JUMO 906123 User Manual

Data Sheet 90.6123 Page 1/3
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
Platinum-chip temperature sensors with terminal clamps to EN 60 751
for temperatures from -30 to +105°C
standardized nominal values and tolerances
with the nominal values 100, 500 and 1000Ω
stable terminal clamps
coated with an additional protective varnish
Introduction
PCKL style platinum-chip temperature sensors are manufactured in the same way as the standard PCA style thin-film sensors. However, there are some differences in the connecting wire techniques. Compared with the standard temperature sensors, these sensors do not feature bonded connecting wires, but have terminal clamps that are pushed on and soldered on. The terminal clamps are distinguished by their exceptionally high directional and bending strength.
In addition, all JUMO temperature sensors with terminal clamps are coated with an additional protective varnish, which makes them ideally suited to a variety of probe constructions used in the HVAC sector. The application temperature ranges from -30 to +105°C.
PCKL style
Technical publication
JUMO platinum temperature sensors
Construction and application of platinum temperature sensors Data Sheet 90.6000 Platinum-glass temperature sensors Data Sheet 90.6021 Platinum-ceramic temperature sensors Data Sheet 90.6022 Platinum-foil temperature sensors Data Sheet 90.6023 Platinum-glass temperature sensors with glass extension Data Sheet 90.6024 Platinum-chip temperature sensors with connecting wires Data Sheet 90.6121 Platinum-chip temperature sensors on epoxy card Data Sheet 90.6122 Platinum-chip temperature sensors with terminal clamps Data Sheet 90.6123 Platinum-chip temperature sensors in cylindrical style Data Sheet 90.6124 Platinum-chip temperature sensors in SMD style Data Sheet 90.6125
2008-09-24/00415563
This revised edition takes account of altered standards and recent developments. The new chapter “Measurement uncertainty” incorporates the basic concept of the internationally recognized ISO guideline “Guide to the expression of uncertainty in measurement” (abbreviated: GUM). In addition, the chapter on explosion protection for thermometers has been updated in view of the European Directive 94/9/EC, which has been in force since 1st July 2003.
August 2002 Publication FAS 146 Sales No. 90/00085081 ISBN: 978-3-935742-07-8
Data Sheet 90.6123 Page 2/3
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
Platinum-chip temperature sensors
PCKL style with terminal clamps to EN 60 751
Brief description
PCKL style platinum-chip temperature sensors feature especially rigid terminal clamps for the electrical connection. One particular advantage is their high bending strength. Furthermore, the rectangular cross-section of the terminal clamps ensures excellent directional stability of the temperature sensor when assembled. PCKL style platinum-chip temperature sensors lend themselves ideally to a variety of probes for use in the HVAC sector and, since the sensor is openly positioned in the air stream.
The entire temperature sensor including the solder joint is additionally coated with epoxy protective varnish, as a protection against condensation and external effects.
Of course, all the positive characteristics of platinum-temperature sensors such as standardized nominal values to EN 60 751, high long-term stability and good reproducibility of the electrical properties also apply to this style, thereby ensuring universal usability and interchangeability.
Temperature sensors packed in bags
Temperature sensor Connecting wire Sales No. for tolerance class
Type R0/Ω B L H Material Dim. L1 RL in mΩ/mm 1/3 DIN B A B
PCKL 1.4005.1 1x100 4.5 6.6 1.9 CuSnP 0.55x0.25 9.2 1.0 90/00474119T on request 90/00480911T PCKL 1.4005.5 1x500 4.5 6.6 1.9 CuSnP 0.55x0.25 9.2 1.0 on request on request on request PCKL 1.4005.10 1x1000 4.5 6.6 1.9 CuSnP 0.55x0.25 9.2 1.0 90/00457334T on request 90/00480913T
Dim. tolerances: ΔB = ±0.3 / ΔL = ±0.8 / ΔH = ±0.3 / Dim. = approx. dim. / ΔL1 = ±0.8 For a definition of the tolerance classes, Dimensions in mm. see Data Sheet 90.6000
T = bag
Dimensional drawing
2008-09-24/00415563
Loading...
+ 1 hidden pages