Jung 1701 SE User guide

Operating instructions
Relay switch insert 1-channel Art. no. 1701SE
ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY
Telefon: +49 2355 806-0 Telefax: +49 2355 806-204 kundencenter@jung.de www.jung.de
19.10.2022
82597453 J0082597453
Relay switch insert 1-channel

Table of Contents

1 Safety instructions.............................................................................................................3
2 Intended use .....................................................................................................................3
3 Operation ..........................................................................................................................3
4 Information for electrically skilled persons ........................................................................4
5 Technical data...................................................................................................................6
6 Warranty............................................................................................................................7
82597453 19.10.2022 J0082597453
2 / 7
Relay switch insert 1-channel

1 Safety instructions

Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the device or load. In so doing, take all the circuit breakers into account, which support danger­ous voltages to the device and or load.
This manual is an integral part of the product, and must remain with the end cus­tomer.

2 Intended use

Switching of lighting and motors
Control of electric underfloor heating systems and electrothermal valve drives
in combination with a room thermostat cover or KNX RF push-button
Operation with suitable cover from the systems LB management, JUNG
HOME, eNet and KNX RF
Mounting in appliance box with dimensions according to DIN 49073
Product characteristics
Connection of extensions possible
Settable time functions

3 Operation

These instructions describe operation with a LB Management push-button 1-gang. Operation with a different cover is described in the instructions for the cover in ques­tion. The operation on the main device and the 2-wire extension is identical.
Switching the load
Press the operating cover.
The load switches on or off.
Time function
Different times can be set for the automatic switching-off of the load. The time func­tion starts as soon as the output is switched on. To terminate the time function pre­maturely, switch off the output manually.
The time function cannot be restarted by pressing again.
82597453 19.10.2022 J0082597453
3 / 7
Relay switch insert 1-channel

4 Information for electrically skilled persons

DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Connecting and fitting the device
Image1: Connection diagram with optional extensions
Image2: Terminal-specific cable cross-section
Connect the switch insert (2) according to the connection diagram
(see figure 1). Note clampable cable cross-sections (see figure 2).
Connect the 2-wire extension (3), the 3-wire extension (4) and as an option,
the push-button with NO contact (5).
82597453 19.10.2022 J0082597453
4 / 7
Relay switch insert 1-channel
Lit push-buttons must have a separate N terminal.
Fit the switch insert in the appliance box, the connection terminals must be at
the bottom.
Do not attach or replace the cover under voltage, otherwise this might cause a malfunction.
Attach the frame and the cover.
Switch on mains voltage.
The load can be switched by briefly pressing the
Setting the time function
Press the
TEST
button (1) for longer than 4 seconds.
LED lights up in the colour of the set run-on time, see table.
Release the
TEST
button (1) briefly and then press it repeatedly until the LED
lights up in the colour of the desired time.
The set time is automatically saved after 30 seconds or after pressing the TEST
button (1) for approx. 4 seconds. When the LED goes out, the saving
process was successful.
LED colour Set time green Function off white 1 minute blue 5 minutes yellow 30 minutes red 60 minutes
TEST
button (1).
Connecting and mounting the device as a room thermostat (see figure 3)
Recommended installation height: 1.50 m.
82597453 19.10.2022 J0082597453
5 / 7
Relay switch insert 1-channel
Image3: Connection diagram in combination with a room thermostat cover or KNX
(6) Switching contact for switching to cooling mode (7) Electric underfloor heating system (max. 16 A) or electrothermal valve
drives
If 230 V is applied to extension input 1, cooling mode is active.

5 Technical data

Rated voltage AC 230 V ~ Mains frequency 50 / 60 Hz Standby load depending on the cover approx. 0.1 ... 0.5W Switching current at 35 °C Ohmic 16 A (AC1) Motors 6 A
Connected load Incandescent lamps 2300 W
RF push-button
HV halogen lamps 2300 W Electronic transformers 1500 W Inductive transformers 1000 VA HV-LED lamps typ. 400 W Compact fluorescent lamps typ. 500 W Fluorescent lamps, uncompensated 1200 VA Capacitive load 920 VA (115 μF)
82597453 19.10.2022 J0082597453
6 / 7
Relay switch insert 1-channel
Power reduction per 5°C in excess of 35°C -5% when installed in wooden or dry construction walls -15% when installed in multiple combinations -20% Ambient temperature -25 ... +45 °C Storage/transport temperature -20 ... +70 °C
Number of extension units 2-wire, push-button unlimited 3-wire rotary extension 10

6 Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade.
ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY
Telefon: +49 2355 806-0 Telefax: +49 2355 806-204 kundencenter@jung.de www.jung.de
82597453 19.10.2022 J0082597453
7 / 7
Loading...