KNX Binary input
Ref.-nr.: 2114 REG, 2118 REG,
2126 REG
KNX
instabus EIB connection : instabus connecting terminal
Binary input connection : screw-type terminals
∅ for binary inputs 230 V : 0,75 to 4 mm² single-wire or
2 x 1,5 to 2,5 mm² single-wire
0,75 to 4 mm² stranded wire
without ferrule or
0,75 to 2,5 mm² stranded wire
with ferrule
∅ for binary inputs 24 V : 0,2 to 4 mm² single-wire or
2 x 0,2 to 2,5 mm² single-wire
0,75 to 4 mm² stranded wire
without ferrule or
0,5 to 2,5 mm² stranded wire
with ferrule
General specification of inputs:
Minimum signal duration
for pulse counting : 200 ms at 5 Hz signal clock
with mark-to-space ratio 1:1
Signal delay (software-independent)
rising edge : ca. 2 ms
falling edge : ca. 40 ms
Length of input line : max. 100 m (unshielded)
Universal binary input 4-channel 230 V / 8-channel 230 V:
Signaalspanning : 110 tot 230 V AC, 50 / 60 Hz
Ingangsstroom / kanaal : ca. 7 mA bij 230 V AC
Signaalniveau
‘0’-signaal : 0 tot 70 V AC
‘1’-signaal : 90 tot 253 V AC
Universal binary input 6-channel 24 V:
Signal voltage : 8 to 42 V AC/DC
Input current / channel : appr. 4 mA at 24 V AC/DC
Signal level
‘0’ signal : 0 to 1,8 V AC / -42 to +1,8 V DC
‘1’ signal : 8 to 42 V AC/DC
Technical specifications subject to change