RESET terminal.
When the low-level input-signal, the system is initialized.
OTP control input terminal
NJU3555
F U N C T I O N
- 3 -
NJU3555
Difference between NJU3555 (OTP version) and NJU3505 (MASK version)
■
●
Operating mode
NJU3555
mode”.
•
Normal operating mode
•
OTP Programming mode
●
Programming memory (OTP)
The address location of pr ogramming memory (OTP) of
NJU3505
The option area is located in page 127(64bytes) in the following.
has two operating modes. One is ”Normal operating mode” and the other is “OTP programm ing
The ”TEST” terminal is set to low level. (The terminal is recommended to connect to GND.)
Operating voltage range; 2.7V ~ 5.5V
.
User program is read out from or written into the OTP by the universal programmer “SUPERPRO/ L” and
converting adapter made by XELTEK co,.(USA).
NJU3555
is compatible with the mask ed ROM of
, excepting the option area.
Program Area :
Option Area :
Addresses
Addresses
0000H ~ 1FBFH
1FC0H ~ 1FFFH
: 8,128bytes
: 64bytes
[ PROGRAM MEMORY AREA ]
Program Start Address
(Addresses) (Addresses in the bank)
0000H
07FFH
0800H
Bank 0
0000H
0040H
0080H
Page 0
Page 1
Page 2
Bank 1
0FFFH
1000H
17FFH
1800H
1FFFH
Bank 2
Bank 3
0780H
07C0H
07FFH
1FC0H
1FFFH
Page 30
Page 31
Bank 0
Option area
Page 127
∗
64 Instruction Words /Page
32 Pages / Bank
4 Banks / OTP
*
Page127 is program area.
(Addresses in the page)
00H
64 Instruction Words
3FH
8 Bits / Instruction Word
In case of NJU3505,
- 4 -
NJU3555
●
Reset Terminal Type
NJU3555 NJU3505
Internal Pull-up Resistance
●
Option information set in the initialization
When the initialization is perf orm ed(RESET ter m inal is “L” ), the operation inf orm ation stor ed in option area is
set as shown in the following timing chart . The option information is set in the term of
RESET releasing and oscillation stability time. Af ter inform ation set, the progr am c ounter is set to 0000H and
NJU3555
the
operates in normal.
[ TIMING CHART ]
Oscillator
Clock
Oscillation
Stability
Time
RESET
With Pull-up
Option information setting
x512clock
1/f
OSC
Oscillation
Start
f
=4MHz
OSC
about 128µsec
Without Pull-up
Normal
Operation
PC=0000H
1 / f
OSC
x 512clock
after
- 5 -
NJU3555
ABSOLUTE MAXIMUM RATINGS
■
(Ta=25°C)
PARAMETER SYMBOL RATINGS UNIT
Supply Voltage VDD -0.3 ~ +7.0 V
Input Voltage VIN -0.3 ~ V
Output Voltage V
-0.3 ~ V
OUT
Analog Supply Voltage AVDD -0.3 ~ V
Analog Reference Voltage V
-0.3 ~ AV
REF
Analog Input Voltage AIN0 ~ AIN7 -0.3 ~ AV
Operating Temperature
Storage Temperature
T
-20 ~ +75
opr
T
-55 ~ +125
stg
+ 0.3 V
DD
+ 0.3 V
DD
+ 0.3 V
DD
+ 0.3 V
DD
+ 0.3 V
DD
°
C
°
C
Note)
The difference of electrical characteristics between
NJU3555
(OTP version) and
NJU3505
(MASK version)
NJU3505 NJU3555
•
Supply Voltage (VDD) MIN.
2.4V
→
2.7V
•
Supply Current
5V (I
(I
(I
(I
(I
DD1
DD2
DD3
DD4
DD5
) Max.
) Max.
) Max.
) Max.
) Max.
1.2mA
1.2mA
1.6mA
4.0mA
4.0µA
→
→
→
30mA
30mA
30mA
30mA
20µA
→
3V (I
(I
(I
(I
(I
DD1
DD2
DD3
DD4
DD5
) Max.
) Max.
) Max.
) Max.
) Max.
0.5mA
0.5mA
0.6mA
1.0mA
2.0µA
→
→
20mA
20mA
20mA
→
→
20mA
20µA
- 6 -