JPL EHS-3, EHS-4, EHS-2, EHS-7, EHS-12 User Manual

...
WIRELESS HEADSET EHS GUIDE
Introduction
Electronic Hook Switch(EHS) provides a solution that enables remote operation of answer/end functions for wireless headsets with various phones, thus eliminating the
Mobility
With an EHS solution you can roam within your premises and still do business on the
spot. Wireless headsets with EHS functionality boost productivity as they provide the user with the ability to answer and end a call, while away from their desk.
EHS support the following phone system manufacturers:
Wireless Headset EHS User Guide
AASTRA / MITEL
6771, 6773ip, 6775ip, 7434ip, DS-DHSG Cable EHS-3 7444ip, 5370, 5370ip, 5380, 5380ip *6735i, *6737i, *6753i, *6755i, *6757i *Needs Aastra EHS kit
ALCATEL 4028 EE, 4038 EE, 4068 EE MSH Adapter EHS-7
AVAYA
1408, 1416, 1608, 1616, 1608i, 1616i, 2410, 4630, 5410, 6224D+M, 6416D+M, AEI-II(Avaya) Adapter Kit EHS-4 9404, 9406, 9408, 9504, 9508, 9608, 9610, 9611, 9620, 9621, 9630 9640, 9641, 9650, 9670,
CISCO 7942G , 7945G, 7962G, 7965G, 7975G HHC Adapter EHS-2
CISCO (with USB Port) 8961, 9951, 9971 HHC-2 Adapter EHS-12
ERICSSON-LG LG EHS Adapter LIP-9010, LIP-9020, LIP-9050 Needs Ericsson-LG EHSA Kit EHS-11
PANASONIC HDV230, HDV330, HDV430, Panasonic compatible EHS Cable EHS-1 NT543 , NT553, NT556, DT543, DT546
POLYCOM IP 320, 321, 330, 331, 335, 430, 450, 550, 650, 670, Polycom compatible EHS Cable EHS-5 VVX 300, 310, 400, 410, 500, 600, 1500
SHORETEL AEI-II Adapter Kit EHS-8 IP 565g, 560g, 560, 265, 230, 230g
SIEMENS/UNIFY OpenStage 40/60/80 DS-DHSG Cable EHS-3 OptiPoint Basic/Std/Adv/Eco
SNOM DS-Gender EHS-6 *300, *320, *360, *370, *720, *760, *820, *821, *870 *Needs SNOM EHS Adapter
TOSHIBA DP5022-SD, DP5022-SDM, DP5032-SD, DP5122-SD, DP5130-FSDL, DP5130-SDL, SHR (Toshiba)Adapter Kit EHS-8 DP5132-SD, IP5022-SD, IP5122-SD, IP5122-SDC, IP5131-SDL, IP5132-SD
YEALINK *T26P, *T27G, *T27P, *T28P, *T29G, *T40G, *T40P, DS-Gender EHS-6
*T41S, *T41P, *T42S, *T42G, *T46S, *T46G,* T48S *Needs Yealink EHS Adapter
SMART PHONE SmartPhone
Galaxy & iPhone Series EHS Adapter
EHS-9
Wireless Headset EHS Compatibility Table
Phone Model EHS Adapter JPL Part No
Aastra/Mitel EHS setup guide
Connection Diagram
DS-DHSG cable(EHS-3) : RJ-45(8P8C) to RJ-45(8P8C) and RJ-9(4P4C)
Aastra/Mitel Phones
+
EHEHS-3
6771/6773ip/6775ip 7434ip/7444ip 5370,5370ip 5380/5380ip
Connection Diagram
Note : Aastra DHSG cable kit is available from your Aastra reseller
DS-DHSG cable(EHS-3) : RJ-45(8P8C) to RJ-45(8P8C) and RJ-9(4P4C)Aastra DHSG cableRJ-45 Coupler
Note :
1. Audio mode needs to be set to Headset/Speaker mode manually. (Options->Preferences->Set Audio->Audio Mode->Headset/Speaker)
2. For full headset functionality, disable the Goodbye Key Cancels Incoming Call parameter.
Aastra Web UI: Basic Settings->Preferences->General
③ ① ②
Aastra EHS kit
Yellow End
Green End
Aastra/Mitel Phones
+
EHEHS-3
6735i, 6737i, 6753i, 6755i, 6757i
+
Alcatel EHS Setup guide
Connection Diagram
MSH cable(EHS-7) : RJ-12(6P6C) and 3.5Ø plug to RJ-45(8P8C) and RJ-9(4P4C)EHS PortAudio Port
Alcatel Phones
4028EE 4038EE 4068EE
+
EHS-7
////
Avaya EHS Setup guide
Connection Diagram
: Power cable (RJ-45 to RJ-12) : Telephone cord (RJ-9 to RJ-9) Cable length : 600mm : Telephone cord (RJ-9 to RJ-9) Cable length : 300mm : External Microphone for ring detection
Position of Telephone compatibility Switch : Set to 1 Compatibility switch is located on left side of the base unit.
Avaya Phones
1408 1416 1608 1616 2410 5410 6224D+M 6416D+M 9404 9408 9504 9508 9608 9610 9611 9620 9621 9630 9640 9641 9650 9570
+
EHS-4
Cisco EHS Setup guide
Connection Diagram
: HHC EHS Adapter (EHS-2) : RJ-45 to RJ-12 : Telephone cord (RJ-9 to RJ-9) Cable length : 600mm
Position of Telephone compatibility Switch : Set to 2 Compatibility switch is located on left side of the base unit.
Cisco Phones
7942G 7945G 7962G 7965G 7975G
+
EHS-2
Connection Diagram
: HHC EHS Adapter ( EHS-12) : RJ-45(8P8c) and RJ-9(4P4C) to USB A-type Plug : USB Port(A-type Female)
Cisco Phones
8961 9951 9971
1408,1416,2410,4630
+
EHS-12
③ ② ①
Ericsson-LG EHS Setup guide
Need Ericsson-LG EHSA Kit
Connection Diagram
LG EHS Adapter (EHS-11) : RJ-45(8P8C) to RJ-45(8P8C)Headset PortEHS Adapter : supplied from Ericsson-LG resellerAudio cables : RJ-9(4P4C) to RJ-9(4P4C)
Ericsson-LG Phones
LIP-9010 LIP-9020 LIP-9050
EHS-11
+
④ ② ①
Panasonic EHS setup guide
Connection Diagram
Panasonic EHS Adapter (EHS-1) : RJ-45(8P8c) to 3.5Ø Plug (3 poles)Headset PortEHS PortAudio cables : RJ-9(4P4C) to 3.5Ø Plug (3 poles)
Panasonic Phones
NT553 NT556 DT543 DT546
+
EHS-1
////
NT543
HDV230
HDV330
HDV430
Polycom EHS Setup guide
Connection Diagram
Polycom EHS Adapter (EHS-5) : RJ-45(8P8c) to 5-Pin PlugAudio cables : RJ-9(4P4C) to 2.5Ø Plug (3 poles)Headset PortEHS Port
Polycom Phones
IP 320 IP 321 IP 330 IP 331 IP 335 IP 435 IP 450 IP 550 IP 560 IP 650 IP 670 VVX 300 VVX 310 VVX 400 VVX 410 VVX 500 VVX 600 VVX 1500
+
EHS-5
③ ① ②
Connection Diagram
Polycom EHS Adapter (EHS-5) : RJ-45(8P8c) to 5-Pin PlugAudio cables : RJ-9(4P4C) to RJ-9(4P4C)EHS Port
Note 1: Phone must be running SIP application 3.1 or higher and BootROM 4.1.0 or later. Note 2: Phone must be running SIP application 3.0.2 or higher and BootROM 4.1.0 or later. Note 3: Phone must be running SIP application 3.1.0 Rev C or higher and BootROM 4.1.0 or later. Note 4: 2.5mm headset port connector requires Audio cable.
Instruction
Access your Polycom phone menu and change the headset settings to "Jabra Mode" or "Jabra DHSG" based on the manufacturer's instructions for your specific model. Depending on your phone model, you may need to complete this step after connecting the EHS adapter. Typically, changing the settings requires that you access the "Basic," "Preferences," and "Headset" sections in the menu on your phone. Once "Analog Headset Mode" appears on the screen, use the up and down arrows to select the Jabra Mode and then choose "Back," "Exit" or "Menu" to return to the main screen.
③ ① ②
ShoreTel EHS Setup guide
Connection Diagram
Power cable (RJ-45 to RJ-12) Telephone cord (RJ-9 to RJ-9) : Cable length : 600mm External Microphone : For ring detection
ShoreTel Phones
IP 565g IP 560g IP 560 IP 265 IP 230 IP 230g
+
EHS-8
0
Toshiba EHS Setup guide
Connection Diagram
Power cable (RJ-45 to RJ-12) Telephone cord (RJ-9 to RJ-9) : Cable length : 600mm External Microphone : For ring detection
EHS-8
Toshiba Phones
IP5022-SD IP5122-SD IP5122-SDC IP5131-SDL IP5132-SD DP5022-SD DP5022-SDM DP5032-SD DP5122-SD
DP5130-FSDL DP5130-SDL DP5132-SD
+
③ ① ②
Siemens/Unify EHS Setup guide
Connection Diagram (For OpenStage series)
DS-DHSG EHAS adpter (EHS-3) : RJ-45(8P8C) and RJ-9(4P4C) to RJ-45(8P8C)
Siemens Phones
OpenStage 40/60/80 OptiPoint Base/Adv/Eco
+
EHS-3
Connection Diagram (For OpenScape and Optipoint series)
DS-DHSG EHAS adapter (EHS-3) : RJ-45(8P8C) and RJ-9(4P4C) to RJ-45(8P8C)
////
SNOM EHS Setup guide
Connection Diagram
Cord (RJ-12 to RJ-12) supplied by manufacturer of EHS Adapter – snom 3xx/snom 820
Cord (RJ-45 to RJ-12) supplied by manufacturer of EHS Adapter – snom 821/snom 870
EHS Adapter supplied by SnomCord (RJ-45 to RJ-45) supplied by manufacturer of EHS AdapterEHS GenderTelephone cord (RJ-9 to RJ-9) : Cable length 600mm
Snom 3xx: 7.3.30 + bootloader 1.1.3u and higher Snom 7xx: 8.7.3.6 and higher Snom 8xx: 8.4.32 and higher
SNOM Phones
SNOM 300/320/360/370 SNOM 720/760 SNOM 820/821/870
+
EHS-6
SNOM EHS Adaptor
+
Yealink EHS Setup guide
Connection Diagram
Cord (RJ-12 to RJ-12) supplied by manufacturer of EHS AdapterEHS Adapter supplied by YealinkCord (RJ-45 to RJ-45) supplied by manufacturer of EHS AdapterEHS GenderTelephone cord (RJ-9 to RJ-9) : Cable length 600mm
Yealink Phones
T48S/T46S/T46G T42S/T42G/T41S T41P/T40G/T40P T29G/T27G/T27P
+
EHS-6
Yealink EHS Adaptor
+
////