JOYTECH PY800AC, PY1400AC User Manual

Sliding Gate Operator
User's Manual
PY800AC/PY1400AC
PY800AC/PY1400AC SLIDING GATE OPERATOR
1
1. Products introduction
Please read the instructions carefully before proceeding. MCU is supplied to control the gate operator. Keypad / single button interface. Have Infrared safety sensor interface. Soft start and soft stop function and the soft stop width are adjustable. Working time is adjustable. Motor output torque is adjustable. User can select Auto-close function. Manual key release designed for emergency purposes.
2. Important safety information
Carefully read and follow all safety precautions and warning before
attempting to install and use this automatic gate operator.
z The gate operator should be installed by a qualified technician;
otherwise, serious personal injury or property damage may occur.
z When opening or closing the gate, do not attempt to walk or
drive through the gate.
z If enable the auto-close function, must use the infrared sensor. z Children should not be allowed to play near or operate automatic
gates.
z The automatic gate operator must be grounded. z Install the gate operator on the inside of the property; DO NOT
install it on the outside of the property where the public has access to it.
z Be careful when in close proximity to moving parts where hands
or fingers could be pinched.
z Do not allow control devices to be placed so that a person can
PY800AC/PY1400AC SLIDING GATE OPERATOR
2
access them by reaching through the gate.
z In the event of power failure, an emergency release key allows
you to operate the gate manually.
z The operator should be switched off before repairing it or
opening its cover.
z Please erase and reprogram the transmitter code after installing
the operator.
Make sure the Power supply (AC220V or AC110V) of the gate operator is suitable for the power supply in your area.
3. Main technical parameters
Type PY800AC PY800ACU PY1400AC PY1400ACU
Power supply 220V, 50Hz 110V, 60Hz 220V, 50Hz 110V, 60Hz
Motor speed 52rpm 62rpm 52rpm 62rpm
Rated output power of
motor
360W 500W
Remote control
operating distance
30m
(Frequency: 433.92mHz)
30m
(Frequency:433.92mHz)
Remote control mode Single button Single button
Output shaft height 58.5mm 58.5mm
Max. gate weight 800Kg 1400Kg
Output torque 22N·m 32N·m
Noise 60dB 60dB
Duty cycle S2, 15 minutes S2, 15 minutes
extra remote control 20 20
Environmental
temperature
-20°C~+50°C -20°C~+50°C
Gate Move speed 12m/min 14m/min 12m/min 14m/min
4. Mechanical Installation
PY800AC/PY1400AC SLIDING GATE OPERATOR
3
The PY800AC/PY1400AC will handle gate weighting up to 800kg/1400 kg and up to 14m/20m if the proper installation procedures have been followed. The PY800AC/PY1400AC gate operator operates by forcing a drive rack by a drive gear. The entire configuration is shown in the diagram below. The gate operator must be installed on the inside of the gate.
Wall
Switch
Gate operator
Input power
Rack
Sliding gate
Fig.1 Gate preparation Be sure the gate is properly installed and slides smoothly before installing the PY800AC/PY1400AC sliding gate operator. The gate must be plumb, level, and move freely. Conduit In order to protect the cable, use PVC conduit for low voltage power cable and control wires. Conduit must be preset into the concrete when it is poured. Wires within the conduit shall be located or protected so that no damage can result from contact with any rough
PY800AC/PY1400AC SLIDING GATE OPERATOR
4
or sharp part. Concrete pad The base unit of the gate operator requires a concrete pad in order to maintain proper stability. The concrete pad should be approximately 450mm x 300mm x 200mm deep in order to providing for adequate weight and structure to insure proper stable installation. Anchors
(see Fig.2) Y ou can use anchor bolts, anchors, washers and nuts. These anchors must be set into the concrete when it is poured or you can use wedge anchors to fasten the operator.
Gate operator
Gear
Groundsill
Input power
Plain washer
Nut
Spring washer
Nut
Fig.2
Operator base (see Fig.3) After the concrete has hardened, mount the gate operator base to the concrete pad. Verify that the base is properly leveled. Using bolts and washers mount the gate operator to the base and insert the cover. Check the operator and make sure it is lined up with the gate.
PY800AC/PY1400AC SLIDING GATE OPERATOR
5
230
114
Fig.3
Installation of Rack
z Fix the three nuts (in the same package with rack) on the rack
element.
z Lay the first piece of rack on the gear and weld the first nut on the
gate.
z Move the gate manually, checking if the rack is resting on the
gear, and weld the second and third nut.
z Bring another rack element near to the previous one. Move the
gate manually and weld the three nuts as the first rack, thus proceeding until the gate is fully covered.
z When the rack has been installed, to ensure it meshes correctly
with the gear.
z The space between rack and gear is about 0.5mm.
PY800AC/PY1400AC SLIDING GATE OPERATOR
6
Fig.4
5. Adjustment
Spring limit switch z To ensure safety, it is recommended to install limit switches at
both ends of the gate to prevent the gate from sliding out of the rails. The rails must be installed horizontally.
z Install the limit block as shown in Fig.5 and Fig.6. The spring limit
switch and blocks are used to control the position of the gate.
z Release the gear with the key and push the sliding gate manually
to pre-determine the position, fix the block to the rack and lock the gear by push up the release bar. Moving the gate electrically, adjust the block to the proper position until the position of the opening and closing meet the requirement.
Magnetic limit switch z To ensure safety, it is recommended to install limit switches at
both ends of the gate to prevent the gate from sliding out of the rails. The rails must be installed horizontally.
z Install the limit block as shown in Fig.4 and Fig.5. The magnetic
of limit switch and blocks are used to control the position of the
PY800AC/PY1400AC SLIDING GATE OPERATOR
7
gate.
z Release the gear with the key and push the sliding gate manually
to pre-determine the position, fix the block to the rack and lock the gear by push up the release bar. Moving the gate electrically, adjust the block to the proper position until the position of the opening and closing meet the requirement.
Gear
Rack
limit block
Spring of limit switch
Sliding gate
Spring limit
Gear
Sliding gate
Rack
Limit block
Magnetic
Magnetic limit
Fig.5
Loading...