Juniper PowerConnect J-SRX210, SRX210, SRX210B, SRX210H, SRX210H-POE Quick Start Manual

...
Page 1
SRX210 Services Gateway Quick Start
g031132
g031113
Use the instructions in this quick start to help you connect the SRX210 Services Gateway to your network. For details, see the SRX210 Services Gateway Hardware Guide at http://www.juniper.net/techpubs/a057.html
.
SRX210 Services Gateway Front Panel
Callout Description Callout Description
1 Mini-PIM slot 5 USB ports
2 Power button 6 Console port
3 LEDs (ALARM, POWER,
STATUS, HA, mPIM, EXPCARD)
4 Reset Config button
7 Gigabit Ethernet (0/0 and 0/1) and Fast
Ethernet (0/2 to 0/7) ports
SRX210 Services Gateway Back Panel
SRX210 Services Gateway Models
Device DDR Memory Power over
SRX210B 512 MB No
SRX210H 1 GB No
SRX210H-POE 1 GB Yes
SRX210BE 512 MB No
SRX210HE 1 GB No
SRX210HE-POE 1 GB Ye s
SRX210HE-TAA 1 GB No
SRX210HE-POE-TAA 1 GB Ye s
On the SRX210H-POE, SRX210HE-POE and SRX210HE-POE-TAA models, Power over Ethernet (PoE) of 50 watts is supported across four ports (0/0, 0/1, 0/2, and 0/3).
Note that you must use the following power supply adapters (supplied) for your services gateway:
54V, 150 watts power supply adapters for PoE models
12V, 60 watts power supply adapters for non-PoE models
Connecting and Configuring the SRX Series Device
Follow the instructions to connect and set up the SRX210 Services Gateway to protect your network. Refer to the LEDs on the front of the device to help you determine the status of the device.
Ethernet
Callout Description Callout Description
1 Power supply input 4 Lock for security cable
2 Cable tie holder 5 ExpressCard slot
3 Grounding point
Overview
The SRX210 Services Gateway is a security device that requires the following basic configuration settings to function:
Interfaces must be assigned IP addresses.
Interfaces must be bound to zones.
Policies must be configured between zones to permit or deny traffic.
Source NAT rules must be set.
The device has the following default configuration set when you power it on for the first time. To use the device, you do not need to perform any initial configuration.
Page 2
Factory-Default Settings for Initial Configuration:
g031118
Port Label Interface Security
0/0 ge-0/0/0 untrust client unassigned
0/1 and 0/2 to 0/7
ge-0/0/1 and fe-0/0/2 to fe-0/0/7
Zones
trust server 192.168.1.1/24
DHCP State IP Address
Factory-Default Settings for Security Policies:
Source Zone Destination Zone Policy Action
trust untrust permit
trust trust permit
untrust trust deny
Factory-Default Settings for NAT Rule:
Source Zone Destination Zone Policy Action
trust untrust source NAT to untrust zone
interface
NOTE: Source NAT translates the source address for packets coming from any number of hosts on a private network to one public IP address.
Task 1: Connect the Power Cable and a Power Source
Connect the power cable to the device and a power source. We recommend using a surge protector. Note the following indications:
POWER LED (green): The device is receiving power.
STATUS LED (green): The device is operating normally.
ALARM LED (amber): The device is operating normally, and may glow amber
because a rescue configuration has not been set. This is not a panic condition.
mPIM LED (off): The Mini-Physical Interface Module (Mini-PIM) is not present or is
not detected by the device. If this LED is green and steadily on, it indicates that the Mini-PIM is functioning normally.
NOTE: After a rescue configuration has been set, an amber ALARM LED indicates a minor alarm, and a solid red ALARM LED indicates a major problem on the services gateway.
NOTE: You must allow the device between 5 and 7 minutes to boot after you power it on. Wait until the STATUS LED is solid green before proceeding to the next task.
Task 2: Connect the Management Device
Connect the management device to the services gateway, using either of the following methods:
Connect an RJ-45 cable (Ethernet cable) from one of the following ports on the front
panel to the Ethernet port on the management device (workstation or laptop):
0/1 (interface ge-0/0/1)
0/2 through 0/7 (interfaces fe-0/0/2 through fe-0/0/7)
We recommend this connection method. If you are using this method to connect, proceed to Task 3.
Connect an RJ-45 cable (Ethernet cable) from the port labeled CONSOLE to the
supplied DB-9 adapter, which then connects to the serial port on the management device (serial port settings: 9600 8-N-1).
If you are using this method to connect, proceed with the CLI configuration instructions in the Branch SRX Series Services Gateways Golden Configurations at http://www.juniper.net/us/en/local/pdf/app-notes/3500153-en.pdf .
An illustration to connect a management interface.
Task 3: Ensure That the Management Device Acquires an IP Address
After you connect the management device to the services gateway, the DHCP server process on the services gateway will assign an IP address automatically to the management device. Ensure that the management device acquires an IP address on the
192.168.1.0/24 subnetwork (other than 192.168.1.1) from the services gateway.
NOTE: The services gateway functions as a DHCP server and will assign an IP address to the management device.
NOTE: If an IP address is not assigned to the management device, manually configure an IP address in the 192.168.1.0/24 subnetwork. Do not assign the 192.168.1.1 IP address to the management device because this IP address is assigned to the services gateway. By default, the DHCP server is enabled on the L3 VLAN interface, (IRB) vlan.0 (ge-0/0/1 and fe-0/0/2 to fe-0/0/7), which is configured with an IP address of
192.168.1.1/24.
NOTE: When an SRX210 Services Gateway is powered on for the first time, it boots using the factory default configuration.
Task 4: Ensure That an IP Address Is Assigned to the Services Gateway
Use one of the following methods to obtain an IP address on the services gateway:
Page 2
Page 3
Method 1: Obtaining a Dynamic IP Address on Your Services Gateway
Use the port labeled 0/0 (interface ge-0/0/0) to connect to your Internet Service Provider (ISP). Your ISP will assign an IP address using the DHCP process. If you use this method, when you get to Task 6, skip Steps 1 through 4.
Method 2: Obtaining a Static IP Address on Your Services Gateway
Use the port labeled 0/0 (interface ge-0/0/0) to connect to your ISP. Your ISP will have provided a static IP address. You will not receive an IP address using the DHCP process. If you use this method, you must configure the static IP address on the services gateway as described in Task 6, Steps 1 through 4.
Task 5: Access the J-Web Interface
1. Launch a Web browser from the management device.
2. Enter http://192.168.1.1 in the browser address box. The J-Web login page appears.
3. Specify the default username as root. Do not enter any value in the Password field.
4. Click Log In. The first time you log in, the J-Web Initial Setup page appears.
5. To begin configuring your services gateway, click the Start button in the lower right corner of the page.
NOTE: All network and management access settings are optional.
If you have followed method 1 of Task 4 (Obtaining a Dynamic IP Address on Your Services Gateway), you can skip all the other steps and go directly to Task 7.
If you have followed method 2 of Task 4 (Obtaining a Static IP Address on Your Services Gateway), ensure that you make the following J-Web modifications:
1. On the Configure System: Network Settings page of the wizard, enter the IP address of the device that connects your device with WAN (service provider) in the Default Gateway field, and enter server names in the DNS Name Servers list. Your ISP provides the IP address for the gateway and the server names.
2. On the Configure Interfaces page of the wizard, select the ge-0/0/0.0 interface and click Edit.
3. On the Add/Edit interface page, next to Address, clear DHCP and select IP Address.
4. In the IP Address/subnet field, enter the IP address provided by your ISP. The IP address must be entered in a.b.c.d/xx format, where xx is the subnet prefix.
Task 6: Configure the Basic Settings
Configure the basic settings, such as hostname, domain name, and root password for your services gateway.
IMPORTANT: Ensure that you have configured the IP address, root authentication, and default gateway before you apply the configuration.
NOTE: All fields marked with an asterisk (*) are mandatory.
NOTE: To allow the required Inbound services and protocols to be terminated on the
Services Gateway, make sure you have selected the required services and protocols under Services (Inbound) and Protocols (Inbound). Select all to permit all protocols and services.
NOTE: You can use the Configure J-Web Preferences page of the wizard to set the J-Web starting page options and J-Web commit options.
Task 7: Apply the Basic Configuration
On the last page (Review and Commit) of the wizard, review the basic configuration, and click Commit to apply the configuration.
After you configure the basic settings, the J-Web Setup wizard redirects you to the J-Web pages, where you can continue configuring the device.
Page 3
Page 4
After you complete initial setup configuration, the Setup wizard is no longer available. To make changes to the configuration, use the J-Web interface.
NOTE: To make any changes to the interface configuration, see the Branch SRX Series Services Gateways Golden Configurations at
http://www.juniper.net/us/en/local/pdf/app-notes/3500153-en.pdf .
Task 8: Verify the Configuration
Access http://www.juniper.net to ensure that you are connected to the Internet. This connectivity ensures that you can pass traffic through the services gateway.
NOTE: If the http://www.juniper.net page does not load, verify your configuration settings, and ensure that you have applied the configuration.
After you complete these steps, you can pass traffic from any trust port to the untrust port.
Powering Off the Device
You can power off the device in one of the following ways:
Graceful shutdown—Press and immediately release the Power button. The device
begins gracefully shutting down the operating system.
Forced shutdown—Press the Power button, and hold it for 10 seconds. The device
immediately shuts down. Press the Power button again to power on the device.
You can reboot or halt the system in the J-Web interface by selecting Maintain >
Reboot.
NOTE: Use the graceful shutdown method to halt, power off, or reboot the services
gateway. Use the forced shutdown method as a last resort to recover the services gateway if the services gateway operating system is not responding to the graceful shutdown method.
For additional configuration information, see the Branch SRX Series Services Gateways Golden Configurations at http://www.juniper.net/us/en/local/pdf/app-notes/3500153-en.pdf .
For detailed software configuration information, see the software documentation available at http://www.juniper.net/techpubs/software/junos-srx/index.html .
NOTE: The Reset Config button is recessed to prevent it from being pressed accidentally.
The rescue configuration is a previously committed, valid configuration. You must have previously set the rescue configuration through the J-Web interface or the CLI.
To press the Reset Config button, insert a small probe (such as a straightened paper clip) into the pinhole on the front panel.
By default, pressing and quickly releasing the Reset Config button loads and
commits the rescue configuration through the J-Web interface or the CLI. The Status LED is amber and steadily on during this time.
By default, pressing and holding the Reset Config button for 15 seconds or
more--until the Status LED is amber and steadily on--deletes all configurations on the device, including the backup configurations and rescue configuration, and loads and commits the factory configuration.
For details about managing and monitoring your device, see the Junos OS Administration Guide and the Junos OS CLI Reference Guide.
Contacting Juniper Networks
For technical support, see http://www.juniper.net/support/requesting-support.html .
Using the Reset Config Button
If a configuration fails or denies management access to the services gateway, you can use the Reset Config button to restore the device to the factory default configuration or to a rescue configuration. For example, if someone inadvertently commits a configuration that denies management access to the services gateway, you can delete the invalid configuration and replace it with a rescue configuration by pressing the Reset Config button.
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice. Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785. Copyright © 2011, Juniper Networks, Inc. All rights reserved. Printed in USA. Part Number: 530-038122 Rev. 01, March 2011.