Compensating and connecting cables
■ compensating cables to EN 60584 and DIN 43 714
■ versions from -190 to +400 °C
■ sheath in PTFE, silicone, PVC or fiberglass
■ for single and twin thermocouples
Compensating cables (pages 1 to 3)
When measuring temperature with thermocouples, the cold junction temperature has to be
measured in addition to the thermal voltage. The cold junction temperature is acquired to the
terminals of the evaluation electronics. Since this may not necessarily be identical with the temperature inside the terminal head, the thermocouple has to be extended by means of a compensating cable (no compensating cable is necessary for thermocouples type B).
Up to 200 °C, compensating cables have the same thermoelectric properties as the
thermocouples themselves.
Connecting cables (pages 4 to 8)
Connecting cables with stranded copper conductors transmit the signals from resistance thermometers or transmitters, humidity sensors, and from transducers with a standard signal, to
measurement, control and recording devices.
Their construction depends on the local conditions (temperature, humidity and
mechanical stress).
Data Sheet 90.9735 (90.9723) Page 1/8
Note: Please state sales no. as per price sheet 90.9735 when ordering!
Compensating cables for dry areas
temperature range: -20 to +350 °C
Cross-section
2
in mm
Thermocouple Fe-Con L
2x 0.22 3.5 DIN 43714 2.50 00006479 ●
2x 0.50 4.3 DIN 43714 1.25 00017856 ●
4x 0.22 3.5 DIN 43714 2.50 00017857 ●
Thermocouple Fe-Con J
2x 0.22 3.5 EN 60584/Cl. 1 2.50 00341902 ●
2x 0.50 4.7 EN 60584/Cl. 1 1.25 00341903 ●
Thermocouple NiCr-Ni K
2x 0.50 4.0 EN 60584/Cl. 2 2.00 00017858 ●
4x 0.50 3.4 EN 60584/Cl. 2 2.00 00017860 ●
Thermocouple Pt10Rh-Pt S
2x 0.50 4.7 EN 60584/Cl. 2 0.20 00017859 ●
4x 0.50 3.5 EN 60584/Cl. 2 0.20 00017861 ●
Diameter
in mm
Color coding/
Class
Ω/m per
thermocouple
Part no.
2
1
2
1
1
1
2
1
2
● available from stock Item 1
1. with galvanized steel braiding
2. with stainless steel braiding
2010-03-08/00073425
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,
Postal address:
Phone: +49 661 6003-0
Fax: +49 661 6003-607
E-mail: mail@jumo.net
Internet: www.jumo.net
36039 Fulda, Germany
36035 Fulda, Germany
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow - Essex CM20 2DY, UK
Phone: +44 1279 63 55 33
Fax: +44 1279 63 52 62
E-mail: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-JUMO
Fax: 315-697-5867
E-mail: info@jumo.us
Internet: www.jumo.us
Compensating cables for dry and damp areas
temperature range: -50 to +180 °C
1-800-554-JUMO
Data Sheet 90.9735 (90.9723) Page 2/8
Cross-section
2
in mm
Diameter
in mm
Color coding/
Class
Ω/m per
thermocouple
Part no.
Thermocouple Fe-Con L
2x 0.50 4.7 DIN 43714 1.25 00017846 ●
4x 0.22 4.5 DIN 43714 2.50 00017848 ●
Thermocouple NiCr-Ni K
2x 0.22 3.2 EN 60584/Cl. 2 4.50 00052898 ●
2x 0.50 4.7 EN 60584/Cl. 2 2.00 00017847 ●
4x 0.22 4.7 EN 60584/Cl. 2 4.00 00017849 ●
● available from stock
Compensating cables for dry and damp areas
temperature range: -50 to +180 °C
Item 2
Cross-section
2
in mm
Diameter
in mm
Color coding/
Class
Ω/m per
thermocouple
Part no.
Thermocouple Fe-Con L
2x 1.50 6.5 DIN 43714 0.42 00017853 ●
Thermocouple NiCr-Ni K
2x 1.50 6.5 EN 60584/Cl. 2 0.70 00017854 ●
Thermocouple Pt10Rh-Pt S
2x 1.50 6.7 EN 60584/Cl. 2 0.07 00017855 ●
● available from stock
2010-03-08/00073425
Item 3
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,
Postal address:
Phone: +49 661 6003-0
Fax: +49 661 6003-607
E-mail: mail@jumo.net
Internet: www.jumo.net
36039 Fulda, Germany
36035 Fulda, Germany
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow - Essex CM20 2DY, UK
Phone: +44 1279 63 55 33
Fax: +44 1279 63 52 62
E-mail: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-JUMO
Fax: 315-697-5867
E-mail: info@jumo.us
Internet: www.jumo.us
Compensating cables for dry and damp areas
temperature range: +5 to +105 °C
1-800-554-JUMO
Data Sheet 90.9735 (90.9723) Page 3/8
Cross-section
2
in mm
Diameter
in mm
Color coding Ω/m per
thermocouple
Part no.
Thermocouple Fe-Con L
2x 0.22 3.7 DIN 43 714 2.50 00038959 ●
● available from stock
Compensating cables for dry areas
temperature range: -20 to +350 °C
Item 4
Cross-section
2
in mm
Ext. dimension
in mm
Color coding/
Class
Ω/m per
thermocouple
Part no.
Thermocouple Fe-Con L
2x 0.19 1.20 x 1.85 DIN 43714 3.20 00010497 ●
Thermocouple NiCr-Ni K
2x 0.19 1.20 x 2.00 EN 60584/Cl. 2 5.20 00060294 ●
● available from stock
2010-03-08/00073425