E Series™ Broadband Services Routers
ERX™ Module Guide
Release 11.1.x
Juniper Networks, Inc.
1194 North Mathilda Avenue
Sunnyvale, California 94089
USA
408-745-2000
www.juniper.net
Published: 2010-04-06
ERX 11.1.x Module Guide
This guide provides an overview and description of the line modules (LMs), switch
route processor (SRP) modules, and I/O modules available for the following Juniper
Networks E Series Broadband Services Routers: ERX14xx models, ERX7xx models,
and the ERX310 router.
Unless otherwise specified, all line modules pair with I/O modules to create a module
combination. Each module combination provides particular capabilities and
connections in an ERX router.
NOTE: A release may support multiple versions of a module. For information, see
Software Compatibility in JUNOSe System Basics Configuration Guide, Chapter 6,
Managing Modules.
Table 1 on page 3 lists the module combinations supported by ERX routers.
This book also contains three appendixes:
■ Module Protocol Support on page 107
■ Module LEDs on page 133
■ Module Name Cross-Reference Information on page 139
■ Product Reclamation and Recycling Program on page 143
For more information about ERX routers and modules, refer to the following books:
■ Modules that have reached end-of-life—ERX End-of-Life Module Guide
■ Module installation and maintenance—ERX Hardware Guide
■ Managing ERX routers—JUNOSe System Basics Configuration Guide
■ Configuring ERX modules—JUNOSe Link Layer Configuration Guide
2 ■
Table 1: ERX Module Combinations
Channelized OC3/STM1
cOC3/STM1 multimode
Line Module
Label Combination Name and Type
cOCx/STMx
F0
I/O Module
Label
I/O
MULTIMODE
First
JUNOSe
Support
Page
9 2.2.0 cOC3 STM1 F0
cOC3/STM1 single-mode intermediate
reach
cOC3/STM1 single-mode long reach
Channelized OC12/STM4
cOC12/STM4 multimode without APS/MSP
redundancy
cOC12/STM4 single-mode intermediate
reach without APS/MSP redundancy
cOC12/STM4 single-mode intermediate
reach with APS/MSP redundancy
cOC12/STM4 single-mode long reach
cOCx/STMx
F0
cOCx/STMx
F0
cOCx/STMx
F0
cOCx/STMx
F0
cOCx/STMx
F0
cOCx/STMx
F0
I/O
SINGLE MODE
I/O
LONG HAUL
F0 I/O
MULTI MODE
F0 I/O
SINGLE MODE
COC12 F0 APS
SINGLE MODE
LONG HAUL
11 2.2.0 cOC3 STM1 F0
13 2.2.0 cOC3 STM1 F0
15 2.2.0 cOC12 STM4
17 2.2.0 cOC12 STM4
19 6.1.3,
7.0.2,
7.2.0
21 2.2.0 cOC12 STM4
Channelized T3
E3
Fast Ethernet
Gigabit Ethernet (1-port)
23 3.2.0 CT3/T3 12 I/O CT3/T3-F0 CT3/T3 12 (12 ports)
COCX-F3 E3 Frame (12 ports)
24 4.0.2 E3-12
FRAME I/O
25 5.0.0 FE-8 I/O GE/FE FE-8 (8 ports) (256-MB memory)
26 6.0.0 FE-8 SFP I/O GE/FE FE-8 SFP (8 ports) (256-MB memory)
28 5.0.0 GE I/O SFP GE/FE GE 1000Base-SX (256-MB memory)
■ 3
ERX 11.1.x Module Guide
Table 1: ERX Module Combinations (continued)
Line Module
Label Combination Name and Type
I/O Module
Label
First
JUNOSe
Support
Page
30 5.0.0 GE I/O SFP GE/FE GE 1000Base-LH (256-MB memory)
32 5.0.0 GE I/O SFP GE/FE GE 1000Base-ZX (256-MB memory)
Gigabit Ethernet (2-port)
GE/FE GE multimode
34 2.0.0 GE I/O
MULTI MODE
GE/FE GE single-mode
36 2.0.0 GE I/O
SINGLE MODE
GE-2 GE2 1000Base-SX
38 5.3.0 GE-2 SFP I/O
or
2XGE APS I/O
SFP or
GE-2 APS I/O
SFP
GE-2 GE2 1000Base-LH
40 5.3.0 GE-2 SFP I/O
or
2XGE APS I/O
SFP or
GE-2 APS I/O
SFP
GE-2 GE2 1000Base-ZX
42 5.3.0 GE-2 SFP I/O
or
GE High Density (HDE)
4 ■
2XGE APS I/O
SFP or
GE-2 APS I/O
SFP
GE-HDE GE High Density (2 ports)
44 7.0.0 GE-2 SFP I/O
or
2XGE APS I/O
SFP or
GE-2 APS I/O
SFP
46 7.0.0 GE-8 I/O GE-HDE GE High Density (8 ports)
Table 1: ERX Module Combinations (continued)
Line Module
Label Combination Name and Type
IPSec Service
IPSec Service
SERVICE
OC3/STM1 ATM
OC3/STM1 ATM multimode without
APS/MSP redundancy (256-MB memory)
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
I/O Module
Label
OC3-4 I/O
MULTI MODE
First
JUNOSe
Support
5.3.0
Page
48 4.0.2 No I/O module IPSEC
49 5.0.0,
OC3/STM1 ATM multimode with APS/MSP
redundancy
OC3/STM1 ATM single-mode intermediate
reach without APS/MSP redundancy
(256-MB memory)
OC3/STM1 ATM single-mode intermediate
reach with APS/MSP redundancy
OC3/STM1 ATM single-mode long reach
without APS/MSP redundancy (256-MB
memory)
OC3/STM1 GE/FE
OC3/STM1 GE/FE
OC3/STM1 POS
OC3/STM1 POS multimode without
APS/MSP redundancy
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OC3/STM1
GE/FE
OCx/STMx
POS
4XOC3 APS
I/O
MULTI MODE
OC3-4 I/O
SINGLE MODE
4XOC3
APS I/O
SINGLE MODE
OC3-4 I/O
LONG HAUL
APS I/O
MULTI MODE
51 5.1.2
5.2.0
(APS/MSP)
53 5.0.0,
5.3.0
55 5.1.2
5.2.0
(APS/MSP)
57 5.0.0,
5.3.0
59 6.1.0 OC3–2 GE
63 2.0.0 OC3-4 I/O
OC3/STM1 POS multimode with APS/MSP
redundancy
OC3/STM1 POS single-mode intermediate
reach without APS/MSP redundancy
OCx/STMx
POS
OCx/STMx
POS
4XOC3 APS
I/O
MULTI MODE
SINGLE MODE
65 5.1.2
5.2.0
(APS/MSP)
67 2.0.0 OC3-4 I/O
■ 5
ERX 11.1.x Module Guide
Table 1: ERX Module Combinations (continued)
Line Module
Label Combination Name and Type
I/O Module
Label
First
JUNOSe
Support
Page
OC3/STM1 POS single-mode intermediate
reach with APS/MSP redundancy
OC3/STM1 POS single-mode long reach
OC12/STM4 ATM
OC12/STM4 ATM multimode without
APS/MSP redundancy (256-MB memory)
OC12/STM4 ATM multimode with
APS/MSP redundancy
OC12/STM4 ATM single-mode
intermediate reach without APS/MSP
redundancy (256-MB memory)
OC12/STM4 ATM single-mode
intermediate reach with APS/MSP
redundancy
OCx/STMx
POS
OCx/STMx
POS
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
4XOC3 APS
I/O
SINGLE MODE
LONG HAUL
OC12 STM4
I/O
MULTI MODE
OC12 STM4
APS
MULTI MODE
OC12 STM4
I/O
SINGLE MODE
OC12 STM4
APS
SINGLE MODE
69 5.1.2
5.2.0
(APS/MSP)
71 2.0.0 OC3-4 I/O
73 5.0.0,
5.3.0
75 2.0.0 (128
MB)
5.0.0 (256
MB)
77 5.0.0,
5.3.0
79 2.0.0 (128
MB)
5.0.0 (256
MB)
OC12/STM4 ATM single-mode long reach
without APS/MSP redundancy (256-MB
memory)
OC12/STM4 ATM single-mode long reach
with APS/MSP redundancy
OC12/STM4 POS
OC12/STM4 POS multimode without
APS/MSP redundancy
6 ■
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
OCx/STMx
POS
OC12 STM4
I/O
LONG HAUL
OC12 STM4
APS
LONG HAUL
I/O
MULTI MODE
5.3.0
81 5.0.0,
83 2.0.0 (128
MB)
5.0.0 (256
MB)
85 2.0.0 OC12 STM4
Table 1: ERX Module Combinations (continued)
Line Module
Label Combination Name and Type
I/O Module
Label
First
JUNOSe
Support
Page
OC12/STM4 POS multimode with
APS/MSP redundancy
OC12/STM4 POS single-mode
intermediate reach without APS/MSP
redundancy
OC12/STM4 POS single-mode
intermediate reach with APS/MSP
redundancy
OC12/STM4 POS single-mode long reach
without APS/MSP redundancy
OC12/STM4 POS single-mode long reach
with APS/MSP redundancy
OC48/STM16
OCx/STMx
POS
OCx/STMx
POS
OCx/STMx
POS
OCx/STMx
POS
OCx/STMx
POS
OC48 OC48/STM16 POS single-mode short reach
APS
87 2.0.0 OC12 STM4
MULTI MODE
89 2.0.0 OC12 STM4
I/O
SINGLE MODE
91 2.0.0 OC12 STM4
APS
SINGLE MODE
93 2.0.0 OC12 STM4
I/O
LONG HAUL
95 2.0.0 OC12 STM4
APS
LONG HAUL
97 4.1.x OC48 FRAME
APS
Service Module (SM)
SM
SRPs
SRP-40G PLUS (2-GB memory)
MODULE
PLUS
98 5.1.0 No I/O module SERVICE
SRP I/O SRP-5G+ SRP-5G+ (1-GB memory)
99 4.1.3,
5.0.4,
5.1.2,
5.2.0
SRP I/O SRP-5G+ SRP-5G+ (2-GB memory)
100 4.1.3,
5.0.4,
5.1.2,
5.2.0
SRP I/O SRP-10G SRP-10G (2-GB memory)
101 4.1.3,
5.0.4,
5.1.2,
5.2.0
102 4.0.0 SRP I/O SRP-40G
■ 7
ERX 11.1.x Module Guide
Table 1: ERX Module Combinations (continued)
Line Module
Label Combination Name and Type
T3
T3 ATM (4 ports)
OCx/STMx
ATM or
OCx/STMx
/DS3-ATM
I/O Module
Label
4xDS3 ATM
I/O
First
JUNOSe
Support
MB)
5.0.0 (256
MB)
Page
103 5.3.0 SRP-SE I/O SRP-SE10G SRP-SE10G (1-GB memory)
104 4.1.0 (128
105 4.0.2 CT3/T3 12 I/O COCX-F3 T3 Frame (12 ports)
8 ■
cOC3/STM1 Multimode Module Combination
cOC3/STM1 Multimode Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC3 STM1 F0 I/O
MULTI MODE
4
■
First supported: 2.2.0
■
Final supported: Not applicable
■
130 W
■
OC3/STM1 channelized to DS3, DS1, E1, and DS0
■
Supports either E1 or T1 operation, but not E1 and T1 operation simultaneously
■
EFA ASIC
■
OC3/STM1
■
DS3
■
T1, E1
■
DS0
■
HDLC framing
■
See “ Channelized OCx/STMx Modules” on page 107 for information about the layer
■
2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
cOC3/STM1 Multimode Module Combination ■ 9
ERX 11.1.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
Up to four SC full duplex connectors
■
Tx power:
■
min: –19 dBm
■
max: –14 dBm
■
Center wavelength: 1310 nm
■
Rx input power:
■
min: –30 dBm
■
max: –14 dBm
■
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of
■
0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 4,
■
Configuring Channelized OCx/STMx Interfaces.
10 ■ cOC3/STM1 Multimode Module Combination
cOC3/STM1 Single-Mode Intermediate Reach Module Combination
cOC3/STM1 Single-Mode Intermediate Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC3 STM1 F0 I/O
SINGLE MODE
4
■
First supported: 2.2.0
■
Final supported: Not applicable
■
130 W
■
OC3/STM1 channelized to DS3, DS1, E1, and DS0
■
EFA ASIC
■
OC3/STM1
■
DS3, DS1
■
T1, E1
■
DS0
■
HDLC framing
■
See “ Channelized OCx/STMx Modules” on page 107 for information about the
■
layer 2 and layer 3 protocols and applications that this module combination
supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
cOC3/STM1 Single-Mode Intermediate Reach Module Combination ■ 11
ERX 11.1.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
Up to four SC full duplex connectors
■
Tx power:
■
min: –15 dBm
■
max: –8 dBm
■
Center wavelength: 1310 nm
■
Rx input power:
■
min: –31 dBm
■
max: –8 dBm
■
Rated for 15 km (9.3 miles) of 9-micron core cable
■
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 4,
■
Configuring Channelized OCx/STMx Interfaces.
12 ■ cOC3/STM1 Single-Mode Intermediate Reach Module Combination
cOC3/STM1 Single-Mode Long Reach Module Combination
cOC3/STM1 Single-Mode Long Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC3 STM1 F0 I/O
LONG HAUL
4
■
First supported: 2.2.0
■
Final supported: Not applicable
■
130 W
■
OC3/STM1 channelized to DS3, DS1, E1, and DS0
■
EFA ASIC
■
OC3/STM1
■
DS3, DS1
■
T1, E1
■
DS0
■
HDLC framing
■
See “ Channelized OCx/STMx Modules” on page 107 for information about the
■
layer 2 and layer 3 protocols and applications that this module combination
supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
cOC3/STM1 Single-Mode Long Reach Module Combination ■ 13
ERX 11.1.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
Up to four SC full duplex connectors
■
Tx power:
■
min: –5.0 dBm
■
max: 0 dBm
■
Center wavelength: 1310 nm
■
Rx input power:
■
min: –34 dBm
■
max: –7 dBm
■
Fiber type: 9-micron core
■
Rated for 40 km (24.8 miles) of 9-micron core cable
■
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 4,
■
Configuring Channelized OCx/STMx Interfaces.
14 ■ cOC3/STM1 Single-Mode Long Reach Module Combination
cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination
cOC12/STM4 Multimode Without APS/MSP Redundancy Module
Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC12 STM4 F0 I/O
MULTI MODE
1
■
First supported: 2.2.0
■
Final supported: Not applicable
■
130 W
■
OC12/STM4 channelized to DS3, DS1, E1, and DS0
■
EFA ASIC
■
OC12/STM4
■
OC3/STM1
■
DS3, DS1
■
T1, E1
■
DS0
■
HDLC framing
■
See “ Channelized OCx/STMx Modules” on page 107 for information about the layer
■
2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination ■ 15
ERX 11.1.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
■
Tx power:
■
min: –19 dBm
■
max: –14 dBm
■
Center wavelength: 1310 nm
■
Rx input power:
■
min: –30 dBm
■
max: –14 dBm
■
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9
■
dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 4,
■
Configuring Channelized OCx/STMx Interfaces.
16 ■ cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination
cOC12/STM4 Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination
cOC12/STM4 Single-Mode Intermediate Reach Without APS/MSP
Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC12 STM4 F0 I/O
SINGLE MODE
1
■
First supported: 2.2.0
■
Final supported: Not applicable
■
130 W
■
OC12/STM4 channelized to DS3, DS1, E1, and DS0
■
EFA ASIC
■
OC12/STM4
■
OC3/STM1
■
DS3, DS1
■
T1, E1
■
DS0
■
HDLC framing
■
See “ Channelized OCx/STMx Modules” on page 107 for information about the
■
layer 2 and layer 3 protocols and applications that this module combination
supports.
Model compatibility
SRP module compatibility
Module redundancy support
cOC12/STM4 Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination ■ 17
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
ERX 11.1.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
■
Tx power:
■
min: –15 dBm
■
max: –8 dBm
■
Center wavelength: 1310 nm
■
Rx input power:
■
min: –31 dBm
■
max: –8 dBm
■
Rated for 15 km (9.3 miles) of 9-micron core cable
■
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 4,
■
Configuring Channelized OCx/STMx Interfaces.
18 ■ cOC12/STM4 Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination
cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination
cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP
Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
COC12 F0 APS
SINGLE MODE
2
■
1 active, 1 redundant
■
First supported: 6.1.3 or later 6.1.x release, 7.0.2 or later 7.0.x release, 7.2.0 and
■
higher-numbered release
130 W
■
OC12/STM4 channelized to DS3, DS1, E1, and DS0
■
EFA ASIC
■
OC12/STM4
■
OC3/STM1
■
DS3, DS1
■
T1, E1
■
DS0
■
HDLC framing
■
See “ Channelized OCx/STMx Modules” on page 107 for information about the layer
■
2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination ■ 19
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
ERX 11.1.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
■
Tx power:
■
min: –15 dBm
■
max: –8 dBm
■
Center wavelength: 1310 nm
■
Rx input power:
■
min: –31 dBm
■
max: –7 dBm
■
Rated for 15 km (9.3 miles) of 9-micron core cable
■
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 4,
■
Configuring Channelized OCx/STMx Interfaces.
20 ■ cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination
cOC12/STM4 Single-Mode Long Reach Module Combination
cOC12/STM4 Single-Mode Long Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC12 STM4
LONG HAUL
1 active, 1 redundant
■
First supported: 2.2.0
■
Final supported: Not applicable
■
130 W
■
OC12/STM4 channelized to DS3, DS1, E1, and DS0
■
EFA ASIC
■
OC12/STM4
■
OC3/STM1
■
DS3, DS1
■
T1, E1
■
DS0
■
HDLC framing
■
See “ Channelized OCx/STMx Modules” on page 107 for information about the
■
layer 2 and layer 3 protocols and applications that this module combination
supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
cOC12/STM4 Single-Mode Long Reach Module Combination ■ 21
ERX 11.1.x Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
■
Tx power:
■
min: –5.0 dBm
■
max: 0 dBm
■
Center wavelength: 1310 nm
■
Rx input power:
■
min: –34 dBm
■
max: –7 dBm
■
Fiber type: 9-micron core
■
Rated for 40 km (24.8 miles) of 9-micron core cable
■
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 4,
■
Configuring Channelized OCx/STMx Interfaces.
22 ■ cOC12/STM4 Single-Mode Long Reach Module Combination
CT3/T3 12 Module Combination (12 Ports)
CT3/T3 12 Module Combination (12 Ports)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SRP module compatibility
CT3/T3-F0
CT3/T3 12 I/O
12
■
First supported: 3.2.0
■
Final supported: Not applicable
■
130 W
■
Channelized and unchannelized T3
■
EFA ASIC
■
DS3, DS1, DS0
■
HDLC framing
■
See “ Channelized T3 Modules” on page 110 for information about the layer 2 and
■
layer 3 protocols and applications that this module combination supports.
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
BT43 SMB connector
■
Cable that adapts to 75-ohm BNC is available.
■
The line interface unit supports two line buildouts:
■
0–68.5 m (0–225 feet)
■
69–137 m (226–450 feet)
■
Signal strength is software controlled.
■
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy -
■
Electrical Interfaces (1999) for cable lengths up to 201 m (660 feet).
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 1,
■
Configuring Channelized T3 Interfaces.
CT3/T3 12 Module Combination (12 Ports) ■ 23
ERX 11.1.x Module Guide
E3 Frame Module Combination (12 Ports)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
COCX-F3
E3-12
FRAME I/O
12
■
First supported: 4.0.2
■
Final supported: Not applicable
■
135 W
■
Unchannelized E3 for Frame
■
EFA ASIC
■
E3
■
HDLC framing
■
See “ Unchannelized E3 Modules” on page 128 for information about the layer 2
■
and layer 3 protocols and applications that this module combination supports.
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
1:N redundancy
■
NOTE: Line module redundancy is not supported on the ERX310 router.
■
BT43 SMB connector
■
Cable that adapts to 75-ohm BNC is available.
■
The transmitted signal complies with ITUT G.703, Physical/electrical
■
characteristics of hierarchical digital interfaces (November 2001) for cable lengths
from 0–137 m (0–450 feet).
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 2,
■
Configuring T3 and E3 Interfaces.
24 ■ E3 Frame Module Combination (12 Ports)
FE-8 Module Combination (8 Ports) (256-MB Memory)
FE-8 Module Combination (8 Ports) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
FE-8 I/O
8
■
First supported: 5.0.0
■
Final supported: Not applicable
■
The GE/FE line module must have a minimum of 256 MB of memory to be used
■
with JUNOSe Release 5.3.0 or a higher-numbered release.
130 W
■
Fast Ethernet
■
EFA ASIC
■
IEEE 802.3 standards compliance
■
10/100Base-T
■
See “ Ethernet Modules” on page 112 for information about the layer 2 and layer
■
3 protocols and applications that this module combination supports.
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
Not applicable
■
RJ-45 connectors
■
For 10-Mbps operation, use CAT 3, 4, or 5 UTP cable.
■
For 100-Mbps operation, use only CAT 5 UTP cable.
■
The transmitted signal complies with IEEE 802.3/802.3u for cable lengths up to
■
100 m (328 feet).
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide,
■
Chapter 5, Configuring Ethernet Interfaces.
FE-8 Module Combination (8 Ports) (256-MB Memory) ■ 25
ERX 11.1.x Module Guide
FE-8 SFP Module Combination (8 Ports) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
FE-8 SFP I/O
8
■
First supported: 6.0.0
■
Final supported: Not applicable
■
130 W
■
Fast Ethernet
■
The FE-8 SFP I/O module uses a range of small form-factor pluggable (SFP)
■
transceivers to support different modes and cable lengths.
EFA ASIC
■
IEEE 802.3 standards compliance
■
100Base-FX
■
See “ Ethernet Modules” on page 112 for information about the layer 2 and layer
■
3 protocols and applications that this module combination supports.
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP module compatibility
Module redundancy support
Cables and connectors (single-mode
fiber)
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
Not applicable
■
LC full duplex
■
Tx power:
■
min: –15 dBm
■
max: –8 dBm
■
Center wavelength: 1300 nm
■
Rx input power:
■
min: –28 dBm
■
max: –14 dBm
■
Rated for 10 km (6.2 miles) over 9-micron core cable
■
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
26 ■ FE-8 SFP Module Combination (8 Ports) (256-MB Memory)
Cables and connectors (multimode
fiber)
LEDs
Alarms, errors, and events
FE-8 SFP Module Combination (8 Ports) (256-MB Memory)
LC full duplex
■
Tx power: –20 dBm minimum and –14 dBm maximum
■
Center wavelength: 850 nm
■
Rx input power: –31 dBm minimum and –14 dBm maximum
■
Rated for 2 km (1.2 miles) over 62.5/125-micron core cable
■
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide,
■
Chapter 5, Configuring Ethernet Interfaces.
FE-8 SFP Module Combination (8 Ports) (256-MB Memory) ■ 27
ERX 11.1.x Module Guide
GE 1000Base-SX Module Combination (1 Port) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
GE/FE
GE I/O SFP
1 active, 1 redundant
■
First supported: 5.0.0
■
Final supported: Not applicable
■
130 W
■
Gigabit Ethernet
■
256 MB of memory
■
The 128-MB version has reached end-of-life.
■
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to
■
support different modes and cabling distances.
Uses either optical or copper SFPs.
■
The optical transceivers are 1000Base-SX compliant.
■
The copper transceivers are 1000Base-T compliant.
■
Single-strand SFPs can be used. These SFPs work in pairs and require a matching
■
SFP at the opposite end of the Ethernet connection. For example, an SFP rated at TX
1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the same
maximum operating range. See the following corresponding table (Single-strand SFPs
Pairing) for more information.
EFA ASIC
■
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
Cables and connectors (copper
SFP)
Ethernet (IEEE 802.3z)
■
1000Base-SX
■
See “ Ethernet Modules” on page 112 for information about the layer 2 and layer 3
■
protocols and applications that this module combination supports.
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
Not applicable
■
Maximum range is 100 meters on CAT5 cable.
■
28 ■ GE 1000Base-SX Module Combination (1 Port) (256-MB Memory)
Cables and connectors (SX)
LEDs
Alarms, errors, and events
GE 1000Base-SX Module Combination (1 Port) (256-MB Memory)
LC full duplex
■
Tx power:
■
min: –9.5 dBm
■
max: –4 dBm
■
Center wavelength: 850 nm
■
Rx input power:
■
min: –20 dBm
■
max: –0 dBm
■
Rated for 275 m (300 yards) over 62.5-micron core cable
■
Rated for 550 m (601 yards) over 50-micron core cable
■
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
■
See “ Module LEDs” on page 133.
■
See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide,
■
Chapter 5, Configuring Ethernet Interfaces.
Table 2: Single-strand SFPs Pairing
9 microns
9 microns
9 microns
9 microns
9 microns
9 microns
TX 1310, RX 1550
■
Pairs with TX 1550 / RX 1310
■
TX 1550 / RX 1310
■
Pairs with TX 1310, RX 1550
■
TX 1310, RX 1490
■
Pairs with TX 1490 / RX 1310
■
TX 1490 / RX 1310
■
Pairs with TX 1310, RX 1490
■
TX 1310, RX 1550
■
Pairs with TX 1550 / RX 1310
■
TX 1550, RX 1310
■
Pairs with TX 1310 / RX 1550
■
Maximum Operating Range (kilometers) Nominal Wavelength (nm) Fiber Type
10 (6.2 miles), matching SFP must have
the same operating range
10 (6.2 miles), matching SFP must have
the same operating range
10 (6.2 miles), matching SFP must have
the same operating range
10 (6.2 miles), matching SFP must have
the same operating range
40 (24.85 miles), matching SFP must
have the same operating range
40 (24.85 miles), matching SFP must
have the same operating range
GE 1000Base-SX Module Combination (1 Port) (256-MB Memory) ■ 29
ERX 11.1.x Module Guide
GE 1000Base-LH Module Combination (1 Port) (256-MB Memory)
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
GE/FE
GE I/O SFP
1 active, 1 redundant
■
First supported: 5.0.0
■
Final supported: Not applicable
■
130 W
■
Gigabit Ethernet
■
256 MB of memory
■
The 128-MB version has reached end-of-life.
■
The I/O module uses a range of small form-factor pluggable (SFP) transceivers to
■
support different modes and cabling distances.
Uses either optical or copper SFPs.
■
The optical transceivers are 1000Base-LX/LH compliant.
■
The copper transceivers are 1000Base-T compliant.
■
Single-strand SFPs can be used. These SFPs work in pairs and require a matching
■
SFP at the opposite end of the Ethernet connection. For example, an SFP rated at
TX 1310, RX 1550 must be paired with an SFP rated TX 1550, RX 1310 with the
same maximum operating range. See the following corresponding table (Single-strand
SFPs Pairing) for more information.
EFA ASIC
■
Capability
Software features
Model compatibility
SRP module compatibility
Module redundancy support
Cables and connectors (copper
SFP)
Ethernet (IEEE 802.3z)
■
1000Base-LH
■
See “ Ethernet Modules” on page 112 for information about the layer 2 and layer 3
■
protocols and applications that this module combination supports.
ERX7xx models
■
ERX14xx models
■
ERX310 router
■
SRP-5G+
■
SRP-10G
■
SRP-40G
■
SRP-40G PLUS
■
SRP-SE10G
■
Not applicable
■
Maximum range is 100 meters on CAT5 cable.
■
30 ■ GE 1000Base-LH Module Combination (1 Port) (256-MB Memory)