i To ensure fault-free operation, do not combine the device with other DALI controllers.
Behaviour after a mains voltage failure
When the mains voltage returns, the lighting is switched to that switching state in which it was
located before the mains voltage failed. If the lighting was switched on, then the switch-on
brightness is set.
4 Operation
i Operation can take place from multiple control sections and always applies to all the
connected subscribers, broadcast.
Switch light
o Press the control knob.
Adjust the brightness
o Turn the control knob.
Save switch-on brightness
When the lighting is switched on, that brightness is set which existed the last time it was
switched off. If the lighting is not always to be switched on with the same brightness, then this
can be saved as a switch-on brightness.
o Switch on light.
o Set the required brightness.
o Press the control knob briefly twice in succession, double-click.
The lighting briefly switches to maximum brightly twice. The switch-on brightness is saved.
i If the lighting switches off after the double-click, then the time between the first and second
presses was too long.
Delete switch-on brightness
o Switch the light off.
o Press the control knob briefly twice in succession, double-click.
After about 2 seconds the lighting switches to maximum brightness.
The switch-on brightness has been deleted.
5 Information for qualified electricians
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disconnect all the
corresponding circuit breakers. Cover up live parts in the working environment.
2/4
82563213
J:0082563213
06.05.2010
Power DALI potentiometer insert