Electrical devices may only be mounted and connected by electrically skilled
persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. In so doing, take all the circuit breakers into account, which support dangerous
voltages to the device and or load.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Insert
(2) Frame
(3a) Blind/shutter up / light on, brighter
(3b) Blind/shutter down / light off, darker
(4a) Disabling function
(4b) Memory function
32595313
J0082595313
1/4
01.03.2018
Page 2
LB Management
Universal centre plate
(5) Function LED
Red = Disabling function active
Green = Memory function active
(6) Status LED, green
On = Blind/shutter activated / light switched on
3 Function
Intended use
-Manual and time-controlled operation of Venetian blinds, shutters, awnings or lighting
-Operation of switching, dimming or Venetian blind insert or 3-wire extension from LB
management
Product characteristics
-Activation of blind/shutters, with Venetian blind insert
-Switching and dimming of lighting, with switching or dimming insert
-Ventilation position of the blind/shutter can be saved, with Venetian blind insert
-Switch-on brightness of lighting can be saved, with dimming insert
-Disabling function
-2 switching times can be saved, which are repeated in a 24-hour cycle
Behaviour after a mains voltage failure
-All saved switching times have been deleted.
-The load is switched off.
-Ventilation position and switch-on brightness remain intact.
4 Operation of Venetian blind and shutters
Moving the blind/shutter
oPress button (3a) or (3b) for longer than one second.
The blind/shutter moves in the desired direction to the end position or stops when the
button is pressed again.
i If a ventilation position has been saved, the blind stops in the ventilation position when
moving down from the top end position (see Saving the ventilation position).
Adjusting the slats
oPress the button (3a) or (3b) for less than one second.
Saving the ventilation position
To save and execute the ventilation position, the Venetian blind/shutter must be moved to the
upper end position and the status LEDs (6) switch off automatically after 2 minutes.
oFrom the top end position, press the button (3b) for longer than second.
The blind/shutter moves in the lower end position direction.
oPress and hold down the button (3a) and (3b).
The blind/shutter remains stopped, but continues to move after 4 seconds.
oAs soon as the desired ventilation position has been reached, release the buttons and
press the button (3a) within the next 4 seconds.
The ventilation position is saved. The blind/shutter moves back to the upper end position.
i If the ventilation position is saved again, the old value is overwritten.
5 Operation of lighting
Switch light
oPress button (3a) or (3b) for less than 0.4 seconds.
i With a dimming insert, the light switches to the brightness that was last set or a saved
brightness.
32595313
J0082595313
2/4
01.03.2018
Page 3
LB Management
Universal centre plate
Switch light on with minimum brightness
oLong press on button (3b).
Adjust the brightness
oLong press on button (3a) or (3b).
Save switch-on brightness
oAdjust the brightness.
oPress buttons (3a) and (3b) for longer than 4 seconds.
Delete switch-on brightness
oPress button (3) briefly: Light switches on at the saved switch-on brightness.
oPress buttons (3a) and (3b) for longer than 4 seconds.
The switch-on brightness has been deleted.
Switching on takes place at the last brightness value set.
6 Activate functions
Saving switching times - Memory operation
oIn addition to normal operation with the button (3a) or (3b), press the button (4b) for longer
than one second.
The insert switches and the switching time is saved.
The device switches to memory operation. The function LED (5) turns continuously green.
Saved switching operations are repeated in a 24-hour cycle.
i An upward and downward movement time, or on and off time, can be saved. The old
switching time will be replaced if a new one is saved.
i To delete all the times, press the button (4b) for longer than 20 seconds until the function
LED (5) lights up for a second time.
Activating / deactivating memory operation
oPress the button (4b) for longer than 4 seconds.
In memory operation, the function LED (5) turns continuously green.
i It is only possible to switch to memory operation if at least one switching time has been
saved.
Activating / deactivating the disabling function
The disabling function disables extension operation and deactivates memory operation. Manual
operation using the buttons (3a) and (3b) continues to be possible.
i With Venetian blinds, extension operation in the "UP" direction (wind alarm) continuous to
be possible.
oPress the button (4a) for longer than 4 seconds.
The function LED (5) is red for as long as the disabling function is active.
Activating / deactivating night mode
In night mode, the status and function LEDs are not permanently lit, but only for 5 seconds after
a button is pressed.
oPress the buttons (4a) and (4b) for longer than 4 seconds.
Night mode is activated: The function LED turns red for 3 seconds.
Night mode is deactivated: The function LED turns green for 3 seconds.
32595313
J0082595313
3/4
01.03.2018
Page 4
LB Management
Universal centre plate
7 Information for electrically skilled persons
7.1 Fitting and electrical connection
DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Fitting the device
Switching, dimming or Venetian blind insert are mounted and connected properly (see
instructions of the relevant inserts).
oFit the frame and cover on the insert.
oSwitch on mains voltage.
i If the status LED flashes three times at repeated intervals, the cover was previously
connected to an insert of another unit.
To enable operation again, either place the cover onto the correct insert or press buttons
(3a) and (3b) for longer than 4 seconds.
8 Appendix
8.1 Technical data
Ambient temperature-5 ... +45 °C
Storage/transport temperature-20 ... +70 °C
Data according to EN 60730-1
Action1.B.S.T
Degree of soiling2
Meas. surge vol.4000V
8.2 Warranty
The warranty follows about the specialty store in between the legal framework as provided for
by law.