Contents
Notes ---------------------------------------------------- 2
1.Standard Configuration --------------------------------- 1
2.Overview ----------------------------------------------- 3
3.Technical Specifications -------------------------------- 6
4.Instruction -------------------------------------------- 7
5.Trouble shooting -------------------------------------- 21
6.Maitanance -------------------------------------------- 22
7.Warranty & Servicing ---------------------------------- 22
Appendix I ---------------------------------------------- 24
2
Notes
Icon Meaning
In this manual will appear some text with the below iconThe meaning as
follows
WarningImproper behavior and operation, to prevent any wrongdoing and
harm.
NoteDue to the improper operation may cause harm to the human body or product, so
special note to warn the user.Please make sure that!
Important noteTo identify the key information, general notes, noun explanation or
reference information, etc.
WEEE Sigh:This product or component part (s) shall not be considered as a general
garbage dump, please according to your area on waste treatment method for disposal of such products.
About Battery
This series of products are different types used in power supply or have a different way. There are
disposable alkaline batteries, or rechargeable batteries. Do not mixture of different types or different capacity of battery, prohibited to charge a rechargeable battery.
About Storage
When product long-term deposit or do not use, please remove products within the battery stored
separately, in order to avoid battery leakage caused by instrument damage.
To prevent electric shock, please do not open the product case, must be the company authorized by a qualified professional personnel for repair; Do not expose this product in the rain or damp environment, so as to avoid fire or click on the occurrence of danger!
Due to the laser can cause the big harm to eyes,please do not look
directly into the laser output when you use the tester.
3
Chapter 1 Standard Configuration
Please refer to the following models corresponding to the standard configuration, check whether your product accessories is complete, if lack of any items, please contact the dealer as soon as possible!
Model
JW3213 Series Pon Optical Power Meter
Items
Title
Quantity
1
JW3213 tester
1unit
2
User Manual
1pc
3
USB
1pc
4
Soft CD
1pc
5
1.5VAA Battery
3pc
Chapter 2 Overview
JW3213 Series PON Optical Power Meter target at the FTTx application and maintenance. This power meter is able to simultaneously test and estimate the signals of the voice, data and video. It is an essential and ideal tool for the construction and maintenance of the PON projects.
Features
(1).It can experiment at Voice, data and video signal synchronous measurement and display on BPON/EPON/GPON. (2)Providing simultaneous measurement for all three wavelengths on the fiber (1490nm, 1550nm,1310nm )
Used in Burst mode measurement of 1310nm upstream. ⑷.Use the software connect with PC, setting the threshold, data transfer, and calibration
the wavelength.
4
⑸.USB communication port enables data transfer to a PC.1000measurement items can be saved in JW3213 PON power meter or computer for data review.
⑹ . With optical power meter module,include8501300 1310 1490 1550 1625sixs(JW3213APJW3213Awithout850nmwavelength); With visual fault locator module
JW3213andJW3213AV) ⑺.Optical power meter and VFL with one port.(onlyJW3213A) ⑻.Optional Chinese/English display. ⑼.Offers up to 10 different threshold sets in total,Three status LEDs represent different
optical signal conditions of Pass, Warn and Fail respectively.
⑽.10 minutes Auto-off function can be activated or deactivated
⑾.Good key design,high sensitivity, greatly reducing the volume and weight of the tester. ⑿.Different models corresponding to different function, according to own use to
choose .
Chapter 3 Technical Specifications
3.1 PON module:
PON module:
JW3213
JW3213 A
JW3213 AV
JW3213A P
1310 upstream measurement
Pass Zone(nm)
1260nm1360nm
MeasurementRange(dBm )
-40dBm+10dBm
Input power(max)
15dBm
Isolation@1490/1550(dB)
>40dB
Burst mode measurement error
<±0.5dB
1490 downstream measurement
Pass Zone(nm)
1470nm1505nm
MeasurementRange(dBm )
-40dBm+10dBm
Input power(max)
15dBm
Isolation@1310/1550(dB)
>40dB
1550 downstream measurement
Pass Zone(nm)
1535nm1570nm
5
MeasurementRange(dBm )
-40dBm+20dBm
Input power(max)
25dBm
Isolation@ 1310/1490nm
>40dB
Measurement Accuracy
Connatural uncertainty(dB)
±0.5dB
Linearity(dB)
±0.1dB
Passing through insertion Loss(dB)
<1.5dB
General Information
Detector Type
InGaAs
Optical Connector
FC/SC/ST Interchangeable/2.5 universal
adapter
Fiber Type
SM 9/125um
Measurement Unit
dB/dBm/xW
Resolution (dB)
0.01dB
Operation Voltage(V)
DC 3.3V5.5V
Power Supply
3pc1.5V battery
Continuously Operation time (h)
PON 90h
PON90h OPM100h VFL50h
PON 90h VFL:50h
PON90h OPM:100h
Operation Temperature()
-10℃~60
Storage temperature()
-25℃~70
Weight(kg)
423g
425g
424g
424g
Note: The operation time of the battery are all for the instrument that do not turn on backlight, if the backlight turn on the operation time will be shorted.
3.2 Normal Optical Power Meter Module
Normal Optical Power
Meter
JW3213②
JW3213A
JW3213AP
Measurement Accuracy
6
Connatural uncertainty(dB)
None
±0.5dB
Linearity(dB)
±0.1dB
Measurement Range(dBm)
-70dBm+6dBm
General Information
Measurement Unit
None
dB/dBm
Resolution (dB)
0.01dB
Calibration Wavelength(nm)
1300/1310/ 1490/1550/1625
850/1300/1310/ 1490/1550/1625
Detector Type
InGaAs
Optical Connector
FC/SC/ST Interchangeable/2.5 universal adapter
JW3213do not have the OPM module
3.3VFL Module
VFL
JW3213③
JW3213A
JW3213AV
Output power
None
>0.5mW
Wavelength
650nm
Optical Connector
FC/SC/STInterchangeable/2.5
universal adapter
Fiber Type
SM/MM
:JW3213 without VFL module.
7
Chapter 4 Instruction
JW3213 / JW3213A two models are different between functions and the
form, detailed in this chapter, please check carefully.
1.Describtion
1- OLT/VIDEO1490nm/1550nm Down Stream
2- ONT1310nmUp Stream Port1310nm
3- VFL or OPM Port
4- Display
5- ONT1310nmUp Stream Port LEDs 6- OLT1490nm/1550nm Down Stream LEDs
1 2 3 4 5 6 7 8 11
9
10
12
13
14
8
7- Video signal LEDs (1550nm)
8- AUTOpower/off key
9-UPIn the first interface, switch visual fault location modelVFL
10- ENTER: Confirmation the function selection and saving the data.
11- MENU: PON/CW Power meter module Option
12- DOWM,In the first interface,Switch betweenVFL in continuous light
(the CW) and pulse light (HZ)
13- CANCEL:Function cancel
14- USB PORT
④:Only JW3213A and JW3213AV up/down keys for VFL function
PON Online test connection diagram
OLT PON Interface optical power test configuration diagram
OLT
ONT
……
Data Networks Analyser IXIA/Smartbits
Fiber
Fiber
Optical Splitter
9
ONT The sensitivity test configuration diagram
Data Communication
Run the CD,install USB driver software CP210x_VCP_Win2K_XP_S2K3.exe.
Then install dotNetFx40_Full_x86_x64.exe.
Connect JW3213 PON power meter to the computers port using the provided USB cable,Open the software as shown in below figure:
Upload the data
OLT
ONT
……
Data Networks Analyser IXIA/Smartbits
Fiber
Optical Splitter
1490nm
1310nm
Lamda Multiplexer
Variable Optical Attenuator
10
1Open the JW3213PON power meterfirst of all click “connect”,connect JW3213PON power meter to the computer(Click“English”to set the language of the operation interface to be English ) 2choose “Upload Data”click “Upload Test Data”sign,the saved data can be read on the computer, and saved as a file format. 3click the“Delete Test Data” button or“Clear Test Data”to delete the data.
Threshold Setting
ClickUpload threshold valueicon to read the threshold.
11
From the toolbar, select Threshold Set, and right click the Threshold to type or modify the threshold value.
Calibration
Choose Calibration tab, the user can perform user self-calibration operation also can choose Factory Reset mode. For example, the current optical power at 1310nm is -10dBm, type -10dBm in the text box of input standard power, and click Calibration tab, then finished the calibration operation at 1310nm wavelength.
Power ON/OFF
1.Power ON
Press for about two seconds to make the unit power onEnter into the PON power meter function , the unit displays as shown in below
figure:
12
As shown in above figure, the LCD will display simultaneously three wavelengths of 1310nm upstream measurement and 1490nm,1550nm downstream measurements. When optical signal is present under test, the optical channel will display power levels in dBm, when optical signal
is not available, then the optical channel will display “LOW”. “ ”indicates
10 minutes auto-off function is activated.The unit will turn itself off after
10 minutes of idle time. Press to close 10 minutes auto-off.
2.Power Off
Press key for about two seconds,to turn off the unit.
PON Power Meter module
PON power meter can simultaneously measure the PON network upstream signals
of 1310 nm, 1490 nm downstream data signal and descending video signal output power of 1550 nm
After open the instrument, Press to enter into menu operation, Press
to exit
Press or“ to choose the following settings, and press
to choose the function.
13
Use or ” to choose the required threshold value,(The thresholds rang and name have already set in the software, and also
download to the instrument, please check with the user manual of Chapter
6 data communication), For example choose threshold and name it as “a
and press“ ”.
Press“ ” back to the testing menu.
Clean the tested optic cable, connect with OLT/VIDEO port and ONT port, (SC type connector), noted with the optic adaptor type, the optical adaptor
14
will be break, and the tested value will be faulty if the un-matched adaptor connected
Pay attention to the type of the measured optical fiber connectors, does not match the
type of access instrument, may damage the instrument output optical fiber connector,and can not get the true result.
1310nm,upstream, 1490nm, 1550nm downstream, and 3 wavelength measurement at the same
time.
Eg.: The selected threshold name is “a”(-10dBm,-20dBm,-30dBm). The measured result displayed: -11dBm (Optical power) at 1310nm upstream measurements shown in above figure, as it is within -10dBm (Pass threshold)~-20dBm(Warning threshold), therefore, it means the optical signal in Pass status and the LED at 1310nm will light up with green color: If the measured result is between -20~-30dBm, it means the optical signal in Warn status and the LED at 1310nm will light up with yellow color which means the optical signal may got problems but still can be used; If the measured result is out of the range of thresholds, i.e greater than -10dBm or smaller than -30dBm, then it means the optical signal got problems, the LED at 1310nm will light up with red color. The same process be used at 1490 and 1550nm wavelengths.
15
Press ”, there will displaying saving on the screen, check with the
upper pic. The data recording series No.is 0002. press“ ” saving, and
” for cancel, and the saving recording can be checked in the “data view” under “historical data” Menu.
After finish the testing work, keep the connect port clean, so cover the
dusty-cap once finish the work.
Instructions for Normal Optical Power Meter Function
Press button to open the instrument, use ” button and
; to choose the Optical Power Meter measurement, then press
” to enter into the selected function. or Button in this case, is to choose the wavelength. Instrument only provide the test of 850nm
1300nm、1310nm、1490nm、1550nm1625nm,display “-70dBm”when without light.
Take 1310nm measurement for example:
Connect with the tested optic fiber Clean the optic Fiber end-face, and connect with the PIN port on the instrument (SC/ FC/ST adaptor), noted with the type of the optic fiber adaptor, the non-matched connecting will make the damage of the connector on the instrument and also make the faulty of the measuring result. E.g.: 1310nm measurement, after connect with the optic fiber, it will displaying
-20dBm, press“ ”, set the -20dBm as the reference value, and it will also
16
display relative value (dB), see as following:
In order to get the loss between the two measurements, do another time testing under the first relative output power. The relative value will be calculated automatically. For example the second time testing of 1310nm output power is -35dBm, the relative output power will be -15dBm.(relative output power=absolute output power-reference value -15dBm=-35.00dBm­-20.00dBm see as following:
After finishing testing, cover the dusty cap to keep the optical connector
port to be clean.
⑤:JW3213&JW3213AVwithout this function.
VFL module
During the event or break point checking of the short distance optic fiber
and pigtails we can use the VFL function.
First of all, Clean the optic Fiber end-face, and connect it them the VFL
port (FC adaptor), after open the instruments, press to activate this function, then can see the visual laser at the breaking point or the end of the
pigtails. Press to shift the CW and the Hz wavelength. And press
Ref
Absolute value
Relative value
17
again to close this function.
⑥:JW3213&JW3213AP without this function.
Other function instruction:
PON Power Meter: Relative output power measurement:
As per requirements of measurement to select the different wavelengths
and Ref settings, relative power=testing value-Ref value. Press
or to select the different wavelengths, Press“ ” to change the Ref value as shown in below figure
Threshold Selection
It offers up to 10 different threshold sets in total. There are three status LEDs in the front panel and each light indicator has three conditions of colors which represent different signal status as below: Green---Represents Pass Yellow---Represents Warning Red----Represents Fail
Behind“ThreshSel”displays selected threshold setting order number from 1~10,
and behind “Name”displays selected threshold name, press or
REF
RELATIVE VALUE
18
to select the corresponding shresholds. With using JW3213.exe software to modify the values range and names of thresholds (Detailsas explained in term 5-Data Communication.)
⑦:Threshold Selection just can be use English or figure,can not use Chinese.
Switches of measurements units
Measure the output power of the fiber use dBm or Xw, Press “ with
and to choosethe measurements units, press “ ” to
exit and cancel the current operation as shown in below figure
Switches of language
There are two language English and Chinese to Choose, Press
and to select “Language” option, Press “ ” to exit
Status LEDs-JW3213
19
and cancel the current operation.
Time setting
In item 5 have Time SettingPress and select the “Time
Set”option, and press to change year-month-date-time
respectively as shown in below figure,use and to change
the digits. After setting, press “ ” to confirm.Press “ ” to exit
and cancel the current operation.
This option is designed to review and delete saved measurements data.
Press “ Menu” to enter into menu operation, using with and
to highlight “History Data” option. There are three options in
History data:
20
⑴ .”Data View”
Under “History data”, use and to highlight “Data View”,
press “ ” to confirm and view the history data as shown in below
figure. Press “ ” to exit.
As shown in above figure, when there is no optical signal to be tested, the power level will show -40dBm at 1310nm&1550nm and -50dBm at 1550nm, when the optical signal is present, the unit will display the
corresponding tested value. “Thresh Sel 5” is the name of current
selected threshold set. 0001 here represents the current viewed data, 0002 here means the total qty of saved measurements data. Use
and to choose or change the different saved history data.
If there is no measurements is saved in the unit, it will display “No
Record”
⑵ .“Del Cur”
Under “History data”, use and to highlight “Del Cur”,
press “ ” to confirm to delete the current data as shown in below
figure.
21
“Del All
Under “History data”, use and to highlight “Del All”,
press “ ” to confirm to delete all the saved history data as
shown in below figure.
Chapter 5 Troubleshooting
Problem
Possible Cause
Solution
No display on
the LCD
1. Power Off
1. Lower Battery
1. Press to turn on
2. Change the battery
Inaccurate
measurements
1.Optical interface
is not clean
2. Improper fiber
connection
1Clean the fiber optic interface
2. Reconnect the fiber
22
Chapter 6 Maintenance
To help ensure long, trouble-free operation:
1) Always keep clean fiber-optic connectors before using, keep the unit free from oil and dust.
2) Do not use unclean, non-standard fiber-optic connector adapter, do not insert to bad fiber-optic connector interface which may cause the system out of the work.
3) Try to use one type fiber optic connector adapter.
4) After finish the testing or when the unit is unused, please cover the dust-proof cap to ensure the optical interface is clean and to avoid measurements errors caused by dust.
5) Push/pull the fiber-optic connectors carefully to avoid the scratches on the interface.
6) Clean optical connectors regularly with cleaning cotton swabs.
Chapter 7 Warranty & Servicing
Caution: Repair it in the field is NOT recommended.
1) Joinwit warrants that JW3213series of PON Optical Power Meter will be free from defects in material and workmanship for a period of 18 months. The date will be started from the date of goods receiving by original customer.
2) If any defectives happened due to quality problems of the product during the first
month(from the date of goods receiving) of warranty period, Joinwit undertakes at its own cost (including all the freight costs and import taxes ) to repair or replace or return the faulty product.
3) If any defectives happened due to quality problems of the product during the 2nd month to 18th month of warranty period, Joinwit promises to repair or replace free of
charge. But the freight cost and related taxes will be shared by both parties. Joinwit will pay the shipping cost from customer side to Joinwit and pay the import taxes in China. Customer will pay the shipping cost from Joinwit to customer side and its local import taxes accordingly.
This warranty is limited to defects in workmanship and materials and does not cover damages from accident, acts of god, neglect, wrong usage or abnormal conditions of operation.
4) Joinwit will charge corresponding fees for the cost of materials, repair and shipping in
23
conditions of below:
Defects occurred under normal use and service but out of the warranty period. Failures and damages occurred do not because of defects in material and
workmanship of products. Failures and damages occurred because of failing to comply with the Operation Instruction and necessary attention. abnormal conditions of operation or handling
Such as artificial damage, or operating in abnormal conditions of like high temperature high voltage, humidity and etc., Joinwit will charge depend on the actual failure rating.
24
Appendix I
An important message from JOINWIT
JOINWIT guarantees that any information you supply will remain confidential. By returning this card, you will automatically be notified about updates, modifications, and recalibration.
CUSTOMER SERVICE
Phone: 86-21-51591648 Fax: 86-21-51591519
joinwit@joinwit.com
www.joinwit.com
-----------------------------------------------------------------------------------------------------
Warranty Registration Card
Serial Number: Model Number: Date of Purchase:
Company Name: Company Address: TEL: FAX: E-mail: NotePlease fax this note within one month from the date of receiving units
Do you have any comments on the quality of this product or the service from Joinwit?
TEL021-51591517 FAX021-51591519 HTTPwww.joinwit.com E-mail: joinwit@joinwit.com
Loading...