Junger Audio C8234 User Manual

digital audio modular processing system
4 MIC / Line inputs
features
• 4 high quality MIC / Line inputs
• 24bit sigma-delta A/D-converter
• Sample rates up to 96kHz
• Digitally controlled gain 0..+65dB
• Max. line input level +20dBu
• Pad attenuation -10dB (Line)
• Floating balanced analog inputs
• Electrical isolation between channels
• 48V phantom power
block diagram
1 2
-
3
In 1
4 5 6 7
+
8
AD1
C8000
C8234
Audio Bus
S01...S32
CAN BUS
1 2
-
3 4
In 2
In 3
In 4
Jünger Audio Studiotechnik GmbH Justus-von-Liebig-Strasse 7 D -12489 Berlin Germany
5 6 7
+
8
1 2
-
3 4 5 6 7
+
8
1 2
-
3 4 5 6 7
+
8
AD2
AD3
AD4
MUX
MUX
to C8000
In 1/2
bus routing
In 3/4
CAN
CTRL
phone: +49-30-677721-0 fax: +49-30-677721-46 info@junger-audio.com www.junger-audio.com
1/10
digital audio modular processing system
C8000
4 MIC / Line inputs
technical specifications
Dynamic range: 110 dB (RMS) digital FS
THD+N: < 0.09% @ max. input level
Equivalent Input noise:
Mic 126.5 dB (RMS) @ 200 Ohm, 40 dB gain
Max. input level: + 15 dBu (Mic)
+ 22 dBu (Line)
Frequency response: 10 Hz (-3 dB)...20 kHz (-0,5 dB) (SR=48kHz) 10 Hz (-3 dB)...40 kHz (-0,5 dB) (SR=96kHz)
Crosstalk: > 90 dB (20kHz)
CMR: > 80 dB (20kHz)
Input impedance:
MIC 9k, differential Line 20k, differential
Gain: 0dB, +10dB to +65 dB in 1dB steps
Digital output:
resolution 24bit sample rate 32...96 kHz
Input connector
RJ-45 4,5 & shield = ground
3=live, 6=return
Back plane connector:
ref. to DIN41612 64pin, a+b, male
Power supply +5V DC
consumption appr. 1300 mA
Dimensions 3 RU, 8 HP, 160 mm in depth
C8234
Jünger Audio Studiotechnik GmbH Justus-von-Liebig-Strasse 7 D -12489 Berlin Germany
phone: +49-30-677721-0 fax: +49-30-677721-46 info@junger-audio.com www.junger-audio.com
2/10
digital audio modular processing system
4 MIC / Line inputs
installation
C8000
C8234
Set the CAN rotary encoder to an address, which is not in use by an other module
of a C8000 frame (for details regarding CAN addressing, see C8000 system manual).
Pressing the INIT button during power up will initialize the module parameters to factory default values.
Jünger Audio Studiotechnik GmbH Justus-von-Liebig-Strasse 7 D -12489 Berlin Germany
phone: +49-30-677721-0 fax: +49-30-677721-46 info@junger-audio.com www.junger-audio.com
3/10