Juniper E SERIES BROADBAND SERVICES ROUTERS 11.3.X - ERX MODULE GUIDE REV 27-9-2010, ERX User Manual

Page 1
E Series™ Broadband Services Routers
ERX™ Module Guide
Release
11.3.x
Published: 2010-09-27
Copyright © 2010, Juniper Networks, Inc.
Page 2
ERX 11.3.x Module Guide
Unless otherwise specified, all line modules pair with I/O modules to create a module combination. Eachmodule combination provides particularcapabilities and connections in an ERX router.
NOTE: A release may support multiple versions of a module. For information,
see Software Compatibility in JunosE System Basics Configuration Guide, Chapter 6, Managing Modules.
Table 1 on page 3 lists the module combinations supported by ERX routers.
This book also contains three appendixes:
Module Protocol Support on page 87
Module LEDs on page 109
Module Name Cross-Reference Information on page 115
Product Reclamation and Recycling Program on page 119
For more information about ERX routers and modules, refer to the following books:
Modules that have reached end-of-life—E Series End-of-Life Module Guide
Module installation and maintenance—ERX Hardware Guide
Managing ERX routers—JunosE System Basics Configuration Guide
Configuring ERX modules—JunosE Link Layer Configuration Guide
Copyright © 2010, Juniper Networks, Inc.2
Page 3
Table 1: ERX Module Combinations
Fast Ethernet
Gigabit Ethernet (1-port)
Line Module LabelCombination Name and Type
GE/FEFE-8 SFP (8 ports) (256-MB memory)
GE/FEGE multimode
GE/FEGE single-mode
I/O Module Label
I/O
MULTI MODE
SINGLE MODE
First JunosE Support
Page
85.0.0FE-8 I/OGE/FEFE-8 (8 ports) (256-MB memory)
96.0.0FE-8 SFP
115.0.0GE I/O SFPGE/FEGE 1000Base-SX (256-MB memory)
135.0.0GE I/O SFPGE/FEGE 1000Base-LH (256-MB memory)
155.0.0GE I/O SFPGE/FEGE 1000Base-ZX (256-MB memory)
172.0.0GE I/O
192.0.0GE I/O
Gigabit Ethernet (2-port)
GE-2GE2 1000Base-SX
I/O or
2XGE APS I/O SFP or
GE-2 APS I/O SFP
GE-2GE2 1000Base-LH
I/O or
2XGE APS I/O SFP or
GE-2 APS I/O SFP
GE-2GE2 1000Base-ZX
I/O or
2XGE APS I/O SFP or
GE-2 APS I/O SFP
215.3.0GE-2 SFP
235.3.0GE-2 SFP
255.3.0GE-2 SFP
3Copyright © 2010, Juniper Networks, Inc.
Page 4
ERX 11.3.x Module Guide
Table 1: ERX Module Combinations (continued)
GE High Density (HDE)
OC3/STM1 ATM
OC3/STM1 ATM multimode without APS/MSPredundancy (256-MB memory)
OC3/STM1ATM multimode with APS/MSP redundancy
Line Module LabelCombination Name and Type
GE-HDEGE High Density (2 ports)
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
I/O Module Label
I/O or
2XGE APS I/O SFP or
GE-2 APS I/O SFP
MULTI MODE
4XOC3 APS I/O
MULTI MODE
First JunosE Support
5.2.0 (APS/MSP)
Page
277.0.0GE-2 SFP
297.0.0GE-8 I/OGE-HDEGE High Density (8 ports)
315.0.0, 5.3.0OC3-4 I/O
335.1.2
OC3/STM1ATM single-mode intermediate reach without APS/MSP redundancy (256-MB memory)
OC3/STM1ATM single-mode intermediate reach with APS/MSP redundancy
OC3/STM1 ATM single-mode long reach without APS/MSP redundancy (256-MB memory)
OC3/STM1 GE/FE
OC3/STM1 GE/FE
OC3/STM1 POS
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC3/STM1 GE/FE
SINGLE MODE
4XOC3
APS I/O
SINGLE MODE
LONG HAUL
APS I/O
355.0.0, 5.3.0OC3-4 I/O
375.1.2
5.2.0 (APS/MSP)
395.0.0, 5.3.0OC3-4 I/O
416.1.0OC3–2 GE
Copyright © 2010, Juniper Networks, Inc.4
Page 5
Table 1: ERX Module Combinations (continued)
OC3/STM1 POS multimode without APS/MSP redundancy
OC3/STM1POS multimode with APS/MSP redundancy
OC3/STM1POS single-mode intermediate reach without APS/MSP redundancy
OC3/STM1POS single-mode intermediate reach with APS/MSP redundancy
OC3/STM1 POS single-mode long reach
Line Module LabelCombination Name and Type
OCx/STMx POS
OCx/STMx POS
OCx/STMx POS
OCx/STMx POS
OCx/STMx POS
I/O Module Label
MULTI MODE
4XOC3 APS I/O
MULTI MODE
SINGLE MODE
4XOC3 APS I/O
SINGLE MODE
LONG HAUL
First JunosE Support
5.2.0 (APS/MSP)
5.2.0 (APS/MSP)
Page
452.0.0OC3-4 I/O
475.1.2
492.0.0OC3-4 I/O
515.1.2
532.0.0OC3-4 I/O
OC12/STM4 ATM
OC12/STM4 ATM multimode without APS/MSPredundancy (256-MB memory)
OC12/STM4 ATM multimode with APS/MSP redundancy
OC12/STM4 ATM single-mode intermediate reach without APS/MSP redundancy (256-MB memory)
OC12/STM4 ATM single-mode intermediate reach with APS/MSP redundancy
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
I/O
MULTI MODE
OC12 STM4 APS
MULTI MODE
I/O
SINGLE MODE
OC12 STM4 APS
SINGLE MODE
555.0.0, 5.3.0OC12 STM4
572.0.0 (128
MB)
5.0.0 (256 MB)
595.0.0, 5.3.0OC12 STM4
612.0.0 (128
MB)
5.0.0 (256 MB)
5Copyright © 2010, Juniper Networks, Inc.
Page 6
ERX 11.3.x Module Guide
Table 1: ERX Module Combinations (continued)
OC12/STM4 ATM single-mode long reach without APS/MSP redundancy (256-MB memory)
OC12/STM4 ATM single-mode long reach with APS/MSP redundancy
OC12/STM4 POS
OC12/STM4 POS multimode without APS/MSP redundancy
OC12/STM4 POS multimode with APS/MSP redundancy
Line Module LabelCombination Name and Type
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx POS
OCx/STMx POS
I/O Module Label
I/O
LONG HAUL
OC12 STM4 APS
LONG HAUL
I/O
MULTI MODE
APS
MULTI MODE
First JunosE Support
MB)
5.0.0 (256 MB)
Page
635.0.0, 5.3.0OC12 STM4
652.0.0 (128
672.0.0OC12 STM4
692.0.0OC12 STM4
OC12/STM4 POS single-mode intermediate reach without APS/MSP redundancy
OC12/STM4 POS single-mode intermediate reach with APS/MSP redundancy
OC12/STM4 POS single-mode long reach without APS/MSP redundancy
OC12/STM4 POS single-mode long reach with APS/MSP redundancy
OC48/STM16
reach
OCx/STMx POS
OCx/STMx POS
OCx/STMx POS
OCx/STMx POS
OC48OC48/STM16 POS single-mode short
712.0.0OC12 STM4
I/O
SINGLE MODE
732.0.0OC12 STM4
APS
SINGLE MODE
752.0.0OC12 STM4
I/O
LONG HAUL
772.0.0OC12 STM4
APS
LONG HAUL
794.1.xOC48
FRAME APS
Copyright © 2010, Juniper Networks, Inc.6
Page 7
Table 1: ERX Module Combinations (continued)
Service Module (SM)
SM
SRPs
SRP-40G PLUS (2-GB memory)
T3
T3 ATM (4 ports)
Line Module LabelCombination Name and Type
SERVICE MODULE
PLUS
OCx/STMx ATM or OCx/STMx /DS3-ATM
I/O Module Label
module
SRP I/OSRP-5G+SRP-5G+ (1-GB memory)
SRP I/OSRP-10GSRP-10G (2-GB memory)
4xDS3 ATM I/O
First JunosE Support
5.1.2, 5.2.0
5.1.2, 5.2.0
104 MB)
5.0.0 (256 MB)
Page
805.1.0No I/O
814.1.3, 5.0.4,
824.1.3, 5.0.4,
834.0.0SRP I/OSRP-40G
845.3.0SRP-SE I/OSRP-SE10GSRP-SE10G (1-GB memory)
854.1.0 (128
7Copyright © 2010, Juniper Networks, Inc.
Page 8
ERX 11.3.x Module Guide
FE-8 Module Combination (8 Ports) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
FE-8 I/O
8
First supported: 5.0.0
Final supported: Not applicable
The GE/FE line module must have a minimum of 256 MB of memory to be used with JunosE Release 5.3.0 or a higher-numbered release.
130 W
Fast Ethernet
EFA ASIC
IEEE 802.3 standards compliance
10/100Base-T
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
RJ-45 connectors
For 10-Mbps operation, use CAT 3, 4, or 5 UTP cable.
For 100-Mbps operation, use only CAT 5 UTP cable.
The transmitted signal complies with IEEE 802.3/802.3u for cable lengths up to 100 m (328 feet).
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Copyright © 2010, Juniper Networks, Inc.8
Page 9
FE-8 SFP Module Combination (8 Ports) (256-MB Memory)
FE-8 SFP Module Combination (8 Ports) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
FE-8 SFP I/O
8
First supported: 6.0.0
Final supported: Not applicable
130 W
Fast Ethernet
The FE-8 SFP I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cable lengths.
EFA ASIC
IEEE 802.3 standards compliance
100Base-FX
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors (single-mode fiber)
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
LC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1300 nm
Rx input power:
min: –28 dBm
max: –14 dBm
Rated for 10 km (6.2 miles) over 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
9Copyright © 2010, Juniper Networks, Inc.
Page 10
ERX 11.3.x Module Guide
Cables and connectors (multimode fiber)
LEDs
Alarms, errors, and events
LC full duplex
Tx power: –20 dBm minimum and –14 dBm maximum
Center wavelength: 850 nm
Rx input power: –31 dBm minimum and –14 dBm maximum
Rated for 2 km (1.2 miles) over 62.5/125-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Copyright © 2010, Juniper Networks, Inc.10
Page 11
GE 1000Base-SX Module Combination (1 Port) (256-MB Memory)
GE 1000Base-SX Module Combination (1 Port) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
GE/FE
GE I/O SFP
1 active, 1 redundant
First supported: 5.0.0
Final supported: Not applicable
130 W
Gigabit Ethernet
256 MB of memory
The 128-MB version has reached end-of-life.
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Uses either optical or copper SFPs.
The optical transceivers are 1000Base-SX compliant.
The copper transceivers are 1000Base-T compliant.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following corresponding table (Single-strand SFPs Pairing) for more information.
EFA ASIC
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
Cables and connectors (copper SFP)
Ethernet (IEEE 802.3z)
1000Base-SX
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
Maximum range is 100 meters on CAT5 cable.
11Copyright © 2010, Juniper Networks, Inc.
Page 12
ERX 11.3.x Module Guide
Cables and connectors (SX)
LEDs
Alarms, errors, and events
LC full duplex
Tx power:
min: –9.5 dBm
max: –4 dBm
Center wavelength: 850 nm
Rx input power:
min: –20 dBm
max: –0 dBm
Rated for 275 m (300 yards) over 62.5-micron core cable
Rated for 550 m (601 yards) over 50-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Table 2: Single-strand SFPs Pairing
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.12
Page 13
GE 1000Base-LH Module Combination (1 Port) (256-MB Memory)
GE 1000Base-LH Module Combination (1 Port) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
GE/FE
GE I/O SFP
1 active, 1 redundant
First supported: 5.0.0
Final supported: Not applicable
130 W
Gigabit Ethernet
256 MB of memory
The 128-MB version has reached end-of-life.
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Uses either optical or copper SFPs.
The optical transceivers are 1000Base-LX/LH compliant.
The copper transceivers are 1000Base-T compliant.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following corresponding table (Single-strand SFPs Pairing) for more information.
EFA ASIC
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
Cables and connectors (copper SFP)
Ethernet (IEEE 802.3z)
1000Base-LH
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
Maximum range is 100 meters on CAT5 cable.
13Copyright © 2010, Juniper Networks, Inc.
Page 14
ERX 11.3.x Module Guide
Cables and connectors (LX/LH)
LEDs
Alarms, errors, and events
Table 3: Single-strand SFPs Pairing
LC full duplex
Tx power:
min: –9.5 dBm
max: –3 dBm
Center wavelength: 1300 nm
Rx input power:
min: –20 dBm
max: –3 dBm
Rated for 10 km (6.2 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.14
Page 15
GE 1000Base-ZX Module Combination (1 Port) (256-MB Memory)
GE 1000Base-ZX Module Combination (1 Port) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
GE/FE
GE I/O SFP
1 active, 1 redundant
First supported: 5.0.0
Final supported: Not applicable
130 W
Gigabit Ethernet
256 MB of memory
The 128-MB version has reached end-of-life.
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Uses either optical or copper SFPs.
The optical transceivers are 1000Base-ZX compliant.
The copper transceivers are 1000Base-T compliant.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following corresponding table (Single-strand SFPs Pairing) for more information.
EFA ASIC
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
Cables and connectors (copper SFP)
Ethernet (IEEE 802.3z)
1000Base-ZX
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
Maximum range is 100 meters on CAT5 cable.
15Copyright © 2010, Juniper Networks, Inc.
Page 16
ERX 11.3.x Module Guide
Cables and connectors (ZX)
LEDs
Alarms, errors, and events
LC full duplex
Tx power:
min: –2 dBm
max: 3 dBm
Center wavelength: 1550 nm
Rx input power:
min: –22 dBm
max: –3 dBm
Rated for 70 km (43.4 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Table 4: Single-strand SFPs Pairing
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.16
Page 17
GE Multimode Module Combination (1 Port)
GE Multimode Module Combination (1 Port)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
GE I/O
MULTI MODE
1 active, 1 redundant
First supported: 2.0.0
Final supported: Not applicable
130 W
Gigabit Ethernet
This module combination has been superseded by a newer assembly; however, it is supported by current software.
EFA ASIC
Ethernet (IEEE 802.3z)
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
SC full duplex
Tx power:
min: –9.5 dBm
max: –4 dBm
Center wavelength: 850 nm
Rx input power:
min: –17 dBm
max: –3 dBm
Rated for 275 m (300 yards) over 62.5-micron core cable
Rated for 550 m (601 yards) over 50-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
17Copyright © 2010, Juniper Networks, Inc.
Page 18
ERX 11.3.x Module Guide
Alarms, errors, and events
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Copyright © 2010, Juniper Networks, Inc.18
Page 19
GE Single-Mode Module Combination (1 Port)
GE Single-Mode Module Combination (1 Port)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
GE I/O
SINGLE MODE
1 active, 1 redundant
First supported: 2.0.0
Final supported: Not applicable
130 W
Gigabit Ethernet
This module combination has been superseded by a newer assembly; however, it is supported by current software.
EFA ASIC
Ethernet (IEEE 802.3z)
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
SC full duplex
Tx power:
min: –11 dBm
max: –3 dBm
Center wavelength: 1300 nm
Rx input power:
min: –20 dBm
max: –3 dBm
Rated for 550 m (601 yards) over 62.5-micron core or 50-micron core MM fiber
Rated for 5 km (3.1 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
19Copyright © 2010, Juniper Networks, Inc.
Page 20
ERX 11.3.x Module Guide
Alarms, errors, and events
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Copyright © 2010, Juniper Networks, Inc.20
Page 21
GE2 1000Base-SX Module Combination (2 Ports)
GE2 1000Base-SX Module Combination (2 Ports)
Line module label
I/O module label
Number of I/O ports
Software release
Description
GE-2
GE-2 SFP I/O or 2XGE APS I/O SFP or GE-2 APS I/O SFP
2 active, 2 redundant
First supported: 5.3.0
Final supported: Not applicable
100 W
Gigabit Ethernet
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Uses either optical or copper SFPs.
The optical transceivers are 1000Base-SX compliant.
The copper transceivers are 1000Base-T compliant.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following corresponding table (Single-strand SFPs Pairing) for more information.
For information about bandwidth and line rate considerations for the GE2 1000Base-SX module combination, see GE–2 SFP I/O Module in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Type
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
Cables and connectors (copper SFP)
FFA ASIC
Ethernet (IEEE 802.3z)
1000Base-SX
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX1440 router
ERX310 router
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
Maximum range is 100 meters on CAT5 cable.
21Copyright © 2010, Juniper Networks, Inc.
Page 22
ERX 11.3.x Module Guide
Cables and connectors (SX)
LEDs
Alarms, errors, and events
LC full duplex
Tx power:
min: –9.5 dBm
max: –4 dBm
Center wavelength: 850 nm
Rx input power:
min: –17 dBm
max: –3 dBm
Rated for 275 m (300 yards) over 62.5-micron core cable
Rated for 550 m (601 yards) over 50-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Table 5: Single-strand SFPs Pairing
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.22
Page 23
GE2 1000Base-LH Module Combination (2 Ports)
GE2 1000Base-LH Module Combination (2 Ports)
Line module label
I/O module label
Number of I/O ports
Software release
Description
GE-2
GE-2 SFP I/O or 2XGE APS I/O SFP or GE-2 APS I/O SFP
2 active, 2 redundant
First supported: 5.3.0
Final supported: Not applicable
100 W
Gigabit Ethernet
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Uses either optical or copper SFPs.
The optical transceivers are 1000Base-LX/LH compliant.
The copper transceivers are 1000Base-T compliant.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following corresponding table (Single-strand SFPs Pairing) for more information.
For information about bandwidth and line rate considerations for the GE2 1000Base-LH module combination, see GE–2 SFP I/O Module in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Type
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
Cables and connectors (copper SFP)
FFA ASIC
Ethernet (IEEE 802.3z)
1000Base-LH
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX1440 router
ERX310 router
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
Maximum range is 100 meters on CAT5 cable.
23Copyright © 2010, Juniper Networks, Inc.
Page 24
ERX 11.3.x Module Guide
Cables and connectors (LX/LH)
Cables and connectors (single–mode LX40)
LC full duplex
Tx power:
min: –9.5 dBm
max: –3 dBm
Center wavelength: 1300 nm
Rx input power:
min: –20 dBm
max: –3 dBm
Rated for 10 km (6.2 miles) over 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LC full duplex
Tx power:
min: –4.5 dBm
max: 0 dBm
Center wavelength: 1300 nm
Rx input power:
min: –35 dBm
max: –22.5 dBm
Rated for 40 km (24.85 miles) over 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Table 6: Single-strand SFPs Pairing
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.24
Page 25
GE2 1000Base-ZX Module Combination (2 Ports)
GE2 1000Base-ZX Module Combination (2 Ports)
Line module label
I/O module label
Number of I/O ports
Software release
Description
GE-2
GE-2 SFP I/O or 2XGE APS I/O SFP or GE-2 APS I/O SFP
2 active, 2 redundant
First supported: 5.3.0
Final supported: Not applicable
100 W
Gigabit Ethernet
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Uses either optical or copper SFPs.
The optical transceivers are 1000Base-ZX compliant.
The copper transceivers are 1000Base-T compliant.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following corresponding table (Single-strand SFPs Pairing) for more information.
For information about bandwidth and line rateconsiderationsfor the GE2 1000Base-ZX module combination, see GE-2 SFP I/O Module in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Type
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
FFA ASIC
Ethernet (IEEE 802.3z)
1000Base-ZX
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX1440 router
ERX310 router
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
25Copyright © 2010, Juniper Networks, Inc.
Page 26
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
LC full duplex
Tx power:
min: –3 dBm
max: 2 dBm
Center wavelength: 1550 nm
Rx input power:
min: –23 dBm
max: –3 dBm
Rated for 70 km (43.4 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Table 7: Single-strand SFPs Pairing
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.26
Page 27
GE High Density (HDE) Module Combination (2 Ports)
GE High Density (HDE) Module Combination (2 Ports)
Line module label
I/O module label
Number of I/O ports
Software release
Description
GE-HDE
GE-2 SFP I/O or 2XGE APS I/O SFP or GE-2 APS I/O SFP
2 active, 2 redundant
First supported: 7.0.0
Final supported: Not applicable
100 W
Gigabit Ethernet
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Uses either optical or copper SFPs.
The optical transceivers are 1000Base-LX/LH compliant.
The copper transceivers are 1000Base-T compliant.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following corresponding table (Single-strand SFPs Pairing) for more information.
For information about bandwidth and line rate considerationsfor the GE–HDE module combination, see GE-2 SFP I/O Module in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Type
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
Cables and connectors (copper SFP)
FFA ASIC
Ethernet (IEEE 802.3z)
1000Base-LH
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX1440 router
ERX310 router
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
Maximum range is 100 meters on CAT5 cable.
27Copyright © 2010, Juniper Networks, Inc.
Page 28
ERX 11.3.x Module Guide
Cables and connectors (LX/LH)
Cables and connectors (single-mode LX40)
LC full duplex
Tx power:
min: –9.5 dBm
max: –3 dBm
Center wavelength: 1300 nm
Rx input power:
min: –20 dBm
max: –3 dBm
Rated for 10 km (6.2 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LC full duplex
Tx power:
min: –4.5 dBm
max: 0 dBm
Center wavelength: 1300 nm
Rx input power:
min: –35 dBm
max: –22.5 dBm
Rated for 40 km (24.85 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Table 8: Single-strand SFPs Pairing
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.28
Page 29
GE High Density (HDE) Module Combination (8 Ports)
GE High Density (HDE) Module Combination (8 Ports)
Line module label
I/O module label
Number of I/O ports
Software release
Description
GE-HDE
GE-8 I/O
8
First supported: 7.0.0
Final supported: Not applicable
100 W
Gigabit Ethernet
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Uses either optical or copper SFPs.
The optical transceivers are 1000Base-LX/LH compliant.
The copper transceivers are 1000Base-T compliant.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following corresponding table (Single-strand SFPs Pairing) for more information.
For information about bandwidth and line rateconsiderations for the GE–HDE module combination, see GE-8 I/O Module in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Type
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
FFA ASIC
Ethernet (IEEE 802.3z)
1000Base-LH
See “Ethernet Modules” on page 87 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX1440 router
ERX310 router
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
29Copyright © 2010, Juniper Networks, Inc.
Page 30
ERX 11.3.x Module Guide
Cables and connectors
Cables and connectors (single-mode LX40)
LC full duplex
Tx power:
min: –9.5 dBm
max: –3 dBm
Center wavelength: 1300 nm
Rx input power:
min: –20 dBm
max: –3 dBm
Rated for 10 km (6.2 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LC full duplex
Tx power:
min: –4.5 dBm
max: 0 dBm
Center wavelength: 1300 nm
Rx input power:
min: –35 dBm
max: –22.5 dBm
Rated for 40 km (24.85 miles) over 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5, Configuring Ethernet Interfaces.
Table 9: Single-strand SFPs Pairing
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.30
Page 31
OC3/STM1 ATM Multimode Without APS/MSP Redundancy Module Combination (256-MB Memory)
OC3/STM1 ATM Multimode Without APS/MSP Redundancy Module Combination (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC3-4 I/O
MULTI MODE
4
First supported: 5.0.0, 5.3.0 or a higher-numbered release
Final supported: Not applicable
130 W
256 MB of memory
The 128-MB version has reached end-of-life.
Unchannelized, concatenated OC3/STM1 for ATM
EFA ASIC
OC3/STM1
ATM:AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
31Copyright © 2010, Juniper Networks, Inc.
Page 32
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.32
Page 33
OC3/STM1 ATM Multimode With APS/MSP Redundancy Module Combination
OC3/STM1 ATM Multimode With APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
OCx/STMx ATM or OCx/STMx /DS3-ATM
4XOC3
APS I/O
MULTI MODE
4 active, 4 redundant
First supported: 5.1.2, 5.2.0 (APS/MSP)
Final supported: Not applicable
The OCx/STMx ATM line module or the OCx/STMx /DS3-ATM line module must have a minimum of 256 MB of memory to be used with JunosE Release 5.3.0 or a higher-numbered release.
130 W
Can use either the 128-MB OCx/STMx ATM line module or the 256-MB OCx/STMx /DS3-ATM line module.
Unchannelized, concatenated OC3/STM1 for ATM
EFA ASIC
OC3/STM-1
ATM/AAL5
Software features
Model compatibility
SRP module compatibility
Module redundancy support
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
33Copyright © 2010, Juniper Networks, Inc.
Page 34
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
LC full duplex
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.34
Page 35
OC3/STM1 ATM Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination (256-MB Memory)
OC3/STM1 ATM Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC3-4 I/O
SINGLE MODE
4
First supported: 5.0.0, 5.3.0 or a higher-numbered release
Final supported: Not applicable
130 W
256 MB of memory
The 128-MB version has reached end-of-life.
Unchannelized, concatenated OC3/STM1 for ATM
EFA ASIC
OC3/STM1
ATM/AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
35Copyright © 2010, Juniper Networks, Inc.
Page 36
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.36
Page 37
OC3/STM1 ATM Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination
OC3/STM1ATM Single-Mode IntermediateReachWith APS/MSPRedundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
OCx/STMx ATM or OCx/STMx /DS3-ATM
4XOC3
APS I/O
SINGLE MODE
4 active, 4 redundant
First supported: 5.1.2, 5.2.0 (APS/MSP)
Final supported: Not applicable
The OCx/STMx ATM line module or the OCx/STMx /DS3-ATM line module must have a minimum of 256 MB of memory to be used with JunosE Release 5.3.0 or a higher-numbered release.
130 W
Can use either the 128-MB OCx/STMx ATM line module or the 256-MB OCx/STMx /DS3-ATM line module.
Unchannelized, concatenated OC3/STM1 for ATM
EFA ASIC
OC3/STM-1
ATM/AAL5
Software features
Model compatibility
SRP module compatibility
Module redundancy support
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
37Copyright © 2010, Juniper Networks, Inc.
Page 38
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
LC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.38
Page 39
OC3/STM1 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (256-MB Memory)
OC3/STM1 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC3-4 I/O
LONG HAUL
4
First supported: 5.0.0, 5.3.0 or a higher-numbered release
Final supported: Not applicable
130 W
256 MB of memory
The 128-MB version has reached end-of-life.
Unchannelized, concatenated OC3/STM1 for ATM
EFA ASIC
OC3/STM1
ATM/AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
39Copyright © 2010, Juniper Networks, Inc.
Page 40
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.40
Page 41
OC3/STM1 GE/FE Module Combination
OC3/STM1 GE/FE Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
OC3/STM1 GE/FE
OC3-2 GE APS I/O
3; one active and one redundant port per SFP
Ports 0 and 1—ATM interfaces
Port 2—GE interface
Port redundancy is not supported.
First supported: 6.1.0
Final supported: Not applicable
150 W
Unchannelized OC3/STM1 ATM operation via two line interfaces
and
Gigabit Ethernet operation via one line interface
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Depending on the configuration, a variety of SFP combinations can occur.
The OC3-2 GE APS I/O module accepts up to three LC-style fiber-optic or copper SFPs.
Single-strand SFPs can be used. These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same maximum operating range. See the following table (Single-strand SFPs Pairing) for more information.
Type
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
EFA ASIC
OC3/STM1
ATM/AAL5
Ethernet (IEEE 802.3x)
1000Base-LX/SX/ZX
See “OCx/STMx GE/FE Modules” on page 94 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Not applicable
41Copyright © 2010, Juniper Networks, Inc.
Page 42
ERX 11.3.x Module Guide
Cables and connectors (ATM LX)
Cables and connectors (ATM SX)
LC-style fiber-optic connectors
Tx power:
min: –19.0 dBm
max: –14dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9db or over 50-micron core cable with an optical loss of 7 db
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LC-style fiber-optic connectors
Tx power:
min: –15.0 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Cables and connectors (ATM ZX)
Cables and connectors (GE LX)
LC-style fiber-optic connectors
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LC full duplex
Tx power:
min: –9.5 dBm
max: –3 dBm
Center wavelength: 1300 nm
Rx input power:
min: –20 dBm
max: –3 dBm
Rated for 10 km (6.2 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Copyright © 2010, Juniper Networks, Inc.42
Page 43
Cables and connectors (GE single–mode LX40)
Cables and connectors (GE SX)
OC3/STM1 GE/FE Module Combination
LC full duplex
Tx power:
min: –4.5 dBm
max: –0 dBm
Center wavelength: 1300 nm
Rx input power:
min: –35 dBm
max: –22.5 dBm
Rated for 40 km (28.85 miles) over 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
LC full duplex
Tx power:
min: –9.5 dBm
max: –4 dBm
Center wavelength: 850 nm
Rx input power:
min: –17 dBm
max: –3 dBm
Rated for 275 m (300 yards) over 62.5-micron core cable
Rated for 550 m (601 yards) over 50-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Cables and connectors (GE ZX)
LEDs
Alarms, errors, and events
LC full duplex
Tx power:
min: –3 dBm
max: 2 dBm
Center wavelength: 1550 nm
Rx input power:
min: –23 dBm
max: –3 dBm
Rated for 70 km (43.4 miles) over 10-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Table 10: Single-strand SFPs Pairing
9 microns
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
10 (6.2 miles), matching SFP must have the same operating range
43Copyright © 2010, Juniper Networks, Inc.
Page 44
ERX 11.3.x Module Guide
Table 10: Single-strand SFPs Pairing (continued)
Maximum Operating Range (kilometers)Nominal Wavelength (nm)Fiber Type
9 microns
TX 1550 / RX 1310
Pairs with TX 1310, RX 1550
10 (6.2 miles), matching SFP must have the same operating range
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1490
Pairs with TX 1490 / RX 1310
TX 1490 / RX 1310
Pairs with TX 1310, RX 1490
TX 1310, RX 1550
Pairs with TX 1550 / RX 1310
TX 1550, RX 1310
Pairs with TX 1310 / RX 1550
10 (6.2 miles), matching SFP must have the same operating range
10 (6.2 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
40 (24.85 miles), matching SFP must have the same operating range
Copyright © 2010, Juniper Networks, Inc.44
Page 45
OC3/STM1 POS Multimode Without APS/MSP Redundancy Module Combination
OC3/STM1 POS Multimode Without APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC3-4 I/O
MULTI MODE
4
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC3/STM1 for POS
EFA ASIC
OC3/STM1
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
45Copyright © 2010, Juniper Networks, Inc.
Page 46
ERX 11.3.x Module Guide
Alarms, errors, and events
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.46
Page 47
OC3/STM1 POS Multimode With APS/MSP Redundancy Module Combination
OC3/STM1 POS Multimode With APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
4XOC3
APS I/O
MULTI MODE
4 active, 4 redundant
First supported: 5.1.2, 5.2.0 (APS/MSP)
Final supported: Not applicable
120 W
Unchannelized, concatenated OC3/STM1 for POS
EFA ASIC
OC3/STM-1
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
LC full duplex
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
47Copyright © 2010, Juniper Networks, Inc.
Page 48
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.48
Page 49
OC3/STM1 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination
OC3/STM1 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC3-4 I/O
SINGLE MODE
4
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC3/STM1 for POS
EFA ASIC
OC3/STM1
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
49Copyright © 2010, Juniper Networks, Inc.
Page 50
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.50
Page 51
OC3/STM1 POS Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination
OC3/STM1POS Single-ModeIntermediateReach WithAPS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
4XOC3
APS I/O
SINGLE MODE
4 active, 4 redundant
First supported: 5.1.2, 5.2.0 (APS/MSP)
Final supported: Not applicable
120 W
Unchannelized, concatenated OC3/STM1 for POS
EFA ASIC
OC3/STM1
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
LC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
51Copyright © 2010, Juniper Networks, Inc.
Page 52
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.52
Page 53
OC3/STM1 POS Single-Mode Long Reach Module Combination
OC3/STM1 POS Single-Mode Long Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC3-4 I/O
LONG HAUL
4
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC3/STM1 for POS
EFA ASIC
OC3/STM1
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Fiber type: 9-micron core
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
53Copyright © 2010, Juniper Networks, Inc.
Page 54
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.54
Page 55
OC12/STM4 ATM Multimode Without APS/MSP Redundancy Module Combination (256-MB Memory)
OC12/STM4 ATM Multimode Without APS/MSP Redundancy Module Combination (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 I/O
MULTI MODE
1
First supported: 5.0.0, 5.3.0 or a higher-numbered release
Final supported: Not applicable
130 W
256 MB of memory
The 128-MB version has reached end-of-life.
Unchannelized, concatenated OC12/STM4 for ATM
EFA ASIC
OC12/STM4
ATM/AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
55Copyright © 2010, Juniper Networks, Inc.
Page 56
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.56
Page 57
OC12/STM4 ATM Multimode With APS/MSP Redundancy Module Combination
OC12/STM4 ATM Multimode With APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 APS
MULTI MODE
1 active, 1 redundant
First supported: 2.0.0 (128 MB), 5.0.0 (256 MB)
Final supported: Not applicable
The OCx/STMx ATM line module or the OCx/STMx /DS3-ATM line module must have a minimum of 256 MB of memory to be used with JunosE Release 5.3.0 or a higher-numbered release.
130 W
Can use either the 128-MB OCx/STMx ATM line module or the 256-MB OCx/STMx /DS3-ATM line module.
Unchannelized, concatenated OC12/STM4 for ATM
EFA ASIC
OC12/STM4
ATM/AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
57Copyright © 2010, Juniper Networks, Inc.
Page 58
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.58
Page 59
OC12/STM4 ATM Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination (256-MB Memory)
OC12/STM4 ATM Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 I/O
SINGLE MODE
1
First supported: 5.0.0, 5.3.0 or a higher-numbered release
Final supported: Not applicable
130 W
256 MB of memory
The 128-MB version has reached end-of-life.
Unchannelized, concatenated OC12/STM4 for ATM
EFA ASIC
OC12/STM4
ATM/AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
59Copyright © 2010, Juniper Networks, Inc.
Page 60
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.60
Page 61
OC12/STM4 ATM Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination
OC12/STM4ATM Single-Mode IntermediateReach With APS/MSP RedundancyModule Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 APS
SINGLE MODE
1 active, 1 redundant
First supported: 2.0.0 (128 MB), 5.0.0 (256 MB)
Final supported: Not applicable
The OCx/STMx ATM line module or the OCx/STMx/DS3-ATM line module must have a minimum of 256 MB of memory to be used with JunosE Release 5.3.0 or a higher-numbered release.
130 W
Can use either the 128-MB OCx/STMx ATM line module or the 256-MB OCx/STMx/DS3-ATM line module.
Unchannelized, concatenated OC12/STM4 for ATM
EFA ASIC
OC12/STM4
ATM/AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
61Copyright © 2010, Juniper Networks, Inc.
Page 62
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.62
Page 63
OC12/STM4 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (256-MB Memory)
OC12/STM4 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 I/O
LONG HAUL
1
First supported: 5.0.0, 5.3.0 or a higher-numbered release
Final supported: Not applicable
130 W
256 MB of memory
The 128-MB version has reached end-of-life.
Unchannelized, concatenated OC12/STM4 for ATM
EFA ASIC
OC12/STM4
ATM/AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
63Copyright © 2010, Juniper Networks, Inc.
Page 64
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Fiber type: 9-micron core
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.64
Page 65
OC12/STM4 ATM Single-Mode Long Reach With APS/MSP Redundancy Module Combination
OC12/STM4 ATM Single-Mode Long Reach With APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 APS
LONG HAUL
1 active, 1 redundant
First supported: 2.0.0 (128 MB), 5.0.0 (256 MB)
Final supported: Not applicable
The OCx/STMx ATM line module or the OCx/STMx /DS3-ATM line module must have a minimum of 256 MB of memory to be used with JunosE Release 5.3.0 or a higher-numbered release.
130 W
Can use either the 128-MB OCx/STMx ATM line module or the 256-MB OCx/STMx /DS3-ATM line module.
Unchannelized, concatenated OC12/STM4 for ATM
EFA ASIC
OC12/STM4
ATM/AAL5
See “OCx/STMx ATM Modules” on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
65Copyright © 2010, Juniper Networks, Inc.
Page 66
ERX 11.3.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Fiber type: 9-micron core
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.66
Page 67
OC12/STM4 POS Multimode Without APS/MSP Redundancy Module Combination
OC12/STM4 POS Multimode Without APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC12 STM4 I/O
MULTI MODE
1
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC12/STM4 for POS
EFA ASIC
OC12/STM4
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
67Copyright © 2010, Juniper Networks, Inc.
Page 68
ERX 11.3.x Module Guide
Alarms, errors, and events
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.68
Page 69
OC12/STM4 POS Multimode With APS/MSP Redundancy Module Combination
OC12/STM4 POS Multimode With APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC12 STM4 APS
MULTI MODE
1 active, 1 redundant
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC12/STM4 for POS
EFA ASIC
OC12/STM4
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Ratedfor 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
69Copyright © 2010, Juniper Networks, Inc.
Page 70
ERX 11.3.x Module Guide
Alarms, errors, and events
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.70
Page 71
OC12/STM4 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination
OC12/STM4 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC12 STM4 I/O
SINGLE MODE
1
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC12/STM4 for POS
EFA ASIC
OC12/STM4
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
71Copyright © 2010, Juniper Networks, Inc.
Page 72
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.72
Page 73
OC12/STM4 POS Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination
OC12/STM4POS Single-Mode Intermediate ReachWith APS/MSP RedundancyModule Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC12 STM4 APS
SINGLE MODE
1 active, 1 redundant
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC12/STM4 for POS
EFA ASIC
OC12/STM4
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
73Copyright © 2010, Juniper Networks, Inc.
Page 74
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.74
Page 75
OC12/STM4 POS Single-Mode Long Reach Without APS/MSP Redundancy Module Combination
OC12/STM4 POS Single-Mode Long Reach Without APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC12 STM4 I/O
LONG HAUL
1
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC12/STM4 for POS
EFA ASIC
OC12/STM4
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
75Copyright © 2010, Juniper Networks, Inc.
Page 76
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.76
Page 77
OC12/STM4 POS Single-Mode Long Reach With APS/MSP Redundancy Module Combination
OC12/STM4 POS Single-Mode Long Reach With APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx POS
OC12 STM4 APS
LONG HAUL
1 active, 1 redundant
First supported: 2.0.0
Final supported: Not applicable
120 W
Unchannelized, concatenated OC12/STM4 for POS
EFA ASIC
OC12/STM4
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
SC full duplex
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
77Copyright © 2010, Juniper Networks, Inc.
Page 78
ERX 11.3.x Module Guide
LEDs
Alarms, errors, and events
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.78
Page 79
OC48/STM16 POS Single-Mode Short Reach Module Combination
OC48/STM16 POS Single-Mode Short Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SRP module compatibility
OC48
OC48 FRAME APS
1
First supported: 4.1.x
Final supported: Not applicable
120 W
Unchannelized, concatenated OC48/STM16 for POS
FFA ASIC
OC48/STM16
HDLC framing
See “OCx/STMx POS and OC48 Modules” on page 99 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX1440 router
SRP-40G
SRP-40G PLUS
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
Not applicable
LC full duplex connector
Transmit power:
min: –10 dBm
max: –3 dBm
Center wavelength: 1310 nm
Receive input power:
min: –18 dBm
max: –3 dBm
Rated for 2 km (1.2 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring SONET/SDH Interfaces in JunosE Physical Layer Configuration Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces.
79Copyright © 2010, Juniper Networks, Inc.
Page 80
ERX 11.3.x Module Guide
Service Module (SM) Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SERVICE MODULE
No I/O module
Not applicable
First supported: 5.1.0
Final supported: Not applicable
130 W
Tunnel Service for IP tunnels, L2F tunnels, and LNS termination
EFA ASIC
IP tunnels
LNS termination
Network Address Translation
Stateful firewall
See “Service Modules” on page 102 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
Multiple SMs provide redundancy.
See JunosE Physical Layer Configuration Guide, Chapter 6, Managing Tunnel-Service and IPSec-Service Interfaces
Not applicable
See “Module LEDs” on page 109.
See Monitoring Tunnel-Service Interfaces in JunosE Physical Layer Configuration Guide, Chapter 6, Managing Tunnel-Service and IPSec-Service Interfaces.
Copyright © 2010, Juniper Networks, Inc.80
Page 81
SRP-5G+ Module Combination (1-GB Memory)
SRP-5G+ Module Combination (1-GB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SRP-5G+
SRP I/O
7
First supported: 4.1.3 or later 4.1.x release, 5.0.4 or later 5.0.x release, 5.1.2 or higher-numbered release, 5.2.0
Final supported: Not applicable
125 W
Switch route processor (5 Gbps)
Has a minimum of 1 GB of error checking and correction (ECC) memory with a 1-GB nonvolatile storage (NVS) card.
The 512–MB version has reached end-of-life.
Not applicable
Ethernet (IEEE 802.3)
10/100Base-T
RS-232
Not applicable
ERX705 Broadband Services Router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
SRP-5G+
1:1 redundancy
Terminal blocks
BNC, 75–ohm
Wire wrap posts
RJ-45
RS-232 (DB-9)
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Modules in JunosE System Basics Configuration Guide, Chapter 6, Managing Modules.
81Copyright © 2010, Juniper Networks, Inc.
Page 82
ERX 11.3.x Module Guide
SRP-10G Module Combination (2-GB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SRP-10G
SRP I/O
7
First supported: 4.1.3 or later 4.1.x release, 5.0.4 or later 5.0.x release, 5.1.2 or higher-numbered release, 5.2.0
Final supported: Not applicable
125 W
Switch route processor (10 Gbps)
Has a minimum of 2 GB of error checking and correction (ECC) memory with a 1-GB nonvolatile storage (NVS) card.
The 512–MB version has reached end-of-life.
Not applicable
Ethernet (IEEE 802.3)
10/100Base-T
RS-232
Not applicable
ERX710 Router
ERX1410 Router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
SRP-10G
1:1 redundancy
Terminal blocks
BNC, 75–ohm
Wire wrap posts
RJ-45
RS-232 (DB-9)
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Modules in JunosE System Basics Configuration Guide, Chapter 6, Managing Modules.
Copyright © 2010, Juniper Networks, Inc.82
Page 83
SRP-40G PLUS Module Combination (2-GB Memory)
SRP-40G PLUS Module Combination (2-GB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SRP module compatibility
SRP-40G PLUS
SRP I/O
7
First supported: 4.0.0
Final supported: Not applicable
210 W
Switch route processor (40 Gbps)
Has a minimum of 2 GB of error checking and correction (ECC) memory with a 1-GB nonvolatile storage (NVS) card.
Not applicable
Ethernet (IEEE 802.3)
10/100Base-T
RS-232
Not applicable
ERX1440 router
SRP-40G
SRP-40G PLUS
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
1:1 redundancy
Terminal blocks
BNC
BNC, 75–ohm
Wire wrap posts
RJ-45
RS-232 (DB-9)
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Modules in JunosE System Basics Configuration Guide, Chapter 6, Managing Modules.
83Copyright © 2010, Juniper Networks, Inc.
Page 84
ERX 11.3.x Module Guide
SRP-SE10G Module Combination (1-GB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
SRP-SE10G
SRP-SE I/O
2
First supported: 5.3.0
Final supported: Not applicable
35 W
Switch route processor for ERX310 router only (10 Gbps)
Not applicable
Ethernet (IEEE 802.3)
10/100Base-T
RS-232
Not applicable
ERX310 router
SRP-SE10G
Not applicable
Cables and connectors
LEDs
Alarms, errors, and events
RJ-45
RS-232 (DB-9)
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See “Module LEDs” on page 109.
See Monitoring Modules in JunosE System Basics Configuration Guide, Chapter 6, Managing Modules.
Copyright © 2010, Juniper Networks, Inc.84
Page 85
T3 ATM Module Combination (4 Ports)
T3 ATM Module Combination (4 Ports)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
4xDS3 ATM I/O
4
First supported: 4.1.0 (128 MB), 5.0.0 (256 MB)
Final supported: Not applicable
130 W
Can use either the 128-MB OCx/STMxATMline module or the 256-MB OCx/STMx /DS3-ATM line module.
Unchannelized T3 for ATM
EFA ASIC
ATM/AAL5
See “Unchannelized T3 Modules” on page 105 for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
75-ohm connector
The line interface unit supports two line buildouts:
0–68.5 m (0–225 feet)
69–137 m (226–450 feet)
Signal strength is software controlled.
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy ­Electrical Interfaces (1999) for cable lengths up to 201 m (660 feet).
See “Module LEDs” on page 109.
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 2, Configuring T3 and E3 Interfaces.
85Copyright © 2010, Juniper Networks, Inc.
Page 86
Page 87
APPENDIX A
Module Protocol Support
This appendix lists the layer 2 and layer 3 protocols and applications that line modules and their corresponding I/O modules support. Modules are identified by their physical labels. See Table 1 on page 3 for a list of modules and their identifying labels.
The designation “not yet fully qualified” that appears in some tables in this appendix indicates that support for the protocol or application on the specified module has not yet been fully qualified by Juniper Networks. If you use a feature before it has been fully qualified, it is your responsibility to ensure that it operates correctly in your targeted configuration.
This appendix contains the following sections:
Ethernet Modules on page 87
OCx/STMx GE/FE Modules on page 94
OCx/STMx ATM Modules on page 97
OCx/STMx POS and OC48 Modules on page 99
Service Modules on page 102
Unchannelized T3 Modules on page 105
Ethernet Modules
Table 11: Fast Ethernet Modules
tunnels
GE/FE Line Module with FE-8 I/O and FE-8 SFP I/O ModulesProtocol or Application
YesAccepts traffic destined for GRE tunnels or DVMRP (IP-in-IP)
NoAPS/MSP
NoATM
NoBERT
YesBFD
87Copyright © 2010, Juniper Networks, Inc.
Page 88
ERX 11.3.x Module Guide
Table 11: Fast Ethernet Modules (continued)
GE/FE Line Module with FE-8 I/O and FE-8 SFP I/O ModulesProtocol or Application
YesBGP
YesBGP/MPLS VPNs
NoBridged Ethernet
NoBridged IP
NoCisco HDLC
YesDHCP external server
YesDHCP local server
YesDVMRP and GRE support—access side
NoDVMRP and GRE support—server side
YesDynamic interfaces
YesEthernet raw mode encapsulation in Martini layer 2 circuits
NoF4 OAM and F5 OAM (ATM administration)
NoFDL (facilities data link)
YesFirewall
NoFrame Relay
Yes (including fast reconnection of PPPoE subscribers)ICR
YesIEEE 802.3ad link aggregation
NoIEEE 802.3ah OAM link-fault management
YesIP
YesIP multicast
NoIP reassembly for tunneled packets
NoIPSec
YesIPv6
Copyright © 2010, Juniper Networks, Inc.88
Page 89
Table 11: Fast Ethernet Modules (continued)
Appendix A: Module Protocol Support
GE/FE Line Module with FE-8 I/O and FE-8 SFP I/O ModulesProtocol or Application
YesIPv6 multicast
YesIPv6 neighbor discovery
YesIS-IS
YesJ-Flow Statistics
NoL2TP/IPSec
YesLAC support—access side
YesLAC support—peer side
YesLNS support—peer side
edge (CE) and provider edge (PE) devices
NoLocal loopback
NoMDL (maintenance data link)
YesMobile IP home agent
YesMPLS
YesMPLS L2VPNs over the LAGs configured between customer
NoMultilink Frame Relay
NoMultilink PPP
YesNetwork Address Translation (NAT)
NoNBMA (multipoint ATM)
YesOSPF
YesPacket Mirroring
NoPacket over SONET
NoPPP
YesPPPoE
NoRemote loopback
89Copyright © 2010, Juniper Networks, Inc.
Page 90
ERX 11.3.x Module Guide
Table 11: Fast Ethernet Modules (continued)
circuits
GE/FE Line Module with FE-8 I/O and FE-8 SFP I/O ModulesProtocol or Application
YesRIP
YesSubscriber interfaces (static)
YesSubscriber interfaces (dynamic)
YesS-VLAN subinterface with an untagged C-VLAN ID in Martini
YesTransparent bridging
NoTunnel-server ports
NoUnified ISSU
Table 12: Gigabit Ethernet Modules
GE/FE Line Modules with GE I/O ModulesProtocol or Application
GRE tunnels or DVMRP (IP-in-IP) tunnels
YesVPLS (network interfaces)
YesVPLS (virtual core interfaces)
YesVRRP
GE-2 Line Module or GE-HDE Line Module with GE-2 SFP I/O (formerly
GE-2 APS I/O or 2XGE APS I/O)
GE-HDE Line Module with GE-8 I/O Modules
YesYesYesAccepts traffic destined for
NoNoNoAPS/MSP
NoNoNoATM
NoNoNoBERT
YesYesNoBFD
YesYesYesBGP
YesYesYesBGP/MPLS VPNs
NoNoNoBridged Ethernet
Copyright © 2010, Juniper Networks, Inc.90
Page 91
Table 12: Gigabit Ethernet Modules (continued)
GE/FE Line Modules with GE I/O ModulesProtocol or Application
support—access side
support—server side
GE-2 Line Module or GE-HDE Line Module with GE-2 SFP I/O (formerly
GE-2 APS I/O or 2XGE APS I/O)
Appendix A: Module Protocol Support
GE-HDE Line Module with GE-8 I/O Modules
NoNoNoBridged IP
NoNoNoCisco HDLC
YesYesYesDHCP external server
YesYesYesDHCP local server
YesYesYesDVMRP and GRE
YesYesNoDVMRP and GRE
encapsulation in Martini layer 2 circuits
administration)
ICR
management
Yes (including fast reconnection of PPPoE subscribers)
Yes (including fast reconnection of PPPoE subscribers)
YesYesYesDynamic interfaces
YesYesYesEthernet raw mode
NoNoNoF4 OAM and F5 OAM (ATM
NoNoNoFDL (facilities data link)
NoYes (not yet fully qualified)YesFirewall
NoNoNoFrame Relay
Yes (including fast reconnection of PPPoE subscribers)
YesYesNoIEEE 802.3ad link aggregation
YesYesNoIEEE 802.3ah OAM link-fault
YesYesYesIP
packets
YesYesYesIP multicast
YesYesNoIP reassembly for tunneled
91Copyright © 2010, Juniper Networks, Inc.
Page 92
ERX 11.3.x Module Guide
Table 12: Gigabit Ethernet Modules (continued)
GE/FE Line Modules with GE I/O ModulesProtocol or Application
GE-2 Line Module or GE-HDE Line Module with GE-2 SFP I/O (formerly
GE-2 APS I/O or 2XGE APS I/O)
GE-HDE Line Module with GE-8 I/O Modules
NoNoNoIPSec
YesYesYesIPv6
YesYesYesIPv6 multicast
YesYesYesIPv6 neighbor discovery
YesYesYesIS-IS
YesYesYesJ-Flow Statistics
configuredbetween customer edge (CE) and provider edge (PE) devices
NoNoNoL2TP/IPSec
YesYesYesLAC support—access side
YesYesYesLAC support—peer side
YesYesYesLNS support—peer side
NoNoNoLocal loopback
NoNoNoMDL (maintenance data link)
Yes (not yet fully qualified)Yes (not yet fully qualified)YesMobile IP home agent
YesYesYesMPLS
NoYesYesMPLS L2VPNs over the LAGs
NoNoNoMultilink Frame Relay
NoMultilink PPP
Yes (with fragmentation and reassembly; over MPL2TP on shared tunnel-server port; dynamic only)
Yes (with fragmentation and reassembly; over MPL2TP on shared tunnel-server port; dynamic only)
(NAT)
NoYes (not yet fully qualified)YesNetwork Address Translation
NoNoNoNBMA (multipoint ATM)
Copyright © 2010, Juniper Networks, Inc.92
Page 93
Table 12: Gigabit Ethernet Modules (continued)
GE/FE Line Modules with GE I/O ModulesProtocol or Application
GE-2 Line Module or GE-HDE Line Module with GE-2 SFP I/O (formerly
GE-2 APS I/O or 2XGE APS I/O)
Appendix A: Module Protocol Support
GE-HDE Line Module with GE-8 I/O Modules
YesYesYesOSPF
YesYesYesPacket Mirroring
NoNoNoPacket over SONET
NoNoNoPPP
YesYesYesPPPoE
NoNoNoRemote loopback
(dynamic)
untaggedC-VLAN ID in Martini circuits
YesYesYesRIP
Yes (GRE tunnels only)Yes (GRE tunnels only)YesSubscriber interfaces (static)
YesYesYesSubscriber interfaces
YesYesYesS-VLAN subinterface with an
YesYesYesTransparent bridging
Yes (shared only)Yes (shared only)NoTunnel-server ports
YesYesYesUnified ISSU
YesYesYesVPLS (network interfaces)
YesYesYesVPLS (virtual core interfaces)
YesYesYesVRRP
93Copyright © 2010, Juniper Networks, Inc.
Page 94
ERX 11.3.x Module Guide
OCx/STMx GE/FE Modules
Table 13: OCx/STMx GE/FE Modules
(IP-in-IP) tunnels
OCx/STMx GE/FE Line Modules with OC3-2 GE APS I/O Modules
(OC3/STM1 ATM Interfaces)Protocol or Application
OCx/STMx GE/FE Line Modules with OC3-2 GE APS I/O Modules
(Gigabit Ethernet Interfaces)
YesYesAccepts traffic destined for GRE tunnels or DVMRP
NoNoAPS/MSP
NoYesATM
NoNoBERT
NoNoBFD
YesYesBGP
YesYesBGP/MPLS VPNs
NoYesBridged Ethernet
NoYesBridged IP
NoNoCisco HDLC
YesYesDHCP external server
YesYesDHCP local server
YesYesDVMRP and GRE support—access side
NoNoDVMRP and GRE support—server side
YesYesDynamic interfaces
NoYesF4 OAM and F5 OAM (ATM administration)
NoNoFDL (facilities data link)
YesYesFirewall
NoNoFrame Relay
YesNoICR
Copyright © 2010, Juniper Networks, Inc.94
Page 95
Table 13: OCx/STMx GE/FE Modules (continued)
OCx/STMx GE/FE Line Modules with OC3-2 GE APS I/O Modules
(OC3/STM1 ATM Interfaces)Protocol or Application
Appendix A: Module Protocol Support
OCx/STMx GE/FE Line Modules with OC3-2 GE APS I/O Modules
(Gigabit Ethernet Interfaces)
NoNoIEEE 802.3ad link aggregation
NoNoIEEE 802.3ah OAM link-fault management
YesYesIP
YesYesIP multicast
NoNoIP reassembly for tunneled packets
NoNoIPSec
YesYesIPv6
YesYesIPv6 multicast
YesYesIPv6 neighbor discovery
YesYesIS-IS
YesYesJ-Flow Statistics
NoNoL2TP/IPSec
YesYesLAC support—access side
YesYesLAC support—peer side
YesYesLNS support—peer side
NoNoLocal loopback
NoNoMDL (maintenance data link)
Yes (not yet fully qualified)NoMobile IP home agent
YesYesMPLS
Multilink PPP
NoNoMultilink Frame Relay
NoYes (with fragmentation and
reassembly)
95Copyright © 2010, Juniper Networks, Inc.
Page 96
ERX 11.3.x Module Guide
Table 13: OCx/STMx GE/FE Modules (continued)
OCx/STMx GE/FE Line Modules with OC3-2 GE APS I/O Modules
(OC3/STM1 ATM Interfaces)Protocol or Application
OCx/STMx GE/FE Line Modules with OC3-2 GE APS I/O Modules
(Gigabit Ethernet Interfaces)
YesYesNetwork Address Translation (NAT)
NoYesNBMA (multipoint ATM)
YesYesOSPF
YesYesPacket Mirroring
NoNoPacket over SONET
NoYesPPP
Subscriber interfaces (static)
YesYesPPPoE
NoNoRemote loopback
YesYesRIP
YesYes (over bridged Ethernet and
IPoA)
YesYes (over bridged Ethernet)Subscriber interfaces (dynamic)
YesYesTransparent bridging
NoNoTunnel-server ports
NoNoUnified ISSU
YesYesVPLS (network interfaces)
YesYesVPLS (virtual core interfaces)
YesNoVRRP
Copyright © 2010, Juniper Networks, Inc.96
Page 97
OCx/STMx ATM Modules
Table 14: OCx/STMx ATM Modules
Appendix A: Module Protocol Support
(IP-in-IP) tunnels
OCx/STMx ATM Line Modules with OC3-4 I/O ModulesProtocol or Application
OCx/STMx ATM Line Modules with OC12/STM4 I/O Modules
YesYesAccepts traffic destined for GRE tunnels or DVMRP
YesNoAPS/MSP
YesYesATM
NoNoBERT
NoYesBFD
YesYesBGP
YesYesBGP/MPLS VPNs
YesYesBridged Ethernet
YesYesBridged IP
NoNoCisco HDLC
YesYesDHCP external server
YesYesDHCP local server
YesYesDVMRP and GRE support—access side
NoNoDVMRP and GRE support—server side
YesYesDynamic interfaces
YesYesF4 OAM and F5 OAM (ATM administration)
NoNoFDL (facilities data link)
YesYesFirewall
NoNoFrame Relay
NoNoICR
NoNoIEEE 802.3ad link aggregation
97Copyright © 2010, Juniper Networks, Inc.
Page 98
ERX 11.3.x Module Guide
Table 14: OCx/STMx ATM Modules (continued)
OCx/STMx ATM Line Modules with OC3-4 I/O ModulesProtocol or Application
OCx/STMx ATM Line Modules with OC12/STM4 I/O Modules
NoNoIEEE 802.3ah OAM link-fault management
YesYesIP
YesYesIP multicast
NoNoIP reassembly for tunneled packets
NoNoIPSec
YesYesIPv6
YesYesIPv6 multicast
YesYesIPv6 neighbor discovery
YesYesIS-IS
YesYesJ-Flow Statistics
NoNoL2TP/IPSec
Multilink PPP
Yes (with fragmentation and reassembly)
YesYesLAC support—access side
YesYesLAC support—peer side
YesYesLNS support—peer side
YesNoLocal loopback
NoNoMDL (maintenance data link)
NoNoMobile IP home agent
YesYesMPLS
NoNoMultilink Frame Relay
Yes (with fragmentation and reassembly)
YesYesNetwork Address Translation (NAT)
YesYesNBMA (multipoint ATM)
YesYesOSPF
Copyright © 2010, Juniper Networks, Inc.98
Page 99
Table 14: OCx/STMx ATM Modules (continued)
Appendix A: Module Protocol Support
Subscriber interfaces (static)
Unified ISSU
OCx/STMx ATM Line Modules with OC3-4 I/O ModulesProtocol or Application
Yes (over bridged Ethernet and IPoA)
Yes (only for non-channelized APS IOAs when APS is not configured)
OCx/STMx ATM Line Modules with OC12/STM4 I/O Modules
YesYesPacket Mirroring
NoNoPacket over SONET
YesYesPPP
YesYesPPPoE
NoNoRemote loopback
YesYesRIP
Yes (over bridged Ethernet and IPoA)
Yes (over bridged Ethernet)Yes (over bridged Ethernet)Subscriber interfaces (dynamic)
YesYesTransparent bridging
NoNoTunnel-server ports
Yes (only for non-channelized APS IOAs when APS is not configured)
OCx/STMx POS and OC48 Modules
Table 15: OCx/STMx POS and OC48 Modules
OCx/STMx POS Line Modules with OC3-4 I/O ModulesProtocol or Application
or DVMRP (IP-in-IP) tunnels
YesYesVPLS (network interfaces)
YesYesVPLS (virtual core interfaces)
NoNoVRRP
OCx/STMx POS Line Modules with OC12/STM4I/OModules
OC48 Line Module with OC48 Frame APS I/O Module
YesYesYesAccepts traffic destined for GRE tunnels
NoYesNoAPS/MSP
NoNoNoATM
NoNoNoBERT
99Copyright © 2010, Juniper Networks, Inc.
Page 100
ERX 11.3.x Module Guide
Table 15: OCx/STMx POS and OC48 Modules (continued)
DHCP external server
DHCP local server
OCx/STMx POS Line Modules with OC3-4 I/O ModulesProtocol or Application
Yes (for POS uplink interfaces; POS access interfaces not yet fully qualified)
Yes (for POS access interfaces; not yet fully qualified)
OCx/STMx POS Line Modules with OC12/STM4I/OModules
Yes (for POS uplink interfaces; POS access interfaces not yet fully qualified)
Yes (for POS access interfaces; not yet fully qualified)
OC48 Line Module with OC48 Frame APS I/O Module
NoNoNoBFD
YesYesYesBGP
YesYesYesBGP/MPLS VPNs
NoNoNoBridged Ethernet
NoNoNoBridged IP
YesYesYesCisco HDLC
Yes (for POS uplink interfaces; POS access interfaces not yet fully qualified)
Yes (for POS access interfaces; not yet fully qualified)
NoNoNoDVMRP and GRE support—access side
administration)
management
YesYesYesDVMRP and GRE support—server side
NoNoNoDynamic interfaces
NoNoNoF4 OAM and F5 OAM (ATM
NoNoNoFDL (facilities data link)
YesYesYesFirewall
YesYesYesFrame Relay
NoNoNoICR
NoNoNoIEEE 802.3ad link aggregation
NoNoNoIEEE 802.3ah OAM link-fault
YesYesYesIP
YesYesYesIP multicast
Copyright © 2010, Juniper Networks, Inc.100
Loading...