JUMO 902520 User Manual

JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
Indoor, outdoor and channel RTD temperature probe
For temperatures from -50 ... +90 °C (200 °C)
For application in the air conditioning technology
Protection class IP20 to IP65
Connection: in 2-wire, 3-wire or 4-wire circuit
Available with 4 ... 20 mA or 0 ... 10 V transmitter
Indoor, outdoor and channel RTD temperature probes for air conditioning technology are mainly used for temperature measurement in rooms, in air channels and outdoors.
Various device versions made of plastic with different protection classes are available for the respective measuring task.
The measuring insert is normally fitted with a Pt 100 temperature probe as per DIN EN 60751, Class B in 2-wire circuit, versions with Pt500, Pt1000 or Ni1000 can also be supplied. From the connection terminals, wiring in 3-wire and 4-wire circuit is also possible. A transmitter can be optionally integrated.
Data sheet 90.2520 (90.2523) Page 1/7
Technical Data
Connection case Plastic case PC (basic type 902520/11 material PP), IP20 to IP65,
basic type 902524/25 protection class IP54 and IP65
Sheath Stainless steel 1.4571; Ø 5.4 mm, Ø 6 mm Measuring insert Pt100 temperature probe, DIN EN 60751, class B, 2-wire circuit
Transmitter Analog transmitters, output signal 4 ... 20 mA or 0 ... 10 V
Pt1000 temperature probe, DIN EN 60751, class B, 2-wire circuit, For further probes, refer to the order details
2011-05-20/00311507
Data sheet 90.2520 (90.2523) Page 2/7
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
- ++-
+
-
+
-
4 - 20mA
IndicatorController
2-wire transmitter
Supply unit
7.5 - 30V DC
+ --+
+
-
-
+
0 - 10V
IndicatorController
3-wire transmitter
Supply unit 15 - 30V DC
+
0 - 10V
L1
N
81
8382
15 - 30V DC
Supply voltage
TerminalConnection for
Voltage output 0 - 10V
+ 81
- 82
- 82
+ 83
81+83
+
Load 10k≥Ω
Output 0 - 10V
82
-
Output 4 - 20mA
22mA
- 7.5V
b
U
B
R =
R
B
= burden resistance
b
= supply voltage
U
-
82
+
81
- 82
+ 81
Current output 4 - 20mA
Supply voltage
7.5 - 30V DC
TerminalConnection for
Transmitter Output 4 ... 20 mA Output 0 ... 10 V
Input
Measuring input Pt100 (DIN EN 60751) Probe current 0.5 mA Measuring range Permanent measurement due to analog signal path
Measuring circuit monitoring
Underrange dropping to 3.6 mA 0 V Overrange increasing to ÷ 22 mA ... < 28 mA (typical
24 mA)
increasing to ÷ 11 V... < 14 V
(typical 12 V)
Probe short-circuit 3.6 mA 0 V Probe and wire break ÷ 22 mA ... < 28 mA (typical 24 mA) ÷ 11 V... < 14 V (typical 12 V)
Output
Output signal load-independent direct current 4 ... 20 mA Direct current 0 ... 10 V Transmission behavior temperature linear Transmission accuracy ≤ ±0.1% ±0.2% Damping of the residual ripple
of a voltage supply of 24 V, amplitude 10 V/50 Hz, burden 470 Ω/Load 10MΩ
37 dB 40 dB
Burden (Rb) Rb = (Ub - 7.5 V) / 22 mA ­Burden influence
± 0.02 % / 100 Ω
1
-
Load/load influence - ÷ 10 kΩ / ≤ ±0.1% Setting time for temperature changes ≤ 10 ms Adjustment conditions DC 24 V / approx. 22 °C Calibration accuracy
±0.2%
1,2
or ±0.2K
Overall accuracy, probe/calibration ± 0.4 K (typical) at 20 °C / 24 V voltage supply
Voltage supply
Voltage supply (Ub) DC 7.5 ... 30 V DC 15 ... 30 V Reverse voltage protection yes Voltage supply influence
± 0.01 %/V deviation from 24 V
1
Environmental influences
Operating temperature range -40 ...+ 85 °C Storage temperature range -40 ... +100 °C Temperature coefficient
Ambient conditions similar to DIN EN 60654 Kl. C1
EMC Interference emission/ resistance
1. All specifications referring to the measuring range limit value of 20mA. 2. The higher value is valid.
relative humidity 95 % annual average, no condensation
EN 61326 class B/Industrial requirements
± 0.01 %/K deviation from 22 °C
1
Connection example with power pack, output 4 ... 20 mAConnection example with power pack, output 0 ... 10 V
Connection diagram
2011-05-20/00311507
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
Dimensions
Data sheet 90.2520 (90.2523) Page 3/7
Basic type 902520/10 Basic type 902520/11 Basic type 902520/12
Basic type 902520/13 Basic type 902520/15 Basic type 902524/20
2011-05-20/00311507
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
Basic type 902524/25
Data sheet 90.2520 (90.2523) Page 4/7
2011-05-20/00311507
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
Order details: Indoor and outdoor RTD temperature probe
(1) Basic type
902520/10 Indoor RTD temperature probe
Protection class IP20
Data sheet 90.2520 (90.2523) Page 5/7
902520/11 Indoor and outdoor RTD temperature probe
Protection class IP54
902520/12 Indoor and outdoor RTD temperature probe
Protection class IP65
902520/13 Indoor and outdoor RTD temperature probe
with stepped sheath Protection class IP65
902520/15 Outdoor RTD temperature probe
Protection class IP65
(2) Operating temperature in °C
x 361 -50 ... +90 °C
x x 568 -30 ... +60 °C (measuring range only in connection with extra code 330 or 333)
x x x 572 -30 ... +80 °C (standard)
x 635 -20 ... +80 °C (standard) x x x 803 0 ... 40 °C (measuring range only in connection with extra code 330 or 333) x x x 807 0 ... 60 °C (measuring range only in connection with extra code 330 or 333)
(3) Measuring insert
x x 1001 1x Pt 100 in 3-wire-circuit xxxxx 1003 1x Pt 100 in 2-wire circuit xxxxx 1005 1x Pt1000 in 2-wire circuit x x x x 1009 1x Ni1000 in 2-wire circuit
x 1619 1x KTY 81-110 x 1728 1x NTC 1 kOhm
x 2001 2x Pt100 in 3-wire-circuit
x x x 2003 2x Pt100 in 2-wire circuit
(4) Tolerance class as per DIN EN 60 751
x 0 Technical data Ni/NTC/KTY xxxxx 1 Class B (standard) x x x 2 Class A (not for basic type 902520/10 in connection with transmitter) x x x 3 Class AA (1/3 DIN B) (not for basic type 902520/10 in connection with transmitter)
(5) Extra codes
xxxxx 000 None x x x 330 Transmitter analog, output 4 ... 20 mA x x x 333 Transmitter analog, output 0 ... 10 V
2
(in connection with 1x Pt100)
2
(in connection with 1x Pt100)
x 903 Cable screw-connection (IP65)
(1) (2) (3) (4) (5) Order code ---/ Order example 902520/10 - 572 - 1001 - 1 / 000
1
List extra codes in sequence, separated by commas.
2
Specify measuring range in plain text.
2011-05-20/00311507
,...
1
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
Order details: Channel RTD temperature probe
(1) Basic type
902524/20 Channel RTD temperature probe
with stepped sheath Protection class IP65
Data sheet 90.2520 (90.2523) Page 6/7
902524/25 Channel RTD temperature probe
with plain sheath Protection class IP54
(2) Operating temperature in °C
x 380 -50 ... +200 °C (standard) x 568 -30 ... +60 °C (measuring range only in connection with extra code 330 or 333) x 572 -30 ... +80 °C (standard) x 807 0 ... 60 °C (measuring range only in connection with extra code 330 or 333)
(3) Measuring insert
x x 1003 1x Pt 100 in 2-wire circuit x x 1005 1x Pt1000 in 2-wire circuit x x 1009 1x Ni1000 in 2-wire circuit x 2003 2x Pt100 in 2-wire circuit
(4) Tolerance class as per DIN EN 60 751
xx 1 Class B (standard) xx 2 Class A x3Class AA (1/3 DIN B)
(5) Sheath diameter D in mm
x x 6 Ø 6 mm (for basic type 902524/20 Ø 6 mm stepped down to Ø 3.3 mm)
(6) Nominal length NL in mm (NL 50 ... 500)
x x 100 100 mm
x 150 150 mm
x 200 200 mm
x ... Please specify in plain text (50 mm steps)
(7) Process connection
x x 000 None x x 252 Sheath screw-connection G 1/4 x x 254 Sheath screw-connection G 1/2 x x 662 Stop flange Ø 6 mm
(8) Extra codes
x x 000 None
x 310 Sheath Ø 6 mm stepped down to Ø 3.3 mm x 330 Transmitter analog, output 4 ... 20 mA x 333 Transmitter analog, output 0 ... 10 V
2
(in connection with 1x Pt100)
2
(in connection with 1x Pt100)
x 404 Protection class IP65
(1) (2) (3) (4) (5) (6) (7) (8) Order code - - - - - - / ,... Order example 902524/20 - 572 - 1003 - 1 - 6 - 100 - 252 / 000
1
List extra codes in sequence, separated by commas.
2
Specify measuring range in plain text.
2011-05-20/00311507
1
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO
1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us
Data sheet 90.2520 (90.2523) Page 7/7
Stock versions
Order code Part No.
902520/10-572-1001-1/000 90/00065671 902520/10-572-1005-1/000 90/00397862 902520/10-803-1003-1/330 (0 to 40 °C) 90/00064003 902520/10-807-1003-1/330 (0 to 60 °C) 90/00065717 902520/10-803-1003-1/333 (0 to 40 °C) 90/00439187 902520/11-635-1003-1/000 90/00055723 902520/12-572-1003-1/000 90/00064881 902520/12-572-1005-1/000 90/00350019 902520/12-807-1003-1/330 (0 to 60 °C) 90/00064883 902520/13-572-1003-1/000 90/00419733 902520/13-572-1005-1/000 90/00404301 902520/13-568-1003-1/330 (-30 to +60 °C) 90/00419736 902520/13-568-1003-1/333 (-30 to +60 °C) 90/00439195 902520/15-361-1003-1/000 90/00546799 902520/15-361-1005-1/000 90/00546802 902520/15-361-1003-1/903 90/00546800 902520/15-361-1005-1/903 90/00546801 902524/20-572-1003-1-6-100-662/000 90/00064894 902524/20-568-1003-1-6-100-662/330 (-30 to +60 °C) 90/00065087 902524/25-380-1003-1-6-100-000/310,404 90/00410556 902524/25-380-1003-1-6-150-000/310,404 90/00410562 902524/25-380-1003-1-6-200-000/310,404 90/00410563
2011-05-20/00311507
Loading...