Juniper QFX3008-I Quick Start Guide

Quick Start Guide
QFX3008-I
IN THIS GUIDE
Step 1: Begin | 1
Step 2: Up and Running | 4
Step 3: Keep Going | 5

Step 1: Begin

IN THIS SECTION
Connect to the Earth Ground and Attach Rear Support Anchors | 3
Connect to Single-Phase AC Power | 3
To install a Juniper Networks QFX3008-I Interconnect device, you need:
Mechanical lift rated for at least 750 lb (340.2 kg) (not provided)
Rack mounting shelf, rear support bracket, and two rear support anchors (provided)
32 mounting screws appropriate for your four-post rack or cabinet (12 to attach the rear support bracket to the rack,
6 to attach the rack mounting shelf to the rack, and 14 to attach the chassis to the rack) (not provided)
Screwdriver appropriate for your rack mounting screws (not provided)
Phillips (+) screwdriver, number 2, to remove and tighten screws
Grounding cable—minimum 2 AWG (33.6mm2), minimum 60º C wire—with appropriate grounding lug (provided) attached
by a licensed electrician
Four screws to secure the rear support anchors to the chassis (provided)
g050166
Six power cords with a plug appropriate for your geographical location and six power cord retainer clips to secure the
cords to the wiring tray (provided)
NOTE: These instructions apply only to a four-post 19-in. rack or cabinet installation and single-phase AC wiring
trays.
2

Mount the QFX3008-I

1. Place the rack in its permanent location, allowing adequate clearance for airflow and maintenance, and secure it to the building structure.
NOTE: If you are mounting multiple units in the rack, mount the heaviest unit at the bottom of the rack and
mount the others from bottom to top in order of decreasing weight.
2. On the rear of each rear rack rail, partially insert a mounting screw 1 U below where you intend to install the chassis.
3. Install the rear support bracket on the rear of the rear rack rails. Rest the bottom slot of the rear support bracket on a mounting screw. The rear support bracket extends toward the center of the rack.
4. Partially insert screws into the open holes in the rear support bracket. Tighten all the screws.
5. On the front of each front rack rail, partially insert a mounting screw 1 U below where you intend to install the chassis.
6. Install the four-post rack mounting shelf on the front rack rails. Rest the front of the four-post rack mounting shelf on the mounting screws you installed on the front rack rails. Rest the back of the four-post rack mounting shelf on top of the rear support bracket.
7. Partially insert screws into the open holes in the four-post rack mounting shelf. Tighten all the screws.
8. Fasten the four-post mounting shelf to the rear support bracket by partially inserting the flat-head screws provided in the accessory kit into the open holes on top of the four-post mounting shelf. Several holes are provided on top of the shelf. Two holes on each side of the shelf will align with the holes in the rear support bracket. Tighten all the screws.
9. Using the mechanical lift, position the device in the rack and install a mounting screw into each of the front mounting flange holes that align with the rack rails.

Connect to the Earth Ground and Attach Rear Support Anchors

3
1. Connect one end of the grounding cable to a proper earth ground, as defined by local electrical codes.
2. Hook the rear support anchors around the bottom rear flange of the mounting shelf so that its holes line up with the grounding lug screw holes at the bottom left and right corner of the chassis rear.
3. Place the grounding lug attached to the grounding cable over one of the rear support anchors, and secure the lug and rear support anchors with the provided UNC 1/4-20 (right side) screws and M6 (left side) screws.

Connect to Single-Phase AC Power

Wiring trays come preinstalled in the chassis. For each wiring tray:
1. Ensure that the wiring tray is fully inserted and latched securely in the chassis.
2. Set the wiring tray power switch to the OFF (O) position.
3. Insert one of the L-shaped clip ends of the power cord retainer clip into the bracket hole on one side of the AC appliance inlet on the wiring tray.
4. Gently pull the other side of the power cord retainer clip outward and secure it in the hole on the opposite side of the AC appliance inlet on the wiring tray.
5. Insert the coupler end of the power cord into the AC appliance inlet.