Jung TR 231 Series, TR 236 Series, TR 246 Series, TR 241 Series Operating Instructions Manual

Temperature Management Room temperature controller
Ref.-no.: TR..231.., TR..241..,
TR..236.., TR..246..
Stand: Sep-11
24091002
Operating Instructions Room temperature controller
1. Area of application
The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc.
Safety instructions Electrical equipment may only be installed and fitted by qualified
electricians while observing the current accident prevention regulations. A relative air humidity of max. 95% may not be exceeded. Avoid any moisture condensation. Non-observance of the safety warnings or installation instructions may damage the device, cause a fire or other hazards.
2. Installation
Notes:
Mount the room temperature controller on an internal wall opposite the heat source if possible.
Do not mount the room temperature controller on outside walls.
Avoid draughts from windows and doors.
Ensure that the normal air circulation in the room reaches the
controller without any obstacles.
External heat sources influence the accuracy of the controller. Avoid direct sunlight and do not place heat-emitting devices in the vicinity of the room temperature controller (heaters, lamps, etc.).
Dimmers also generate heat. If a controller is installed in a common switch frame with a dimmer, the distance between them should be as great as possible. When arranging them vertically, the controller must be installed underneath the dimmer.
Mounting height: approx. 1.5 m above the floor. Mounted in a switch box in accordance with DIN 49 073.
Temperature Management Room temperature controller
Ref.-no.: TR..231.., TR..241..,
TR..236.., TR..246..
2
Fig. c
3. Connection
1. Carry out the electrical connection according to the respective wiring diagram (Fig. (2) or Fig. (3).
Note:
Ensure that the neutral conductor N is connected to terminal N. Considerable fluctuations in temperature may otherwise occur. Conductor cross-section: 1 to 2.5 mm2 solid conductor.
Symbols used in the wiring diagram:
L = L conductor N = N- conductor
= Connection for clock signal to reduce temperature
= Heating
= Cooling RF = Resistor for thermal feedback TA = Resistor for night reduction of room temperature
2. Clip the rocker (A in Fig.
c
) on the switch in the flush insert.
3. Place the center plate together with the frame on the flush insert. The center plate must snap in place in the top left of the housing base.
4. Tighten the screw (B).
5. Clip on the setting knob (C).