This guide explains how to set up and use American Innovations’ software installed on the
Allegro CX Field PC
Topics in this chapter include those in the following list:
•Equipment List (page 1)
•Preparing the Allegro for Use (page 2)
•Overview of AI’s Allegro Software (page 13)
•Overview of the Allegro Hardware (page 10)
•System Tray Icons (page 18)
•Contacting Technical Services (page 20)
®
.
1
Equipment List
Your Allegro ships from American Innovations (AI) with the following items. Several
optional add-ons are available for purchase, such as GPS (global positioning system). For a
complete list contact AI Sales at 1-800-229-3404.
Items provided in the box with the Allegro include:
•Rechargeable Battery Pack and AC Charger
•Serial Communication cable (female/female 9-pin, null modem cable)
•Mini Stylus and Pen-Style Stylus
1
Page 8
AI Allegro CX User’s Guide
•Hand Strap and Shoulder Strap
•Screen Protector
•AI Allegro CD with copies of AI software, user guide, release notes, and upgrade
procedures
•Microsoft
•Juniper Systems CD with owner’s manual and quick start guide
Getting Started
CD with Windows Mobile Device Center and ActiveSync
Preparing the Allegro for Use
When you first receive the Allegro from AI, perform the following tasks to prepare the
device for service:
•Install the Battery Pack (see page 2)
•Set Display Properties for a Monochrome Display (see page 4)
•Set Regional Settings, Time Zone, and Date/Time (see page 5)
•Install Windows Mobile Device Center or ActiveSync (see page 6)
•Transfer Utility Files to PCS (see page 9)
Install the Battery Pack
Complete the following steps to install and charge the battery pack. Charge the battery
pack for at least six hours.
1
Push the sliding latches up on the sides of the Allegro to open the battery
compartment door (Figure 1-1).
Figure 1-1. Slide Latches
2Getting Started
Page 9
AI Allegro CX User’s Guide
2
Place the battery pack in the battery compartment with the small arrow pointing to
the right (Figure 1-2). Push the battery pack down and then slide it to the right to
secure it in place.
Figure 1-2. Install Battery Pack
3
Push the battery door closed until slide latches click into place. If slide latches are
not securely in place, the unit is no longer water tight.
4
Plug the battery charger into a wall outlet, then the Allegro (Figure 1-3). The
Battery Parameters
window (Figure 1-4) automatically displays after applying
power.
Set
Figure 1-3. Connect Battery Charger
Get ti n g S t ar te d3
Page 10
AI Allegro CX User’s Guide
5
Complete the following settings in the
(Figure 1-4):
Set Battery Parameters
window
•Set charge percentage to
(%)
.
•Set
Figure 1-4. Set Battery Parameters
Battery Capacity
to
10%
in the field
4000
and then tap Accept to close the window.
Enter new Battery Charge Level
Set Display Properties for a Monochrome Display
If the Allegro includes a monochrome display, complete the following steps to set display
properties:
1
Ta p
Start
>
Settings
>
Control Panel
>
Display
icon.
Figure 1-5. Display Properties
2
Tap t he
field and
3
Ta p OK and then the Close icon (X) to return to the Allegro desktop.
4Getting Started
Appearance
Desktop
in the
tab (Figure 1-5). Select
Item
field.
High Contrast White
in the
Scheme
Page 11
AI Allegro CX User’s Guide
Set Regional Settings, Time Zone, and Date/Time
Regional settings specify the style that date/time, numbers, and currency are displayed.
After selecting a display style, set up the Allegro with your preferred time zone, date, and
time.
Complete the following steps:
1
Ta p
Start
>
Settings
Regional Settings Properties
2
Set your preferred language
style for
Panel
Number, Currency, Time
window.
>
Control Panel
window (Figure 1-6).
Your Loc a le
>
Regional Settings
. Use the remaining tabs to set the display
, and
Date
. Click OK to return to the
to display the
Control
Figure 1-6. Regional Settings
3
Tap t he
Date/Time
icon in the
settings:
•Set up the
current date, time
Savings Time applies to your preferred time zone, tap
in effect
•Tap
to enable this option.
OK
to apply settings and close the window. Tap the Close icon (X) to
return to the Allegro desktop.
Control Panel
window and complete the following
, and your preferred
time zone
Daylight savings time
. If Daylight
Figure 1-7. Time Zone and Date/Time
Get ti n g S t ar te d5
Page 12
AI Allegro CX User’s Guide
Install Windows Mobile Device Center or ActiveSync
The Allegro communicates with a computer using either Windows Mobile Device Center
(for Windows 7 and Vista) or Microsoft ActiveSync (for Windows XP or 2000).
If your computer is not installed with Windows Mobile Device Center (WMDC) or
ActiveSync, complete the following steps to install the software. View your computer’s
Start Menu
Windows 7/Vista: Install Windows Mobile Device Center
If your computer is running Windows 7 or Windows Vista, complete the following steps:
1
2
to determine if the software is installed (
Insert the
with the Allegro. If you cannot locate the CD, please contact Technical Services at
pcstechservices@aiworldwide.com.
Plug the provided serial cable in the Allegro and your computer.
Getting Started
CD in the CD drive of your computer. The CD is included
Start
>
Program Files
or
Programs)
.
3
Download the
clicking the download link that appears in the pop-up window.
4
Select
Run this program from its current location
screen prompts to install the software.
5
Create a connection at anytime by connecting one end of the serial cable in
your computer and the other end in the Allegro. WMDC automatically opens
(Figure 1-8). Click
connection.
Windows Mobile Device Center Installer
and click OK. Follow on-
Connect without setting up your device
to your computer by
to create a
Figure 1-8. Windows Mobile Device Center
6Getting Started
Page 13
AI Allegro CX User’s Guide
Windows XP/2000: Install ActiveSync
If your computer is running Windows XP or Windows 2000, complete the following steps:
1
Insert the
with the Allegro. If you cannot locate the CD, please contact Technical Services at
pcstechservices@aiworldwide.com.
2
Follow on-screen prompts to install ActiveSync.
3
To establish a sync connection with the Allegro and your computer, follow these
steps:
a
b
Getting Started
CD in the CD drive of your computer. The CD is included
Connect the serial cable to your computer and the Allegro.
When
Synchronization Setup Wizard
to create a sync partnership. Clicking
displays, click
Cancel
allows you to create a
Cancel
connection instead (Figure 1-9).
when prompted
Guest
Figure 1-9. Synchronization Setup Wizard
A successful sync connection occurs when the following ActiveSync window
displays (Figure 1-10).
Get ti n g S t ar te d7
Page 14
AI Allegro CX User’s Guide
Figure 1-10. ActiveSync Connected
NOTE: If a successful sync connection
does not
occur and you also use a VPN (virtual
private network) software to establish a remote connection with a private network: (1)
Disable or disconnect the VPN software. (2) Recycle power to the Allegro and your
computer. (3) Click
Cancel
when
Synchronization Setup Wizard
displays. If a sync
connection has not been established, contact Technical Services at
pcstechservices@aiworldwide.com.
8Getting Started
Page 15
Transfer Utility Files to PCS
If you use Pipeline Compliance System (PCS) with the Allegro, complete the following
steps to transfer two utility files from the Allegro installation CD to the PCS CPDM
installation directory on your computer. The utility files are labeled
CeFileXer.exe
IMPORTANT: PCS typically installs in the CPDM installation folder on C: drive of your
computer (C:\CPDM). If you installed PCS in a different folder, locate the folder by
searching for either of the utility files. Click the Windows
wToCmd.exe
installation folder.
Complete the following steps:
1
on the Allegro installation CD.
or
CeFileXer.exe
Insert the Allegro installation CD in your computer’s CD drive.
in the
Search
AI Allegro CX User’s Guide
wToCmd.exe
Start
button and then type
field to locate the utility files and PCS CPDM
and
2
Open Windows Explorer and view the contents of the CD folder labeled
on the installation CD.
3
Drag the files
CPDM installation folder on your computer (Figure 1-11).
4
Click
Yes
the
Move File
wToCmd.exe
or
Move and Replace
message.
and
CeFileXer.exe
to update existing files when Windows displays
from the installation CD to the PCS
PCS Files
Figure 1-11. PCS CPDM Installation Folder
Get ti n g S t ar te d9
Page 16
AI Allegro CX User’s Guide
GPS Antenna
(optional add-on)
Function Keys
Blue Shift Key
Keyboard
Keyboard
Gold Shift Key
Circular Navigation Key
Touchscreen Display
Overview of the Allegro Hardware
The Allegro includes a connector panel, touchscreen display, keypad, and function keys
(Figure 1-12). Optional add-ons available for purchase include a GPS expansion pod with
GPS antenna and a Trimble GPS receiver. For a complete list of add-ons available for
purchase, contact AI Sales at 1-800-229-3404.
Figure 1-12. Allegro Field PC
10Getting Started
Page 17
Connector Panel
GPS Antenna
(optional add-on)
COM 2
Infrared Port
DVM Negative (–)
Black
DVM Positive (+)
Red
COM 1
AC or Vehicle
Power Jack
GPS Antenna Connector
Remote Trigger Connector
(3-pin connector)
Mini Stylus
The connector panel is located at the top of the Allegro (Figure 1-13). It supports
connections for items in the list below.
Figure 1-13. Allegro Connector Panel
AI Allegro CX User’s Guide
The connector panel supports the following connections:
•DVM positive and negative test leads.
•Remote trigger for data cane or wire counter (3-pin connector).
•Communication ports with the following characteristics:
•Infrared port for wireless communication with a printer or computer using
ActiveSync.
•USB port for connecting to an optional USB power dock.
•Two 9-pin serial communication ports labeled COM1 and COM2
•AC or optional vehicle power adapter
•GPS expansion pod (optional add-on)
•GPS antenna (optional add-on)
Get ti n g S t ar te d11
Page 18
AI Allegro CX User’s Guide
Chainer
Stick
Adapter
Switch
(top view)
Chainer/Stick Adapter Switch
A hardware switch inside the Allegro must be set before taking survey readings. Use the
procedure below to set the switch in
readings. If using a wire counter instead, set the switch in
Chainer
mode if using a data cane to take survey
Stick Adapter
mode.
To set the Allegro in either
1
If the Allegro is on, press the power button to turn
2
If a GPS antenna cable is connected to the Allegro, disconnect the cable.
3
Use a coin or flathead screwdriver to loosen two screws securing the card slot door
on the back of the Allegro. Turn screws counter-clockwise
the door.
Figure 1-14. Open Card Slot Door
Chainer
or
Stick Adapter
mode, follow these steps:
Off
the device.
¼ of a turn to release
4
Open the card slot door and set the switch in one of the following positions
(Figure 1-15). When you finish, close and fasten the door.
•
Chainer:
•
Stick Adapter:
Figure 1-15. Set Chainer/Stick Adapter Switch Position
if using a wire counter, select
if using a data cane, select
Chainer
.
Stick Adapter
.
12Getting Started
Page 19
Overview of AI’s Allegro Software
The Allegro ships from AI with the following AI Allegro software factory-installed. AI
Allegro software version 4.3.1 is compatible with all version 6 and 7 PCS software.
Digital Voltmeter (AiDvm)Close Interval (CeCi)
AI Allegro CX User’s Guide
Measures voltage, current,
and resistance levels.
DC Voltage Gradient (DCVG)Periodic Survey
Records indications of pipeline
coating defects.
Figure 1-16. AI Allegro Software Overview
Records potential readings
for close interval (CI) surveys.
Records voltage readings for
annual and periodic surveys.
Get ti n g S t ar te d13
Page 20
AI Allegro CX User’s Guide
Touchscreen Display
Use the provided stylus to tap the touchscreen and activate a software program or make a
selection. Several system icons are available for selection that allow you to navigate.
IMPORTANT: Avoid using sharp objects that may scratch or puncture the touchscreen
display.
The Allegro includes a high-contrast, pressure-sensitive display with an adjustable
backlight and heater for cold weather operation. When working in harsh conditions, such
as a rainstorm or in high brush, pressing the
touchscreen on or off.
A display heater is included with the Allegro monochrome display to ensure effective
operation throughout different temperature ranges. The heater automatically turns on at
20 °F and turns off when the temperature is above 20 °F. Allegro color units do not require
a heater because the unit operates effectively in all temperatures. The monochrome
version of the Allegro displays best when the device is set up with the
theme. See
Set Display Properties for a Monochrome Display
BLUE
shift and TS buttons toggles the
High Contrast
on page 4 for instructions.
Recalibrate the Touchscreen Display
If the touchscreen does not respond accurately to stylus taps, recalibrate the touchscreen
manually using the following steps:
1
Ta p
Start
>
Settings
2
Ta p
Recalibrate
the touchscreen.
Figure 1-17. Recalibrate Touchscreen
3
When the process completes, tap OK to close the window and then tap the
icon
(X) to return to the Allegro desktop.
>
Control Panel
(Figure 1-17) and then follow on-screen prompts to recalibrate
>
Stylus
>
Calibration
tab.
Close
14Getting Started
Page 21
Keypad and Shortcut Keys
F1–F5 Function Keys
Tab Key
Space Bar
Orange Key
Enter Key
Blue Key
Circular Key
The Allegro keypad is similar to a computer keyboard (Figure 1-18). The keypad provides
the following functionality:
•Alphanumeric and symbol keys for data entry.
•Tab, Enter, Spacebar, and Circular keys for moving the cursor.
•F1 through F5 keys perform softkey operations in certain software programs. These
keys perform special functions when used in conjunction with either the Blue or
Gold key.
AI Allegro CX User’s Guide
Figure 1-18. Allegro Keypad
The table on the next page (Table 1-1) provides a list of global shortcut keys. Use the
Allegro keypad to run any of the identified commands.
Get ti n g S t ar te d15
Page 22
AI Allegro CX User’s Guide
Table 1-1. Global Shortcut Keys
CommandShortcut KeysDescription
Toggle Caps<
Display Backlight<
Brighten/Dim Screen
Display
Move between fields<
Close Window<
Enable/Disable
Touchscreen
Blue><CapLk
Gold><F3
<
Gold><F4
<
Gold><F5
>Toggles caps lock on and off
>Toggles backlight on/off.
>
>
Press <Gold><F4> to dim
screen display.
Press <Gold><F5>to brighten
screen display.
TAB
>Moves cursor between fields.
Left tab arrow moves cursor
forward one field; right tab
arrow moves cursor backward
one field.
Esc
>Close an open window.
<
Blue><TS
>Disable or enable the
touchscreen.
Tas k Ma nag e r<
Start
>Displays the Task Manager.
Table 1-2. Button and Button Sequence Functionality
Button or Button SequenceDescription
Alt button + tap touchscreenDesktop shortcut menu (similar to right-
mouse click on PC)
Gold key + F5Display Contrast Darker (monochrome
display only)
Gold key + F4Display Contrast Lighten (monochrome
display only)
Blue key + TSEnable / Disable touchscreen
16Getting Started
Page 23
AI Allegro CX User’s Guide
Table 1-2. Button and Button Sequence Functionality
Button or Button SequenceDescription
Blue key + EndEnd
Gold key + Function keyFunction keys F11 and F12
Blue key + Function keyFunction key F6 through F10
Blue key + HomeHome
Blue key + PgDnPage Down
Blue key + PgUpPage Up
Gold key + Circular key up,
Pan display in direction of arrow
down, right, or left arrow
Warm Reset/Soft Reboot: Press
Reset Allegro
and hold On/Off key for about 8
seconds. Release the key when
the restart process begins.
Press Tab arrow to move cursor
Tab f or ward o r b ac kw ar d
between fields.
Press Task Manager (Start) key to
Task M an ag er
view all running programs.
Gold key + INS Toggle auto-panning on/off
Blue key + StartView Start Menu
Get ti n g S t ar te d17
Page 24
AI Allegro CX User’s Guide
System Tray Icons
The system tray appears in the bottom right area of the Allegro desktop. See the next table
for a description of the various icons that display in the system tray.
Table 1-3. System Tray Icons
IconDescription
Remaining Battery Charge Status:
percentage of charge remaining in battery.
External Power Input:
source is connected and not drawing power from
internal battery pack.
Charging Indicator:
rechargeable batteries are being recharged.
Data Storage Idle: o
idle and not being read from or written to.
Data Storage Active:
read from or written to the solid state disk.
PC Card:
PC Card Activity:
accessing PC card. Do not remove card when this icon
is visible in system tray.
indicates a PC card is installed in the Allegro.
indicates external power
appears in system tray when
utlined when solid state disk is
darkens when data is being
indicates software program is
shows
18Getting Started
Caps Lock On:
option is activated. Press Blue shift and Shift/CapLk
keys to activate option. Press again to deactivate
option.
Touchscreen Disabled:
disabled. Press Blue shift and TS keys to enable or
disable touchscreen.
PC Connection:
connection between the Allegro and desktop or laptop
computer.
appears when the all capital letters
appears when touchscreen is
appears when there is an active
Page 25
Table 1-3. System Tray Icons (continued)
IconDescription
AI Allegro CX User’s Guide
Heater
(monochrome screen only): appears when
touchscreen heater turns on.
Bluetooth Connection:
appears when Bluetooth is
being actively used on the Allegro.
Get ti n g S t ar te d19
Page 26
AI Allegro CX User’s Guide
Contacting Technical Services
If you need assistance with the AI software or Allegro, or have a comment or suggestion
about this manual, contact Technical Services in any of the following ways:
Ai-DVM measures voltage, current, resistance, and diode capacitance as a fully functional
digital voltmeter (DVM) and as an integrated DVM to complement the following AI
software: CeCi (close interval), DCVG (direct current voltage gradient), and Periodic Survey
(annual/periodic survey).
You can view measurements either in the main window of AI-DVM or as a waveform graph.
Optional settings are available for measuring current interrupter on/off potentials and
operating in
Information in this chapter explains how to set up and use AI’s digital voltmeter, AI-DVM.
Topics include:
•Safety Precautions (page 23)
•Quick Start (page 24)
•DVM Graph Overview (page 27)
GPS Sync
mode when using GPS-synchronized current interrupters.
2
•Data Logger Overview (page 28)
•Shortcut Keys (page 29)
Safety Precautions
Observe the following safety precautions when using AI-DVM:
•Follow safety procedures for the equipment being tested. Inspect test leads for
damaged insulation or exposed metal. Check test lead continuity. Damaged leads
should be replaced.
•To avoid electrical shock and damage to the Allegro, do not use the Allegro when
working with voltages greater than that supported by the DAQ (data acquisition)
card or measuring current, except across a shunt.
•To avoid electrical shock and damage to the Allegro, remove test leads before
replacing the Allegro battery or connecting to a desktop or laptop computer. Set
up the Allegro with the correct test function and voltage range.
23
Page 30
AI Allegro CX User’s Guide
DVM
(–)
(+)
Quick Start
This section provides quick start procedures for setting up and using AI-DVM. As a user
you will perform the following actions:
•Connect test leads to the Allegro (page 24)
•Set test function, voltage range, and sample rate (page 24)
•Set properties to measure on/off potentials (page 25)
•Set GPS properties (page 25)
•Set properties to measure current across an external shunt (page 25)
•Set data logger properties (page 26)
Connect test leads to the Allegro
1
Plug test leads in the red positive (+) and black negative (–) jacks on the Allegro
connector panel; positive to positive, negative to negative (Figure 2-1).
2
Click the
window (Figure 2-1).
Figure 2-1. AI-DVM Main Window
AI-DVM
icon on the Allegro desktop to display the main AI-DVM
Set test function, voltage range, and sample rate
1
Choose a test function by tapping
2
Set the voltage range either manually by tapping the up or down arrow buttons or,
tapping
Auto
to use autoranging instead.
Vdc, Vac, Amp, Ohm
, or
Diode
.
3
Ta p
24Digital Voltmeter (AI-DVM)
4
Options
range
field and select a minimum voltage range.
Tap the drop-down arrow in the
(European Standard)
return to the main DVM window.
. If using autoranging, tap the drop-down arrow in the
Sample rate
or
60 Hz (US Standard)
field and select either
. Click Ok to save settings and
Minimum
50 Hz
Page 31
Set properties to measure on/off potentials
1
Verify
Vdc
is selected in the main DVM window and then tap
2
3
Tap t he
Ta p
Select
On/Off
Enable On/Off mode
HiLo
tab.
when using a non-GPS current interrupter(s) in an interrupted survey. If
and then select
HiLo
or
Gps-Sync
using a GPS synchronized current interrupter(s), select
4
Set up remaining fields with the same settings as those used by the current
interrupter(s).
5
Ta p Ok to save settings and return to the main DVM window.
Set GPS properties
1
Ta p
Options
in the main DVM window and then tap the
AI Allegro CX User’s Guide
Options
in the
Gps-Sync
GPS
tab.
.
Method
instead.
field.
2
If using the Allegro GPS internal module (optional add-on), verify
COM3 (internal)
The option
and
Baudrate
is
9600
Read PPS from Internal GPS
.
is unavailable for selection when using
Comm Port
the Allegro internal GPS module. AI-DVM automatically uses the PPS timing signal
received by the internal GPS module.
3
If using dual GPS (optional add-on), follow these steps to set up AI-DVM:
a
Set communication parameters (
Comm Port
and
Baudrate
) for a second GPS
receiver connected in COM 1 of the Allegro.
b
If you want to use the PPS timing signal received by the Allegro internal
module instead of the second GPS receiver, tap
GPS
.
4
Ta p Ok to save changes and return to the main DVM window.
Read PPS from Internal
Set properties to measure current across an external shunt
1
Ta p
Amp
in the main DVM window.
is
2
Set the voltage range either manually by tapping the up or down arrow buttons or,
tapping
3
Ta p
Options
Auto
to use autoranging instead.
>
Amps Mode
tab.
Digital Voltmeter (AI-DVM)25
Page 32
AI Allegro CX User’s Guide
4
Complete one of the following steps:
a
b
5
Ta p Ok to save changes and return to the main DVM window.
Set data logger properties
1
Ta p
2
Ta p
3
Set a time interval by tapping the drop-down arrow in the first
field and selecting a value (1-50). Tap the drop-down arrow in the second
interval
Tap
as R value
and enter a shunt resistance value in the
Resistance
-or-
If you want AI-DVM to automatically calculate shunt resistance, tap
mV values
Options
Enable logging
and enter a shunt size in the mV and
in the main DVM window and then the
.
Amps
fields.
Data Logger
tab.
Update interval
field and select a measurement of time (seconds, minutes, or hours).
field.
as Amp/
Update
IMPORTANT: When recording an hour or more of data, use the external AC power
adapter to prevent draining the Allegro battery. The automatic power-down
feature of the Allegro is disabled during data logging.
4
Ta p
Browse
a
Type a name for the file in the
b
Tap the drop-down arrow in the
c
Tap OK to save settings and close the
5
Ta p
Append
end of the file.
6
Ta p
Timestamp
7
Ta p OK to save settings and start a data logging session.
in the AI-DVM title bar. To stop the data logging session, tap
Logger
to display the
Save As
window and complete the following steps:
Name
field
Type
field and choose a file format.
Save As
window.
to include all readings in the file with the most recent reading at the
to include a time stamp with each reading.
DVM - Logging
tab >
Enable logging
Options
.
>
displays
Data
8
Ta p Ok to save changes and return to the main DVM window.
26Digital Voltmeter (AI-DVM)
Page 33
DVM Graph Overview
Shaded area represents on cycle;
non-shaded area represents off cycle.
Status line with current reading,
voltage range, and number of GPS
satellites in view.
Vertical dotted line indicates
recorded reading.
Horizontal dotted line indicates
zero (0) volts.
Sets upper voltage range.
Hold: Tap to stop or start scrolling data.
Save: Tap to display Data Remarks window
and save graph. Use Data Remarks to add
notes in a graph. Graph saves as a text file
and includes any added notes.
DVM: Tap to close graph and return to
DVM window.
Up/Down Arrows: Tap to set the voltage
range (20mV, 200mV, 2V, 25V, or 150 or 250V).
Tap in the white space area to view
real-time settings.
Black triangles indicate start of the
on cycle.
Sets lower voltage range.
Sets graph X-axis in seconds. Maximum
is 60 seconds.
1
AI-DVM displays the on/off interruption cycle in real-time as a waveform graph in addition
to the digital display in the main DVM window.
AI Allegro CX User’s Guide
When using AI-DVM during an on/off survey, tap
interruption cycle (Figure 2-2).
1
2
3
4
5
6
7
1
2
3
4
5
6
Graph
to view a waveform graph of the
8
7
8
9
10
8
9
10
Figure 2-2. DVM Graph
The graph includes a status line below the reading. The status line identifies the voltage
range, test function, and on/off method. If setup includes
also identifies the number of satellites in view.
For example, a status line of
•
25VDC
•
DGPS
: differential GPS is available
(5)
•
•
•
: number of satellites in view
P
: PPS time signal has been received
Z
: ZDA message has been received
25VDC DGPS (5) PZ
: voltage range and test function
GPS Sync
mode, the status line
indicates the following information:
Digital Voltmeter (AI-DVM)27
Page 34
AI Allegro CX User’s Guide
Other indicators that may appear in the status line include those in the following list:
•
GPS (n)
•
HiLo
•
GPS (n HiLo)
signal is unavailable. The lowercase n represents the number of satellites in view.
: indicates GPS and the number of satellites in view
: indicates high/low readings
: indicates GPS mode is selected but HiLo is used because the GPS
Data Logger Overview
Unless specified differently during setup, data logger files save in the
default. To access the folder, double-tap
The data logger file includes the following information (Figure 2-3):
•log file date and time stamp
•reading mode (on/off or single reading)
•readings with date and time stamp
•update interval and voltage range
If AI-DVM is setup in
Readings include a lower case
GPS Sync
My Computer
mode, GPS status is included in the log file.
g
next to the time stamp to indicate GPS time.
>
C_Drive
>
DvmData
BTS
>
DvmData
folder by
.
Figure 2-3. Data Logger File
To set up the data logger for use, refer to the
Set data logger properties
28Digital Voltmeter (AI-DVM)
Quick Start
.
topic on page 26 entitled
Page 35
Shortcut Keys
Shortcut keys are an alternate method for using certain commands in AI-DVM instead of
menu commands. Use the Allegro keypad to run any of the commands identified in the
following table (Table 2-1).
Table 2-1. AI-DVM Shortcut Keys
CommandShortcut KeysDescription
AiDVM Graph<
G
> or <
ALT><G
AI Allegro CX User’s Guide
>Displays AiDvm graph.
Copy / Paste<
Option Window<
Vol tage Range<
VDC Test Function<
VAC Test Function<
Amp Test Function<
Ohm Test Function<
Diode Test Function<
CTRL><C
N
> or <
ALT><N
CTRL><Up
<
CTRL><Down
<
Alt><U
D
A
M
O
D
> or <
> or <
> or <
> or <
> or <
> or <U>
ALT><D
ALT><A
ALT><M
ALT><I
ALT><D
>Copies a reading from the digital
voltmeter to paste into an PTab
spreadsheet file.
>Displays the Options window.
>
>
Adjust the voltage range or select
auto ranging. To increase, select
<CTRL><Up>; to decrease
<CTRL><Down>; and to auto
range select <ALT><U>.
>Selects the Vdc test function.
>Selects the Vac test function.
>Selects the Amp test function.
>Selects the Ohm test function.
>Selects the Diode test function.
Enable/Disable
Autoranging
Move Cursor to
Sample Rate Field
<
A
>Press A to move cursor to the
Auto-range enable field and either
enable or disable the option.
<
S
>Press S to move cursor to the
Sample rate field.
Digital Voltmeter (AI-DVM)29
Page 36
AI Allegro CX User’s Guide
Table 2-1. AI-DVM Shortcut Keys
CommandShortcut KeysDescription
Navigate DVM
Options Window
Open Graph Remarks
Window and Add
Data
Tab
>
<
<
Up/Down Arrows
<
Enter
>
Ok
> / <
> <
Cancel
Save
>
>
<
<
Tab
<
Enter
The following are available for use
in all tabs of DVM Options:
• Press <Tab> to move cursor
from one field to another.
• Press <Up/Down Arrows> to
>
move cursor in a drop-down
list. Press <Enter> to accept a
>
selection in a drop-down list.
• Move cursor to <Ok> and then
press <Enter> to apply
changes. Move cursor to
<Cancel> and then press
<Enter> to cancel changes.
• Press <Tab> to move cursor to
<Save> button and then press
<Enter> to open graph remarks
window.
• Press <Enter> in graph remarks
window to add a new line.
• To save remark, press <Tab> to
move cursor to <Ok> button
and then press <Enter>.
• To cancel remark, press <Tab>
to move cursor to <Cancel>
button and then press <Enter>.
30Digital Voltmeter (AI-DVM)
Page 37
Notes
AI Allegro CX User’s Guide
Digital Voltmeter (AI-DVM)31
Page 38
AI Allegro CX User’s Guide
32Digital Voltmeter (AI-DVM)
Page 39
Close Interval Survey (CeCi)
CeCi records pipeline potential readings for close interval (CI) surveys. The software
collects survey readings from a data cane or wire counter connected to the Allegro. CeCi
measures voltage using the digital voltmeter card inside the Allegro.
This chapter explains how to set up and use AI’s close interval software, CeCi. Topics
include:
•Quick Start (page 34)
•Set Survey File Options (page 39)
•Add Remarks and Test Point Information (page 41)
•View Survey Records and Show Bearing to Site (page 42)
•Export a Survey File (page 42)
3
•Transfer a Survey File to PCS (page 43)
•Shortcut Keys (page 45)
33
Page 40
AI Allegro CX User’s Guide
Trailing Wire
Fixed IncrementFlagged
Hip
Pack
Trailing Wire
Hip
Pack
Quick Start
Procedures in this section explain how to set up CeCi to record pipeline potential readings
for a close interval survey. As a user you will perform the following actions:
•Connect test leads to the Allegro (page 34)
•Set survey properties (page 35)
•Set survey type and mode (page 35)
•Set on/off survey type (page 37)
•Set GPS properties (page 38)
•Save survey file (page 38)
•Record inspection readings (page 38)
Connect test leads to the Allegro
CeCi software records potential readings using the Allegro digital voltmeter and either a
data cane or wire counter connected to the red and black jacks on the Allegro connector
panel.
To get started, complete the following steps:
1
Plug test leads in the red positive (+) and black negative (–) jacks on the Allegro
connector panel; positive to positive, negative to negative (Figure 3-1).
2
Click the
(Figure 3-1).
CeCi
icon on the Allegro desktop to display the main CeCi window
Figure 3-1. CeCi Main Window
34Close Interval Survey (CeCi)
Page 41
Set survey properties
1
Ta p
File
>
Properties
2
Provide information in the following fields of the
to display the
Survey
tab.
AI Allegro CX User’s Guide
Survey
tab:
Segment
•
you plan to transfer the survey file to PCS,
Code
folder labeled
•
Pipe:
survey file to PCS,
Code
: Enter the name of the ROW (right-of-way) in this required field. If
Segment
name must match
in PCS. If these fields do not match, PCS creates a new ROW Code and
Unknown
in the PCS hierarchy.
Enter a pipeline code in this optional f ield. If you plan to transfer the
Pipe
is equivalent to
Pipeline Code
in PCS. If the
entered earlier includes multiple, parallel pipelines with different pipeline
codes, enter the appropriate pipeline code. If pipeline codes have not been
created in PCS, leave this field empty.
Tech:
•
the survey file to PCS, the surveyor’s name populates the
Enter the surveyor’s name in this optional field. If you plan to transfer
Surveyor
field in the
Indirect Survey Manager (ISM) module.
Run:
•
Enter a unique survey name in this optional field. If transferring the
survey file to PCS, data in this field creates a new CI survey folder in ISM.
Examples of a unique survey name are: station number, milepost number, date,
or a combination of date and station or milepost number.
•
Date:
Enter a date or use the one automatically entered by CeCi.
ROW
ROW
Set survey type and mode
1
Tap t he
either
Once you begin the survey,
2
Tap t he
Flagged
3
Depending on the survey mode selected earlier, continue with the next procedure
or
Type
tab. Click the drop-down arrow in the
AC Survey
or
DC Survey
Survey Type
Modes
tab. Click the drop-down arrow in the
or
Fixed increment
Set fixed increment mode properties
Survey Type
field and select
.
cannot be changed.
Mode
field and select either
.
(page 36).
Close Interval Survey (CeCi)35
Page 42
AI Allegro CX User’s Guide
Set flagged mode properties
1
If using a metric data cane to trigger reads, tap
meters.
2
Enter the distance between flags or station markers in the
3
Tap the drop-down arrow in the
Descending
4
If you want to take timed readings using a data cane, tap
Readings
field.
Metric
to record readings in
Flag distance
Direction
field and select
Ascending
to indicate how station numbers increment in the survey file.
Enable Timed
and then enter the number of reads per minute in the
Readings/minute
field.
or
NOTE: Double-click detection must also be enabled in the
(
View
>
with an
Options
F
flag; triple-clicking will pause or resume timed readings. Pressing F5 or
>
Misc
tab). Double-clicking the data cane marks a survey record
Misc
tab of
Options
<Ctrl>+<P> on the Allegro keypad will also pause or resume timed readings.
5
If you want to monitor the number of reads per flag, tap
per flag
and then click the drop-down arrow in the
Monitor record count
Warn at above average
and select a percentage value. The Allegro beeps 3 times as a warning when the
number of reads for the current flag session is more than the average percentage
of reads taken for previous flag sessions.
6
Continue with
Set on/off survey type
(page 37).
Set fixed increment mode properties
1
If using a metric wire counter (chainer) to trigger reads, tap
readings in meters.
2
Enter the distance between reads in the
Increment
increments of 2.5 feet or 1 meter for metric mode.
field. The distance should be in
Metric
to record
field
3
Tap the drop-down arrow in the
Descending
4
Ta p
Use wire counter
(chainer).
36Close Interval Survey (CeCi)
Direction
field and select
Ascending
or
to indicate how station numbers increment in the survey file.
if survey readings will be taken using a wire counter
Page 43
Set on/off survey type
1
Tap t he
2
If you are taking an uninterrupted survey, tap the drop-down arrow in the
Type
native, static
3
If you are taking an interrupted survey using non-GPS synchronized interrupters,
complete the following steps:
a
b
c
On/Off
field and select
tab.
, or
depolarized
On (single reading
Tap the drop-down arrow in the
High/Low
.
Enter the same on/off times as set up for the current interrupter in the
time
and
OFF time
Enter an on delay time in the
Delay
field.
fields.
survey.
On Delay
AI Allegro CX User’s Guide
). An interrupted survey includes an on,
Survey Type
field and select
field and an
On/Off
off
delay time in the
Survey
ON
Off
On Delay
recorded.
is the time after the
Off Delay
is the time after the
off-to-on
transition when a reading is not
on-to-off
transition when a reading is
not recorded. If a reading is recorded during these transition times, the last
available reading before the transition is recorded.
4
If you are taking an interrupted survey using GPS synchronized current
interrupters, complete the following steps:
a
Tap the drop-down arrow in the
or
Sync
On/Off GPS Sync
On/off GPS Real-time
works best for short cycle surveys when the on and
interval is 1 second or less.
surveys when either the
on
Survey Type
field and select
.
On/Off GPS Real-time
or
off
cycle is greater than 1 second. For suggested
works best for long cycle
on/off settings, see Appendix A (page 75).
b
Enter the same on/off times as set up for the current interrupter in the fields
labeled
c
For an
an off delay time in the
ON time, OFF time
On/Off GPS Sync
Off Delay
, and
Cycle begins with
.
survey, enter a setup time in the
field.
On/Off GPS
On Setup
off
field and
On Setup
recorded.
not recorded. If a reading is recorded during these transition times. the last
available reading before the transition is recorded.
is the time before the
Off Delay
it the time after the
off-to-on
transition when a reading is not
on-to off
transition when a reading is
Close Interval Survey (CeCi)37
Page 44
AI Allegro CX User’s Guide
d
Set GPS properties
1
If you are taking an
GPS
For an
field, an
Setup Time
•
On/off GPS Real-time
off
delay time in the
field.
On Delay
is the time after the
survey, enter an on delay time in the
Off Delay
field, and a setup time in the
off-to-on
transition when a reading is not
recorded.
•
Off Delay
is the time after the
on-to-off
transition when a reading is not
recorded.
•
GPS-RT Setup Time
is the time before the transition when a reading is
not recorded.
If a reading is recorded during these transition times, the last available
reading before the transition is recorded.
On/Off GPS Sync
or
On/off GPS Real-time
survey, tap the
tab to set up GPS properties.
On Delay
GPS-RT
2
Ta p
Record GPS Location
drop-down arrow in the
to include coordinates with survey readings. Tap the
Record GPS Location
field and select an interval option
that identifies how often coordinates are included with readings.
3
Ta p
Record time of reading
4
If you are using a second GPS receiver (dual GPS), complete the following steps:
a
Tap the drop-down arrow in the
to include a GPS time stamp with readings.
Comm port
field and select the COM port
the GPS receiver is connected to.
b
Tap the drop-down arrow in the
Baudrate
field and select a baud rate
supported by the GPS receiver.
c
If you want the Allegro to synchronize with current interrupters using the
satellite PPS signal (pulse-per-signal), tap
5
Ta p Ok to save changes and return to the survey file.
Read PPS from Internal GPS
.
Save survey file
Tap t he
new survey file that has not previously been saved. Enter a name for the new survey file in
the
Save
icon or tap
Name
field and then tap OK.
File
>
Save
. The
Save As
window displays when working with a
Record inspection readings
If using a data cane, press
record readings in the survey file. If using a wire counter (chainer), each pulse from the
wire counter automatically records a reading in the survey file.
38Close Interval Survey (CeCi)
Enter
on the Allegro keypad or single-click the data cane to
Page 45
Set Survey File Options
AI Allegro CX User’s Guide
To set optional features in CeCi, tap
in the following list:
•Set audio and double-click properties (page 39)
•Set autosave and skip mode properties (page 39)
•Set GPS properties (page 40)
•Set color properties (page 40)
•Set graph properties (page 40)
View
>
Options
Set audio and double-click properties
1
Tap the Misc tab and select
beep each time a reading is taken.
2
If you want the Allegro to beep when the voltage is more positive than the warning
value you specify, tap
enter a warning value in the
Beep on every Reading
Beep for voltages less negative than this value
Voltage level
field.
. Topics in this section include those
if you want the Allegro to
, and
3
Ta p
Beep when overwrite existing data
survey reading is overwritten.
4
If you want to double-click the data cane to mark a record with a flag in CeCi, tap
Enable double-click detection
5
Ta p Ok to save changes and return to the survey file.
.
if you want the Allegro to beep when a
Set autosave and skip mode properties
1
Tap t he
2
Enter a time interval in the
save a survey file at regular time intervals.
3
Ta p
for the current record when skipping to another record during
4
Ta p Ok to save changes and return to the survey file.
File
tab and select
Retain Skipped records in Skip mode
Enable Autosave
Interval (minutes)
.
if you want CeCi to keep the reading
field to have CeCi automatically
Skip
mode.
Close Interval Survey (CeCi)39
Page 46
AI Allegro CX User’s Guide
Set GPS properties
1
Tap t he
2
If you want CeCi to remove existing GPS coordinates when updated coordinates
are unavailable after a specified amount of time, tap
and enter the number of seconds in the
When GPS coordinates are older than 30 seconds, CeCi displays the time since the
last GPS update. When GPS coordinates are older than 15 seconds, CeCi inserts an
asterisk (*) after the coordinates.
3
Tap the drop-down arrow in
Decimal minutes
4
Ta p Ok to save changes and return to the survey file.
Set color properties
1
Tap t he
GPS
tab.
Colors
GPS display Format
or
Decimal degrees
tab and select
seconds without updates
.
Enable color
Clear GPS location after
and select either
.
field.
Degrees and
2
Select an option in the list and then a color in the color grid. Repeat this step for
each item in the list you want to assign a color.
For example, to have readings display in red text in the survey file when readings
do not meet criteria, select
3
Ta p Ok to save changes and return to the survey file.
Set graph properties
1
Tap t he
2
Set upper voltage by entering a value in the
down arrows.
3
Set lower voltage by entering a value in the
down arrows.
4
Indicate how much data to display by entering a value (in feet) in the
or tapping the up/down arrows.
5
Ta p OK to close the window and return to the survey file.
Graph
tab and select
Invalid Value
Show Graph
and the color
.
Upper value
Lower value
red
in the color grid.
field or tapping the up/
field or tapping the up/
Width
field
6
Tap t he sa v e i co n.
Double-tapping inside the graph displays the
Options
7
Ta p Ok to save changes and return to the survey file.
40Close Interval Survey (CeCi)
>
Graph
tab.
Graph
tab, as well as tapping
View
>
Page 47
AI Allegro CX User’s Guide
Add Remarks and Test Point Information
The
Remarks
information in the remarks field of a survey record. For example, add a geographical
reference or the type of test point.
Add a remark
1
2
Add test point information
1
2
and
Test Point Information
Select a survey record and then tap
Double-tap a remark or enter the remark’s code number. CeCi inserts the remark in
the remarks field of the currently selected record. You can also enter your own
remark in the remarks field.
Select a survey record and then tap
Double-tap a test point and enter required values when prompted.
windows allow you to add additional
Remark
View
in the main menu.
>
Test Point Info
.
3
Ta p OK to enter the information in the survey record and return to the survey file.
Close Interval Survey (CeCi)41
Page 48
AI Allegro CX User’s Guide
View Survey Records and Show Bearing to Site
You can view survey records either as a list or single record. Tap
List
.
When viewing a single record with GPS coordinates, double-tap the GPS field to display
the
Site Locator
window (Figure 3-2).
Site Locator
The
when the Allegro is not receiving a valid GPS fix. The message
when the following conditions occur:
•The difference in latitude and longitude is more than 5 degrees.
•Latitude is above 85 degrees north or below 85 degrees south. Also expressed as
85-90N degrees latitude (northern hemisphere) and 85-90S degrees latitude
(southern hemisphere).
window. Tapping
window shows bearing and distance to a target location. Bearing is blank
View
>
Show bearing to site
View
>
Single record
also displays the
Out of Range
displays
or
Figure 3-2. Site Locator
Export a Survey File
You can export CeCi survey files as a dBase file (.dbf) or comma separated file (.csv) for use
with other software applications, such as Microsoft Excel.
To export a survey file, follow these steps:
1
Ta p
File
>
Export
2
Tap t he
3
Ta p OK to close the window.
4
Use Windows Mobile Device Center or ActiveSync to move a copy from the Allegro
CiData
AI
Type
field and select an export format from the list of options.
folder to your computer (
>
CiData
).
.
Start
>
File Explorer
>
Storage (or SD Card)
>
42Close Interval Survey (CeCi)
Page 49
Transfer a Survey File to PCS
AI Allegro CX User’s Guide
PCS utility files labeled
release of Allegro software in order for survey files to transfer properly from the Allegro to
PCS. For more information, refer to
To transfer a CeCi survey file to PCS:
1
Connect the provided serial cable to your computer and the Allegro. If you are
using a USB power dock, connect the USB cable to the power dock and your
computer.
2
At your computer, start WMDC or ActiveSync. Follow on-screen prompts to
establish communications. For ActiveSync users, click
a
Partnership
3
Start PCS and click
4
Click
Field Computer
5
Click
Receive CIS Data
6
Click
Retrieve File Listing
wToCmd.exe
. Clicking No allows you to create a
Module
and
CeFileXer.exe
Transfer Utility Files to PCS
>
Indirect Survey Manager (ISM)
>
Receive Data
and
From Allegro
and select the survey files you want to transfer.
.
must be updated for the current
(page 9).
No
when prompted to create
Guest
connection instead.
.
7
Click
Receive
displays. Refer to the PCS manual for information about viewing and managing
survey data in ISM.
and then click OK when the message
Processing file completed
Close Interval Survey (CeCi)43
Page 50
AI Allegro CX User’s Guide
Single Record View
(View > Single record)
List View
(View > List)
Graph of survey readings
(View > Options > Graph tab).
Station number (SN); Marker field
that may be blank or contain any
of the following markers based on
the survey setup: F (flag), G (gap),
or M (location entered manually);
and On/Off readings.
Survey remarks field. If the location
includes recorded GPS coordinates
and you view the survey file in
Single record mode, coordinates
display in the survey remarks field.
Current GPS coordinates. If satellite
communication has not been
established, GPS invalid displays.
When viewing in List View mode,
coordinates record in the survey file
but do not display.
On, off, and live DVM reading. ON or
OFF display based on the current
cycle position.
GPS displays when using GPS and satellite
communication has been established. If
the Allegro loses the GPS signal, GPS (Hilo)
displays.
G: receiving GPS locations from 4 or more satellites.
D: receiving differential GPS locations.
(blank): GPS is unavailable or not currently in use.
– – – : receiving invalid GPS data.
(1), (2), or (3): number of satellites in view.
Any of the following status indicators also
display when viewing in List View mode:
Survey File Features
The following example (Figure 3-3) shows the type of information that displays in a survey
file.
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
44Close Interval Survey (CeCi)
Figure 3-3. CeCi Survey File Features
Page 51
Shortcut Keys
Shortcut keys listed in the following table (Table 3-1) are an alternate method for using
certain commands in CeCi. Use the Allegro keypad to run any of the following commands.
Table 3-1. CeCi Shortcut Keys
CommandShortcut KeysDescription
AI Allegro CX User’s Guide
New<
Open<
Save<
Flag Marker <
Reset Flag Count<
Gap M ar ke r<
Capture Reading <
Go to first record<
Go to last record<
Go To…<
Ctrl><N
Ctrl><O
Ctrl><S
F
>Inserts a flag marker.
Ctrl><F
G
>Inserts a gap marker in Flagged
Enter
CTRL><Home
CTRL><End
Ctrl><G
>Opens a new survey.
>Displays the File Open window.
>Saves the survey.
>Reset Flag Count
mode.
>Captures a reading.
>Moves the cursor to the first
record
>Moves the cursor to the last
record
>Displays the Go To Location
window.
Skip<
Insert Record <
Delete Record <
Ctrl><K
CTRL><Ins
CTRL><Del
>Displays the Skip Distance
window (only in Fixed
Increment).
>Inserts a new record.
>Deletes a record.
Close Interval Survey (CeCi)45
Page 52
AI Allegro CX User’s Guide
Table 3-1. CeCi Shortcut Keys (continued)
CommandShortcut KeysDescription
Skip/Lock/Normal<
F3
>Toggles between Skip/Lock/
Normal in Fixed Increment
mode.
Pause<
Tes t Po i nt
Information
Open File Menu<
Open Move Menu<
Open Remark
Window
Ok / Cancel <
Navigate Open and
Save As Windows
F5
>Pauses timed readings.
<
Ctrl><T
>Displays the Test Point
Information window.
Alt><F
Alt><M
Ctrl><R
<
Ok
>Opens File menu.
>Opens Move menu.
>Opens Remark window.
> /
<Cancel>
Press <Ok> to apply changes or
<Cancel> to cancel changes.
<
Tab
>
Press <
Tab
> to move cursor
between fields.
Up/Down Arrows
<
<
Home/End Arrows
> and
>
Press <
End Arrows
Up/Down
> to navigate list of
files.
and
Home/
Navigate GPS Tab
Performs the following functions
in the GPS tab of Options:
C
>
<
• Press <
C
> to enable or
disable Clear GPS Location After.
S
>
<
• Press <
S
> to move cursor to
Seconds Without Updates.
<
G
>
• Press <
G
> to move cursor to
GPS Display Format.
46Close Interval Survey (CeCi)
Page 53
AI Allegro CX User’s Guide
Table 3-1. CeCi Shortcut Keys (continued)
CommandShortcut KeysDescription
Navigate Graph Tab<
>
Press <
G
G
Show Graph in Graph tab of
Options.
With Show Graph enabled:
<
U
>
• Press <
Upper Value.
L
>
<
• Press <
Lower Value.
> to enable or disable
U
> to move cursor to
L
> to move cursor to
Navigate Colors Tab<
<
W
>
E
>
<
Tab
>
Up/Down Arrows
<
Home/End Arrows
<
• Press <
W
> to move cursor
to Width.
Press <
E
> to enable or disable
Enable Color in the Colors tab of
Options.
With Enable Color enabled:
• Press <
Tab
> to move cursor
between field selection list
and color grid.
>
• Press <
Up/Down Arrows
>
to navigate f ield selection
list.
>
• Press <
or <
Home/End Arrows
Up/Down Arrows
> to
>
navigate color grid.
Close Interval Survey (CeCi)47
Page 54
AI Allegro CX User’s Guide
Notes
48Close Interval Survey (CeCi)
Page 55
DC Voltage Gradient (DCVG)
DCVG locates indications of pipeline coating defects. The software records the voltage
gradient and GPS location for further review and analysis later. DCVG collects data from a
data cane connected to the Allegro.
This chapter explains how to set up and use AI’s DCVG software. Topics include those in
the following list:
•Quick Start (page 49)
•Survey File Options (page 54)
•Add Remarks, Indication, and Test Point Information (page 56)
•View Survey Records and Show Bearing to Site (page 57)
•Export a Survey File (page 58)
4
•Shortcut Keys (page 60)
Quick Start
Procedures in this section explain how to set up the DCVG software to measure and record
direct current voltage gradients for a DCVG survey. As a user you will perform the
following actions:
•Connect data canes to the Allegro (page 50)
•Set survey properties (page 51)
•Set survey mode (page 51)
49
Page 56
AI Allegro CX User’s Guide
DCVG
•Set on/off survey type (page 52)
•Set DCVG properties (page 53)
•Set GPS properties (page 53)
•Save survey file (page 54)
•Record inspection readings (page 54)
Connect data canes to the Allegro
DCVG collects data using two data canes connected to the red and black jacks on the
Allegro connector panel. When an indication is detected, you can then define the size of
the indication.
Complete the following steps:
1
Plug data canes in the red positive (+) and black negative (–) jacks on the Allegro
connector panel; positive to positive, negative to negative (Figure 4-1).
2
Click the
DCVG
icon on the Allegro desktop to display the main DCVG window
(Figure 4-1).
The reading area at the top of the DCVG window displays the IR gradient (on
reading minus the off reading); millivolt reading (shown as 2 mV in the next
example); and polarity if enabled in the DCVG tab of Properties. The polarity arrow
displays when readings are greater than 3mV or less than –3mV.
Figure 4-1. DCVG Main Window
50DC Voltage Gradient (DCVG)
Page 57
Set survey properties
1
Ta p
File
>
Properties
2
Provide information in the following fields of the
to display the
Survey
tab.
AI Allegro CX User’s Guide
Survey
tab:
Segment
•
you plan to import DCVG data in PCS using Bridge,
match
Code and folder labeled
: Enter the name of the ROW (right-of-way) in this required field. If
ROW Code
Segment
in PCS. If these f ields do not match, PCS creates a new ROW
Unknown
in the PCS hierarchy.
name must
NOTE: PCS does not currently support direct import of Allegro DCVG survey
files (
Field Computer
Bridge, you can however import DCVG data using PCS Bridge (
See the PCS user manual for details.
Pipe:
•
•
Enter a pipeline code in this optional field. If you plan to import DCVG
data in PCS using Bridge,
ROW Code
pipeline codes, enter the appropriate pipeline code. If pipeline codes have not
been created in PCS, leave this field empty.
Tech:
DCVG data in PCS using Bridge, the surveyor’s name populates the
field in the Indirect Survey Manager (ISM) module.
entered earlier includes multiple, parallel pipelines with different
Enter the surveyor’s name in this optional field. If you plan to import
>
Receive Data
Pipe
is equivalent to
). If your PCS activation code includes
Tools
>
Pipeline Code
in PCS. If the
Surveyor
Bridge
).
•
Run:
Enter a unique survey name in this optional field. For example, include
station number, milepost number, date, or a combination of station number
and date, or milepost and station number. If you plan to import DCVG data in
PCS using Bridge, data in this field creates a new CI survey folder in ISM.
•
Date:
Enter a date or use the one automatically entered by DCVG.
Set survey mode
1
Tap t he
Flagged
2
Depending on the survey mode selected earlier, continue with the next procedure
or
Modes
or
Fixed increment
Set fixed increment mode properties
tab. Click the drop-down arrow in the
.
(page 52).
Mode
field and select either
DC Voltage Gradient (DCVG)51
Page 58
AI Allegro CX User’s Guide
Set flagged mode properties
1
Ta p
2
Enter the distance between flags or station markers in the
3
Click the drop-down arrow in the
Descending
4
If you want to monitor the number of reads per flag, tap
per flag
and select a percentage value. The Allegro beeps 3 times as a warning when the
number of reads for the current flag session is more than the average percentage
of reads taken for previous flag sessions.
5
Skip the next section and continue with
Set fixed increment mode properties
Metric
if you want readings recorded in meters instead of feet.
Direction
to indicate how station numbers increment in the survey file.
and then click the drop-down arrow in the
Set on/off survey type
field and select
Monitor record count
Warn at above average
Flag distance
Ascending
(page 52).
field.
or
field
1
Ta p
Metric
2
Enter the distance between reads in the
3
Click the drop-down arrow in the
Descending
if you want readings recorded in meters instead of feet.
to indicate how station numbers increment in the survey file.
Set on/off survey type
1
Tap t he
2
Tap the drop-down arrow in the
survey types:
•
•
On/Off
On/Off High/Low
tab.
GPS synchronized interrupters. Enter the same on/off times as set up for the
current interrupter in the
On/Off GPS Sync
GPS synchronized current interrupters. Enter the same on/off times as set up
for the current interrupter in the
and
Cycle begins with
properties in the
GPS
Increment
Direction
Survey Type
field and select
field.
Ascending
or
field and select one of the following
: Select this survey type for interrupted surveys using non-
ON time, OFF time, On Delay
, and
Off Delay
fields.
: Select this survey type for an interrupted survey using
ON time, OFF time, On Setup, Off Delay
,
fields. This survey type requires that you also set up
tab.
52DC Voltage Gradient (DCVG)
Page 59
Set DCVG properties
1
Tap t he
2
Measure and enter the on reading taken at the beginning and end of the survey in
the
3
Measure the
P/S Off, Begin,
and then press
4
Take readings at the beginning and end of the survey. Enter the difference in the
Half-cell calibration Begin
reading for either of these fields.
5
Ta p
DCVG window indicating the polarity of the reading during the survey.
DCVG
tab.
P/S On, Begin
Show DCVG Polarity
and
Off
reading taken at the beginning and end of the survey in the
and
End
Enter
AI Allegro CX User’s Guide
End
fields.
fields. Tap the V button to view a live voltage reading
on the Allegro keyboard to save the voltage reading.
and
End
fields. Tap the V button to view a live voltage
if you want a directional arrow to display in the main
Set GPS properties
1
Tap t he
2
Ta p
drop-down arrow in the
that identifies how often coordinates are included with readings.
3
Ta p
4
If you are using a second GPS receiver (dual GPS), complete the following steps:
a
b
c
5
Ta p OK to close
GPS
tab.
Record GPS Location
Record time of reading
Tap the drop-down arrow in the
the GPS receiver is connected to.
Tap the drop-down arrow in the
supported by the GPS receiver.
Tap
Read PPS from Internal GPS
receiver to provide a time stamp for readings.
Survey
to include coordinates with survey readings. Tap the
Record GPS Location
field and select an interval option
to include a GPS time stamp with readings.
Comm port
Baudrate
field and select the COM port
field and select a baud rate
if you want the Allegro internal GPS
properties.
DC Voltage Gradient (DCVG)53
Page 60
AI Allegro CX User’s Guide
Save survey file
Tap th e sav e ic on o r
survey file that has not previously been saved. Enter a name for the new survey file in the
Name
field and then tap OK.
File
Record inspection readings
Press
Enter
on the Allegro keypad or single-click the data cane to record readings in the
survey file.
Survey File Options
To set optional features in DCVG, tap
in the following list:
•Set optional audio and double-click properties (page 54)
•Set optional autosave properties (page 55)
•Set optional GPS properties (page 55)
>
Save
. The
Save As
View
window displays when working with a new
>
Options
. Topics in this section include those
•Set optional color properties (page 55)
Set optional audio and double-click properties
1
Tap t he
2
If you want the Allegro to beep when the voltage is above an absolute value you
specify, tap
value in the
3
Ta p
survey reading is overwritten.
4
If you want to double-click the data cane to mark a survey record with a flag, tap
Enable double-click detection
Misc
tab if it is not visible (
Beep for voltages above this absolute value
Voltage level
Beep when overwrite existing data
field.
View
.
>
Options
if you want the Allegro to beep when a
>
Misc
tab).
, and enter a warning
54DC Voltage Gradient (DCVG)
Page 61
Set optional autosave properties
1
Tap t he
2
Ta p
3
Enter a time interval in the
automatically save a survey file at regular time intervals based on the
(minutes)
File
tab (
View
Enable Autosave
you specify.
>
Options
.
>
Interval (minutes)
File
Set optional GPS properties
1
Tap t he
2
If you want DCVG to remove existing GPS coordinates when updated coordinates
are unavailable after a specified amount of time, tap
and enter the number of seconds in the
When GPS coordinates are older than 30 seconds, DCVG displays the time since
the last GPS update. When GPS coordinates are older than 15 seconds, DCVG
inserts an asterisk (*) after the coordinates.
GPS
tab (
View
>
Options
>
GPS
AI Allegro CX User’s Guide
tab).
field. This allows DCVG to
tab).
Clear GPS location after
seconds without updates
Interval
field.
3
Tap the drop-down arrow in
Decimal minutes
or
GPS display Format
Decimal degrees
Set optional color properties
1
Tap t he
2
Ta p
3
Select an option in the list and then a color in the color grid. Repeat this step for
each item in the list you want to assign a color. For example, to have readings that
do not meet criteria display in red text, select
the color grid.
Colors
Enable color
tab (
.
View
>
Options
>
.
Colors
and select either
tab).
Invalid Value
Degrees and
and the color
red
in
DC Voltage Gradient (DCVG)55
Page 62
AI Allegro CX User’s Guide
Add Remarks, Indication, and Test Point
Information
The
Remarks
information in the remarks field of a survey record. For example, add information for an
indication in
Topics in this section explain how to:
•Add a remark (page 56)
•Add indication information (page 56)
•Add test point information (page 57)
Add a remark
1
and
Test Point Information
Tes t P oi nt Inf o
Select a survey record and then tap
or additional geographical references in
windows allow you to add additional
Remark
in the main menu.
Remarks
.
2
Double-tap a remark or enter the remark’s code number. DCVG inserts the remark
in the remarks field of the currently selected record. You can also enter your own
remark in the remarks field of the survey file.
Add indication information
1
Ta p
View
>
Test Point Info
2
Double-tap
3
Enter information about the indication in the following fields of the
aID:
bType:
Options include
Anodic
cSignal Strength:
automatically calculates and enters values in the
Signal strength is the pipe-to-soil
reading (P/S On – P/S Off).
Indication
Enter an identification number for the indication.
Take readings at the indication site until you reach remote earth. Press the data
cane button to capture readings in DCVG, or press
keypad. DCVG automatically calculates
Tap OK to return to the survey file.
tab and complete the following steps:
Enter
Tota l IR
.
on the Allegro
Add test point information
1
Select a survey record and then tap
2
Double-tap a test point and enter required values when prompted.
3
Ta p OK to enter the information in the survey record and return to the survey file.
View
>
Test Point Info
.
View Survey Records and Show Bearing to Site
You can view survey records either as a list or single record. Tap
List
.
When viewing a single record with GPS coordinates, double-tap the GPS field to display
the
Site Locator
window (Figure 4-2).
The
Site Locator
when the Allegro is not receiving a valid GPS fix. The message
when the following conditions occur:
•The difference in latitude and longitude is more than 5 degrees.
•Latitude is above 85 degrees north or below 85 degrees south. Also expressed as
85-90N degrees latitude (northern hemisphere) and 85-90S degrees latitude
(southern hemisphere).
window. Tapping
window shows bearing and distance to a target location. Bearing is blank
View
>
Show bearing to site
View
>
Single record
also displays the
Out of Range
displays
or
Figure 4-2. Site Locator
DC Voltage Gradient (DCVG)57
Page 64
AI Allegro CX User’s Guide
Export a Survey File
You can export DCVG survey files as a dBase file (.dbf) or comma separated file (.csv) for
use with other software applications, such as Microsoft Excel.
To export a survey file, follow these steps:
1
Ta p
File
>
Export
2
Tap t he
3
Ta p OK to close the window.
4
Use Windows Mobile Device Center or ActiveSync to move a copy from the Allegro
CiData
AI
Type
field and select an export format from the list of options.
folder to your computer (
>
CiData
).
.
Start
>
File Explorer
>
Storage (or SD Card)
>
58DC Voltage Gradient (DCVG)
Page 65
Survey File Features
Single Record View
(View > Single record)
List View
(View > List)
Live on/off reading, IR gradient, and
polarity arrow.
Status line with any of the following
information:
is indicated with a right pointing
arrow, negative (–) is indicated with
a left pointing arrow.
Recorded station number (SN), marker,
and IR gradient.
When viewing in List mode, also includes
Remarks field with indication data (number,
type, signal strength, and remarks).
Single record mode: Remark field with
recorded indication data. Second remark
field displays with GPS coordinates when
set up in On/Off GPS Sync mode.
List Mode: Live GPS coordinates,
number of satellites in view, and PDOP
signal strength.
Shows recorded data for a selected
record, such as indication number,
type, signal strength, and remarks.
Shows any of the following when
capturing data for a survey record:
Gps: Receiving satellite signal.
Survey file is set up in On/Off GPS
Sync mode.
Gps (HiLo): Not receiving satellite
signal; data is captured in HiLo
mode instead. Survey file is set up
in On/Off GPS Sync mode.
HiLo: Survey file is set up in On/Off
High/Low mode.
F:0: Flag marker and flag count.
Survey file is set up in Flagged
mode and option Monitor record count per flag is enabled.
The following example shows the type of information that displays in a DCVG survey file
(Figure 4-3).
1
2
3
4
5
Figure 4-3. DCVG Survey File Features
AI Allegro CX User’s Guide
1
2
3
4
1
2
3
4
5
5
DC Voltage Gradient (DCVG)59
Page 66
AI Allegro CX User’s Guide
Shortcut Keys
Shortcut keys listed in the next table (Table 4-1) are an alternate method for using certain
commands in DCVG. Use the Allegro keypad to run any of the following commands.
Table 4-1. DCVG Shortcut Keys
CommandShortcut KeysDescription
New<
Open<
Save<
Flag Marker<
Gap<
Capture Reading <
Go to first record<
Go to last record<
Ctrl><N
Ctrl><O
Ctrl><S
F
>Enters an F in the record to
G
>Enters a G in the record to show
Enter
CTRL><Home
CTRL><End
>Creates a new survey.
>Displays the File Open window.
>Saves the survey.
show a Flag.
a Gap.
>Captures a reading.
>Moves the cursor to the first
record
>Moves the cursor to the last
record
Go To…<
Skip<
Insert Record <
Delete Record <
Tes t Po i nt
Information
60DC Voltage Gradient (DCVG)
Ctrl><G
Ctrl><K
CTRL><Ins
CTRL><Del
<
Ctrl><T
>Displays the Go To location
window.
>Displays the Skip Distance
window (only in Fixed
Increment).
>Inserts a new record.
>Deletes a record.
>Displays the Test Point
Information window.
Page 67
Notes
AI Allegro CX User’s Guide
DC Voltage Gradient (DCVG)61
Page 68
AI Allegro CX User’s Guide
62DC Voltage Gradient (DCVG)
Page 69
Annual/Periodic Survey
(Periodic Survey)
Periodic Survey (PS) measures voltage readings for annual and periodic surveys. The
software collects survey readings from test leads connected to the Allegro. PS is used in
conjunction with AI’s PCS software. Facility and inspection fields are established in PCS and
then transferred to the Allegro. After completing a survey, data is then transferred from
the Allegro back to PCS.
NOTE: The PCS survey route includes information and reading fields for ROW (right-of-
way) facilities to be surveyed. For information about how to build and transfer a survey
route to the Allegro, refer to the PCS user manual.
Topics in this chapter include those in the following list:
5
•Quick Start (page 64)
•Timed Readings (page 68)
•Set Autosave Properties (page 69)
•Transfer a Survey Route to PCS (page 69)
•Copy a Survey Route to a Computer (page 70)
•Survey Route Features (page 71)
•Shortcut Keys (page 72)
63
Page 70
AI Allegro CX User’s Guide
Rectifier Reading
(–)
(+)
Test Point Reading
(–)
(+)
Quick Start
Procedures in this section explain how to set up the Periodic Survey software to record
readings for an annual or periodic survey. As a user you will perform the following actions:
•Connect test leads to the Allegro (page 64)
•Set on/off survey method (page 65)
•Set GPS properties (page 65)
•Add or delete a new site (page 66)
•Change font properties (page 67)
•Save survey route (page 68)
•Record inspection readings (page 68)
Connect test leads to the Allegro
PS records facility inspection readings using the Allegro digital voltmeter and a data cane
connected to the red and black jacks on the Allegro connector panel.
Complete the following steps:
1
Plug test leads in the red positive (+) and black negative (–) jacks on the Allegro
connector panel; positive to positive, negative to negative.
2
Click the PS icon on the Allegro desktop to start the software (Figure 5-1).
3
Ta p
File
>
Open
. Select a survey route in the
Open
window and then tap OK.
Figure 5-1. PS Survey Route
64Annual/Periodic Survey (Periodic Survey)
Page 71
Set on/off survey method
1
If you plan to take on/off potential readings, tap
On/Off
2
Tap the drop-down arrow in the
following survey methods:
•
•
tab.
High/Low
: Select this survey method for an interrupted survey using nonGPS synchronized interrupters. Enter the same on/off times as set up for the
current interrupter in the
Delay
fields.
GPS Sync
: Select this survey method for an interrupted survey using GPS
synchronized current interrupters. Enter the same on/off times as set up for
the current interrupter in the
Off Delay
, and
Cycle begins with
also set up properties in the
If on/off time settings are incorrect for either High/Low or GPS Sync, an error
message displays with suggested settings. The error message includes a
suggested setting with a calculated minimum value inside parentheses.
AI Allegro CX User’s Guide
View
>
Options
On-Off Method
field and select one of the
ON time, OFF time, On Delay
to display the
, and
Instant Off
ON time, OFF time, Instant On Setup, Instant
fields. This survey type requires that you
GPS
tab (
View
>
Options
>
GPS
tab).
NOTE: The
commands
Disable
Insert GPS
submenu.
Set GPS properties
1
If you want to include GPS coordinates with readings, tap
2
Set GPS
following these steps:
a
b
c
Display Format
Tap
View
>
Options
Tap the drop-down arrow in the
Degrees and Decimal minutes
window.
Tap t he
Misc
tab and then tap
close the window.
option in the On-Off Method drop-down list disables the
in the
Edit
and enable
>
GPS
tab.
menu and
Show Bearing-distance to site
Display Format
or
Decimal degrees
Show Bearing-distance to site
Turn ON
in the
Edit
Edit > GPS
>
GPS
field and select either
. Tap OK to close the
>
Tur n ON
using the
. Tap OK to
.
Annual/Periodic Survey (Periodic Survey)65
Page 72
AI Allegro CX User’s Guide
3
If you are using a second GPS receiver (dual GPS), complete the following steps:
a
b
c
d
Add or delete a new site
Complete the following steps to add or delete a new site. New sites added on the Allegro
are marked with a bullet (•) in the
Complete the following steps:
Tap
Edit
>
GPS
>
Gps Settings
Tap the drop-down arrow in the
to display the
Comm port
field and select the COM port
the GPS receiver is connected to.
Tap the drop-down arrow in the
Baudrate
field and select a baud rate
supported by the GPS receiver.
Tap
Read PPS from Internal GPS
if you want the Allegro internal GPS
receiver to provide a time stamp with readings.
Site List
and can be deleted.
GPS Port Settings
window.
1
Ta p
View
2
Ta p
Options
properties:
a
Tap t he a r ro w in
proximity
b
Tap t he a r ro w in
Tap
3
To add a new site:
a
Tap
b
Tap a facility type in the list to select a template for the new site.
c
Tap OK to close the window and return to the survey route.
>
Site List
.
and complete the following steps to set up
Order site by
and select either
.
Show
OK
to return to
Add new site
and select either
Site List
.
.
All sites
Site List
Normal order
or
Only unsurveyed sites
display
or
GPS
.
66Annual/Periodic Survey (Periodic Survey)
Page 73
d
Click the drop-down arrow in the
select
Other
and then enter a new ROW code.
ROW Code
AI Allegro CX User’s Guide
field. Select a ROW code or
If you selected
Other
, complete the following steps to prevent entering an
incorrect ROW code:
1)
Highlight an existing ROW code by pressing <
the Allegro keypad, and then press <
2)
Tap the ROW code field of the new site and press <
Ctrl
Shift
> <C>.
> <
Blue
> <
Ctrl
> <V>. Edit the
ROW code of the new site as needed.
e
Tap OK to return to the survey route.
IMPORTANT: If the
ROW Code
field is empty when the survey route is
transferred to PCS, a new ROW code is created in the PCS hierarchy labeled
From Allegro
f
Tap t he
g
Enter data for the new site in the Information fields. Information and Reading
.
Milepost
field and enter the new site’s milepost number.
fields are separated with a horizontal line. Information fields are above the line
and Readings fields are below the line.
End
> on
4
To delete a site added on the Allegro:
a
Tap
View
>
Site List
b
Tap a site marked with a bullet (•) and then tap
c
Tap
Yes
when the message
Change font properties
1
Ta p
View
>
Options
2
Click the drop-down arrow in the
Edit field
Site List
List).
.
is a list of templates for adding a new site in the survey route (View > Site
Edit caption
fields.
3
Click the drop-down arrow in the
>
Fonts
refers to field names and
.
Delete this site?
.
Item
Font
Delete
.
displays.
field and select
Edit field
Site List, Edit caption
refers to data entered in
field and select a font type.
, or
Annual/Periodic Survey (Periodic Survey)67
Page 74
AI Allegro CX User’s Guide
4
Click the drop-down arrow in the
5
Repeat steps 2 through 4 to change font properties for another item. When you
finish, click
Save survey route
Size
OK
to return to the survey file.
field and select a font size.
Tap the save icon or tap
Record inspection readings
Select a reading field and then press
voltmeter. Press
survey file.
Enter
Timed Readings
When the survey route is set up in PCS with Allegro prompts for the following fields,
these same fields are available in PS for timed readings:
and
P/S Sample Time
To take timed readings, follow these steps:
1
Select one of the following fields and then press
Min P/S, Max P/S, Average P/S
File
>
Save
to save changes in the survey route.
Enter
on the Allegro keypad to activate the digital
again or single-click the data cane to capture the reading in the
Min P/S, Max P/S, Average P/S
.
Enter
on the Allegro keypad:
, and
P/S Sample Time
.
,
Figure 5-2. Timed Reading Fields
2
When the
Duration
readings.
3
Ta p
Start
the survey route.
Ta pp in g
68Annual/Periodic Survey (Periodic Survey)
Averaged Reading Survey
field and select the length of time the Allegro should take timed
to begin timed readings. When timed readings finish, tap OK to return to
Stop
anytime during the cycle stops timed readings.
window displays, tap the arrow in the
Page 75
Set Autosave Properties
AI Allegro CX User’s Guide
PS provides an
intervals. To set
1
Ta p
2
Ta p
3
Ta p OK to close the window and return to the survey route.
Autosave
Autosave
View
>
Enable Autosave
option that automatically saves the survey route at regular
properties, follow these steps:
Options > Misc
tab.
and select a time interval in the
Transfer a Survey Route to PCS
PCS utility files labeled
release of Allegro software in order for survey files to transfer properly from the Allegro to
PCS. For more information, refer to
To transfer a PS survey route to PCS, follow these steps:
1
Connect the provided serial cable to your computer and the Allegro. If you are
using a USB power dock, connect the USB cable to the power dock and your
computer.
wToCmd.exe
and
CeFileXer.exe
Transfer Utility Files to PCS
Interval (minutes)
must be updated for the current
on page 9.
field.
2
At your computer, start WMDC or ActiveSync. Follow on-screen prompts to
establish communications. For ActiveSync users, click
a
Partnership
3
Start PCS and open any module other than Indirect Survey Manager (ISM). For
example, click
4
Click
Field Computer
window.
5
Click
Receive Facility Data
6
Select the survey file(s) you want to transfer to PCS and then click
the window
survey to Allegro data and then click
7
Click OK when the message
complete.
. Clicking No allows you to create a
Module
Options for Receiving Data
>
Cathodic Protection Data Manager (CPDM)
>
Receive Data
>
From Allegro
Receive Allegro Data
to display the
displays, choose an option to assign a
Continue
>
No
when prompted to create
Guest
connection instead.
Receive Allegro Data
Retrieve File Listing
Receive
.
displays stating the process is
.
.
. When
Annual/Periodic Survey (Periodic Survey)69
Page 76
AI Allegro CX User’s Guide
Copy a Survey Route to a Computer
Complete the following steps to copy one or more PS survey routes to a computer:
1
Connect the provided serial cable to your computer and the Allegro. If you are
using a USB power dock, connect the USB cable to the power dock and your
computer.
2
At your computer, start WMDC or ActiveSync. Follow on-screen prompts to
establish communications. For ActiveSync users, click
a
Partnership
3
In WMDC, point the mouse at
contents of your device
. Clicking No allows you to create a
File Management
.
Guest
and then click
No
when prompted to create
connection instead.
Browse the
In ActiveSync, click the
Allegro in Windows Explorer.
4
Click
Storage
5
Double-click the
sort files by name.
6
Select and drag the
(or SD Card) and then double-click the AI folder.
PsData
.dat
Explore
folder. Click the
and matching
icon in the tool bar to display the contents of the
NOTE: PS survey routes use two files; one with a
a
.vls
extension. Both are labeled with the same filename.
Name
column in Windows Explorer to
.vls
file to your computer.
.dat
extension and the other with
70Annual/Periodic Survey (Periodic Survey)
Page 77
Survey Route Features
1
3
2
1
Information fields (above horizontal
line) from Allegro prompts set up in
PCS route file.
Reading fields (below horizontal line)
from Allegro prompts set up in PCS
route file.
2
Status bar with information for the
currently selected field displaying in
the following status panes.
3
1st status pane: may be empty or
display the last recorded reading if
included in the PCS route file.
2nd status pane: displays GPS, DGPS,
HILO, or DVM range and function based
on the On-Off Method setup in the
survey file (View > Options > On/Off
tab).
3rd status pane: displays date and time
of previous reading if included in PCS
route file or, bearing-distance if set up in
the Allegro and PCS route file includes
GPS coordinates.
4th status pane: displays the record
number of the currently viewed facility
and the total number of facility records in
the survey file. Percentage value identifies
percentage of readings taken based on
the total number of facility records.
5th status pane: displays the page number
of the page you are viewing and the total
number of pages in the survey file.
A PS survey route includes three main areas of information as shown in the next example
(Figure 5-3).
AI Allegro CX User’s Guide
Figure 5-3. Survey Route Features
Annual/Periodic Survey (Periodic Survey)71
Page 78
AI Allegro CX User’s Guide
Shortcut Keys
Shortcut keys listed in the following table (Table 5-1) are an alternate method for using
certain commands in PS. Use the Allegro keypad to run any of the following commands.
Table 5-1. PS Shortcut Keys
CommandShortcut KeysDescription
Record Reading<
Record GPS
Coordinates
Insert GPS
Coordinates
Select Data in a Field<
Enter
>Records a reading. Options
include:
• Select reading field and
press <Enter> to activate the
digital voltmeter. Press
<Enter> again to record the
reading.
• Select timed reading field
and press <Enter> to set up,
start, stop, or cancel timed
reading mode.
<
F4
>Records GPS coordinates when
cursor is in a reading field.
F4
>Insert GPS coordinates when
<
cursor is in a reading field and
GPS status is running in the
background.
Shift><Blue><Home
Select data from the current
>
cursor location to the end of the
field.
Copy, Cut, Paste<
Undo<
Open<
72Annual/Periodic Survey (Periodic Survey)
Shift><Blue><End
<
CTRL><C
CTRL><X
<
<
CTRL><V
Ctrl><Z
Ctrl
>
>
>
>Undo last change.
> <O>Opens the File Open window.
>
Select data from the current
cursor location to the beginning
of the field.
Copy selection to the clipboard.
Remove selection and copy to
clipboard.
Paste data from clipboard.
Page 79
AI Allegro CX User’s Guide
Table 5-1. PS Shortcut Keys (continued)
CommandShortcut KeysDescription
CTRL
Save<
> <S>Save survey file.
Next Page<
Previous Page<
Previous Site <
Next Site <
Open File Menu<
Open Edit Menu <
Open View Menu<
Navigate
Information and
Reading Fields
Navigate any
Window or Tab
Ctrl
> <
Down
>Display next page of a multi-
page site.
Ctrl
> <Up>Display previous page of a
multi-page site.
Shift
> <
Up Arrow
Shift
> <
Down Arrow
Alt
> <F>Opens File menu.
Alt
> <E>Opens Edit menu.
Alt
> <V>Opens View menu.
<
Alt
> <U>Moves cursor between
>Display previous site.
>Display next site.
information and reading fields.
<
Tab
>
• Press <Tab> to move cursor
from one field to another.
Up/Down Arrow
<
>
• Press <Up/Down Arrows> to
move cursor in a drop-down
list.
Enter
<
Ok
<
>
> / <
• Press <Enter> to accept a
selection in a drop-down list.
Cancel
>
• Move cursor to <Ok> and
then press <Enter> to apply
changes.
• Move cursor to <Cancel>
and then press <Enter> to
cancel changes.
Annual/Periodic Survey (Periodic Survey)73
Page 80
AI Allegro CX User’s Guide
Notes
74Annual/Periodic Survey (Periodic Survey)
Page 81
Recommendations for
Interrupted On/Off Settings
This chapter provides recommendations for on/off settings in an interrupted survey set up
in AiDvm, CeCi, or Periodic Survey.
A
When a survey file is set up in
recommends the survey file also be set up with
a backup if the satellite signal is lost. The Allegro defaults to
mode until the satellite signal is re-acquired.
Table A-1. Suggested On/Off Settings
On/Off High/Low setup for 1 second cycle
A minimum/maximum reading from a sample of readings. Of the remaining 45
readings, the most negative reading is equal to the
reading is equal to the
60 readings per cycle (60 readings per second):
0.7 on
0.3 off
0.8 on
200 mSec On Delay
50 mSec Off Delay
200 mSec On Delay
On/Off GPS Sync
off
reading.
or
On/Off GPS Real-time
On/Off High/Low
on
reading and the most positive
Filters out 12 most negative readings
Filters out 3 most positive readings
Filters out 12 most negative readings
settings. This serves as
On/Off High/Low
mode, AI
survey
0.2 off
50 mSec Off Delay
Filters out 3 most positive readings
75
Page 82
AI Allegro CX User’s Guide
Table A-1. Suggested On/Off Settings (continued)
On/Off High/Low setup for greater than 1 second cycle
A minimum/maximum reading from a sample of readings. Of the remaining 99
readings, the most negative reading is equal to the
reading is equal to the
120 readings per cycle (60 readings per second):
off
reading.
on
reading and the most positive
1.5 on
0.5 off
On/Off GPS Sync setup for 1 second cycle
250 mSec On Delay
100 mSec Off Delay
Filters out 15 most negative readings
Filters out 6 most positive readings
A minimum/maximum reading from a sample of readings. Of the remaining 99
readings, the most negative reading is equal to the
reading is equal to the
off
reading.
on
reading and the most positive
A snapshot of readings in a certain time period:
off
off
off
cycle.
cycle.
off
cycle.
cycle.
0.7 on
0.3 off
0.8 on
0.2 off
On/Off High/Low setup for 1 second cycle
200 mSec On Setup
150 mSec Off Delay
200 mSec On Setup
100 mSec Off Delay
Takes reading 200 mSec before the
Takes reading 150 mSec into the
Takes reading 200 mSec before the
Takes reading 100 mSec into the
A minimum/maximum reading from a sample of readings. Of the remaining 45
readings, the most negative reading is equal to the
reading is equal to the
1.5 on
0.5 off
250 mSec On Setup
250 mSec Off Delay
76Recommendations for Interrupted On/Off Settings
off
reading.
on
reading and the most positive
Takes reading 250 mSec before the
Takes reading 250 mSec into the
off
off
cycle.
cycle.
Page 83
AI Allegro CX User’s Guide
Table A-1. Suggested On/Off Settings (continued)
On/Off GPS Real-time setup for greater than 2 second cycle
8.0 on
2.0 off
GPS-RT
200 mSec On Delay
250 mSec Off Delay
50 mSecNo readings 50 mSec before
Setup
Time
Recommended
solid state switches.
GPS-RT Setup Time
Starts reading 200 mSec into on cycle (off-to-on).
off
Starts reading 250 mSec into
Delay
.
No readings 50 mSec before
Delay
.
is 50 mSec for Mercury switches and 30 mSec for
cycle (on-to-off).
off
cycle to
on
cycle to
Off
On
Recommendations for Interrupted On/Off Settings77
Page 84
AI Allegro CX User’s Guide
Notes
78Recommendations for Interrupted On/Off Settings
Page 85
FAQs
B
This chapter provides answers to frequently asked questions (FAQs) about the Allegro
Field PC and AI Allegro software. If you have a question not covered in this chapter,
contact Technical Services at
How do I determine which version of software is installed on the Allegro?
pcstechservices@aiworldwide.com.
The software version is listed in the
CeCi and then tap
version as shown in the next example.
How do I get the latest version of software available for the Allegro?
Contact Technical Services at pcstechservices@aiworldwide.com for a
Password
to access files for download.
View
>
About CeCi
About
window of each AI software. For example, start
. The first line of information identifies the software
User Name
and
79
Page 86
AI Allegro CX User’s Guide
I have a Trimble GPS receiver connected to the Allegro with successful
communication established between the two. Why does the Allegro show
HiLo mode instead of GPS mode?
Using an external GPS receiver with the Allegro is referred to as dual GPS. Although the
Allegro and external GPS are communicating, the following items must also be set up on
the Allegro:
•GPS patch antenna is plugged in the GPS ANT connector on the Allegro.
The Allegro includes an internal GPS module that uses the patch antenna to
acquire a GPS timing signal from the satellite. If the GPS timing signal is
unavailable, the Allegro operates in HiLo mode instead of GPS mode.
•GPS Pod Setup is set correctly for dual GPS. Tap Start > File Explorer > My Device >
Storage > Program Files > GPSPodSetup and verify settings match those shown in
the next figure.
•GPS Status is set correctly for dual GPS. Tap Start > GpsStatus > Options and verify
settings match those shown in the next figure.
80FAQs
Page 87
AI Allegro CX User’s Guide
Based on the version of the DAQ card,
AI Allegro software reads and sets the
maximum voltage as 150V or 250V.
How do I enlarge the font size or change the touchscreen brightness and
contrast settings?
To increase or decrease the font size
1
Ta p
Settings
2
Move the slider to increase or decrease text size. To change text size and font in a
PS survey file tap
>
System
View
tab >
>
Fonts
Screen
.
>
Text S i z e
tab.
To change the backlight brightness
1
Ta p
Settings
2
Press <
brightness. To decrease the contrast and brightness, press <
simultaneously.
>
Orange
System
tab >
Backlight
>
Brightness
tab.
> <F5> keys simultaneously to increase the contrast and
Orange
> <F4> keys
How do I find the version number of the DVM card?
To determine the version of the DAQ card:
1
Run any of the AI Allegro software. For example, double-tap the
the Allegro desktop.
2
Ta p
Options
version. The voltage range supported by the various DAQ card versions is
identified in the following list:
150V maximum:
•
•
250V maximum:
>
About
tab to display the
About
window and view the DAQ card
DAQ FF and DAQ 0B
DAQ 08, DAQ 09, and DAQ 0A
AI-DVM
icon on
FAQ s81
Page 88
AI Allegro CX User’s Guide
How can I verify interruption or make timing adjustments to ensure the
Allegro is capturing the correct Structure P/S and Structure IRF at the
correct time?
Start AI-DVM to complete the following steps:
1
Ta p
2
Set up on/off settings and then tap OK.
3
Ta p
For more information, see
Options
Graph
>
On/Off
to view a waveform of on/off readings as shown in the next example.
tab >
Enable On/Off mode
DVM Graph Overview
.
(page 27).
What can I do if I cannot get a GPS satellite fix?
Verify the following settings are correct:
•Run the GPS Status software and verify COM port settings are correct.
•Run the GPS Pod Setup software and verify settings are correct. All software must
be closed before viewing settings in GPS Pod Setup.
•Verify the GPS antenna has a clear view of the sky and is securely connected to the
Allegro.
Why are GPS coordinates not recording in my Periodic Survey file?
Verify the cursor is in a reading field in the bottom pane of the survey file. Tapping a
reading field places the cursor in the field.
Why is the Insert GPS command unavailable for selection in the Periodic
Survey software?
Verify the GPS Status software is running and the cursor is in a reading field in the bottom
pane of the survey file. Tapping a reading field places the cursor in the field.
82FAQs
Page 89
AI Allegro CX User’s Guide
Indicates SKIP mode.
Why does CeCi switch to Hi-Lo mode when my survey file is set up with
GPS Sync or GPS Real-Time mode?
CeCi automatically switches to Hi-Lo mode when the Allegro loses the internal GPS time
signal. When setting up a survey file in GPS Sync or GPS Real-time mode, AI recommends
that you also set up the survey file in Hi-Lo mode.
Why do on/off readings look incorrect in CeCi?
•Run the AI-DVM software and view the waveform graph. Use the graph to verify
satellite communication and on/off settings are correct.
•View the AI-DVM waveform graph several times before taking survey readings.
This allows you to change on/off delay times as needed to get the best on/off
capture.
How do I include Remarks and GPS coordinates in a CeCi survey file when
using Skip/Lock/Normal mode?
The following procedure applies to a CeCi survey set up in Fixed Increment mode. If you
want to view the center line (CL) in a skipped section, verify the survey file is also set up
with the option Retain Skipped records in Skip Mode (View > Options > File tab).
Complete the following steps:
1
Place the cursor in the pipe-to-soil (P/S) field and then press <
Move
>
Skip/Lock/Normal
Pressing <Ctrl> <Z> toggles Skip, Lock, and Normal modes. In Skip mode, CeCi
inserts (SKIP) in the Remarks field of the selected survey record.
.
Ctrl
> <Z> or tap
FAQ s83
Page 90
AI Allegro CX User’s Guide
Remarks Field
Remarks Field
2
Move the cursor to the Remarks field by tapping the field or pressing the
button (right arrow).
3
Ta p
to insert it in the survey record and close the window.
Remark
Tab
to open the Remarks window. Select and then double-tap the remark
4
Press
Enter
to move the cursor to the P/S field.
84FAQs
Page 91
AI Allegro CX User’s Guide
Beginning of skip section.
End of skip section.
5
Press the down arrow to move the cursor to the next station number (SN).
Continue to survey to the other end of the SKIP (such as a road crossing, railroad
crossing, exposed pipe, and so on).
6
Press <
Ctrl
> <Z> to toggle from SKIP to normal mode. Move the cursor to the
Remarks field and add another remark.
7
Press
Enter
and then the
down arrow
to move to the next SN and take a reading.
The survey file contains information shown in the image on the next page, including GPS
coordinates when using GPS.
FAQ s85
Page 92
AI Allegro CX User’s Guide
86FAQs
Page 93
Notes
AI Allegro CX User’s Guide
FAQ s87
Page 94
AI Allegro CX User’s Guide
88FAQs
Page 95
Utility Software
Information in this chapter explains how to use and set up the following utility software:
•GPS Status (page 87)
•GPS Config (page 93)
•Save System (page 95)
•Set DAQ Registry Keys (page 96)
GPS Status
Use GPS Status (Figure C-1) to perform any of the following tasks:
•view current GPS data, such as number of satellites in view, GPS coordinates,
amount of time since the last GPS fix, and current GPS time.
C
•enable the
•enable the
•set a
•change COM port and baud rate settings for a second GPS receiver (dual GPS).
•set up the Allegro to use the PPS timing signal received by the internal GPS module
•copy GPS coordinates to the system clipboard or an opened PTab spreadsheet file.
Display Format
degrees).
instead of a second GPS receiver.
Offset
option to view the distance between two points.
Beep
option if you want the Allegro to beep when GPS readings update.
for GPS coordinates (degrees and minutes or decimal
To start GPS Status, double-tap the GpsStatus icon on the Allegro desktop to display the
Gps Statu s
window shown below. See Table C-1 on page 88 for additional information.
NOTE: If the Allegro is unable to open the COM port, the message Unable to open GPS
port COM3 (-2,317) displays. Exit and then restart GPS Status to allow the Allegro to open
the port. The value shown in parentheses is an internal code used by AI for
troubleshooting purposes.
Figure C-1. GPS Status
Table C-1. GPS Status Field Descriptions
FieldDescription
SatellitesCurrent number of satellites tracked by the GPS receiver display
in this status line. If using dual-GPS, status line displays the
number of satellites as
#/# Satellites in view
. The first number
applies to the external GPS receiver, the second number applies
to the internal GPS receiver.
Three (3) satellites are required for coordinate calculations. Four
(4) satellites are required for calculating a 3D position (latitude,
longitude, and elevation). The more satellites tracked, the
higher accuracy of the GPS receiver.
88Utility Software
Page 97
AI Allegro CX User’s Guide
Table C-1. GPS Status Field Descriptions (continued)
FieldDescription
GPS statusStatus line may include any of the following messages:
• Receiving GPS
• Initializing
• Waiting
Information about the serial connection displays in parentheses
during the startup process, such as
Initializing (V 236).
shows a GPS status byte (V or FF) and the number of received
characters. GPS status bytes (V and FF) indicate whether or not
the receiver is receiving GPS packets.
packets received and
FF
indicates no GPS packets received.
V
indicates valid GPS
If received characters is zero (0) or does not increase, verify the
GPS receiver is securely connected to the Allegro and
communication settings are correct (COM port and baud rate).
It
GPS coordinatesShows longitude, latitude, and elevation coordinates received
from a minimum of 3 satellites.
Coordinates update every second. With a clear view of the sky,
GPS accuracy without differential correction is about 10 meters
(32.8 feet). Sub-meter accuracy is reported after applying
differential correction when using a second GPS receiver (dual
GPS), such as the Trimble GPS Pathfinder Pro XR.
DOP valuesDOP (dilution of precision) values identify the accuracy of GPS
readings. When a DOP value is zero (0), the GPS receiver does
not report the value. When the value is between 1 and 3, GPS
accuracy is good.
PDOP
refers to position dilution of precision;
vertical dilution of precision;
of precision; and
TDOP
HDOP
refers to time dilution of precision.
refers to horizontal dilution
VDOP
refers to
Utility Software89
Page 98
AI Allegro CX User’s Guide
Table C-1. GPS Status Field Descriptions (continued)
FieldDescription
Age of fixShows the time since the last GPS satellite fix.
Age of fix
appears only when the GPS satellite signal is lost. It appears ten
seconds after losing the satellite signal. Information displays in
the following manner:
• When age is less than 10 seconds, field is empty.
• When age is less than 1 minute, number of seconds
display as
nn sec
, such as
35 sec
.
• When age is less than 60 minutes, number of minutes
and seconds display as
mm:ss
, such as
12:14
.
• When age is undetermined, an asterisk (*) displays.
GPS timeGPS time displays when a GPS time signal is received and the
Offset
option is disabled.
Updates display every second when GPS time is available. GPS
time displays in 24-hour format and may include the suffix
P
letters
time signal is being received.
and/or Z. P indicates a PPS (one pulse-per-second)
Z
indicates a GPS time packet is
being received.
Offset
When GPS time is unavailable or the GPS time signal is more
than 10 minutes old, this area of the GPS Status window is
empty. When
Offset
is enabled, offset values (such as 2, 1, 5) or
asterisks (*, *, *) display instead of GPS time.
Offset
shows the distance between two points. To use
tap
Offset
and then move to a different location. Offset values
Offset
display inside parentheses and are calculated as feet or miles.
For example, with an offset of (1, 2, 3):
• 1 is the east-west offset (W positive).
• 2 is the north-south offset (N positive).
• 3 is the vertical offset.
An offset distance higher than 0.1 degree (about six miles)
displays as asterisks inside parentheses (*,*,*). When
Offset
is
enabled, GPS time does not display.
,
90Utility Software
Page 99
AI Allegro CX User’s Guide
Table C-1. GPS Status Field Descriptions (continued)
FieldDescription
BeepIf you want the Allegro to beep each time GPS readings update,
tap
Beep
to enable the option.
OptionsTap
receiver (dual GPS):
CopyTap
opened PTab spreadsheet file.
PTabTap
opened PTab file.
Options
to set the following parameters for a second GPS
• Select a COM port and baud rate.
• Ta p
Read PPS from Internal GPS
if you want to use the
Allegro internal GPS module for the PPS timing signal.
• Select a GPS display format (
Decimal degrees
Copy
to copy coordinates to the system clipboard or an
PTab
to paste GPS coordinates in an active cell of an
).
Degrees and Minutes
or
Utility Software91
Page 100
AI Allegro CX User’s Guide
GPS Status Shortcut Keys
Shortcut keys listed in the following table (Table C-2) are an alternate method for using
certain commands in AI-DVM. Use the Allegro keypad to run any of the following
commands.
Table C-2. AI-DVM Shortcut Keys with Touchscreen Disabled
CommandShortcut KeysDescription
Navigating GPS
Status Software
Enable/Disable Read
PPS from Internal
GPS
Apply / Cancel
Changes
<Tab>, <Enter>, and
<Up/Down Arrows>
<P>Move cursor to Read PPS from
Ok / CancelMove cursor to <Ok> or <Cancel>
Press <Tab> to move cursor from
one field to another.
Press <Enter> to open or close a
drop-down list.
Press <Up/Down Arrows> to move
cursor in a drop-down list; press
<Enter> to select an option in a
drop-down list.
Internal GPS in Options and then
press <P> to enable or disable the
option.
and then press <Enter>. Ok
applies changes, Cancel cancels
changes.