Juniper TCX1000 Quick Start Manual

TCX1000 Inline Amplifier Quick Start Guide
About This Quick Start Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Step 1: Prepare Your Site for the TCX1000-ILA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Step 2: Unpack the TCX1000-ILA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Step 3: Mount the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Step 4: Connect the Grounding Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Step 5: Connect to the Management Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Step 6: Power On the TCX1000-ILA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connecting AC Power to the TCX1000-ILA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connecting DC Power to the TCX1000-ILA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step 7: Perform the Initial Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Power Cable Warning (Japanese) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
NEBS Compliance Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Compliance Statements for EMC Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
European Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Israel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
United States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Requesting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Opening a Case with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
About This Quick Start Guide
This Quick Start Guide contains information you need to install and connect the Juniper Networks TCX1000 Inline Amplifier (ILA). For complete installation instructions, see the TCX1000 Inline Amplifier Hardware Guide at
https://www.juniper.net/documentation/.
WARNING: This Quick Start Guide contains a summary of safety warnings in “Safety Warnings Summary” on page 12.
For a complete list of warnings forthe TCX1000-ILA,including translations,seethe TCX1000Inline Amplifier Hardware Guide at https://www.juniper.net/documentation/.
The Juniper Networks TCX1000 Inline Amplifier is a standalone erbium-doped fiber amplifier (EDFA) with dual AC or DC power supplies.The TCX1000-ILA supports dual optical inline amplification—two functionally separate amplifiers. The TCX1000-ILA provides amplification of a dense wavelength-division multiplexing (DWDM) signal to enable long-distance transmission over fiber-optic cable. The TCX1000-ILA is used in conjunction with the TCX1000-RDM20.
TCX1000 Inline Amplifier Quick Start Guide
Step 1: Prepare Your Site for the TCX1000-ILA
Before installing the TCX1000-ILA, make sure your site meets all power, environmental, and clearance requirements.
Ensure that you have the following parts and tools available to install the TCX1000-ILA:
Four self-tapping 10-24 bolts to secure the chassis and mounting brackets to the rack (provided).
Two power cords with plugs appropriate for your geographical location (provided with the AC model).
Two DC power connectors (provided with the DC model).
19-in. mounting brackets (preinstalled on the chassis).
Grounding lug (provided).
(Optional) 21-in. and 23-in. mounting brackets (provided).
Electrostatic discharge (ESD) grounding strap (not provided).
Screwdriver appropriate for the rack-mounting screws (not provided).
Power cable or cables appropriate for your geographical location available to connect DC power to the TCX1000-ILA (not provided).
Management host, such as a PC laptop, with a serial port (not provided).
Step 2: Unpack the TCX1000-ILA
For detailed instructions on how to unpack the box and verify the parts received for the TCX1000-ILA, see the TCX1000 Inline Amplifier Hardware Guide at https://www.juniper.net/documentation/.
Copyright © 2018, Juniper Networks, Inc.2
g100074
LINEAIN
LINEAOUT
LINEBIN
LINEBOUT
MONAOUT
MONBOUT
CON MGMT
USB
USB
ON/OFF
OSCA
OSCB
PWR
SYS
ALM
TCX1000 Inline Amplifier Quick Start Guide
Step 3: Mount the Chassis
To mount the TCX1000-ILA on two posts or four posts in a rack by using the provided mounting kit (see Figure 1):
NOTE: The 19-inch brackets are attached to the TCX1000-ILA when they are shipped. If you want to attach the
21-inch or 23-inch brackets,unscrewthe 19-inch brackets from the chassis, and attach the 21-inch or 23-inch brackets by using the same screws.
NOTE: This procedure requires two persons. Do not attempt to do it alone.
Figure 1: Installing the TCX1000-ILA on a Rack
1. Attach the ESD grounding strap to your bare wrist and to a site ESD point.
NOTE: Place the rack in its permanent location, allowing adequate clearance for airflow and maintenance, and
secure it to the building structure. If you are mounting multiple units in the rack, mount the heaviest unit at the bottom and mount the others from bottom to top in order of decreasing weight. The TCX1000-ILA weighs 11.7 lb (5.30 kg).
2. Position the TCX1000-ILA in such a manner that the FRUs are next to the hot aisle.
3. Use four mounting screws (and cage nuts and washers if your rack requires them) to attach the brackets to the rack.
4. Tighten the screws.
3Copyright © 2018, Juniper Networks, Inc.
TCX1000 Inline Amplifier Quick Start Guide
Step 4: Connect the Grounding Cable
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, you must connect the chassis to earth ground before you connect it to power. For installations that require a separate grounding conductor to the chassis, use the protective earthing terminal on the TCX1000-ILA chassis to connect to earth ground.
NOTE: An AC-powered TCX1000-ILA gains additional grounding when you plug the power supply in the device into
a grounded AC power outlet by using an AC power cord appropriate for your geographical location. See the “TCX1000-ILA Power System” to see the AC power cord specifications in the TCX1000 Inline Amplifier Hardware Guide.
CAUTION: Before you connect power to the TCX1000-ILA, a licensed electrician must attach a cable lug to the
grounding and power cables that you supply. A cable with an incorrectly attached lug can damage the TCX1000-ILA (for example, by causing a short circuit).
NOTE: Mount the TCX1000-ILA in the rack or cabinet before attaching the grounding lug to the TCX1000-ILA.
Ensure that you have the following parts and tools available:
Grounding cable (not provided)—The grounding cable must be 14–10 AWG (2–5.3 mm²), minimum 90° C wire, or as permitted by the local code.
Grounding lug (provided) for your grounding cable—The grounding lug required is a Panduit LCD6-14BH-L or equivalent.
Two M5-0.8x8 mm screws (provided)—The screws are secured on the chassis when it is shipped.
Screwdriver appropriate for the M5-0.8x8 mm screws.
To connect a grounding cable to the TCX1000-ILA:
1. Connect one end of the grounding cable to a proper site earth ground, such as the rack in which the TCX1000-ILA is mounted.
2. Unscrew the screws that are attached to the chassis.
3. Place the grounding lug attached to the grounding cable over the protective earthing terminal on the chassis (see Figure 2).
Figure 2: Connecting a Grounding Cable to the TCX1000-ILA
4. Secure the grounding lug to the protective earthing terminal with the screws.
5. Dress the grounding cable and ensure that it does not touch or block access to other device components and that it does not
drape where people could trip over it.
Copyright © 2018, Juniper Networks, Inc.4
TCX1000 Inline Amplifier Quick Start Guide
Step 5: Connect to the Management Console
The TCX1000-ILAhasa console port with an RJ-45 connector. Use the console port to connect the device directlytoa management console, such as a laptop, or to a console server.
Ensure that you have an RJ-45 to DB-9 rollover cable available.
NOTE: If your laptop or PC does not have a DB-9 male connector pin and you want to connect your laptop or PC
directly to the TCX1000-ILA, use a combination of the RJ-45 cable and RJ-45 to DB-9 adapter and a USB to DB-9 male adapter. You must provide the cable and adapter.
To connect the TCX1000-ILA to the management console (see Figure 3 or Figure 4):
Figure 3: Connecting the TCX1000-ILA to a Management Console
Figure 4: Connecting the TCX1000-ILA to a Management Console Through a Console Server
NOTE: For instructions to connect to a management Ethernet device see the TCX1000 Inline Amplifier Hardware
Guide. at https://www.juniper.net/documentation/.
Step 6: Power On the TCX1000-ILA
NOTE: The TCX1000-ILA is supplied with two factory-installed power supplies. The power supplies need to be both
AC or both DC.
Connecting AC Power to the TCX1000-ILA on page 5
Connecting DC Power to the TCX1000-ILA on page 7
Connecting AC Power to the TCX1000-ILA
To connect AC power to a TCX1000-ILA:
1. Prevent damage to the equipment caused by ESD, by attaching an ESD grounding strap to your bare wrist and connecting the
strap to an approved site ESD grounding point.
2. Ensure that the power supplies are fully inserted in the chassis and the latches are secure.
3. Insert the coupler end of the power cord into the AC power cord inlet on the AC power supply faceplate (see Figure 5).
5Copyright © 2018, Juniper Networks, Inc.