Jung ULZ 1215 REG Operating Instructions Manual

Universal amplifier for rail mounting 200-500 W
Light Management
Universal amplifier for rail mounting 200-500 W
Art. No. ULZ 1215 REG
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load is not electrically isolated from the mains even when the device is switched off.
Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load.
Fire hazard. For operation with inductive transformers, each transformer must be fused on the primary side in accordance with the manufacturer's instructions. Only safety transformers according to EN 61558-2-6 may be used.
A minimum power of 10 kVA is required for operation on isolating transformer networks. Otherwise it is not ensured that the dimmer will correctly recognise the dimming principle suitable for the load. Device can be damaged.
These instructions are an integral part of the product, and must remain with the end customer.
2 Device components
Figure 1: Device components
(1) Power booster (2) LED on/off: power booster on/off
3 Function
Intended use
- Power enhancement for the Tronic or universal dimmers contained in the reference list
(see section Technical data)
- Switching and dimming of incandescent lamps, HV halogen lamps and Tronic or dimmable
inductive transformers with halogen lamps.
1/7
82557263 J:0082557263
27.02.2013
- Suitable for mixed operation up to the specified output (see section Technical data)
- Installation in distribution boxes on DIN rail according to EN 60715
i Lighting systems with an power of more than 1000 W/VA are professional applications. i No mixed operation of Tronic and inductive transformers. i Operation with HV LED lamps is not possible.
Product characteristics
- Connection of several power boosters to a single dimmer
- The total power of the connected loads is divided between the dimmer and power boosters.
- Power is supplied to the connected loads via a common power cable
- Operation using upstream dimmer
- Electronic over-temperature protection
i Flickering of the connected lamps due to undershoot of the specified minimum load or
through centralised pulses from the power stations. This does not represent any defect in the device.
i Brightness differences between the lighting on a dimmer without powerpower booster and
a dimmer with power booster are possible.
4 Information for electrically skilled persons
4.1 Fitting and electrical connection
DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Fitting and connecting the power booster
i To prevent overheating, maintain a distance of 1 module when operating multiple dimmers
or power units within the same control cabinet.
i The terminals must be at the top. o Snap power booster onto DIN rail.
CAUTION! Destruction of the devices when connected to the wrong outer conductor. The dimmer and power boosters will be destroyed. Connect all devices to the same outer conductor.
2/7
82557263 J:0082557263
27.02.2013
Light Management
Universal amplifier for rail mounting 200-500 W
Figure 2: Connection diagram with RMD dimmer
Figure 3: Connection diagram with FM dimmer
3/7
82557263 J:0082557263
27.02.2013
Light Management
Universal amplifier for rail mounting 200-500 W