■ GENERAL DESCRIPTION

The NJU7700/01 is a low quiescent current voltage detector featuring high precision detection voltage.

The detection voltage is fixed internally with an accuracy of 1.0%.

NJU7700 is Nch. Open Drain and NJU7701 of output form is a C-MOS output.

■ FEATURES

 

± 1.0%

●High Precision Detection Voltage

●Low Quiescent Current

 

0.8uA typ.

●Detection Voltage Range

 

1.3~6.0V(0.1V Step)

●Output Circuit Form

NJU7700: Nch. Open Drain type

 

NJU7701: C-MOS Output

●Package Outline

MTP5 (SOT-23-5)

■ PACKAGE OUTLINE

NJU7700/01F

■ PIN CONFIGURATION

 

 

 

 

 

PIN FUNCTION

1

 

 

 

5

1.VOUT

2

 

 

 

 

2.VDD

 

 

 

 

 

 

 

 

3.VSS

 

 

 

 

 

3

 

 

 

4

4.NC

 

 

 

 

 

 

 

 

5.NC

 

 

 

 

 

 

 

 

 

 

■ EQUIVALENT CIRCUIT

VDD

VDD

 

 

 

VO

VO

VREF

 

 

VREF

VSS

 

 

 

VSS

 

NJU7700

 

 

NJU7701

■ DETECTION VOLTAGE RANK LIST

 

 

Device Name

VDET

Device Name

VDET

 

NJU7700/01F13

1.3V

NJU7700/01F28

2.8V

 

NJU7700/01F21

2.1V

NJU7700/01F42

4.2V

 

NJU7700/01F22

2.2V

NJU7700/01F43

4.3V

 

NJU7700/01F23

2.3V

NJU7700/01F45

4.5V

 

NJU7700/01F27

2.7V

NJU7700/01F06

6.0V

 

Ver.2003-03-10

- 1 -

NJU7700/01

■ NJU7700

 

 

 

 

 

 

 

 

 

 

 

 

 

■ABSOLUTE MAXIMUM RATINGS

 

 

 

(Ta=25°C)

 

 

 

 

PARAMETER

 

SYMBOL

RATINGS

 

UNIT

 

 

 

 

 

Input Voltage

 

VDD

+10

 

V

 

 

 

 

 

Output Voltage

 

VOUT

 

 

 

 

V

 

 

 

 

 

 

 

VSS-0.3 +10

 

 

 

 

 

Output Current

 

IOUT

50

 

mA

 

 

 

 

 

Power Dissipation

 

PD

200

 

mW

 

 

 

 

 

Operating Temperature

Topr

− 40

+85

 

°C

 

 

 

 

 

Storage Temperature

 

Tstg

− 40

+125

 

°C

 

 

 

 

 

■ ELECTRICAL CHARACTERISTICS (Ta=25°C)

 

 

 

 

 

 

 

 

 

PARAMETER

 

SYMBOL

 

TEST CONDITION

MIN.

TYP.

MAX.

UNIT

Detection Voltage

 

VDET

 

 

 

 

 

 

 

 

-1.0%

+1.0%

V

Hysteresis Voltage

 

VHYS

 

 

 

 

 

 

 

 

VDET

VDET

VDET

V

 

 

 

 

 

 

 

 

 

× 0.03

× 0.05

× 0.08

 

 

 

 

 

 

 

 

 

 

 

 

Quiescent Current

 

ISS

 

VDD=VDET+1V

 

VDET=1.3V 1.7V Version

0.5

1.0

uA

 

 

 

VDET=1.8V 6.0V Version

0.8

1.6

 

 

 

 

 

 

 

 

Output Current

 

IOUT

 

Nch,VDS=0.5V

 

VDD=1.2V

0.75

2.0

mA

 

 

 

VDD=2.4V (≥ 2.7V Version)

4.5

7.0

 

 

 

 

 

 

 

 

Output Leak Current

 

ILEAK

 

VDD=VOUT=9V

 

 

 

 

 

0.1

uA

Detection Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

∆ VDET /∆ Ta

Ta=0

+85°C

 

 

 

 

 

± 100

ppm/°C

Coefficient

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Voltage

 

VDD

 

RL=100kΩ

 

 

 

 

 

0.8

9

V

(*note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*note 1 : The minimum Operating Voltage(VOPL) indicates the same value of the output voltage(VOUT) on condition that VOUT becomes 10% or less of the input voltage(VDD).

- 2 -

Ver.2003-03-10

Loading...
+ 2 hidden pages