User manual

1 Safety instructions

Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect before carrying out work on the devise or load. In
so doing, take all the circuit breakers into account, which support dangerous voltages to the device and or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load is not electrically isolated from the mains even when the device is switched off.
Do not press on the sensor window. Device can be damaged. The device is not suitable for use as a burglar alarm or other alarm. These instructions are an integral part of the product, and must remain with the end customer.

2 Device components

Figure1: Motion detector cover 1.10m
32599713 17.08.2018 J0082599713
1 / 15
Page 2
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Figure2: Motion detector cover 2.20m
(1) FMinsert (2) Frame (3) Motion detector cover (4) Sensor window and status LED (5) Switch (6) Button (7) Button
0 AUTO I ON OFF
Status LED
Red LED lights up Self-test
Red LED flashes 3 s on / 3 s off Alarm function active
Red LED flashes 0.5 s on / 0.5 s off Alarm was triggered
Red LED flashes three times followed by a 1 s pause
Cover was previously connected to another in­sert
Yellow LED lights up "Continuous off" or "Off for 0.5 - 5 hours" func-
tion active
Yellow LED flashes Presence simulation active
Green LED lights up "Continuous on" or "On for 0.5 - 5 hours" func-
tion active
Blue LED lights up Device is coupled with a mobile end device
and active app
Blue LED flashes 0.5 s on / 0.5 s off Bluetooth coupling mode active

3 Intended use

Automatic switching of lighting depending on the heat motion and ambient brightness – Operation with flush-mounted insert for dimming or switching or 3-wire extension from LB
management
Wall installation on flush-mounted insert
32599713 17.08.2018 J0082599713
2 / 15
Page 3
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Product characteristics
Functions directly on the cover – Extension of the detection area in combination with 3-wire extension – Continuous on, Continuous off – Operation with 2-wire or 3-wire extension, rotary dimmer extension or push-button – Dimming insert can be dimmed via extension – Resetting to factory setting
Motion detector cover 1.10m – Screen for limiting the detection area
Functions via app – Setting the brightness threshold – Adjusting the sensitivity of the PIR sensors – Setting the run-on time – Continuous on, Continuous off – On or off for 0.5 - 5 hours – Switch-off warning – Dynamic run-on time – Presence simulation – Alarm function – Timer function – Test operation
In combination with a switch insert – Short time operation
In combination with a dimming insert – Switch on with last saved brightness or saved switch-on brightness – Hotel function – Night light function
Automatic operation
The device detects heat motions of people, animals and objects. – The light is switched on if a person enters the detection field and the brightness threshold
is below the set brightness threshold. – The run-on time restarts with each detected motion. – The light is switched off, if:
no more movement is detected in the detection field and the run-on time has elapsed or
the ambient light is too bright and the run-on time has elapsed. To avoid any switch-on caused by a cooling illuminant, no movement signals are evaluated for a
brief lockout time after switching off. The motion detector adjusts itself to the ambient conditions to keep the time as short as possible.
Behaviour after a mains voltage failure
After mains voltage return, the device performs a self-test for a maximum of 20 seconds. After the self-test has been completed, the device is ready for operation.
If the red status LED flashes three times at repeated intervals, the cover was previously connected to another insert. To enable the function again, either place the cover onto the respective insert or press the switch (5) within 10 seconds from AUTO position to the OFF position for motion detector cover 1.10m, and the OFF button for more than 4 seconds for motion detector cover 2.20m.
The following applies during the self-test: – The red status LED is illuminated. – The load is switched off.
32599713 17.08.2018 J0082599713
3 / 15
Page 4
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Movements are not detected – The device can be operated via extensions

4 Commissioning

Install app on a mobile end device
Requirement for operation via app is a mobile end device with Bluetooth interface, running the Android operating system (from version Version 5.0) or iOS (from version 10).
Download and install the Clever Config app from the iTunes App Store (iOS) or Google
Play Store (Android).
Couple mobile end devices via Bluetooth
Precondition: insert and cover must be ready for operation. The mobile end device is located close to the cover.
Activate coupling mode motion detector cover 1.10m: Move the switch from position
AUTO ■ Cover the lens for at least 4 seconds within 1 minute. ■ Activate coupling mode motion detector cover 2.20m: Press the button ON (7) for more
than 4 seconds.
The blue LED flashes. The coupling mode is active for 1 minute.
to position I (5).
Start the app and search for device to be coupled.
Cover is coupled with the end device and shown in the app.
The coupling mode is automatically exited after successful coupling. The blue LED lights
up to confirm an active connection.
A maximum of 8 mobile end devices can be coupled with a cover. When coupling the 9th
device, the oldest device will be deleted.

5 Operation

Operation using 2-wire or 3-wire extension with button cover or push-button
Multiple extensions can be combined with each other. All operations described here are also possible via the app. Operation with the rotary dimmer extension is described in the rotary dim­mer extension instructions.
Switching on light for the duration of the run-on time ■ Press the button cover or push-button briefly.
If the button cover or push-button is pressed again in the switched-on state, the run-on
time is restarted. In combination with a dimming insert, switch-on brightness is switched
on again.
Short-time operation: When pressed, pulses are generated approx. every 3 seconds for 1
minute. Exception for 3-wire extension: only one pulse is generated.
Adjust the brightness, only in combination with dimming insert ■ Long press on button cover at the top or bottom or push-button.
Save switch-on brightness, only in combination with dimming insert ■ Adjust the brightness.
Press the button cover over entire surface for longer than 4 seconds.
An push-button cannot be used to save the switch-on brightness.
Delete switch-on brightness, only in combination with dimming insert ■ Press the button cover briefly: Light switches on at the saved switch-on brightness.
Press the button cover over the entire surface for longer than 4 seconds: Switch-on
brightness is deleted. Switching on takes place at the last brightness value set.
32599713 17.08.2018 J0082599713
4 / 15
Page 5
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
A push-button cannot be used to delete the switch-on brightness.
Operation on the cover
With the switch or the two buttons you can switch between automatic operation, continuous on and continuous off.
(6).
OFF
.
Motion detector cover 1.10m: Move the switch (5) to position ON or ■ Motion detector cover 2.20m: Press the button ON (7) or
OFF
Continuous on function green LED is illuminated or continuous off function yellow LED is
illuminated.
In order to switch on automatic operation again, put the switch (5) back to the centre posi-
tion for motion detector cover 1.10m, and the ON button (7) or OFF button (6) for motion
detector cover 2.20m. Green or yellow LED goes out.

6 Information for electrically skilled persons

DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Motion detection
The detection of heat sources through a motion detector and thus the extent of the detection field is influenced by the following criteria:
Geometry of the detection field, assembly height and set sensitivity (Figure 3) up to (Figure 10) Direction of movement: If motion detector passes tangentially, this results in a heat signal which
can be evaluated well. If movement is radial to the sensor, the heat signal is smaller and thus harder to evaluate, resulting in a smaller range.
The following specifications on the extent of the detection field are general guide values.
Discrepancies can occur depending on the installation environment and the intensity of
the heat motion.
Motion detector cover 1.10 m detection field and range
Figure3: Motion detector cover 1.10 m detection field and installation height
32599713 17.08.2018 J0082599713
5 / 15
Page 6
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Figure4: Range with tangential direction of motion motion detector cover 1.10 m
1 25% sensitivity 2 50% sensitivity 3 75% sensitivity 4 100% sensitivity
Figure5: Range with radial direction of motion motion detector cover 1.10 m
1 25% sensitivity 2 50% sensitivity 3 75% sensitivity 4 100% sensitivity
32599713 17.08.2018 J0082599713
6 / 15
Page 7
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Motion detector cover 2.20 m detection field and range
Figure6: Motion detector cover 2.20 m detection field and installation height
Figure7: Range with tangential direction of motion motion detector cover 2.20 m, mounting
height 2.20 m
1 25% sensitivity 2 50% sensitivity 3 75% sensitivity 4 100% sensitivity
Figure8: Range with radial direction of motion motion detector cover 2.20 m, mounting height
2.20 m
1 25% sensitivity 2 50% sensitivity
32599713 17.08.2018 J0082599713
7 / 15
Page 8
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
3 75% sensitivity 4 100% sensitivity
Figure9: Range with tangential direction of motion motion detector cover 2.20 m, mounting
height 1.10 m
1 25% sensitivity 2 50% sensitivity 3 75% sensitivity 4 100% sensitivity
Figure10: Range with radial direction of motion motion detector cover 2.20 m, mounting height
1.10 m
1 25% sensitivity 2 50% sensitivity 3 75% sensitivity 4 100% sensitivity
Selecting installation location ■ Select a vibration-free installation location. Vibrations can lead to unwanted switching.
To achieve optimum range, choose an installation location that is tangential to the direc-
tion of motion. ■ Avoid interference sources in the detection area. Interference sources can trigger the mo-
tion detector, e.g. heat sources such as heating units, outlets from ventilation openings or
air conditioners, copiers, printers, coffee machines, draughty doorways, animals etc.
32599713 17.08.2018 J0082599713
8 / 15
Page 9
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Fitting the cover ■ Connecting and mounting the FM insert properly (see flush-mounted insert instructions).
Further installation steps are necessary to ensure the degree of protection IP 44 (see
Seal set instructions). ■ Fit the cover with frame on the flush-mounted insert.
Expanding the detection field
To expand the detection field, connect a 3-wire extension with presence or motion detector cover. The main device also evaluates signals of the extension and, if necessary, switches the lighting on.
Limiting the detection field
The detection field can also be limited by reducing the sensitivity or switching off a sensor. Alternatively, the detection area for motion detector cover 1.10m can be limited with a panel
(Figure 11).
Figure11: Limiting detection area for motion detector cover 1.10m
Mounting the panel
Figure12: Dismounting of cover series CD/LS
Figure13: Dismounting of design cover series CD/LS
32599713 17.08.2018 J0082599713
9 / 15
Page 10
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Figure14: Mounting of panel series CD/LS and A
Series CD, LS ■ Remove switch (5) (Figure 12). ■ Use a screwdriver to carefully remove the design cover (Figure 13). ■ Mount the cover for the left or right side of the device (Figure 14).
Series A: ■ Mount the cover from the front on the left or right side of the device (Figure 14).
Locking the switch
Figure15: Locking the switch
The switch can be mechanically locked to the
AUTO
position as required. Use the provided
screw (9) for this ■ Remove the cover from the switch (5) (Figure 12). ■ Turn screw (9) in the hole (8) (Figure 15).
Configuring device settings
Settings are configured via the app Default settings
Function Setting
Operating function Automatic operation
Sensitivity 100 %
Detection angle 180°
Brightness threshold 10lux
Run-on time 2 minutes
Supplementary function switched-off
Checking detection field
Any motions detected are displayed in the app and by the red LED. The lighting is switched on for approx. 1 second. If the light is not to be switched dependent on motion, the Continuous on or Continuous off function should also be activated.
32599713 17.08.2018 J0082599713
10 / 15
Page 11
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
3-wire extension: detected motions are sent to the main device. This switches according
to its settings. ■ Activate the walking test via the app and pace off the detection field. The function is auto-
matically terminated after approx 5 minutes.
Restoring the device to factory settings
After resetting the device to the default setting, it has to be removed from the app. On iOS
equipment, the device also has to be removed from the list of paired Bluetooth devices
(Settings/Bluetooth). Otherwise, re-pairing will not be possible. Motion detector cover 1.10m
Briefly disconnect the device from the mains voltage.
Red LED lights up, self-test runs.
Within 1 minute after switching on the mains voltage, move the switch (5) from position
AUTO
to position 0.
After approx. 20 seconds, the red LED flashes quickly.
Within 10 seconds, move the switch (5) from position 0 to position
sition 0 and to position
AUTO
once again.
AUTO
, and back to po-
The red LED flashes more slowly, device is reset to the factory settings and restarts.
Motion detector cover 2.20m ■ Briefly disconnect the device from the mains voltage.
Red LED lights up, self-test runs.
Within 1 minute after switching on the mains voltage, press the
OFF
button (6) for more
than 20 seconds.
After approx. 20 seconds, the red LED flashes quickly.
Within 10 seconds, release the button and actuate it briefly once again.
The red LED flashes more slowly, device is reset to the factory settings and restarts.

7 Technical data

Ambient temperature -20 ... +45 °C Storage/transport temperature -25 ... +70 °C Degree of protection IP20 Brightness setting approx. 5 ... 500 lx and day operation Sensitivity 0, 25, 50, 75, 100% Run-on time approx. 10 s ... 60 min Installation height Art. no. ..17181.. 1.10 m Art. no. ..17281.. 1.10 m / 2.20 m Detection angle 180 ° Radio frequency 2.402 ... 2.480 GHz Transmission capacity max. 2.5 mW, Class 2 Transmitting range typ. 10 m

8 Parameter list

Adjustable parameter list via app
Depending on the insert, the following parameters can be changed with the app.
32599713 17.08.2018 J0082599713
11 / 15
Page 12
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Settings for switch and dimming inserts
Parameters Setting options, default set-
ting
Operating func-
Automatic on, off
tion
Default setting: automatic
Limiting the
On, Off
length
Default setting: Off
PIR A - B 0, 25, 50, 75, 100 %
Default setting: 100%
Walking test On, Off
Default setting: Off
Explanation
Automatic: The load is switched depending on motion and brightness.
On or off: The load is permanently switched on or off.
On or off for 0.5 - 5 hours: The load is switched on or off for the specified time.
Time for which the load remains on or off when the "On" or "Off" function is activated. Afterwards, the device is in automatic mode. The time can be set in the range of 0.5 ­5 hours. Default setting: 2 h
Individually adjust the sensitivity in 5 steps for each sensor A–C.
To restrict the detection field, switch off indi­vidual sensors. To do this, set the sensitivity to 0 %.
Function for checking the detection field. The function automatically terminates after 5 minutes.
Switch-on threshold
Motion detector: 5… 500 lx and day operation
Default setting: 10 lx
Day mode On, Off
Default setting: Off
Run-on time 10 s ... 60 min
Default setting: 2 min
Dynamic run-on
On, Off
time
Default setting: Off
Starting presence
On, Off
simulation
Default setting: Off
The load is switched on if the brightness value falls below this value and if motion is detected.
In the setting
day operation
the device oper-
ates independently of the brightness.
The load remains switched on for this time, even if no more motion is detected or the am­bient light is bright enough.
The device automatically determines a run-on time within specified limits and dynamically from detected motion. In so doing, the run-on time is increased if presence continues or de­creased if absence is detected. The maximum run-on time is the set run-on time. The shortest run-on time is 10 seconds. For run-on times times from 5 minutes, the brief presence detection function is also active.
The function can only be activated after more than 24 hours of time was saved. In automatic mode, the times at which the lighting was switched on are continuously saved. A max­imum of 60 switching operations are saved over a period of 24 hours. If more switching operations take place, the oldest ones are overwritten respectively. If the presence simu­lation is activated, the lighting is switched on
32599713 17.08.2018 J0082599713
12 / 15
Page 13
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Parameters Setting options, default set-
ting
Alarm function On, Off
Default setting: Off
Time controller 16 switch points
Default setting: none
Explanation
at the saved times depending on the bright­ness. Switch-off takes place after the run-on time has elapsed. Detected motions prolong the run-on time or the light is switched on de­pending on brightness. Times are not saved. The dynamic run-on time is not taken into ac­count.
This function is used to monitor an area for un­authorised access during absence. If this is the case, the lighting flashes (1 second on, 1 second off) for the duration of the run-on time. In addition, a message is sent via the Bluetooth interface. When motions are detec­ted, the run-on time is restarted.
With this function it is possible to automatically switch on functions such as night light or hotel function for a defined period of time. A weekly timer is available for this purpose. The timer updates itself with every Bluetooth connection to a mobile end device. One function can be switched on or off per switch point. A time and one or more weekdays are assigned to each switch point.
Settings only for switch inserts
Parameters Setting options,
default setting
Pulse operation On, Off
Default setting: Off
Switch-off warn-
On, Off
ing
Default setting: Off
Settings only for dimming inserts
Parameters Setting options,
default setting
Switch-off warn-
On, Off
ing
Default setting: Off
Explanation
If motion occurs, then a short pulse of approx.
0.5 seconds is triggered depending on the brightness. The pulse is repeated approx. every 3 seconds as long as motions are detected.
If the switch-off warning is activated, the light is not switched off immediately after the run-on time has elapsed. Triple flashing at an interval of 10 seconds shows that the light will be switched off soon. The run­on time is thereby prolonged by approx. 30 seconds. If motion is detected during the switch-off warning, then the run-on time is restarted and the light remains on.
Explanation
If the switch-off warning is activated, the light is not switched off immediately after the run-on time has elapsed. The light is first dimmed to minimum bright­ness within 30 seconds. The run-on time is thereby pro­longed by approx. 30 seconds. If motion is detected dur­ing the switch-off warning, then the run-on time is re­started and the light switches back to the switch-on brightness.
32599713 17.08.2018 J0082599713
13 / 15
Page 14
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m
Parameters Setting options,
default setting
Switch-on bright-
5 ... 100 %
ness
Default setting: 100%
Switching on to
On, Off
the last value
Default setting: Off
Hotel function On, Off
Default setting: Off
Brightness hotel
5 ... 100 %
function
Default setting: 20 % of the max­imum brightness
Night light func-
On, Off
tion
Default setting: Off
Explanation
The light is switched on to a stored brightness.
When it is switched on, the light is switched on to the last brightness value set.
When the function is activated, it switches between two brightness values. If motions are detected, the light is switched to the switch-on brightness.
Brightness to which the light is switched when the hotel function is activated and the run-on time has elapsed. It is a percentage of the maximum brightness.
When the function is activated, the light is not switched on to the switch-on brightness but to a defined bright­ness value when motion is detected.
Brightness night light function
5 ... 100 %
Default setting:
Brightness to which the light is switched on when the night light function is switched on. It is a percentage of
the maximum brightness. 20 % of the max­imum brightness

9 Troubleshooting

Motion detector does not switch on
Cause 1: The ambient brightness is greater than the adjusted brightness threshold.
Set the brightness threshold via app.
Cause 2: Motion detector does not detect any motions.
Check detection area for any obstacles. Adjust the sensitivity of the sensors via app
Motion detector switches on without motion
Cause: Motion detector detects heat motions.
Pay attention to interference sources such as heaters, fans, air-conditioners and cooling luminaires in the detection field.
Motion detector switches off despite motion
Cause: The ambient light is too bright and the switch-off threshold was exceeded.
Set the brightness threshold via app.
Motion detector does not switch off after the set run-on time has elapsed
Cause: Motion detector detects motions constantly.
Pay attention to interference sources such as heaters, fans and air-conditioners in the de­tection field.
32599713 17.08.2018 J0082599713
14 / 15
Page 15
LB management
Universal automatic switch 1.1 m, Universal automatic switch 2.2 m

10 Accessories

Sealing kit for automatic switch 2.20 m Art.-no.AS..50DS

11 Conformity

Albrecht Jung GmbH & Co. KG hereby declares that the radio system type art. no. ..17181.. and ..17281.. meets the directive 2014/53/EU. You can find the full article number on the device. The complete text of the EU Declaration of Conformity is available under the Internet address: www.jung.de/ce

12 Warranty

The warranty follows about the specialty store in between the legal framework as provided for by law
ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY
Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-2 04 kundencenter@jung.de www.jung.de
32599713 17.08.2018 J0082599713
15 / 15
Loading...