Juniper E SERIES BROADBAND SERVICES ROUTERS - E SERIES END-OF-LIFE MODULE GUIDE 6-10-2010, ERX310, E120, E320, ERX14 Series User Manual

...
E Series™ Broadband Services Routers
E Series™ End-of-Life Module Guide
Published: 2010-10-06
Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
This guide provides an overview and description of E Series modules that are end-of-life (EOL) and can no longer be ordered for the following routers:
Depending on the EOL schedule of a module, new software releases might not support the module.
Table 1 on page 3 lists EOL modules alphabetically. It lists EOL modules for ERX routers first and then for E120 and E320 routers.
ERX14xx models
ERX310 router
E120 router
E320 router
NOTE: Any future JunosE release number provided in the Actual or Predicted
Last JunosE Support field of Table 1 on page 3 is based on the current JunosE release schedule. If the release schedule changes in the future, Juniper Networks will update the associated Product Support Notification (PSN) Technical Bulletin for any affected EOL modules.
For more information about E Series routers and modules, refer to the following guides:
ERX module installation and maintenance—ERX Hardware Guide
E120 and E320 module installation and maintenance—E120 and E320 Hardware Guide
Managing E Series routers—JunosE System Basics Configuration Guide
Configuring E Series modules—JunosE Link Layer Configuration Guide
To obtain the most current list of EOL modules, see the End-of-Life Products page on the Juniper Networks Web site at http://www.juniper.net/support/eol.
Copyright © 2010, Juniper Networks, Inc.2
Table 1: End-of-Life Modules
Line Module LabelCombination Name
ERX ROUTER MODULES
CE1

Channelized OC3/STM1

cOCx/STMxF0cOC3/STM1 multimode
I/O Module Label
I/O
MULTIMODE
First JunosE Support
Actual or Predicted Last JunosE Support
Page
87.3.x1.1.0CE1 FULL I/OCE1CE1
915.0.x2.2.0cOC3 STM1 F0
intermediate reach
long reach

Channelized OC12/STM4

without APS/MSP redundancy
single-mode intermediate reach without APS/MSP redundancy
single-mode intermediate reach with APS/MSP redundancy
cOCx/STMxF0cOC3/STM1single-mode
I/O
SINGLE MODE
cOCx/STMxF0cOC3/STM1single-mode
I/O
LONG HAUL
cOCx/STMxF0cOC12/STM4multimode
I/O
MULTI MODE
cOCx/STMxF0cOC12/STM4
I/O
SINGLE MODE
cOCx/STMxF0cOC12/STM4
COC12 F0 APS
SINGLE MODE
7.0.2,
7.2.0
1115.0.x2.2.0cOC3 STM1 F0
1315.0.x2.2.0cOC3 STM1 F0
1515.0.x2.2.0cOC12 STM4 F0
1715.0.x2.2.0cOC12 STM4 F0
1915.0.x6.1.3,
single-mode long reach
Channelized T1
Channelized T3
cOCx/STMxF0cOC12/STM4
LONG HAUL
2115.0.x2.2.0cOC12 STM4
237.3.x1.1.0CT1 FULL I/OCT1CT1
3Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Table 1: End-of-Life Modules (continued)
Line Module LabelCombination Name
E3
I/O Module Label
First JunosE Support
Actual or Predicted Last JunosE Support
Page
247.0.x1.0.0CT3/T3 I/OCT3CT3 (3 ports)
2514.0.x3.2.0CT3/T3 12 I/OCT3/T3-F0CT3/T3 12 (12 ports)
267.1.x1.1.0E3 I/OE3 ATME3 ATM
277.0.x1.1.0E3 I/OE3 FRAMEE3 Frame (3 ports)

Fast Ethernet

Only line module is EOL.

Gigabit Ethernet (1–port)

(128 MB)
Only line module is EOL.
(128 MB)
Only line module is EOL.
(128 MB)
Only line module is EOL.
COCX-F3E3 Frame (12 ports)
FRAME I/O
2814.0.x4.0.2E3-12
297.0.x1.3.0FE-2 I/OFE-2FE-2 (2 ports)
305.2.x2.0.0FE-8 I/OGE/FEFE-8 (8 ports) (128 MB)
315.2.x2.0.0GE I/O SFPGE/FEGE 1000Base-LH
335.2.x2.0.0GE I/O SFPGE/FEGE 1000Base-SX
355.2.x2.0.0GE I/O SFPGE/FEGE 1000Base-ZX

HSSI

IPSec Service

IPSec Service

OC3/STM1

377.3.x3.1.0HSSI-3 I/OHSSI-3FHSSI
3814.0.x4.0.2No I/O moduleIPSEC
SERVICE
Copyright © 2010, Juniper Networks, Inc.4
Table 1: End-of-Life Modules (continued)
Line Module LabelCombination Name
I/O Module Label
First JunosE Support
Actual or Predicted Last JunosE Support
Page
multimode
single-mode

OC3/STM1 ATM

OC3/STM1 ATM multimode without APS/MSP redundancy (128 MB)
Only line module is EOL.
OC3/STM1 ATM single-mode intermediate reach without APS/MSP redundancy (128 MB)
Only line module is EOL.
OC3/STM1 ATM single-mode long reach without APS/MSP redundancy (128 MB)
OC3OC3 (dual-port)
OC3OC3 (dual-port)
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
394.1.x1.0.0OC3 I/O
MULTI MODE
404.1.x1.0.0OC3 I/O
SINGLE MODE
415.2.x2.0.0OC3-4 I/O
MULTI MODE
435.2.x2.0.0OC3-4 I/O
SINGLE MODE
455.2.x2.0.0OC3-4 I/O
LONG HAUL
Only line module is EOL.

OC12/STM4 ATM

OC12/STM4 ATM multimode without APS/MSP redundancy (128 MB)
Only line module is EOL.
OC12/STM4 ATM single-mode intermediate reach without APS/MSP redundancy (128 MB)
Only line module is EOL.
OCx/STMx ATM or OCx/STMx /DS3-ATM
OCx/STMx ATM or OCx/STMx /DS3-ATM
475.2.x2.0.0OC12 STM4 I/O
MULTI MODE
495.2.x2.0.0OC12 STM4 I/O
SINGLE MODE
5Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Table 1: End-of-Life Modules (continued)
Line Module LabelCombination Name
I/O Module Label
First JunosE Support
Actual or Predicted Last JunosE Support
Page
OC12/STM4 ATM single-mode long reach without APS/MSP redundancy (128 MB)
Only line module is EOL.

SRPs

memory)
OCx/STMx ATM or OCx/STMx /DS3-ATM
LONG HAUL
SRP I/OSRP-5G+SRP-5G+ (2-GB
SRP I/OSRP-10GSRP-10G(1-GB memory)
515.2.x2.0.0OC12 STM4 I/O
535.2.x1.0.0SRP I/OSRP-5GSRP-5G (512 MB)
548.0.x3.0.2SRP I/OSRP-5G+SRP-5G+ (512 MB)
5514.0.x4.1.3,
5.0.4,
5.1.2,
5.2.0
565.2.x1.1.0SRP I/OSRP-10GSRP-10G (512 MB)
578.0.x4.1.3,
5.0.4,
5.1.2,
5.2.0
587.1.x5.1.0SRP-SE I/OSRP-SE10GSRP-SE10G (512 MB)
SRP-40G PLUS (1 GB)
PLUS
T3
T3 ATM (4 ports) (128 MB)
Only line module is EOL.
ATM or OCx/STMx /DS3-ATM
Tunnel Service Module (TSM)
595.2.x3.4.1SRP I/OSRP-40GSRP-40G (512 MB)
607.1.x4.0.0SRP I/OSRP-40G
617.0.x1.1.0CT3/T3 I/OT3 ATMT3 ATM (3 ports)
625.2.x4.1.04xDS3 ATM I/OOCx/STMx
637.0.x1.1.0CT3/T3 I/OT3 FRAMET3 Frame (3 ports)
6414.0.x4.0.2CT3/T3 12 I/OCOCX-F3T3 Frame (12 ports)
Copyright © 2010, Juniper Networks, Inc.6
Table 1: End-of-Life Modules (continued)
Line Module LabelCombination Name
I/O Module Label
First JunosE Support
Actual or Predicted Last JunosE Support
Page
TSM
SERVICE

X.21/V.35

E120 and E320 ROUTER MODULES

Gigabit Ethernet IOA

10GE IOA
ES2-S1 10GE IOA
X.21/V.35 I/OX.21/V.35X.21/V.35
10GE IOA
658.0.x3.0.2No I/O moduleTUNNEL
667.3.x2.10.1,
3.3.2
6814.0.x7.0.1ES2-S1
7Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide

CE1 Module Combination

Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SRP module compatibility
CE1
CE1 FULL I/O
20
First supported: 1.1.0
Final supported: 7.3.x
40 W
Channelized E1
Non-ASIC
E1
HDLC framing
See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX1410 router
SRP-5G
SRP-5G+
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
1:N redundancy
RJ-48C,120 ohm
BNC, 75-ohm via a balun panel that connects to the I/O module
Use shielded cables to maintain EMC compliance.
The transmitted signal complies with ITUT G.703, Physical/electrical characteristics of hierarchical digital interfaces (November 2001) for cable lengths up to 450 m (492 yards).
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See ERX Module Guide, Appendix B, Module LEDs.
See Monitoring Interfaces in the Configuring Channelized T1 and Channelized E1 Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
8.0.x and earlier.
Copyright © 2010, Juniper Networks, Inc.8

cOC3/STM1 Multimode Module Combination

cOC3/STM1 Multimode Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC3 STM1 F0 I/O
MULTI MODE
4
First supported: 2.2.0
Final supported: 15.0.x
130 W
OC3/STM1 channelized to DS3, DS1, E1, and DS0
Supports either E1 or T1 operation, but not E1 and T1 operation simultaneously
EFA ASIC
OC3/STM1
DS3
T1, E1
DS0
HDLC framing
See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
9Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
Up to four SC full duplex connectors
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See ERX Module Guide, Appendix B, Module LEDs.
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 4, Configuring Channelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.10

cOC3/STM1 Single-Mode Intermediate Reach Module Combination

cOC3/STM1 Single-Mode Intermediate Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC3 STM1 F0 I/O
SINGLE MODE
4
First supported: 2.2.0
Final supported: 15.0.x
130 W
OC3/STM1 channelized to DS3, DS1, E1, and DS0
EFA ASIC
OC3/STM1
DS3, DS1
T1, E1
DS0
HDLC framing
See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
11Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
Up to four SC full duplex connectors
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See ERX Module Guide, Appendix B, Module LEDs.
See Monitoring Interfaces in JunosE Physical Layer ConfigurationGuide, Chapter 4, Configuring Channelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.12

cOC3/STM1 Single-Mode Long Reach Module Combination

cOC3/STM1 Single-Mode Long Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC3 STM1 F0 I/O
LONG HAUL
4
First supported: 2.2.0
Final supported: 15.0.x
130 W
OC3/STM1 channelized to DS3, DS1, E1, and DS0
EFA ASIC
OC3/STM1
DS3, DS1
T1, E1
DS0
HDLC framing
See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
13Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
Up to four SC full duplex connectors
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Fiber type: 9-micron core
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See ERX Module Guide, Appendix B, Module LEDs.
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 4, Configuring Channelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.14

cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination

cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC12 STM4 F0 I/O
MULTI MODE
1
First supported: 2.2.0
Final supported: 15.0.x
130 W
OC12/STM4 channelized to DS3, DS1, E1, and DS0
EFA ASIC
OC12/STM4
OC3/STM1
DS3, DS1
T1, E1
DS0
HDLC framing
See ERX Module Guide, Appendix A, Module ProtocolSupport for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
15Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See ERX Module Guide, Appendix B, Module LEDs.
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 4, Configuring Channelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.16

cOC12/STM4 Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination

cOC12/STM4Single-Mode IntermediateReach WithoutAPS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC12 STM4 F0 I/O
SINGLE MODE
1
First supported: 2.2.0
Final supported: Not applicable
130 W
OC12/STM4 channelized to DS3, DS1, E1, and DS0
EFA ASIC
OC12/STM4
OC3/STM1
DS3, DS1
T1, E1
DS0
HDLC framing
See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
17Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See ERX Module Guide, Appendix B, Module LEDs.
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 4, Configuring Channelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.18

cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination

cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
cOCx/STMx F0
COC12 F0 APS
SINGLE MODE
2
1 active, 1 redundant
First supported: 6.1.3 or later 6.1.x release, 7.0.2 or later 7.0.x release, 7.2.0 and higher-numbered release
Final supported: 15.0.x
130 W
OC12/STM4 channelized to DS3, DS1, E1, and DS0
EFA ASIC
OC12/STM4
OC3/STM1
DS3, DS1
T1, E1
DS0
HDLC framing
Software features
Model compatibility
SRP module compatibility
Module redundancy support
See ERX Module Guide, Appendix A, Module ProtocolSupport for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
19Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –7 dBm
Rated for 15 km (9.3 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See ERX Module Guide, Appendix B, Module LEDs.
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 4, Configuring Channelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.20

cOC12/STM4 Single-Mode Long Reach Module Combination

cOC12/STM4 Single-Mode Long Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC12 STM4
LONG HAUL
1 active, 1 redundant
First supported: 2.2.0
Final supported: 15.0.x
130 W
OC12/STM4 channelized to DS3, DS1, E1, and DS0
EFA ASIC
OC12/STM4
OC3/STM1
DS3, DS1
T1, E1
DS0
HDLC framing
See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
ERX7xx models
ERX14xx models
ERX310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G PLUS
SRP-SE10G
1:N redundancy
NOTE: Line module redundancy is not supported on the ERX310 router.
21Copyright © 2010, Juniper Networks, Inc.
E Series End-of-Life Module Guide
Cables and connectors
LEDs
Alarms, errors, and events
SC full duplex connector
Tx power:
min: –5.0 dBm
max: 0 dBm
Center wavelength: 1310 nm
Rx input power:
min: –34 dBm
max: –7 dBm
Fiber type: 9-micron core
Rated for 40 km (24.8 miles) of 9-micron core cable
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
See ERX Module Guide, Appendix B, Module LEDs.
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 4, Configuring Channelized OCx/STMx Interfaces.
Copyright © 2010, Juniper Networks, Inc.22
Loading...