Compensating and connecting cables
compensating cables to EN 60584 and DIN 43 714
versions from -190 to +400 °C
sheath in PTFE, silicone, PVC or fiberglass
for single and twin thermocouples
Compensating cables (pages 1 to 3)
When measuring temperature with thermocouples, the cold junction temperature has to be measured in addition to the thermal voltage. The cold junction temperature is acquired to the terminals of the evaluation electronics. Since this may not necessarily be identical with the tem­perature inside the terminal head, the thermocouple has to be extended by means of a com­pensating cable (no compensating cable is necessary for thermocouples type B). Up to 200 °C, compensating cables have the same thermoelectric properties as the thermocouples themselves.
Connecting cables (pages 4 to 8)
Connecting cables with stranded copper conductors transmit the signals from resistance ther­mometers or transmitters, humidity sensors, and from transducers with a standard signal, to measurement, control and recording devices. Their construction depends on the local conditions (temperature, humidity and mechanical stress).
Data Sheet 90.9735 (90.9723) Page 1/8
Note: Please state sales no. as per price sheet 90.9735 when ordering!
Compensating cables for dry areas temperature range: -20 to +350 °C
Cross-section
2
in mm
Thermocouple Fe-Con L
2x 0.22 3.5 DIN 43714 2.50 00006479 2x 0.50 4.3 DIN 43714 1.25 00017856 4x 0.22 3.5 DIN 43714 2.50 00017857
Thermocouple Fe-Con J
2x 0.22 3.5 EN 60584/Cl. 1 2.50 00341902 2x 0.50 4.7 EN 60584/Cl. 1 1.25 00341903
Thermocouple NiCr-Ni K
2x 0.50 4.0 EN 60584/Cl. 2 2.00 00017858 4x 0.50 3.4 EN 60584/Cl. 2 2.00 00017860
Thermocouple Pt10Rh-Pt S
2x 0.50 4.7 EN 60584/Cl. 2 0.20 00017859 4x 0.50 3.5 EN 60584/Cl. 2 0.20 00017861
Diameter in mm
Color coding/ Class
/m per thermocouple
Part no.
2
1
2
1
1
1
2
1
2
available from stock Item 1
1. with galvanized steel braiding
2. with stainless steel braiding
2010-03-08/00073425
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,
Postal address: Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
36039 Fulda, Germany 36035 Fulda, Germany
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow - Essex CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 63 52 62 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
Compensating cables for dry and damp areas temperature range: -50 to +180 °C
1-800-554-JUMO
Data Sheet 90.9735 (90.9723) Page 2/8
Cross-section
2
in mm
Diameter in mm
Color coding/ Class
/m per thermocouple
Part no.
Thermocouple Fe-Con L
2x 0.50 4.7 DIN 43714 1.25 00017846 4x 0.22 4.5 DIN 43714 2.50 00017848
Thermocouple NiCr-Ni K
2x 0.22 3.2 EN 60584/Cl. 2 4.50 00052898 2x 0.50 4.7 EN 60584/Cl. 2 2.00 00017847 4x 0.22 4.7 EN 60584/Cl. 2 4.00 00017849
available from stock
Compensating cables for dry and damp areas temperature range: -50 to +180 °C
Item 2
Cross-section
2
in mm
Diameter in mm
Color coding/ Class
/m per thermocouple
Part no.
Thermocouple Fe-Con L
2x 1.50 6.5 DIN 43714 0.42 00017853
Thermocouple NiCr-Ni K
2x 1.50 6.5 EN 60584/Cl. 2 0.70 00017854
Thermocouple Pt10Rh-Pt S
2x 1.50 6.7 EN 60584/Cl. 2 0.07 00017855
available from stock
2010-03-08/00073425
Item 3
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,
Postal address: Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
36039 Fulda, Germany 36035 Fulda, Germany
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow - Essex CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 63 52 62 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
Compensating cables for dry and damp areas temperature range: +5 to +105 °C
1-800-554-JUMO
Data Sheet 90.9735 (90.9723) Page 3/8
Cross-section
2
in mm
Diameter in mm
Color coding /m per
thermocouple
Part no.
Thermocouple Fe-Con L
2x 0.22 3.7 DIN 43 714 2.50 00038959
available from stock
Compensating cables for dry areas temperature range: -20 to +350 °C
Item 4
Cross-section
2
in mm
Ext. dimension in mm
Color coding/ Class
/m per thermocouple
Part no.
Thermocouple Fe-Con L
2x 0.19 1.20 x 1.85 DIN 43714 3.20 00010497
Thermocouple NiCr-Ni K
2x 0.19 1.20 x 2.00 EN 60584/Cl. 2 5.20 00060294
available from stock