Jolly Mec BP07 Installation And Use Card

Air controller
INSTALLATION AND USE CARD
To be carefully kept by the purchaser
CONTENTS
ASSEMBLY INSTRUCTIONS FOR THE INSTALLER
1.1 Recommended assembly diagrams ..................................................................................................................................................................................................................................................................3
......................................................................................................................................................................................................................3
......................................................................................................................................................................................................................4
1.1.3 SOLUTION 3: for inserts
..........................................................................................................................................................................................................................................................................4
......................................................................................................................................................................................................................5
......................................................................................................................................................................................................................5
1.1.6 SOLUTION 6: for new fireplaces or inserts with remote control
..............................................................................................................................................................6
1.2 Controller BP07 wiring diagram
..............................................................................................................................................................................................................................................................................7
1.3 Technical characteristics
..................................................................................................................................................................................................................................................................................................8
USE AND MAINTENANCE INSTRUCTIONS FOR THE USER
1.4 Use of controller BP07 ......................................................................................................................................................................................................................................................................................................9
Read this card carefully and follow the instructions for quick installation and correct use of the fireplace.
Before starting installation, read the card carefully and follow the instructions; failure to do so could invalidate the warranty and compromise fireplace performance and safety.
This installation card is an integral and essential part of the product and must be given to the user.
It must kept in safe place and carefully consulted, as it provides important information on safety during the installation, use and maintenance stages.
Incorrect installation can cause damage and injury, for which the manufacturer cannot not be held liable.
The unit must only be used for its intended purpose. Any other use is deemed improper and therefore dangerous.
The manufacturer declines any contractual or non-contractual liability for damage caused by errors in installation or use, failure to follow the instructions contained in this card, or installation in places or rooms unsuitable for the characteristics of the product.
All rights to reproduction of this card belong to JOLLY-MEC CAMINETTI S.p.A.
The descriptions and illustrations provided in the following publication are not binding.
JOLLY-MEC CAMINETTI S.p.A. reserves the right to make any changes it deems necessary at any time.
This card cannot be given to third parties to read without the written permission of JOLLY-MEC CAMINETTI S.p.A.
The technical instructions for assembly contained in this handbook are considered basic requirements. The regulations in some countries may be more restrictive; in this case carefully comply with the regulations in the country of installation.
A
C
B D E
F
Before fitting the exchanger or positioning the fireplace, choose the required electrical assembly diagram from among those given, then prepare the necessary paths for the connection cables, obtained from passages in tubes with sheathing for electrical cables of approved types.
The fan and 230V line cables must not be inserted in the same sheathing used for the probe (or thermostat) and display cables.
1.1.1 SOLUTION 1: for new fireplaces or inserts
Components
Controller positioned under the fireplace, inside the cladding, or in the compartment obtained for the fan in already existing cladding for Universaljolly (see fireplace instructions). Display positioned at side on cladding hood.
For this important requirement, the following diagrams use the
colour RED
- - - - - -
for 230V cables and BLUE
- - - - - -
for very
low voltage cables.
In the following examples
the
RADIO FREQUENCY remote control
(an OPTIONAL accessory) is represented with n. F.
A
B
C
D
E
F
Main switch
Controller
Command and control display
Fan
Probe or thermostat
Optional remote control
IMPORTANT!
Always make sure the temperature where the controller and display are placed does not exceed 60°C.
1.1 Recommended assembly diagrams
A
C
B D E
F
A
B
D E
C
F
1.1 Recommended assembly diagrams
4
1.1.2 SOLUTION 2: for new fireplaces or inserts
Components
A
B
C
D
E
F
Main switch
Controller BP07
Command and control display
Fan
Probe or thermostat
Optional remote control
Controller positioned under the fireplace, inside or outside the cladding, or in the compartment obtained for the fan in already existing cladding for Universaljolly. Display positioned at side on the cladding plinth.
1.1.3 SOLUTION 3: for inserts
Components
A
B
C
D
E
F
Main switch
Controller BP07
Command and control display
Fan
Probe or thermostat
Optional remote control
Controller and display positioned at side on the cladding plinth. Display attached to the controller box cover with velcro (supplied); or with self-tapping screws (3.5x9.5), making sure to leave at least 5mm between the screw and the electronic board in the box.
1.1 Recommended assembly diagrams
5
A
B
C
D E
F
1.1.4 SOLUTION 4: for new fireplaces or inserts
Components
A
B
C
D
E
F
Main switch
Controller BP07
Command and control display
Fan
Probe or thermostat
Optional remote control
1.1.5 SOLUTION 5: for new fireplaces or inserts
Components
A
B
C
D
E
F
G
Main switch
Controller BP07
Command and control display
Fan
Probe or thermostat
Optional remote control
Humidifier access recess
A
D E
F
C
B
G
Controller and display away from fireplace, maintaining the maximum distances recommended in the wiring instructions.
Controller positioned in the fireplace hood, with the display positioned above it, or elsewhere. N.B.The temperatures where the controller is placed must be below 60°C.
A
DBCE
F
1.1 Recommended assembly diagrams
6
1.1.6 SOLUTION 6: for new fireplaces or inserts with remote control
Components
A
B
C
D
E
F
Main switch
Controller BP07
Command and control display
Fan
Probe or thermostat
Remote control
Controller and display both positioned under the fireplace inside the cladding; or in the fan compartment (see fireplace instructions) for Universaljolly units. Display attached to the controller box cover with velcro (supplied); or with self-tapping screws (3.5x9.5), making sure to leave at least 5mm between the screw and the electronic board in the box.
1.2 Controller BP07 wiring diagram
7
Manual
version
Automatic
version
Thermostat
Probe PT100
Fan
Control display
Earth
Connect to the earth
of the metal box
230V line
1.3 Technical characteristics
Technical characteristics
- Connection to radiofrequency RFRC (868MHz, modulation FSK).
- Connection to boiler by means of non-polarised pair 2x0.75mm, max. length 30m.
- No type of auxiliary power supply or batteries are necessary.
- Operating temperature range 0÷65°C.
- Reserve charge time in absence of connection/power of at least 8 hours.
- Permanent storage of user programmes and settings.
- The display is connected to the board by means of two non-polarised wires, through which it is fed and communicates with the board.
- The characteristics of the connection line are as follows: Number of wires: 2x0.75mm Type of cable: twin wire*
- Max. cable resistance: 2
- Polarity : polarity free
* In case of places with high electrical noise, a screened or twisted cable must be used.
Luminous signals
The board has 3 LED’s for showing operation status and any faults.
2
,5Ω
LED COLOUR OFF ON FLASHING
DL1 yellow communication not active communication active not provided for
DL2 red no fault probe fault not provided for
DL3 green no power power on not provided for
Jumper check only for service technicians
Retrofit controllers QUA/ELET AND QUA/UNIV Retrofit controllers QUA/ARIA1-2
NO jumperEOperation with PROBE Automatic Version YES jumperEOperation with THERMOSTAT Manual Version
8
1.4 Controller BP07 use
9
DAY SET
ON
Main features
The controller is arranged for control of the room air fan, for setting the optimum air delivery level. The ventilation level can be manually set by the user or in automatic mode. In automatic setting (possible in the version with temperature probe), the ventilation level is set according to the fireplace temperature. A fan operation mode is provided for also with the fireplace off, for room ventilation.
The user interface is in wired version, already arranged for the radiofrequency version. Through the user interface it is possible to set the various operation modes and identify any faults. Display of room temperature (with remote control only).
DISPLAY
- Change operation status Summer/Winter
- Display fan speed in automatic
Increase selected value
in manual programme
Decrease selected value
in manual programme
No communication with fireplace
(with remote control only)
The controller is arranged for association with the remote control.
norF
Operation programme
AU = Automatic LX = manual with ventilation
level X (1-9)
OF = Off
RF reception in progress Winter Mode (if not present the
controller is set to Summer mode)
Change operation programme Off/Manual/Automatic
1.4 Controller BP07 use
10
Operation status
Press the button to go from Summer status to Winter and vice versa:
Summer Winter 왘 Summer
Operation programme
—- —- —- —- —- SUMMER —- —- —- —- —-
OF LX (1-9) OF
OFF Manual 왘 OFF
—- —- —- —- —- WINTER —- —- —- —- —-
OF LX(1-9) AU OF
OFF Manual Automatic OFF
Press the button to go from one operation programme to another :
Setting the required ventilation level
In Manual the set ventilation level LX will appear on the right on the display, where X can assume values of 1 to 9.
Use the buttons .to modify the set value X.
Display of ventilation level in automatic (with remote control only)
Press the button for 3 seconds to display the current ventilation level (which can momentarily differ from that set, for example in automatic). The ventilation level LX will appear in the middle of the display, where X can assume values of 1 to 9.
To return to normal operation just press the button again or wait 60 seconds without pressing other buttons.
Dissipation programme
If the fireplace reaches excessive temperatures a programme called Dissipation will be automatically activated (with probe only) and signalled with the message Ht (High Temperature). This programme has priority over all the other settings, which will possibly be ignored.
NOTE!
When the contact thermostat is present on the fireplace, the fan speed “Automatic” function is not present.
1.4 Controller BP07 use
11
Associating an RFRC02 with base RFIU02 (RF installation)
To associate the display-remote control pair, proceed as described below. Note: To create the association it is necessary to operate on the display and the remote control, therefore it is advisable to keep them within reach.
1. On REMOTE CONTROL:
- Press the button for 5 seconds to access the Programming mode (indicated by the message LO).
- Press the button once and the icons and the message n Zn (No Zone) appear, with n flashing to indicate no association.
Press the button for 5 seconds until the message Ln (Link) appears.
2. On DISPLAY:
Now put the display on standby for association request, from normal operation by pressing the button once the message Inst (Install) will appear flashing.
3. On REMOTE CONTROL:
- Press the button and wait a few seconds. If the operation was successful the message LO (Link OK) appears, otherwise LE (Link Error) appears.
- In both cases it is possible to return to the initial window by pressing the button (or to exit programming completely).
In case of positive result the display automatically returns to normal operation (otherwise press or wait 60 seconds) and the new message on the remote control will be 1 Zn in place of n Zn.
Status+Operation programme Summer+OFF
Ventilation level in manual L = 5
Function Factory setting
Summary of displays and Factory settings
Quality of the RF signal and notes on position of the device (with remote control)
The quality of RF communications can be displayed at any time, in order to select the correct place of installation and guarantee correct operation of the system. In fact, the communications in RF systems can deteriorate as a result of an incorrect position inside the house. To check the quality, proceed as follows.
- Press the button for at least 3 seconds to access the Programming mode (indicated by the message LO).
- Press the button until the message X rF appears, with X flashing to indicate the communication quality level (from 0 to 4):
0 = No communication (no association/signal or positioning unsuitable) 1 = Signal present but weak (positioning not very suitable in presence of interference) 2 = Signal sufficient to guarantee correct operation 3 = Good signal 4 = Optimum signal
To return to normal operation, press the button or wait 60 seconds.
Fault signalling
In case a boiler anomaly, the message Er:XX will appear on the display in normal operation, where XX indicates the type of fault.
SM/032-GB rev. 1 01/2008