Josam Company KLEENATRON II Catalog

CLEANOUT FEATURES
CLEANOUT FEATURES
KLEENATRON®II Features
JOSAM KLEENATRON®II Cleanouts incorporate features developed to meet the latest in building construction methods. These features ensure the specifier, installer and user of completely trouble-free installation and performance.
WIDE CHOICE OF COVERS
Tops and covers for every area. Round-square, tile-terrazzo, medium-special-duty. Standard cast iron secured cover has special­duty rating.*
ADJUSTABLE BUSHING
Precision machine threaded cast iron bushing provides LEVELEZE adjustment; non-tilting top. Body protects threads from concrete, allowing adjustment after pour.
EASY IN – EASY OUT CLOSURE PLUG
ABS plastic closure plug with gas-tight sealing tapered threads.
OPTIONAL CLAMP RING
To secure waterproof membrane to flashing flange.
®
55000
55000-Y Series KLEENATRON Cleanouts feature JOSAM JIFFEE-SET connections with MULTI-TITE soil pipe gaskets in 2, 3 and 4 inch sizes for labor-saving assembly to service weight and no-hub cast iron pipe, and to PVC and ABS pipe. Merely lubricate gasket and pipe, set cleanout in place, push down until top of pipe contacts built-in stop and the joint is complete.
®
service weight (SV)
®
CLEANOUTS
OPTIONAL (-F) FLASHING FLANGE
Mates with machined exterior thread on ferrule to provide watertight connection without the additional use of sealant by others.
WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov
CAST IRON BODY
With interior threads to provide unimpaired LEVELEZE®adjustment of top section.
*SPECIAL-DUTY: Grates testing over 10,000 lb. (4500 kg.) ASME 112.6.3-2001.
185
CLEANOUTS
CLEANOUTS
How to Order
FLOOR CLEANOUTS – Unless optional materials are specified, standard material shown in Specification will be provided.
Example: Series No. 55000 Type No. 55004
55004 -Z -1 -VP -22
CLEANOUTS
WALL 0R FLOOR ACCESS COVERS – When outlet size does not apply, refer to dimension table for Type No. to be ordered.
Outlet Size Outlet Type, No Hub Outlet Optional Material, Satin Finish Nikaloy Top Option, Secured Cover, Vandal-Proof Screws Option, Taper Thread Bronze Plug
Example: Series No. 58630 Type No. 58631
58631 -CO3 -20 -VP
Type No. for 8” x 8” Cover No-Hub Cleanout, 3” Raised Head Bronze Plug Secured Cover, Vandal-Proof Screws
CLEANOUTS • Pictorial Selection Guide
CLEANOUTS • Pictorial Selection Guide
ADJUSTABLE FLOOR CLEANOUTS
55000
C.I. Cover, Internal Plug
Page 188
55000-1
Nikaloy Cover, Internal Plug
Page 188
55000-1-SD
Nikaloy Laminated C.I. Cover, Internal Plug
Page 189
55000-1-SQ
Nikaloy Cover, Internal Plug
Page 190
ADJUSTABLE FLOOR CLEANOUTS
57008-Z-1
Nikaloy Cover, Internal Plug
57008-Z-1-SD
Nikaloy Laminated C.I. Cover, Internal Plug
57008-Z-1-12
Nikaloy Cover Recessed for Tile, Internal Plug
57008-Z-LT
No-Hub Cast Iron Ferrule & ABS Plug
55000-1-13
Nikaloy Cover Recessed for Terrazzo Tile, Internal Plug
Page 191
58360
Nikaloy Cover, Bronze Plug
57008-Z-CI
Cast Iron Cover, Internal Plug
Page 192
58460A
Nikaloy Cover, Bronze Plug, Double Drainage Flange
Page 192
186
Page 192
Page 193
Page 193
Page 194
WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov
Page 194
CLEANOUTS • Pictorial Selection Guide
CLEANOUTS • Pictorial Selection Guide
ADJ. C.O. ACCESS HOUSINGS SPANNER
58460A-AE
Nikaloy Cover, Bronze Plug, Adjustable Collar
58580
Cast Iron Access Housing
58580-1
Nikaloy Access Housing
58580-1-SQ
Nikaloy Access Housing
58680
Heavy-Duty Access Housing
56670
Threaded Cover, Spanner Type
CLEANOUTS
Page 195
Page 196
Page 196
Page 197
Page 201
PLUG FERRULE C.O. TEE ACCESS COVERS
58540
N.P.T. Threaded Bronze Plug
Page 195
58900
No-Hub Ferrule, Bronze Plug
Page 203
58910
No-Hub Cleanout Tee, Bronze Plug
Page 204
58600
Access Cover
Page 198
58610
Access Cover with Anchor Lugs
Page 198
ACCESS COVERS COMBINATIONS
58630
Hinged Access Cover
58640
Secured Cover
58650
Secured Cover
58600-PLG
Access Cover & Plug
58600-CO
Access Cover and No-Hub Cleanout
Page 191
58620
Hinged Access Cover
Page 199
58600-COT
Access Cover and No-Hub Cleanout Tee
Page 199
Page 200
COMBINATIONS
58610-CO
Access Cover with Anchor Lugs & No-Hub Cleanout
Page 201
WARNING:
58610-COT
Access Cover with Anchor Lugs & No-Hub Cleanout Tee
Page 201
Cancer and Reproductive Harm - www.p65warnings.ca.gov
Page 200
58630-CO
Hinged Access Cover and No-Hub Cleanout
Page 202
Page 201
58630-COT
Hinged Access Cover and No-Hub Cleanout Tee
Page 202
Page 201
58640-CO
Secured Cover and No-Hub Cleanout
Page 203
Page 202
58640-COT
Secured Cover and No-Hub Cleanout Tee
Page 203
187
CLEANOUTS
CLEANOUTS
55000 SERIES LEVELEZE®KLEENATRON®II SPECIAL-DUTY
APPLICATION
For use in finished or unfinished floors subject to heavy wheel traffic such as ware­houses, loading docks and warehouse stores. Top design allows for unimpaired adjustment even as the floor is being poured.
SPECIFICATION
JOSAM 55000 Series coated cast iron LEVELEZE®KLEENATRON®II Floor Cleanout, internal ABS cleanout plug, adjustable cast iron housing with special-duty scoriated secured round cast iron cover.
CLEANOUTS
Available Options
-1 Satin Finish Nikaloy Top-1-SD Special-Duty Satin Finish
Nikaloy Top
-1-SQ Square Top,
Satin Finish Nikaloy
-1-12 Cover Recessed for Tile,
Satin Finish Nikaloy
-1-13 Terrazzo Tile Cover,
Satin Finish Nikaloy
-2 Satin Finish Bronze Top
-2-SD Special-Duty Satin Finish Bronze Top
-2-SQ Square Top, Satin Finish Bronze
-2-12 Cover Recessed for Tile,
Satin Finish Bronze
-2-13 Terrazzo Tile Cover, Satin Finish Bronze
-SS Stainless Steel Top
-SS-SQ Square Top, Stainless Steel
-5 Ductile Iron Top
-14 Carpet Cleanout Marker
-VP Secured Cover, Vandal-Proof Screws
-22 Taper Thread Bronze Plug
-31 Galvanized Cast Iron Parts
-41 Clamp Ring and Flange
-F Flange Only
-WF Wide Flange (not available on Cl)
-CFC Carpet Cleanout Flange Cover
OUTLETS:
-X Inside Caulk Outlet
-Y Hub Outlet w/Gasket, 2”-4”
-Z No-Hub Outlet
A
D
ADJUSTABLE
CAST IRON
BUSHING
PIPE SIZE
C
OPTIONAL (-41)
CLAMP RING
OPTIONAL (-F)
FLANGE
X
-MIN
- MAX
Y
B
FLANGE STANDARD ON 4” -X AND 6” SIZES.
*
THREADED
ABS PLUG
FOR OUTLET TYPE SPECIFY -X, -Y or -Z
TYPE NO. PIPE SIZE A B C* D X Y LBS.
55002 2 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 15 55003 3 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 15 55004 4 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 16 55004-X 4 7-1/2 4-1/4 9-3/16 7 2-5/8 4-5/16 18 55005-Z 5 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 16 55006-Z 6 7-1/2 4-1/4 9-3/16 7 2-5/8 4-5/16 18
55000-1 SERIES with -1 Nikaloy Top
APPLICATION
For use in finished floors subject to pedestrian and light wheel traffic such as schools, hospitals and shopping malls. Top design allows for unimpaired adjustment even as the floor is being poured.
SPECIFICATION
JOSAM 55000-1 Series coated cast iron LEVELEZE®KLEENATRON®II Floor Cleanout, internal ABS cleanout plug, adjustable cast iron housing with medium-duty scoriated secured round satin Nikaloy cover.
-MIN
X
- MAX
Y
B
FLANGE STANDARD ON 4” -X AND 6” SIZES.
*
THREADED
ABS PLUG
FOR OUTLET TYPE SPECIFY -X, -Y or -Z
TYPE NO. PIPE SIZE A B C* D X Y LBS.
55002-1 2 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 12 55003-1 3 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 12 55004-1 4 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 13 55004-1-X 4 6-5/8 4-1/4 9-3/16 7 2 3-11/16 14 55005-1-Z 5 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 12 55006-1-Z 6 6-5/8 4-1/4 9-3/16 7 2 3-11/16 14
D
A
ADJUSTABLE
CAST IRON
BUSHING
PIPE SIZE
C
OPTIONAL (-41)
CLAMP RING
OPTIONAL (-F)
FLANGE
188
WARNING:
Cancer and Reproductive Harm - www.p65warnings.ca.gov
Product Illustration follows.
CLEANOUTS
CLEANOUTS
55000-5 SERIES with -5 Ductile Iron Top
APPLICATION
For use in finished or unfinished floors subject to heavy wheel traffic or impact loads, such as warehouses, loading docks and warehouse stores. Top design allows for unimpaired adjustment even as the floor is being poured.
SPECIFICATION
JOSAM 55000-5 Series coated cast iron LEVELEZE®KLEENATRON®II Floor Cleanout, internal ABS cleanout plug, adjustable cast iron housing with special-duty scoriated secured round ductile iron cover.
OPTION N/A:
-WF
A
D
ADJUSTABLE
CAST IRON
BUSHING
PIPE SIZE
C
OPTIONAL (-41)
CLAMP RING
OPTIONAL (-F)
FLANGE
X
-MIN
- MAX
Y
B
FLANGE STANDARD ON 4” -X AND 6” SIZES.
*
THREADED
ABS PLUG
FOR OUTLET TYPE SPECIFY -X, -Y or -Z
TYPE NO. PIPE SIZE A B C* D X Y LBS.
55002-5 2 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 15 55003-5 3 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 15 55004-5 4 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 16 55004-5-X 4 7-1/2 4-1/4 9-3/16 7 2-5/8 4-5/16 18 55005-5-Z 5 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 16 55006-5-Z 6 7-1/2 4-1/4 9-3/16 7 2-5/8 4-5/16 18
CLEANOUTS
55000-1-SD SERIES with -1-SD Nikaloy Special-Duty Top
APPLICATION
For use in finished or unfinished floors subject to heavy wheel traffic or impact loads, such as warehouses, loading docks and warehouse stores. Top design allows for unimpaired adjustment even as the floor is being poured.
SPECIFICATION
JOSAM 55000-1-SD Series coated cast iron LEVELEZE®KLEENATRON®II Floor Cleanout, internal ABS cleanout plug, adjustable cast iron housing with special-duty scoriated secured round laminated satin Nikaloy cover.
-MIN
X
- MAX
Y
B
FLANGE STANDARD ON 4” -X AND 6” SIZES.
*
THREADED
ABS PLUG
FOR OUTLET TYPE SPECIFY -X, -Y or -Z
TYPE NO. PIPE SIZE A B C* D X Y LBS.
55002-1-SD 2 6-9/16 3-3/4 7-1/2 5-9/16 3 4-1/2 16 55003-1-SD 3 6-9/16 3-3/4 7-1/2 5-9/16 3 4-1/2 16 55004-1-SD 4 6-9/16 3-3/4 7-1/2 5-9/16 3 4-1/2 17 55004-1-SD-X 4 8-3/16 4-1/4 9-3/16 7 2-7/8 4-9/16 19 55005-1-SD-Z 5 6-9/16 3-3/4 7-1/2 5-9/16 3 4-1/2 17 55006-1-SD-Z 6 8-3/16 4-1/4 9-3/16 7 2-7/8 4-9/16 19
D
A
ADJUSTABLE
CAST IRON
BUSHING
PIPE SIZE
C
OPTIONAL (-41)
CLAMP RING
OPTIONAL (-F)
FLANGE
WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov
189
CLEANOUTS
CLEANOUTS
55000-1-SQ SERIES with -1-SQ Nikaloy Square Top
APPLICATION
For use in finished floors subject to pedestrian and light wheel traffic such as schools, hospitals and shopping malls where a square top complements construction or floor finish. Top design allows for unimpaired adjustment even as the floor is being poured.
SPECIFICATION
JOSAM 55000-1-SQ Series coated cast iron LEVELEZE®KLEENATRON®II Floor Cleanout, internal ABS cleanout plug, adjustable cast iron housing with medium-duty scoriated secured square satin Nikaloy cover.
CLEANOUTS
OPTION N/A:
-WF
A SQ.
ADJUSTABLE
-MIN
X
- MAX
Y
B
FLANGE STANDARD ON 4” -X AND 6” SIZES.
*
THREADED
ABS PLUG
D
PIPE SIZE
CAST IRON
BUSHING
C
OPTIONAL (-41)
CLAMP RING
OPTIONAL (-F)
FLANGE
FOR OUTLET TYPE SPECIFY -X, -Y or -Z
TYPE NO. PIPE SIZE A B C* D X Y LBS.
55002-1-SQ 2 5-3/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 13 55003-1-SQ 3 5-3/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 13 55004-1-SQ 4 5-3/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 14 55004-1-SQ-X 4 7 4-1/4 9-3/16 7 2 3-11/16 16 55005-1-SQ-Z 5 5-3/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 14 55006-1-SQ-Z 6 7 4-1/4 9-3/16 7 2 3-11/16 16
55000-1-12 SERIES with -1-12 Nikaloy Top Recessed for Tile
APPLICATION
For use in finished floors subject to pedestrian and light wheel traffic such as schools, hospitals and shopping malls where the recessed cover accepts matching tile to com­plement floor finish. Top design allows for unimpaired adjustment even as the floor is being poured.
SPECIFICATION
JOSAM 55000-1-12 Series coated cast iron LEVELEZE®KLEENATRON®II Floor Cleanout, internal ABS cleanout plug, adjustable cast iron housing with medium-duty scoriated secured round satin Nikaloy cover recessed for tile.
A
X
-MIN
- MAX
Y
B
FLANGE STANDARD ON 4” -X AND 6” SIZES.
*
THREADED
ABS PLUG
D
PIPE SIZE
FOR OUTLET TYPE SPECIFY -X, -Y or -Z
TYPE NO. PIPE SIZE A B C* D X Y LBS.
55002-1-12 2 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 12 55003-1-12 3 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 12 55004-1-12 4 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 13 55004-1-12-X 4 6-5/8 4-1/4 9-3/16 7 2 3-11/16 14 55005-1-12-Z 5 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 12 55006-1-12-Z 6 6-5/8 4-1/4 9-3/16 7 2 3-11/16 14
COVER RECESSED FOR TILE
ADJUSTABLE
CAST IRON
BUSHING
C
OPTIONAL (-41)
CLAMP RING
OPTIONAL (-F)
FLANGE
190
WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov