JVC PD-42D30ES, PD-42D30ES/A Service Manual

SERVICE MANUAL
PDP COLOUR TELEVISION
52090200303
PD-42D30ES PD-42D30ES/A
Supplementary
These models corresponded to the printed circuit board exchange in the PDP panel. Therefore, this service manual describes only the information relevant to it. For details other than those described in this manual, please refer to the PD-42D30ES service manual (No.52090 2003/03), PD-42D30ES/A service manual (No.52090B 2003/06).
BASIC CHASSIS
MK
1. CONFIRMING THE MODEL NAME, SERIAL NUMBER, ID NUMBER, AND CODE NUMBER
2. MAIN PARTS LOCATION
3. INSPECTION OF COMPONENTS ON THE PW BOARD
4. DISASSEMBLY PROCEDURE
5. CONFIRMING REFERENCE VOLTAGE
6. ADJUSTMENTS
7. PARTS LIST
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
NOTES AT THE TIME OF PW BOARD EXCHANGE
It will become the cause of failure if dust adheres to the inside of a connector, or a flat wire and
a point-of-contact part.
When the PW board is exchanged, be careful of the dust and dirt of the inside of a connector, or
a flat wire and a point-of-contact part enough.
・・・・・・・・・・
2
2
3
6
8
9
10
COPYRIGHT © 2004 Victor Company of Japan, Limited
No.52090C
2004/6

CONFIRMING MODEL NAME, SERIAL NUMBER, ID NUMBER AND CODE NUMBER

NOTE : The panel's ID number is used when you reference the characteristic voltage value of the panel
on web site.
PANEL ID No. 212211041621
(12 figures)
Voltage and CODE No.
SERIAL NO.
211200192
Vd=65V
Vs=190.1V
CODE AA-01
For example
CODE : AA
Model name and serial No.
NEC NP42D2MF01AA 211200192
******************* ******************* *******************
For example
Model : NP42D2MF01AA Serial No. : 211200192 (9 figures)

MAIN PARTS LOCATION

COMMON PWB
Flexible cable Common-side A
Flexible cable Common-side B
Flexible cable Common-side C
SIGNAL RELAY PWB(left)
A B C D E F G H I J K L M N O P
COMMON BRANCH PWB
DIGITAL PWB
SIGNAL RELAY PWB(right)
Heat-sink
SCAN RELAY PWB(upper)
HIGH VOLTAGE PWB
Flexible cable Scan-side A
Flexible cable Scan-side B
Flexible cable Scan-side C
Flexible cable Scan-side D
SCAN RELAY PWB(lower)
2(No.52090C)

INSPECTION OF COMPONENTS ON THE PW BOARD

Diagnose the PW board in PDP unit by checking defects based on the following items.
1. Inspection of fuses
Measure the resistance of each fuse with a circuit tester, and check OK or NG.
1.1 Glass fuses (F301, F302) on the HIGH VOLTAGE PWB 1.2 Chip fuse (FU801) on the DIGITAL PWB
F301
OK: Short NG: Open
F302
FU801
OK: Short NG: Open
1.3 Fuse resistances (R10, R4, R6) and chip fuse (R20) on the HIGH VOLTAGE PWB
R10 OK: Approx. 2.2Ω NG: Open
R10
R4
R20
R4 OK: Approx. 2.2Ω NG: Open
R6
R6
OK: Approx. 2.2Ω NG: Open
R20 OK: Approx. 10Ω NG: Open
R1 OK: Approx. 2.2Ω
R1
NG: Open
1.4 Fuse resistances (R7, R3) and chip fuse (R9) on the HIGH VOLTAGE PWB
R7
R3
OK: Approx. 2.2Ω NG: Open
R3 OK: Approx. 2.2Ω
R7
NG: Open
R9
R9
OK: Approx. 10Ω NG: Open
1.6 Fuse resistance (R2) on the HIGH VOLTAGE PWB1.5 Fuse resistance (R1) on the HIGH VOLTAGE PWB
R2
R2 OK: Approx. 2.2Ω NG: Open
1.7 Fuse resistance (R90) on the HIGH VOLTAGE PWB
R90 OK: Approx. 2.2Ω
R90
NG: Open
(No.52090C)3
2. Inspection of data ICs
According to the following procedures, measure with a circuit tester and check OK or NG.
Check the pin 1 or pin 2 of the connector [CN12] on the SIGNAL RELAY PWB (right).
OK: Open NG: Short
Detach the connector [CN12] on the SIGNAL RELAY PWB (right) and check the conduction between the pin 1 (or pin 2) and the ground. In case of "short", one of the data ICs connecting the SIGNAL RELAY PWB may be defective, and you should check whether there is any trace of damage on the data IC's surface after removing the heat-sink on the data IC.
3. Inspection of power IC
According to the following procedures, measure with a circuit tester and check OK or NG.
The allocation of power IC to be checked is shown below.
HIGHT VOLTAGE PWB
PH2203F
4(No.52090C)
Loading...
+ 8 hidden pages