JVC CamiFlex FG-CAM-F4/U, CamiFlex FG-CAM-N4/U, CamiFlex FG-CAM-L4/U User Manual

Page 1
Page 2
Table of contents
1 INTRODUCTION ............................................................................... 4
1.1 CAUTIONSAFETY INSTRUCTIONS................................................................................4
1.2 SERVICES INFORMATION AND CONTACT..........................................................................5
1.3 WASTE ELECTRICAL & ELECTRONIC EQUIPMENT (WEEE)...............................................5
1.4 RESTRICTION OF HAZARDOUS SUBSTANCES (ROHS).......................................................5
1.6 EMC AND SAFETY...................................................................................................5
1.7 BASE UNIT – HEAD UNIT..........................................................................................6
1.8 CAMI-VL ADAPTER...................................................................................................7
2 INSTALLATION ................................................................................ 8
2.1 RACK MOUNT - BASE UNIT.........................................................................................8
2.2 HEAD UNIT OVERVIEW...............................................................................................8
2.3 BASE UNIT OVERVIEW...............................................................................................9
2.4 HEAD UNIT SHOOTING POSITION.................................................................................10
2.4.1 F
IBRE ROCKING SYSTEM
....................................................................................................10
2.4.2 T
ALLY
..........................................................................................................................10
2.5 CAMI-VL MOUNTING...............................................................................................11
3 OPERATION ................................................................................... 12
3.1 POWER UP...........................................................................................................12
3.2 DC IN................................................................................................................12
3.3 DC OUT............................................................................................................12
3.4 HEADSET: AUDIO SETTINGS – HEAD UNIT...................................................................13
3.5 HEADSET LIST........................................................................................................13
3.6 AUDIO/HEADSET....................................................................................................14
3.7 INTERCOM.............................................................................................................14
3.8 GENLOCK.............................................................................................................15
3.9 SDI....................................................................................................................15
3.10 REMOTE – RS232/RS422 (REMOTE 1)..................................................................15
3.11 REMOTE – ETHERNET/USB (REMOTE 2)..................................................................15
3.12 REMOTE – RS-232 (TTL REMOTE 3)....................................................................16
3.13 REMOTE – LANC (REMOTE 4)..............................................................................16
4 CONNECTORS PINOUT ................................................................. 17
4.1 BASE UNIT – PINOUT CONNECTORS...........................................................................17
-2-
CamiFlex Base Unit – Head Unit
Page 3
4.1.1 B
ASE UNIT
– R
EMOTE
1 – S
ERIAL CONNECTION
....................................................................17
4.1.2 B
ASE UNIT
– R
EMOTE
2 – E
THERNET
(USB ON H
EAD UNIT
)..................................................17
4.1.3 B
ASE UNIT
– R
EMOTE
3 – S
ERIAL CONNECTION
....................................................................17
4.1.4 B
ASE UNIT
– R
EMOTE
4 – LANC – S
ERIAL CONNECTION
.......................................................18
4.1.5 B
ASE UNIT
– T
ALLY CONNECTION
.......................................................................................18
4.1.6 B
ASE UNIT
– I
NTERCOM
IN
CONNECTION
..............................................................................19
4.1.7 B
ASE UNIT
– I
NTERCOM
OUT
CONNECTION
..........................................................................19
4.1.8 B
ASE UNIT
– H
EADSET
IN/OUT
CONNECTION
......................................................................19
4.2 HEAD UNIT – PINOUT CONNECTORS...........................................................................20
4.2.1 H
EAD UNIT
– R
EMOTE
/USB/LANC
CONNECTIONS
................................................................20
4.2.2 H
EAD UNIT
– I
NTERCOM
IN/OUT
CONNECTION
.....................................................................21
4.2.3 H
EAD UNIT
– H
EADSET
IN/OUT
CONNECTION
......................................................................21
4.2.4 H
EAD UNIT
– DC IN
CONNECTION
.....................................................................................22
4.2.5 H
EAD UNIT
– DC OUT
FOR CAMERA CONNECTION
...............................................................22
4.2.6 H
EAD UNIT
EXTERNAL TALLY CONNECTION IN FRONT OF HEAD UNIT
.........................................22
5 TECHNICAL SPECIFICATIONS ..................................................... 23
5.1 POWER................................................................................................................23
5.2 VIDEO INPUT AND OUTPUT.........................................................................................23
5.3 VIDEO SIGNALLING..................................................................................................24
5.4 AUDIO/REMOTE.....................................................................................................24
6 ANNEX ............................................................................................ 25
6.1 CAMERA ACCESSORIES.............................................................................................25
-3-
CamiFlex Base Unit – Head Unit
Page 4
1 INTRODUCTION
1.1 Caution – safety instructions
Please, read these instructions and heed all warnings.
- Do not use this apparatus near water.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- For a full warranty, only use attachments/accessories specified by the manufacturer.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
- To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
- This device has to be installed by qualified personnel who knows the usual safety procedures and also follows the recommendations listed in this manual.
- The Base Unit chassis MUST be connected to a power supply with a proper grounding. This power connector (IEC 320) is the main connector for the network disconnection and must be easily accessible.
- Both Base Unit and Head Unit must be connected together thanks to hybrid fiber. Connection Base Unit or Head Unit to another equipment can cause failure and such use may cancel the guarantee.
- The mechanical ground of the equipment must be grounded. It is necessary to use an AC cord with Earth as the one supplied. If you choose to use another power cord, make sure it is appropriate.
100-240V ~ 50/60Hz 1A max
- Real consumption is depending on the power camera need: Lowest consumption value is around
0.3A
- Do not open the equipment when power supply is connected, otherwise there is a risk of electric shock and death.
Camera does not allow to be powered off by unpluging the DC IN but must be powered down thanks to camera switch off first. Turning off the equipment is done with the front panel button.
FOUGEROLLE will not be responsible of any accident to a person or any damage to the equipment after use of the product without following these safety recommendations. Such use may cancel the guarantee.
In accordance with current standards, this unit is equipped with a unipolar protection by fuse.
F4AH 5x20
IEC 127
This means that a voltage is always present in the equipment when the power cord is connected to AC power. Do not remove the cover of the equipment without unplug the power cord.
-4-
CamiFlex Base Unit – Head Unit
Page 5
1.2 Services information and Contact
For any question or support use the following contact:
FOUGEROLLE Rue de la Longueraie 35520 MELESSE FRANCE
Tel :+33 (0)2 99 66 08 17 sales @fougerolle-fr.com www.fougerolle-fr.com
1.3 Waste Electrical & Electronic Equipment (WEEE)
This symbol indicate that this product should not be disposed of with household waste, such as specify the WEEE European Directive (2012/19/EU) and the laws in your country.
This product must be entrusted to a designated collection point, for example, every time you buy a new similar product or to a collection point for agree recycling the electrical equipment or electronic (EEE). Inappropriate treatment treating this type of waste is likely to have impacts on environment and human health due to the presence of potentially hazardous substances generally associated with electrical or electronic equipment. Your cooperation to the correct disposal of this product will increase the efficient use of natural resources. For further information about recycling this product, please contact your local services, your ECO­organization or the local authorities.
1.4 Restriction of Hazardous Substances (RoHS)
This product is compliant with directive 2012/19/UE, restricts the use of the following six substances:
- Lead (Pb)
- Mercury (Hg)
- Cadmium (Cd)
- Hexavalent chromium (Cr6)
- Polybrominated biphenyls (PBB)
- Polybrominated diphenyl ether (PBDE)
1.5 Guaranties
A product is faulty if it does not comply with the given description in this manual. Duration of the guaranty is 3 years for this product against all hidden defects. The warranty does not include the return shipping costs, degradations of any kind, consequences due to wrong uses of the product against the recommendations found in this manual and cable made by the customer.
1.6 EMC and Safety
This product meets all relevant CE: EMC TESTS REPORT according to the standard(s):
- EN 55032: 2012
- EN 55103-2: 2009
- EN 61000-3-2: 2014
- EN 61000-3-3: 2013 Safety according to the standard(s):
- IEC 60065:2001 (Seventh Edition) + A1:2005 + A2:2010
-5-
CamiFlex Base Unit – Head Unit
Page 6
1.7 Base Unit – Head Unit
The FG-CAM equipment (also refered as Camiflex in this document) can extend your camera over single mode hybrid fiber up to 200m (for higher distances, please contact us). It is composed of a base unit located on the Camera Control Unit (CCU) side, while the Head unit is co-located with the camera. The Head Unit can be mounted either between the tripod and the camera using a cartoni quick release set option, or between the camera and its battery using the Vlock docking option. Compatible with all JVC cameras, this product supports multiple data communication (TTL Serie, RS232, RS422, LANC) for remote control.
Features:
• 1 x 3G/HD SDI from Head to Base unit
• 1 x 3G/HD SDI from Base to Head unit
• 1 x Genlock from Base to Head unit
• 2 x Tally (Preview / On Air ) integrated on the front of the Head Unit, plus external Tally output via a jack connector
• 1 x RS-232 / RS-422 configurable + Remote Power: remote 1
• 1 x USB/Ethernet: remote 2 (/U option)
• 1 x RS-232 (TTL remote 3) + Remote Power
• 1 x LANC (remote 4) + Remote Power
• 1 x DC OUT 13.2V to power the camera (up to 40 watts @ 200 meters, contact us if more output power is required)
• 1 x Single mode hybrid fiber connector
• 1 x Intercom link
• 1 x Microphone/headphone, configurable headset levels thanks to push button on Head Unit
• 1 x DC IN from +8V to +24V for local FG-CAM powered locally (allows to use Tactical Fiber up to 10Km distance) Warning: power supply to remote controllers is available directly from the RS connector be careful to not connect directly the RS port to a computer (See connector PINOUT for details) on CCU side
-6-
CamiFlex Base Unit – Head Unit
Page 7
1.8 Cami-VL adapter
The Cami-VL adapter can be used to lock the Head Unit between the camera and its battery.
Several ways to use this option:
- If you use Tactical Optical Fiber (or big length of hybrid optical fiber), there will be no power available to power both Head unit, camera and accessories. In this case, a battery can be used to power the Camera by using the Cami-VL adapter (see picture below). In this case, the Head Unit can be powered through an external cable that connects the Head Unit DC IN to the DTAP DC output on the Cami_VL.
- If you have an hybrid fiber, power supply is available on the Head Unit DC OUT. In this case the battery is not required and the Head Unit can power the camera by using an external cable connected between the Head Unit DC OUT and the external DC input of the Camera.
See installation instructions in Cami-VL mounting section
-7-
CamiFlex Base Unit – Head Unit
Page 8
2 INSTALLATION
2.1 Rack mount - Base Unit
The equipment is designed to be installed in a standard 19" rack or any other support. The equipment should be placed away from wet projections, with an operating temperature between +5°C and +40°C. The mounting of the equipment in the rack should be such that a hazardous situation may not be completed due to an abnormal mechanical load. Account must be taken for the connection of the equipment to the power supply and the effect of possible overload protection against overcurrent and power cables. A study of the characteristics of the equipment must be made. It is necessary to check the reliability of the grounding of the equipment especially for shunt connection. Special extended temperature range products can be produced on customer request. All equipment connections are done from the rear panel. The video cables shall not weigh too heavily on the connectors. The earth connection (bolt with nut) must be connected to the earth of rack.
2.2 Head Unit overview
-8-
CamiFlex Base Unit – Head Unit
Page 9
2.3 Base Unit overview
Model: FG-CAM-F4/U, FG-CAM-N4/U, FG-CAM-L4/U /U option: Base Unit with standard RJ45 Ethernet cable and Head unit with LANC+USB cable.
-9-
CamiFlex Base Unit – Head Unit
AC power
input
Optical Hybrid connection
GENLOCK from Global Generator
SDI OUT to Switcher SDI IN
SDI IN from Switcher SDI OUT
LANC
(MiniJack
2.5mm 3p)
Intercom IN
(XLR3p F)
Headset (XLR 5p)
Intercom OUT
(XLR3p M)
Remotes 1&2
(SubD9 F)
Remotes 3
(MiniDIN 6p F)
RJ45 Ethernet
With Loop
LED green :
- signal present
FG-CAM-F4 (Fischer)
FG-CAM-N4 (Neutrik)
FG-CAM-L4 (Lemo)
Optical option :
Tally A&B (SubD9 M)
Page 10
2.4 Head Unit shooting position
When Head Unit is located under the camera, the following items can be used
2.4.1 Fibre rocking system
The optical connector can be pull out of the Head Unit in order to release the connector and thus guide the fibre down to about 45°.
- To use the system, you need to plug the fibre on Head Unit, then pull gently the connector toward you to tilt it down.
- To replace the connector, just push it back in the Head Unit.
Rocking system
2.4.2 Tally
Tally display is present on top of the Head Unit allowing the cameraman to see whether the signal is on air or not.
-10-
CamiFlex Base Unit – Head Unit
Page 11
2.5 Cami-VL mounting
Inserting the Head Unit inside the Cami-VL V-Lock adapter:
Fasten the set using the 4 crews. Be careful, those screws are countersunk head M3x10. Other screw MUST NOT be used.
-11-
CamiFlex Base Unit – Head Unit
Page 12
3 OPERATION
3.1 Power Up
Camera should be switch ON after Base Unit and OFF before. During the product power up, Tally and Fibre LEDs are blinking in orange indicating the product is booting up. This can take a few seconds. During the system boot, the fibre LED is lighted in yellow during 2 seconds then switch off if the fibre is correctly connected. If the fibre LED blinks in red, this means there is a connection problem between Base Unit and Head Unit.
3.2 DC IN
Head Unit can be powered in 2 ways:
a) Through a Hybrid Fibre: the power supply conveyed on the Hybrid Fibre (48V) is internally converted by Head Unit for internal and external need (13.2V DC OUT - see next section).
Hybrid
Fiber
100-240V~
DC OUT
13.2V 40W
Base Unit Head Unit
Head unit can also be powered locally to give power redundancy
Hybrid
Fiber
100-240V~
DC IN 12V
Base Unit Head Unit
b) Through local power supply: Head Unit is powered by DC IN connector (From +8V to +24V IN). In such case DC OUT is unused.
Tactical
Fiber
100-240V~
DC IN 12V
Base Unit Head Unit
3.3 DC OUT
The Head Unit provide DC OUT in order to power the Camera + accessories. This output is active only when using a Hybrid Fibre The certified maximum output power is 40W under 13.2V at 200 meters.
-12-
CamiFlex Base Unit – Head Unit
Page 13
3.4 Headset: Audio settings – Head Unit
Several audio settings are available on the head unit:
- push "+" or "-" to adjust the headphone volume.
- push "MIC" and then "+" or "-" to adjust the microphone volume.
- Talk function: the "Talk" LED lights up when the microphone is enabled. 2 modes are available: Mode 1: Push "Talk" and hold the button to set the microphone (PushToTalk)
Release the button to disable the microphone
Mode 2: Push "Talk" without holding the button to enable the microphone (ON/OFF)
Push "Talk" without holding the button to disable the microphone
Mode ½ can be changed by pushing simultaneous "MIC" and "Talk" buttons. If needed, it is possible to recall default settings by pressing simultaneously "Talk", "-" and "+" buttons during 5 seconds (LED flashing). LED will then remain still to indicate that factory settings has been applied. By default, the factory settings are Mode1 (PushToTalk) with medium audio level. Settings are saved automatically 10 seconds after each change, and are recalled after each new boot.
3.5 Headset list
Headsets needs XLR 5-points and Female connector to be plugged on to the Head Unit. Dynamic microphone is needed.
Here is a short list of compliant Headset with the Head unit. Feel free to contact us if your desired headset is not in this list.
Brand Model
RTS
PH-44R5 PH-88R5 PH-1 A5M PH-3 A5M HR-1 A5M HR-2 A5M
Clearcom
CC-110-X5 CC-220-X5 CC-300-X5 CC-400-X5
Bayerdynamic
DT108 with K 109.38 option DT109 with K 109.38 option DT280 with K 190.39 or K 190.41 option DT290 with K 190.39 or K 190.41 option
-13-
CamiFlex Base Unit – Head Unit
Page 14
3.6 Audio/Headset
Analog balanced audio is transmitted over fibre
-
+
+
-
+15V
-15V
IN+
IN-
Audio input
-
+
+15V
-15V
OUT+ OUT-
Audio output
Audio
Over Fiber
Headset
-
+
+15V
-15V
10K
Loud Speaker
X
-
+
+5V
-5V
MIC
10K
Hybrid
Fiber
+
­+
-
+
­+
-
Line level
Base Unit
Head Unit
IN+ IN­GND OUT+ OUT-
Headset
GND MIC GND L+ R+
Headset
XLR5
XLR5
3.7 Intercom
4 wires intercom connection:
4 wires intercom connection with 3 Head units:
Hybrid
Fiber
Base Unit
Head Unit
+
-
+
­+
-
GND OUT+ OUT­IN+ IN-
Headset
GND MIC GND L+ R+
Headset
XLR5
XLR5
Hybrid
Fiber
Head Unit
+
-
GND MIC GND L+ R+
Headset
XLR5
Hybrid
Fiber
Head Unit
+
-
GND MIC GND L+ R+
Headset
XLR5
+
-
+
-
+
-
+
-
+
­+
­+
-
+
-
300R 300R
300R 300R 300R 300R
Base Unit
+
­+
-
XLR5
Base Unit
+
­+
-
XLR5
GND OUT+ OUT­IN+ IN-
Headset
GND OUT+ OUT­IN+ IN-
Headset
-14-
CamiFlex Base Unit – Head Unit
Page 15
If needed, this intercom connection can support Time Code transmission
Hybrid
Fiber
Base Unit
Head Unit
+
-
+
-
IN+ IN­GND OUT+ OUT-
INTERCOM
OUT+ OUT­GND IN+ IN-
INTERCOM
Time Code
Hybrid
Fiber
Base Unit
Head Unit
+
IN+ IN­GND OUT+ OUT-
INTERCOM
OUT+ OUT­GND IN+ IN-
INTERCOM
Time Code
XLR3 XLR3
HRS6
XLR3 XLR3
HRS6
Note: 2 wires intercoms are not yet supported. Connecting a 2 wires intercoms may cause damages to the system.
3.8 Genlock
Genlock is transmitted over CVBS format and supports the insertion of an extra PAL/NTSC video stream (view finder, Teleprompter)
Hybrid
Fiber
PAL NTSC
Base Unit
Head Unit
BNC
Genlock
BNC Genlock
3.9 SDI
A bidirectional SD/HD/3G SDI is available on the product.
Hybrid
Fiber
SDI
Base Unit
Head Unit
BNC SDI In
BNC SDI Out
BNC SDI Out
BNC SDI In
3.10 Remote – RS232/RS422 (remote 1)
Serial communication (any rate up-to 900Kbps) is available thought the system: A specific cable has to be used on Head Unit side (Hirose-20 type) and power can be injected to power the remote control from the Base Unit side.
Hybrid
Fiber
Base Unit
Head Unit
SubD-9
HRS20
With special cable
3.11 Remote – Ethernet/USB (remote 2)
-15-
CamiFlex Base Unit – Head Unit
Page 16
3.12 Remote – RS-232 (TTL Remote 3)
RS-232 communication (TTL level, any rate up-to 900Kbps) is available thought the system: A specific cable has to be used on Head Unit side (Hirose-20 type) and power can be injected to power the remote control from the Base Unit side.
Hybrid
Fiber
Base Unit
Head Unit
MiniDIN6
HRS20
With special cable
MiniDIN6
MiniDIN6
3.13 Remote – LANC (Remote 4)
LANC remote communication is available thought the system: A specific cable has to be used on Head Unit side (Hirose-20 type) and power can be injected to power the remote control from the Base Unit side.
Hybrid
Fiber
Base Unit
Head Unit
Jack
HRS20
With special cable
Jack
Jack
-16-
CamiFlex Base Unit – Head Unit
Page 17
4 Connectors Pinout
4.1 Base Unit – Pinout Connectors
4.1.1 Base Unit – Remote 1 – Serial connection
Remote connection is managed through RS232 or RS-422. For RS-232 configuration, a short-circuit must be done between Pin 4 & Ground (Pin 1 or Pin5). Baud rate can be up to 700K baud without any specific configuration.
Pin SubD9-F - Remote RS-232 SubD9-F - Remote RS-422(*)
1 - (Do not used) 1 Ground
2 OUT : TxD 2 OUT : RS_TX-
3 IN : TxD 3 IN : RS_RX+
4 RS-4xx (short-circuit to ground) 4 - (Not used)
5 Ground 5 Ground
6 - (Not used) 6 OUT : RS_TX+
7 - (Not used) 7 - (Not used)
8 - (Not used) 8 IN : RS_RX-
9 - (Not used) → +12V 9 +12V
* Note: Differential RS-422 inputs includes 120R termination resistors
4.1.2 Base Unit – Remote 2 – Ethernet (USB on Head Unit)
Ethernet (RJ45) on Base side is used to connect a remote control or other to the camera through a dedicated Ethernet or USB cable on Head unit side.
4.1.3 Base Unit – Remote 3 – Serial connection
Serial control can be sent through RS-232(TTL level). Baud rate can be up to 9600 baud.
Pin MiniDIN 6p-F - Remote RS232 (TTL level)
1 Ground
2 IN : RS3_RM/CTL
3 Ground
4 OUT : RS3_SID2
5 IN : RS3_SID1
6 OUT : +12V
-17-
CamiFlex Base Unit – Head Unit
Female connector
Page 18
4.1.4 Base Unit – Remote 4 – LANC – Serial connection
Bi-directional serial communication is compliant with LANC protocol (9600 baud)
Pin Mini Jack 2.5mm 3p - LANC
1 LANC
2 +6V
3 GND
4.1.5 Base Unit – Tally connection
Tally input pins need to be in short-circuit with ground to turn ON the Tally LED:
- Tally A: Red light
- Tally B: Yellow light
- Both A&B Tally: Red light Pin SubD9-M – Tally (A&B)
1 Not used
2 Not used
3 Not used
4 Not usedn
5 Not used
6 Tally A – Red
7 Ground
8 Tally B – Yellow
9 Not used
-18-
CamiFlex Base Unit – Head Unit
Page 19
4.1.6 Base Unit – Intercom IN connection
Standard XLR 3p connection:
Pin XLR 3p-F – Intercom IN (Line level)
1 GND
2 IN+
3 IN-
4.1.7 Base Unit – Intercom OUT connection
Standard XLR 3p connection:
Pin XLR 3p-M – Intercom OUT (Line level)
1 GND
2 OUT+
3 OUT-
4.1.8 Base Unit – Headset IN/OUT connection
Pin XLR 5p-F – Headset IN/OUT (Line level)
1 GND
2 OUT+
3 OUT-
4 IN+
5 IN-
-19-
CamiFlex Base Unit – Head Unit
Page 20
4.2 Head Unit – Pinout Connectors
4.2.1 Head Unit – Remote/USB/LANC connections
Pin Hirose 20p-F – Remote
1 IN : - RS1_422_RX-
2 IN : RS1_232_RX RS1_422_RX+
3 OUT : RS1_232_TX RS1_422_TX-
4 OUT : - RS1_422_TX+
5 IN : GND or No connection RS-232: short-circuit to GND
6 Ground configuration for RS1
7 Ground
8 Ground
9 OUT : RS3_SID1
10 IN :RS3_SID2
11 IN :GND or No connection RS-232: short-circuit to GND
12 LANC_Power configuration for RS2
13 Ground
14 Ground
15 OUT : RS3_RM/CTL
16 LANC
17 USB GND
18 USB VCC
19 USB Data +
20 USB Data -
-20-
CamiFlex Base Unit – Head Unit
Page 21
4.2.2 Head Unit – Intercom IN/OUT connection
Pin Hirose 6p-F – Intercom IN/OUT (Line level)
1 GND
2 IN+
3 IN-
4 GND
5 OUT+
6 OUT-
4.2.3 Head Unit – Headset IN/OUT connection
Pin XLR 5p-F – Headset IN/OUT
1 GND
2 Micro
3 GND
4 L+
5 R+
-21-
CamiFlex Base Unit – Head Unit
Page 22
4.2.4 Head Unit – DC IN connection
Pin Hirose 4p-F – DC IN External power
1 Ground
2 Ground
3 From +8V to +24V IN
4 From +8V to +24V IN
4.2.5 Head Unit – DC OUT for Camera connection
Pin Hirose 5p-F – DC OUT
1 GND
2 GND
3 +12V or +13.2V
(*)
4 +12V or +13.2V
(*)
5
Pin5 (*)
(*) Pin5 not connected: Vout=+12V (*) Pin5 connected to GND: Vout=+13.2V
4.2.6 Head Unit – external Tally connection in front of Head Unit
Pin Jack 3.5mm – external Tally
1 GND (not used)
2 GPO (grounded when turn ON LED)
3 +5V out (protected with Fuse) Recommended schematics: Max current: 100mA R depend on LED specification
-22-
CamiFlex Base Unit – Head Unit
R
+5V out
GPO
1 2 3
Page 23
5 Technical specifications
5.1 Power
Physical characteristics (Base Unit case)
1U 19'' rugged stainless steel, 280mm depth
Power consumption: <230W with FAN cooling
Operating temperature: +5 ° C to +40 ° C.
Weight: around 3 kg.
Base Unit - Power supply
100-240V AC 50/60Hz (IEC 320 C14)
Unipolar fuse protection is F4AH 5x20 IEC 127. The mechanical ground of the equipment must be grounded.
Physical characteristics (Head Unit case)
175mm x 215mm x 42mm, with Kodak holder
screw on bottom and tripod lock on top
Power consumption: <10W
Operating temperature: +5 ° C to +40 ° C.
Weight for Lite version: 2 kg approx.
Head Unit - Power supply
By Hybrid fiber or external DC IN:
→ from +8V to +24V <10W
Head Unit - DC Out :
- Max 40W (13.2V)
5.2 Video input and output
SDI Input:
- SD, HD and 3G SDI up to 3 Gbit/s
- Automatic detection of video format
- Cable Equalization up to 100m in 3G-SDI
- 800mVcc nominal level, 500mVcc minimal
- BNC, 75Ω impedance
Loop output:
- Copy of the input signal with cable equalization
- BNC, 75Ω impedance
- Nominal Level: 800mV ± 10%
SDI output (SD, HD and 3G):
- SD, HD and 3G SDI up to 3 Gbit/s
3G-SDI : 2,970Gbit/s (2,970/1,001) – SMPTE
424M
HD-SDI : 1,485Gbit/s (1,485/1,001) –
SMPTE292M
SDI : 270Mbit/s – SMPTE259M
- BNC, 75Ω impedance
- Nominal level: 800mV ± 10%
CVBS analog input (SD only):
PAL & NTSC compliant
- BNC, 75Ω impedance
- Nominal Level: 1V (700mV + sync 300mV)
- Automatic detection of video format
- Automatic gain correction based on the sync pulse (accept a level change of 50 to 160 %)
CVBS analog output (SD only):
- BNC, 75Ω impedance
- Nominal Level: 1V (700mV + sync 300mV)
-23-
CamiFlex Base Unit – Head Unit
Page 24
5.3 Video signalling
LEDs are present near the video connectors.
- Green means valid video signal presence and locked
- Off means no or invalid signal
5.4 Audio/Remote
Head Unit Audio - Headset
Use dynamic microphone
Max input level: -30dBu (25 mV rms)
All headset impedance are allowed.
Audio - Intercom
4 wires - Line level (+22dBm) - 2 wires not
supported
- Audio Level: +24dB maximum (+24dBu = 0dBfs)
- Bandwidth: 20Hz - 20kHz ± 0,1 dB
- Input: 10kΩ, couplage AC
- Output: 50Ω
Remote 1
Signals RS-232/RS422 are compliant with
standard
Warning: on Base Unit, the SubD9 connector
provide +12V DC to power the remote, so direct
connection to a computer is not possible.
Remote 2
Compliant with USB2 standard
Remote 3
RS-232 with TTL level (+5V)
Warning: on Base Unit, the MiniDIN connector
provide +12V DC to power the remote.
Remote LANC
LANC with TTL level (+5V)
Warning: on Base Unit, the MiniJack connector
provide +6V DC to power the remote.
Power Remote on Base Unit
Total current for all remotes power must not
exceed 0.7A
-24-
CamiFlex Base Unit – Head Unit
Page 25
6 ANNEX
6.1 Camera accessories
FGJ2 : Accessories set for JVC HM200/170/LS300 camcoders
Designation Reference
Braket - support (3/8'') CAMI/CART1: CAMI-CART
CamiFlex 12V Jack5.5 FGJ2P: CAMI_JVC-H5J5.5-21cm
CamiFlex 12V Jack5.5 XLR4F FGJ2P1: CAMI_JVC-H5J5.5X4-21cm60cm
CamiFlex LANC RA + USB FGJ2R1: CAMI_JVC-H20J2.5cU2-19cm30cm
BNC-BNC 40cm FGJ2B: CAMI_BB-40cm
FGJ6 : Accessories set for JVC HM600/650 camcoders
Designation Reference
Braket - support (3/8'') CAMI/CART1: CAMI-CART
CamiFlex 12V Jack5.5 FGJ6P: CAMI_JVC-H5J5.5-21cm
CamiFlex 12V Jack5.5 XLR4F FGJ6P1: CAMI_JVC-H5J5.5X4-21cm60cm
CamiFlex LANC RA + USB FGJ6R1: CAMI_JVC-H20J2.5cU2-19cm21cm
BNC-BNC 40cm FGJ6B: CAMI_BB-40cm
FGJ8 : Accessories set for JVC HM850/890 camcoders
Designation Reference
U-adaptor V_Lock to CamiFlex CAMI-VL (see section 2.4)
CamiFlex 13.2V XLR4F FGJ8P: CAMI_JVC-H5X4-49cm
CamiFlex 12V XLR4-F XLR4-F FGJ8P1: CAMI_JVC-H5X4X4-49cm70cm
CamiFlex LANC RA + RS + USB FGJ8R1: CAMI_JVC-H20J2.5MD6U2-43cm40cm56cm
BNC-BNC 40cm FGJ8B: CAMI_BB-40cm
END OF DOCUMENT
-25-
CamiFlex Base Unit – Head Unit
Loading...