NJU3551
4-BIT SINGLE CHIP OTP MICRO CONTROLLER
GENERAL DESCRIPTION
■
NJU3551
The
Micro Controller with programmable Flash Memory.
It is completely compatible with the
and the pin configuration. Therefore, the
suitable for the final evaluation before
generation, the small quantity production and short leadtime.
* In this data sheet, only OTP programming and the
difference between NJU3551 and NJU3501 are
mentioned mainly.
Therefore the detail function and specification should
be referred on the NJU3501 data sheet.
FEATURES
■
●
Internal One Time Programmable ROM 512 X 8bits
●
Internal Data RAM 64 X 4bits
●
Wide operating voltage range 2.7V ~ 5.5V
●
Package outline DIP20 / SOP20
●
ROM programmer “SUPERPRO/L” by XELTEK co,.
PIN CONFIGURATION IN OTP PROGRAMMING MODE
■
is the C-MOS 4-bit Single Chip OT P type
NJU3501
in function
NJU3551
NJU3501
mask
is
PACKAGE OUTLINE
■
NJU3551D NJU3551G
PRELIMINARY
Note) The pin configuration in Normal operating mode is the same as
Open
D0
D1
D2
D3
Open
PROM
CLK
REQ
V
SS
1
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
13
12
11
V
DD
Open
CNT2
CNT1
D7
D6
D5
D4
Open
RESET
NJU3501
.
- 1 -
NJU3551
BLOCK DIAGRAM
■
NJU3551
Interrupt Logic
DD
SS
V
V
CPU CORE
TEST
AC Y Reg X Reg
RESET
PRESCALER
Y’ Reg X’ Reg
PC
STACK
MUX
TLU addr
INT1
EXTI/PE0
INT2
TIMER
OSC1
OSC2
OSC
*1
*3
PORT_D
CPU
TIMING
GENERATOR
ALU
512 x 8 bit
OTP ROM
STANDBY
CONTROLLER
*1
*2
PORT_B
RAM
64 x 4 bit
*1
*3
PORT_A
SIO
SDI(O)/PC1
I D
SCK/PC2
I R
INT3
SDO/PC0
PD1
PD0
PB3
PB2
PB1
PB0
PA3
PA2
PA1
PA0
1 refer [INPUT OUTPUT TERMINAL TYPE] *2 Input / Output direction of 4-bit group is changed by the program. *3 Input / Output direction of each bit is selected by mask option.
*
- 2 -
TERMINAL DESCRIPTION IN OTP PROGRAMMING MODE
■
No. SYMBOL INPUT/OUTPUT F U N C T I O N
11 RESET INPUT
2 - 5,
13 - 16
D0 - D7 INPUT/OUTPUT Data bus
17, CNT1 INPUT
18 CNT2 INPUT
RESET terminal.
When the low-level input-signal, the system is initialized.
OTP control input terminal
9 REQ OUTPUT Request output terminal
8 CLK INPUT Clock input terminal
7 PROM INPUT OTP programming enable terminal
20 VDD - Power Source (5V)
10 VSS - Power Source (0V)
Note 1) Use at V
=5V in OTP programming mode.
DD
2) Non connect anything to the other terminals.
Difference between NJU3551 (OTP version) and NJU3501 (MASK version)
■
NJU3551
●
Operating mode
NJU3552
has two operating modes. One is ”Normal operating mode” and the other is “OTP programm ing
mode”.
•
Normal operating mode
The ”TEST” terminal is set to low level. (The terminal is recommended to connect to GND.)
Operating voltage range; 2.7V ~ 5.5V
.
•
OTP Programming mode
User program is read out from or written into the OTP by the universal programmer “SUPERPRO/ L” and
converting adapter made by XELTEK co,.(USA).
●
Option information set in the initialization
When the initialization is perf orm ed(RESET ter m inal is “L” ), the operation inf orm ation stor ed in option area is
OSC
set as shown in the following timing chart . The option information is set in the term of
1 / f
x 256clock
RESET releasing and oscillation stability time. Af ter inform ation set, the progr am c ounter is set to 0000H and
NJU3551
the
operates in normal.
[ TIMING CHART ]
Oscillation
Stability
Time
Option information setting
x256clock
1/f
OSC
Normal
Operation
Oscillator
Clock
Oscillation
Start
PC=0000H
RESET
f
=4MHz
OSC
about 64µsec
after
- 3 -
NJU3551
ABSOLUTE MAXIMUM RATINGS
■
(Ta=25°C)
PARAMETER SYMBOL RATINGS UNIT
Supply Voltage VDD -0.3 ~ +7.0 V
Input Voltage VIN -0.3 ~ V
Output Voltage V
Operating Temperature
Storage Temperature
-0.3 ~ V
OUT
T
-20 ~ +75
opr
-55 ~ +125
T
stg
+ 0.3 V
DD
+ 0.3 V
DD
°
C
°
C
Note)
The difference of electrical characteristics between NJU3551 (OTP version) and NJU3501
(MASK version)
NJU3501 NJU3551
•
Supply Voltage (VDD) MIN.
2.4V
→
2.7V
•
Supply Current
5V (I
(I
(I
(I
DD1
DD2
DD3
DD4
) Max.
) Max.
) Max.
) Max.
4.0mA
4.0mA
3.8mA
4.0µA
→
→
→
30mA
30mA
30mA
20µA
3V (I
(I
(I
(I
DD1
DD2
DD3
DD4
) Max.
) Max.
) Max.
) Max.
2.0mA
2.0mA
1.8mA
2.0µA
→
→
20mA
20mA
20mA
20µA
→
- 4 -