JRC NJU3152L, NJU3152G Datasheet

NJU3152
4-BIT SINGLE CHIP OTP TINY CONTROLLER
GENERAL DESCRIPTION
NJU3152
Micro Controller with programmable Flash Memory.
It is completely compatible with the and the pin configuration. Therefore, the suitable for the final evaluation before generation, the small quantity production and short lead­time.
* In this data sheet, only OTP programming and the
difference between NJU3152 and NJU3102 are
mentioned mainly. Therefore the detail function and specification should be referred on the NJU3102 data sheet.
FEATURES
Internal One Time Programmable ROM 1,024 X 8bits
Internal Data RAM 32 X 4bits
Wide operating voltage range 2.7V ~ 5.5V
Package outline SDIP22 / SOP22
ROM programmer “SUPERPRO/L” by XELTEK co,.
PIN CONFIGURATION IN OTP PROGRAMMING MODE
is the C-MOS 4-bit Single Chip OT P type
NJU3102
in function
NJU3152
NJU3102
mask
is
PACKAGE OUTLINE
NJU3152L NJU3152G
PRELIMINARY
Note) The pin configuration in Normal operating mode is the same as
Open D0 D1 D2
Open D7 D3
Open
PROM
CLK
REQ
V
SS
1 2 3 4 5 6 7 8 9 10 11
22 21 20 19 18 17 16 15 14 13 12
V
DD
Open
CNT2 CNT1
Open
D6 D5 D4 RESET
NJU3102
.
- 1 -
NJU3152
BLOCK DIAGRAM
TLUaddr
OTP ROM
1024 x 8 bit
PA0
MUX
I R
I D
PA1
PA2
STACK
PC
PA3
PORT_B PORT_A
PB0
CPU CORE
32 x 4 bit
PB1
PB2
PB3
ALU
RAM
Y’-Reg X’-Reg
PE0
PE1
AC Y-Reg X-Reg
CPU
TIMING
GENERATOR
STANDBY
CONTROLLER
PD0
PD1
PD2
PD3
V
DD
V
SS
TEST RESET
OSC
PORT_C PORT_D PORT_E
PC0
PC1
OSC1 OSC2
- 2 -
TERMINAL DESCRIPTION IN OTP PROGRAMMING MODE
No. SYMBOL INPUT/OUTPUT F U N C T I O N
12 RESET INPUT
RESET terminal. When the low-level input-signal, the system is initialized.
2 - 4,
6,
13 - 15,
D0 - D7 INPUT/OUTPUT Data bus
18
19, CNT1 INPUT
20 CNT2 INPUT
OTP control input terminal
10 REQ OUTPUT Request output terminal
9 CLK INPUT Clock input terminal
8 PROM INPUT OTP programming enable terminal 22 VDD - Power Source (5V) 11 VSS - Power Source (0V)
Note 1) Use at V
=5V in OTP programming mode.
DD
2) Non connect anything to the other terminals.
Difference between NJU3152 (OTP version) and NJU3102 (MASK version)
NJU3152
Operating mode
NJU3152
has two operating modes. One is ”Nor mal operating mode” and the other is “OT P programm ing
mode”.
Normal operating mode
The ”TEST” terminal is set to low level. (The terminal is recommended to connect to GND.) Operating voltage range; 2.7V ~ 5.5V
.
OTP Programming mode
User program is read out from or written into the OTP by the universal programmer “SUPERPRO/ L” and
converting adapter made by XELTEK co,.(USA).
Option information set in the initialization
When the initialization is perf orm ed(RESET ter m inal is “L” ), the operation inf orm ation stor ed in option area is
OSC
set as shown in the following timing chart . The option information is set in the term of
1 / f
x 256clock
RESET releasing and oscillation stability time. After information set, the pr ogram c ounter is set to 0000H and
NJU3152
the
operates in normal.
[ TIMING CHART ]
Oscillation Stability Time
Option information setting
x256clock
1/f
OSC
Normal Operation
Oscillator
Clock
Oscillation Start
PC=0000H
RESET
f
=4MHz
OSC
about 64µsec
after
- 3 -
NJU3152
ABSOLUTE MAXIMUM RATINGS
(Ta=25°C)
PARAMETER SYMBOL RATINGS UNIT Supply Voltage VDD -0.3 ~ +7.0 V Input Voltage VIN -0.3 ~ V Output Voltage V Operating Temperature Storage Temperature
-0.3 ~ V
OUT
T
-20 ~ +75
opr
-55 ~ +125
T
stg
+ 0.3 V
DD
+ 0.3 V
DD
°
C
°
C
Note)
The difference of electrical characteristics between
NJU3152
(OTP version) and
NJU3102
(MASK version)
NJU3102 NJU3152
Supply Voltage (VDD) MIN.
2.4V
2.7V
Supply Current
5V (I
(I (I (I
DD1 DD2 DD3 DD4
) Max. ) Max. ) Max. ) Max.
4.5mA
4.5mA
4.3mA
5.0µA
→ → →
30mA 30mA 30mA
20µA
3V (I
(I (I (I
DD1 DD2 DD3 DD4
) Max. ) Max. ) Max. ) Max.
2.3mA
2.3mA
2.1mA
3.0µA
→ →
20mA 20mA
20mA
20µA
- 4 -