******************* |
|
CODE AA-01 |
******************* |
|
For example |
******************* |
|
For example |
||
CODE : AA |
||
Model : NP42D2MF01AA |
||
|
||
|
Serial No. : 211200192 (9 figures) |
|
SCAN RELAY PWB(upper) |
|
|
COMMON PWB |
|
Flexible cable |
|
|
|
Scan-side A |
|
Flexible cable |
COMMON BRANCH PWB |
Flexible cable |
|
Common-side A |
HIGH VOLTAGE |
||
Scan-side B |
|||
|
|||
Flexible cable |
PWB |
|
|
|
|
||
Common-side B |
|
|
Flexible cable |
DIGITAL PWB |
Common-side C |
SIGNAL RELAY PWB(left) |
SIGNAL RELAY PWB(right) |
|
Heat-sink |
A B C D E F G |
H I J K L M N O P |
Flexible cable
Scan-side C
Flexible cable Scan-side D
SCAN RELAY
PWB(lower)
2(No.52090C)
Diagnose the PW board in PDP unit by checking defects based on the following items.
1. Inspection of fuses
Measure the resistance of each fuse with a circuit tester, and check OK or NG.
1.1 Glass fuses (F301, F302) on the HIGH VOLTAGE PWB |
1.2 Chip fuse (FU801) on the DIGITAL PWB |
301
302
OK: Short |
OK: Short |
NG: Open |
NG: Open |
|
801 |
1.3 Fuse resistances (R10, R4, R6) and chip fuse (R20) on the HIGH VOLTAGE PWB
R4 |
|
R4 |
|
R10 |
R20 |
OK: Approx. 2.2Ω |
|
NG: Open |
|||
|
|
R6
1.5 Fuse resistance (R1) on the HIGH VOLTAGE PWB
|
R1 |
|
OK: Approx. 2.2Ω |
R1 |
NG: Open |
1.7 Fuse resistance (R90) on the HIGH VOLTAGE PWB
1.4Fuse resistances (R7, R3) and chip fuse (R9) on the HIGH VOLTAGE PWB
R7
|
R3 |
OK: Approx. 2.2Ω |
|
NG: Open |
|
|
|
|
|
|
R3 |
|
|
OK: Approx. 2.2Ω |
R7 |
|
NG: Open |
R9
R9 OK: Approx. 10Ω
NG: Open
1.6 Fuse resistance (R2) on the HIGH VOLTAGE PWB
R2
R2 OK: Approx. 2.2Ω
NG: Open
|
R90 |
|
OK: Approx. 2.2Ω |
R90 |
NG: Open |
(No.52090C)3
2. Inspection of data ICs
According to the following procedures, measure with a circuit tester and check OK or NG.
Check the pin 1 or pin 2 of the connector [CN12] on the SIGNAL RELAY PWB (right).
OK: Open
NG: Short
Detach the connector [CN12] on the SIGNAL RELAY PWB (right) and check the conduction between the pin 1 (or pin 2) and the ground.
In case of "short", one of the data ICs connecting the SIGNAL RELAY PWB may be defective, and you should check whether there is any trace of damage on the data IC's surface after removing the heat-sink on the data IC.
3. Inspection of power IC
According to the following procedures, measure with a circuit tester and check OK or NG.
The allocation of power IC to be checked is shown below.
HIGHT VOLTAGE PWB
PH2203F
4(No.52090C)