This guide provides an overview and description of E Series modules that are end-of-life
(EOL) and can no longer be ordered for the following routers:
•
•
•
•
•
Depending on the EOL schedule of a module, new software releases might not support
the module.
Table 1 on page 3 lists EOL modules alphabetically. It lists EOL modules for ERX routers
first and then for E120 and E320 routers.
ERX7xx models
ERX14xx models
ERX310 router
E120 router
E320 router
NOTE: Any future JunosE release number provided in the Actual or Predicted
Last JunosE Support field of Table 1 on page 3 is based on the current JunosE
release schedule. If the release schedule changes in the future, Juniper
Networks will update the associated Product Support Notification (PSN)
Technical Bulletin for any affected EOL modules.
For more information about E Series routers and modules, refer to the following guides:
•
ERX module installation and maintenance—ERX Hardware Guide
•
E120 and E320 module installation and maintenance—E120 and E320 Hardware Guide
•
Managing E Series routers—JunosE System Basics Configuration Guide
•
Configuring E Series modules—JunosE Link Layer Configuration Guide
To obtain the most current list of EOL modules, see the End-of-Life Products page on
the Juniper Networks Web site at http://www.juniper.net/support/eol.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
1:N redundancy
•
RJ-48C,120 ohm
•
BNC, 75-ohm via a balun panel that connects to the I/O module
•
Use shielded cables to maintain EMC compliance.
•
The transmitted signal complies with ITUT G.703, Physical/electrical
characteristics of hierarchical digital interfaces (November 2001) for cable
lengths up to 450 m (492 yards).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring Channelized T1 and Channelized E1
Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
Supports either E1 or T1 operation, but not E1 and T1 operation simultaneously
•
EFA ASIC
•
OC3/STM1
•
DS3
•
T1, E1
•
DS0
•
HDLC framing
•
See ERX Module Guide, Appendix A, Module Protocol Support for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
Model compatibility
SRP module compatibility
Module redundancy support
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
cOC3/STM1 Single-Mode Long Reach Module Combination
cOC3/STM1 Single-Mode Long Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC3 STM1 F0 I/O
LONG HAUL
•
4
•
First supported: 2.2.0
•
Final supported: 15.0.x
•
130 W
•
OC3/STM1 channelized to DS3, DS1, E1, and DS0
•
EFA ASIC
•
OC3/STM1
•
DS3, DS1
•
T1, E1
•
DS0
•
HDLC framing
•
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination
cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC12 STM4 F0 I/O
MULTI MODE
•
1
•
First supported: 2.2.0
•
Final supported: 15.0.x
•
130 W
•
OC12/STM4 channelized to DS3, DS1, E1, and DS0
•
EFA ASIC
•
OC12/STM4
•
OC3/STM1
•
DS3, DS1
•
T1, E1
•
DS0
•
HDLC framing
•
See ERX Module Guide, Appendix A, Module ProtocolSupport for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
Model compatibility
SRP module compatibility
Module redundancy support
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination
cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module
Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
cOCx/STMx F0
COC12 F0 APS
SINGLE MODE
•
2
•
1 active, 1 redundant
•
First supported: 6.1.3 or later 6.1.x release, 7.0.2 or later 7.0.x release, 7.2.0 and
higher-numbered release
•
Final supported: 15.0.x
•
130 W
•
OC12/STM4 channelized to DS3, DS1, E1, and DS0
•
EFA ASIC
•
OC12/STM4
•
OC3/STM1
•
DS3, DS1
•
T1, E1
•
DS0
•
HDLC framing
Software features
Model compatibility
SRP module compatibility
Module redundancy support
•
See ERX Module Guide, Appendix A, Module ProtocolSupport for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
cOC12/STM4 Single-Mode Long Reach Module Combination
cOC12/STM4 Single-Mode Long Reach Module Combination
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
cOCx/STMx F0
cOC12 STM4
LONG HAUL
•
1 active, 1 redundant
•
First supported: 2.2.0
•
Final supported: 15.0.x
•
130 W
•
OC12/STM4 channelized to DS3, DS1, E1, and DS0
•
EFA ASIC
•
OC12/STM4
•
OC3/STM1
•
DS3, DS1
•
T1, E1
•
DS0
•
HDLC framing
•
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
Model compatibility
SRP module compatibility
Module redundancy support
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
1:N redundancy
•
RJ-48C 100–ohm connector
•
Use shielded cables to maintain EMC compliance.
•
The line interface unit supports multiple line buildouts.
•
Signal strength is software controlled.
•
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy Electrical Interfaces (1999) for cable lengths up to 201 m (660 feet).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring Channelized T1 and Channelized E1
Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
1:N redundancy
•
BNC 75-ohm connector
•
The line interface unit supports two line buildouts:
•
0–68.5 m (0–225 feet)
•
69–137 m (226–450 feet)
•
Signal strength is software controlled.
•
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy Electrical Interfaces (1999) for cable lengths up to 201 m (660 feet).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring Channelized T3 Interfaces chapter
of the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
See ERX Module Guide, Appendix A, Module ProtocolSupport for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
•
BT43 SMB connector
•
Cable that adapts to 75-ohm BNC is available.
•
The line interface unit supports two line buildouts:
•
0–68.5 m (0–225 feet)
•
69–137 m (226–450 feet)
•
Signal strength is software controlled.
•
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy - Electrical
Interfaces (1999) for cable lengths up to 201 m (660 feet).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 1,
Configuring Channelized T3 Interfaces.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
1:N redundancy
•
BNC 75-ohm connector
•
The transmitted signal complies with ITUT G.703, Physical/electrical
characteristics of hierarchical digital interfaces (November 2001) for cable
lengths from 0–137 m (0–450 feet).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring T3 and E3 Interfaces chapter of
the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
1:N redundancy
•
BNC 75-ohm connector
•
The transmitted signal complies with ITUT G.703, Physical/electrical
characteristics of hierarchical digital interfaces (November 2001) for cable
lengths from 0–137 m (0–450 feet).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring T3 and E3 Interfaces chapter of
the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
•
BT43 SMB connector
•
Cable that adapts to 75-ohm BNC is available.
•
The transmitted signal complies with ITUT G.703, Physical/electrical
characteristics of hierarchical digital interfaces (November 2001) for cable
lengths from 0–137 m (0–450 feet).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in JunosE PhysicalLayer Configuration Guide, Chapter 2,
Configuring T3 and E3 Interfaces.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
Not applicable
•
Accepts up to two RJ-45 connectors.
•
For 10-Mbps operation, use CAT 3, 4, or 5 UTP cable.
•
For 100-Mbps operation, use only CAT 5 UTP cable.
•
The transmitted signal complies with IEEE 802.3/802.3u for cable lengths up
to 100 m (328 feet).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Ethernet Interfaces in the Configuring Ethernet Interfaces chapter
of the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
FE-8 I/O
•
8
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Fast Ethernet
•
ASIC
•
IEEE 802.3 standards compliance
•
10/100Base-T
•
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
Not applicable
•
RJ-45 connectors
•
For 10-Mbps operation, use CAT 3, 4, or 5 UTP cable.
•
For 100-Mbps operation, use only CAT 5 UTP cable.
•
The transmitted signal complies with IEEE 802.3/802.3u for cable lengths up
to 100 m (328 feet).
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Ethernet Interfaces in the Configuring Ethernet Interfaces chapter
of the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
GE 1000Base-LH Module Combination (1 Port) (128 MB)
GE 1000Base-LH Module Combination (1 Port) (128 MB)
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
GE I/O SFP
•
1 active, 1 redundant
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Gigabit Ethernet
•
The GE SFP I/O module uses a range of small form-factor pluggable (SFP)
transceivers to support different modes and cable lengths.
•
The transceivers on this GE I/O module are 1000Base-LX/LH compliant.
•
ASIC
•
Ethernet (IEEE 802.3z)
•
1000Base-LH
•
See ERX Module Guide, Appendix A, Module ProtocolSupport for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
Rated for 10 km (6.2 miles) over 10-micron core cable
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Ethernet Interfaces in the Configuring Ethernet Interfaces chapter
of the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
GE 1000Base-SX Module Combination (1 Port) (128 MB)
GE 1000Base-SX Module Combination (1 Port) (128 MB)
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
GE I/O SFP
•
1 active, 1 redundant
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Gigabit Ethernet
•
The GE SFP I/O module uses a range of small form-factor pluggable (SFP)
transceivers to support different modes and cable lengths.
•
The transceivers on this GE I/O module are 1000Base-SX compliant.
•
ASIC
•
Ethernet (IEEE 802.3z)
•
1000Base-SX
•
See ERX Module Guide, Appendix A, Module ProtocolSupport for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
Rated for 275 m (300 yards) over 62.5-micron core cable
•
Rated for 550 m (601 yards) over 50-micron core cable
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Ethernet Interfaces in the Configuring Ethernet Interfaces chapter
of the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
GE 1000Base-ZX Module Combination (1 Port) (128 MB)
GE 1000Base-ZX Module Combination (1 Port) (128 MB)
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
GE/FE
GE I/O SFP
•
1 active, 1 redundant
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Gigabit Ethernet
•
The GE SFP I/O module uses a range of small form-factor pluggable (SFP)
transceivers to support different modes and cable lengths.
•
The transceivers on this GE I/O module are 1000Base-ZX compliant.
•
ASIC
•
Ethernet (IEEE 802.3z)
•
1000Base-ZX
•
See ERX Module Guide, Appendix A, Module ProtocolSupport for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
Rated for 70 km (43.4 miles) over 10-micron core cable
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Ethernet Interfaces in the Configuring Ethernet Interfaces chapter
of the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
Not applicable
•
Standard HSSI connector: 2-row, 50-pin, receptacle header with rails and
latch blocks
•
50 feet (15.24 m) maximum cable length
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more
information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring HSSIs chapter of the JunosE
Physical Layer Configuration Guide for Release 8.0.x and earlier.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
Multiple IPSec Service modules provide redundancy.
•
Not applicable
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Tunnel-Service Interfaces in JunosE Physical Layer
ConfigurationGuide, Chapter 6, Managing Tunnel-Serviceand IPSec-Service
Interfaces.
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC3-4 I/O
MULTI MODE
•
4
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Unchannelized, concatenated OC3/STM1 for ATM
•
ASIC
•
OC3/STM1
•
ATM:AAL5
•
See ERX Module Guide, Appendix A, Module Protocol Support for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9
dB or 50-micron core cable with an optical loss of 7 dB
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring SONET/SDH Interfaces in the Configuring Unchannelized OCx/STMx
Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC3-4 I/O
SINGLE MODE
•
4
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Unchannelized, concatenated OC3/STM1 for ATM
•
ASIC
•
OC3/STM1
•
ATM/AAL5
•
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
Rated for 15 km (9.3 miles) of 9-micron core cable
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring SONET/SDH Interfacesin the Configuring Unchannelized OCx/STMx
Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
OC3/STM1 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (128 MB)
OC3/STM1 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module
Combination (128 MB)
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC3-4 I/O
LONG HAUL
•
4
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Unchannelized, concatenated OC3/STM1 for ATM
•
ASIC
•
OC3/STM1
•
ATM/AAL5
•
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
Rated for 40 km (24.8 miles) of 9-micron core cable
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring SONET/SDH Interfacesin the Configuring Unchannelized OCx/STMx
Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
OC12/STM4 ATM Multimode Without APS/MSP Redundancy Module Combination (128 MB)
OC12/STM4 ATM Multimode Without APS/MSP Redundancy Module Combination
(128 MB)
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 I/O
MULTI MODE
•
1
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Unchannelized, concatenated OC12/STM4 for ATM
•
ASIC
•
OC12/STM4
•
ATM/AAL5
•
See ERX Module Guide, Appendix A, Module Protocol Support for information about
the layer 2 and layer 3 protocols and applications that this module combination
supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9
dB or 50-micron core cable with an optical loss of 7 dB
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring SONET/SDH Interfaces in the Configuring Unchannelized OCx/STMx
Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 I/O
SINGLE MODE
•
1
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Unchannelized, concatenated OC12/STM4 for ATM
•
ASIC
•
OC12/STM4
•
ATM/AAL5
•
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
Rated for 15 km (9.3 miles) of 9-micron core cable
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring SONET/SDH Interfacesin the Configuring Unchannelized OCx/STMx
Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
OC12/STM4 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (128 MB)
OC12/STM4 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module
Combination (128 MB)
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
OC12 STM4 I/O
LONG HAUL
•
1
•
First supported: 2.0.0
•
Final supported: 5.2.x
•
130 W
•
Unchannelized, concatenated OC12/STM4 for ATM
•
ASIC
•
OC12/STM4
•
ATM/AAL5
•
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
Rated for 40 km (24.8 miles) of 9-micron core cable
•
See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring SONET/SDH Interfacesin the Configuring Unchannelized OCx/STMx
Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
1:N redundancy
•
BNC 75-ohm connector
•
The line interface unit supports two line buildouts:
•
0–68.5 m (0–225 feet)
•
69–137 m (226–450 feet)
•
Signal strength is software controlled.
•
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy Electrical Interfaces (1999) for cable lengths up to 201 m (660 feet).
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring T3 and E3 Interfaces chapter of
the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
This module combination is no longer supported because the line module has reached end-of-life. However, the
I/O module is still supported.
Line module label
I/O module label
Number of I/O ports
Software release
Description
Type
Capability
Software features
Model compatibility
SRP module compatibility
OCx/STMx ATM or OCx/STMx /DS3-ATM
4xDS3 ATM I/O
•
4
•
First supported: 4.1.0
•
Final supported: 5.2.x
•
130 W
•
Unchannelized T3 for ATM
•
ASIC
•
ATM/AAL5
•
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
1:N redundancy
•
75-ohm connector
•
The line interface unit supports two line buildouts:
•
0–68.5 m (0–225 feet)
•
69–137 m (226–450 feet)
•
Signal strength is software controlled.
•
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy Electrical Interfaces (1999) for cable lengths up to 201 m (660 feet).
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring T3 and E3 Interfaces chapter of the
JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
SRP-5G
•
SRP-5G+
•
SRP-10G
•
1:N redundancy
•
BNC 75-ohm connector
•
The line interface unit supports two line buildouts:
•
0–68.5 m (0–225 feet)
•
69–137 m (226–450 feet)
•
Signal strength is software controlled.
•
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy Electrical Interfaces (1999) for cable lengths up to 201 m (660 feet).
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in the Configuring T3 and E3 Interfaceschapter of the
JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
1:N redundancy
•
NOTE: Line module redundancy is not supported on the ERX310 router.
•
BT43 SMB
•
Cable that adapts to 75-ohm BNC is available.
•
The line interface unit supports two line buildouts:
•
0–68.5 m (0–225 feet)
•
69–137 m (226–450 feet)
•
Signal strength is software controlled.
•
The transmitted signal complies with ANSI T1.102-1993 Digital Hierarchy Electrical Interfaces (1999) for cable lengths up to 201 m (660 feet).
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 2,
Configuring T3 and E3 Interfaces.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX14xx models
•
ERX310 router
SRP module compatibility
Module redundancy support
Cables and connectors
LEDs
Alarms, errors, and events
•
SRP-5G+
•
SRP-10G
•
SRP-40G
•
SRP-40G PLUS
•
SRP-SE10G
•
Multiple TSMs provide redundancy.
•
See the Managing Tunnel-Service and IPSec-Service chapter of the JunosE
Physical Layer Configuration Guide for Release 8.0.x and earlier.
•
Not applicable
•
See ERX Module Guide, Appendix B, Module LEDs.
•
See Monitoring Tunnel-Service Interfaces in the Managing Tunnel-Service and
IPSec-Service Interfaces chapter of the JunosE Physical Layer Configuration
Guide for Release 8.0.x and earlier.
See ERX Module Guide, Appendix A, Module Protocol Support for information
about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
ERX7xx models
•
ERX1410 router
•
SRP-5G
•
SRP-5G+
•
SRP-10G
Module redundancy support
Cables and connectors
Cable Lengths
Transmission Speed (Hz)
•
2400
•
4800
•
9600
•
19200
•
38400
•
56000
•
2048000
LEDs
•
Not applicable
•
200-pin proprietary socket on I/O module
•
DB15 X.21 or DB34 V.35 at remote end
•
Serial signals can travel a limited distance without significant degradation.
Slowerserial signals can travel farther without degradation than fasterserial
signals. See “Cable Lengths” row for the maximum cable lengths you can
use to prevent signal degradation at various transmission speeds.
See Monitoring Interfaces in the Configuring X.21/V.35 Interfaces chapter of
the JunosE Physical Layer Configuration Guide for Release 8.0.x and earlier.
Uses a range of 10-gigabit small form-factor pluggable (XFP) transceivers to support
different modes and cable lengths.
•
Ethernet (IEEE 802.3ae)
•
10Gb Base-SR/LR/ER/ZR
•
Port can operate in full duplex mode with an average data rate of 3.4 Gbps
•
See E120 and E320 Module Guide, Appendix A, Module Protocol Support for
information about the layer 2 and layer 3 protocols and applications that this module
combination supports.
•
E320 router
•
E120 router
•
ES2 4G LM
SRP module compatibility
Line module redundancy
compatibility
Port redundancy support
Cablesand connectors (multimode
[SR])
•
SRP-100
•
SRP-120
•
SRP-320
•
Can be paired with an ES2 4G LM.
•
Must be installed in the same redundancy group as an ES2 4G LM and ES2–S1
REDUND IOA combination.
•
Not applicable
•
One LC full duplex connector
•
Transmit power:
•
min: –7.3 dBm
•
max: –1.0 dBm
•
Receive input power:
•
min: –9.9 dBm
•
max: –1.0 dBm
•
See the following corresponding table (SR Fiber Optic Cabling) for cabling
requirements.
•
See E120 and E320 Hardware Guide, Chapter 5, Cabling the Router for more
information.
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United
States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All other
trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify,
transfer, or otherwise revise this publication without notice.
Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are
owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312,
6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785.
E Series™ Broadband Services Routers E Series End-of-Life Module Guide