INSTALLATION INSTRUCTIONS
FOR
THROUGH-THE-WALL
VENTING COMPONENTS
These instructions apply for the
including the outdoor vent terminal
for the JWF307V “Through-The-Wall”
Vented Oil Fired Water Heater.
The general installation instructions in
the manual, No. 62662 for GSW
Oil Fired Water Heaters apply, with the
exception of the applicable section
under “Venting” and the method for
“Air Adjustment”.
The instructions contained herein
must be followed in its place.
Refer to the following diagram for the identification of the vent components:
(Fig 1.)
NOTE: THE VENT COMPONENTS
MUST BE USED AS SUPPLIED
WITHOUT ANY ALTERATION.
63371
GSW Inc.
Figure 1
INTERIOR/EXTERIOR S.S. SHIELD (PART OF
VENT TERMINAL)
CONNECTOR-FLEX DUCT TO VENT TERMINAL
(PART OF VENT DUCT)
3” CLAMP
FLEX DUCT
TRANSITION PIECE
WATER HEATER TO
FLEX DUCT (PART OF
FLEX DUCT)
6” CLAMP
VENT TERMINAL
SCREEN
JWF307V
WATER HEATER
EXHAUST DUCT KIT
63320 - 5’
63321 - 10’
63322 - 20’
DUCT
VENT
TERMINAL
63377
63378
63379
63376
Page 1
LOCATION: (See Figure 2)
Locate the water heater as close as possible to an exterior wall to minimize the length of flex duct required. However, the minimum length available is 5 feet
and under no circumstances must any component be altered. Consider the direction of predominant winds and the possible snow accumulation against that side of the building.
NOTE 1
APPLY CAULKING ON
OUTSIDE
VENT TERMINATION
DEVICE
SCREEN
12
ANTICIPATED MAX.
SNOW LINE
GRADE LEVEL
5 - 1/8
INSULATION
BLOCKING
NO INSULATION
IN THIS SPACE
BLOCKING
3’ MAX.
MAX. DISTANCE
BETWEEN SUPPORTS
3’ ON LONGER RUNS
DO NOT ALTER ANY
VENT COMPONENTS.
TRANSITION PIECE
WATER HEATER TO
FLEX DUCT (PART
OF FLEX DUCT)
SEE DETAIL
FIG.5
JWF307V
WATER HEATER
NOTE 1.
IF THE EXTERIOR FACE IS ALUMINUM
OR VINYL SIDING OR ANY OTHER
SIDING WHICH MAY BE DISCOLOURED
OR AFFECTED BY FLUE GASES, A
METAL SHIELD OF AT LEAST 30” X 30”,
MUST BE PROVIDED TO COVER THIS
WALL SECTION.
Page 2