Juniper Systems A2 Ethernet Multi Dock User Manual

A2 Ethernet Multi Dock
The A2 Ethernet Multi Dock is a mounting station for up to four Archer 2 and/or Allegro 2 Rugged Handhelds. It provides ethernet ports for networking and a power input jack to apply power to the dock and to charge handhelds.
Ethernet Specications
 10/100 Mbps twisted-pair ethernet
 IEEE802.3 10Base-T / 100Base-TX
 Supports full-duplex and half-duplex
 Ethernet driver software pre-installed on the handheld
Dock Features
1
2
Using the A2 Ethernet Multi Dock
1. The ethernet dock is a freestanding desktop base. It can
also be mounted to a horizontal surface like a desk or shelf. To mount the dock, drill three holes in a horizontal line 10 7/8” (27.65 cm) apart up through the mounting surface. Screw #6-32 screws up into the threaded holes in
the dock’s boom base plate.
Note: The screws should not penetrate the dock more than 1/4”.
2. Handhelds must have a docking I/O module. The lower right side of the module has docking pin contacts as shown below:
If you have a standard I/O module, replace it with a
docking I/O module. Follow the instructions included with the kit.
3. To use an Archer 2 with the dock, install the insert as shown below. This step is not required for the Allegro 2.
3
6
4
1 Handheld backrest and connector protector slot
2 LED indicator: green when the dock has power
3 Docking pins
4 Power input jack: 12VDC power input to power the Ethernet dock
and the handheld(s)
5 Archer 2 insert location (use as needed)
6 Ethernet port (1 of 2): for networking using an ethernet cable and
software. LED indicators:
- Left LED lights amber to indicate that data connection is active
- Right LED lights green when there is a 100 Mbps connection speed
5
Accessories
Included with the Multi Dock
 Archer 2 insert and 2 screws (4 sets)
 AC universal power adapter
 US AC power cord (adapters for international plugs are
available separately from Juniper Systems or your dealer)
 RJ-45 CAT5 twisted-pair 7 foot ethernet cable
Accessories Available Separately
 Docking I/O modules for the handhelds if they are not
factory installed (available from Juniper Systems or your dealer)
 Communication software to communicate with the
handheld over an ethernet network (options include custom software or programs from a third party vendor such as Soti MobiControl, www.soti.net/mobicontrol or Ai rWatch, ww w.a ir-w atch .com)
 Three #6-32 screws to mount the dock to a surface
(optiona l)
4. Aach the AC power cord to the power adapter. Plug
the power cord into an AC power supply and the power adapter into the power input jack on the dock. This provides power to the dock and charges handhelds. The green LED turns on when power is applied.
5. If a handheld has a connector protector, open it to reveal
the connector ports. Pull it back as shown below.
6. To insert a handheld, hold it so the connector ports are
at the boom and the keypad is facing forward. Insert the handheld into the dock as shown below so it is rmly
seated. The handheld automatically turns on.
7. When you insert a handheld into the dock, a red LED on the handheld is illuminated, indicating that it is properly docked and ready to communicate over the network.
8. For networking, use an ethernet cable to connect the dock to an ethernet switch or to an internal network.
9. Use communication software to communicate with the handhelds over an ethernet network. Follow the instructions included with the software.
10. Handhelds can be used when they are in the dock. The keys and display are accessible.
Connecting Docks Together
You can daisy-chain multiple and/or single docks together using the ethernet ports and ethernet cables. For the network installation, consult your network administrator for best
practices. Designs should avoid long chains of more than ve
docks or switches in series (including the upstream network sw itches).
Maintenance and Environmental Issues
The ethernet dock is intended for indoor use only. Tempera­tures should be between 0°C to 50°C. Avoid using the dock in situations where water can enter the connector ports. It is not sealed against water and must be kept dry, although it sheds moisture that is on handhelds when placed into the dock.
Do not touch the docking pins (spring loaded contacts) with conductive items when power is applied to the dock.
Do not drop items on the dock that can damage the pins.
Keep debris o of the docking pins and the connectors to
maintain the best performance.
Battery Warnings
WARNING! These warnings are for the lithium ion rechargeable
!!
baeries in the handheld:
To reduce the risk of re or burns, do not disassemble, crush, puncture, short external contacts, or expose to re.
Do not disassemble or open, crush, bend or deform, puncture, or shred.
Do not modify or remanufacture, aempt to insert foreign objects into the baery, immerse or expose to water or other liquids, expose to re, explosion or other hazard.
Only use the baery for the system for which it is specied
Only use the baery with a charging system that has been qualied with the system per this standard.
Do not short circuit a baery or allow metallic conductive objects to contact baery terminals.
Replace the baery only with another baery that has been qualied with the system.
Use of an unqualied baery may present a risk of re, explosion,
leakage or other hazard.
Promptly dispose of used baeries in accordance with local
regulations.
Baery usage by children should be supervised.
Avoid dropping the baery. If the baery is dropped, especially
on a hard surface, and the user suspects damage, take it to a service center for inspection.
Improper baery use may result in a re, explosion or other
hazard.
Regulatory Information
United States (FCC)
This device complies with Part 15 of the FCC Rules. Operation of
this equipment is subject to the following two conditions:
1. The device may not cause harmful interference.
2. This device must accept any interference received, even if the
interference may cause undesired operation.
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CAUTI ON: Only approved accessories may be used with this
!
equipment. In general, all cables must be high quality and correctly terminated. Chargers approved for this product employ special provisions to avoid radio interference and should not be altered or substituted.
CAUTI ON: Changes or modications to the handheld or dock that
!
are not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
This device complies with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
CE Marking
Products bearing the CE marking comply with the
2004/108/EC (EMC Directive) issued by the Commission
of the European Community.
CE compliance of this device is valid only if powered with/ by a CE-marked wall charger provided by the manufacturer. Compliance with these directives implies conformity to the following standards:
EN 55022 Electromagnetic Interference
EN 55024 Electromagnetic Immunity
Wall Charger Warnings
WARNING! To reduce the risk of personal injury, electrical shock,
!
re or damage to the equipment:
Plug the charger into an electrical outlet that is easily accessible at
all times.
Disconnect power from the equipment by unplugging the wall charger from the electrical outlet.
Do not place anything on the charger cord or any of the other cables. Arrange them so that no one may accidentally step on or trip over them.
Do not pull on a cord or cable. When unplugging the charger from the electrical outlet, pull on the plug, not the cord.
Use only the charger supplied with the dock. Any other external power source can damage your product and void your warranty.
tel: 435.753.1881
web: www.junipersys.com
l
1132 W. 1700 N. Logan, UT 84321
P/N 24595-00. Copyright Nov. 2014 Juniper Systems, Inc. Archer 2 Rugged Handheld and Allegro 2 Rugged Handheld are trademarks of Juniper Systems, Inc. Information is subject to change without notice.