JRC NSVS1097 User Manual

NSVS1097 Jan. 2005

JRC SAW FILTER

NSVS1097

Application

243.95MHz PHS Base-Station 1st IF

Electrical Specification: (Table 1)

The device characteristics are measured in the circuit shown in Fig.1.

Table 1. Electrical Specifications

Item

 

Spec.

Typ.

Nominal Center Frequency (f0)

243.95MHz

-

3dB Band Width

 

±130kHz

-

Insertion Loss at f0

 

4.0dB

3.3dB

Ripple

f0±100kHz

0.85dB

0.40dB

Group Delay Time Ripple

f0±100kHz

0.85us

0.40us

 

 

 

-

-

Attenuation

 

f0±600kHz

25dB

30dB

 

 

f0±10.7MHz

50dB

65dB

 

 

f0±21.4MHz

60dB

65dB

(Operating Temperature Range : -30 +85 )

Maximum Rating: (Table 2)

Table 2. Maximum Ratings

Item

Rating

Maximum Input Power

+5dBm

Operating Temperature Range

-30~+85ºC

Storage Temperature

-40~+95ºC

Mechanical Specifications: (Fig.2)

Package is designed as small as 3.5x3.5x1.0[mm3] for SMD (Surface Mount Device) type.

Notice:

This part is electrostatic discharge sensitive and may be damaged by improper handling.

Communications Equipment Division

Communications Equipment Marketing Department

10-1, Nishi-Shinjuku 6-chome, Shinjuku-ku,

Tokyo, 160-8328 Japan

Tel. +81 3-3348-3845

Fax. +81 3-3348-3935 http://www.jrc.co.jp/jp/product/device/saw/index.html (Japanese) http://www.jrc.co.jp/eng/product/saw/index.html (English)

JRC NSVS1097 User Manual

NSVS1097 Jan. 2005

 

1

8

7

OUT

 

2 SAW 6

50 Ω

 

 

IN

3

4

5

 

50Ω

 

 

 

 

 

Fig.1 Measuring circuit

 

 

 

 

(b)

 

 

(a)

 

 

3.5±0.2

 

( c )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

511

 

0.2

S7

(1)

 

±

 

3.5

 

 

 

 

 

 

 

(2)

 

0±0.2

 

 

 

 

1.

 

 

 

 

 

(0.95)

4

(0.8)

 

 

 

[5x]

 

3

 

 

5

 

 

 

 

 

 

(0.6)

 

(06). [8x]

 

 

 

 

4)

2

 

 

6

.5

 

 

 

2)

 

 

 

(

7

 

 

 

 

2

 

 

 

 

.

 

 

 

 

1

 

 

 

 

(

 

(1.0) [2x]

7

 

1

 

 

 

 

8

 

 

Fig.2 Package Dimensions (in mm)

 

 

1.3

4.3

 

 

 

 

 

 

 

[6x]

 

 

 

 

 

 

0.8 [6x]

1.27

 

 

 

 

1.27

 

 

 

4.3

 

 

ViaHole( φ0.3)

 

 

 

0.8

Fig.3 Desirable land area (in mm)

Marking

(1)Lot Number

(a)Year

(b)Month

Oct. --- X

Nov. --- Y

Dec. --- Z

(c)Date

0 - 9 0

10 - 19 1

20 - 31 2

(2) Part number Mark

Pin no.

Connection

1

GND

2

IN/OUT

3

GND

4

GND

5

GND

6

OUT/IN

7

GND

8

GND

Loading...