VSD Series II Variable Speed
IntelliPass and IntelliDisconnect Drive
Code No. LIT-1900796
Issued July 22, 2015
VSD Series II Variable Speed Enclosed IntelliPass and IntelliDisconnect Drives
Description
The Johnson Controls® VSD Series II
Variable Speed Enclosed IntelliPass and
IntelliDisconnect drives, powered by Eaton®
technology, provide a premier intelligent drive
integrated with a reliable bypass
configuration. The IntelliDisconnect variable
speed drive combines a premier quality drive
with a manual motor protector (MMP) and
disconnect (no bypass). The IntelliPass
bypass is a two- or three-contactor design
using the Eaton 24 VDC Series of contactors
and power supplies. The features, function,
and form allow the drive and bypass to
become an integrated design. The IntelliPass
drives come standard with an
Eaton/Cutler-Hammer® MMP integrated into
the drive and bypass design.
Refer to the VSD Series II Variable Speed
Enclosed IntelliPass and IntelliDisconnect
Drives Product Bulletin (LIT-12011814) for
important product information.
Features
• Network Connectivity for Drive and Bypass
(BACnet®, SA Bus, N2, and LON) —
allows for compatibility with current and
future Johnson Controls network
architecture
• Software Parameters That Utilize
Engineering Units Common to the HVAC
Industry — allows for quick and easy
startup using the onboard startup wizard
with engineering units transmitted over a
communications bus
• Top and Bottom Removal Conduit Plate —
provides access to cabling and
components for ease of installation
• Johnson Controls Support That Includes
Ordering, Estimating, and Project
Management Tools: Advanced Order
Management System (AOMS), Advanced
Installation Management (AIM) Tools QuickLIT, Catalog, PRESTO, and STORE
— allows users to easily identify and order
products
• Closed-Loop Control Programmed with
Engineering Units for Specific HVAC
Applications: Standard, PID, or multi-pump
— provides software parameters using
engineering units common to the HVAC
industry
• Standard TYPE 12 Keypad on all Drives
with Copy and Paste Function; Capable of
Monitoring Three Parameters
Simultaneously — allows easy transfer of
parameter settings from one drive to
another drive
• Drive Programming Capability Using
Auxiliary 24 V Power Supply (VS-AUX24V)
— allows variable speed drive
programming (including network
communication validation) prior to wiring
3-phase power to the drive
Additional IntelliPass and
IntelliDisconnect Features
•Plenum rated
• EMI/RFI Filters standard on all drives
• I/O and communication cards provide
plug-and-play functionality
• Serial communication interface that can
control both the drive and all bypass
features so that the remote operator can
fully control the motor whether the motor is
operated by the drive or the bypass
• Top and bottom conduit entry for ease of
installation
• Copy and paste keypad function that allows
you to transfer parameter settings from one
drive to another
• Keypad that displays up to nine monitored
parameters simultaneously
• Standard TYPE12 keypad on all drives
• Anti-trip DC bus regulation
• Input surge protection against voltage
spikes varistor input
• Onboard RS-485 (BACnet, N2, Modbus®)
• Onboard Ethernet-based communications
(BACnet/IP, Modbus/TCP)
• Standard I/O,6DI, 2AI, 1AO 2 Form C RO
(NO/NC), 1 Form A RO (NO)
• Hard-wired external/damper interlock
• Circuit breaker provides flexible drive
isolation configurations
• Standard DC link choke for enhanced
transient and harmonic distortion protection
• Optional fusing — fuse rating 200 kAIC
• Simplified operating menu allows for typical
programming changes
• Accommodates a wide variety of expander
boards and adapter boards
• Control logic can be powered from an
external auxiliary control panel
• DB chopper standard frames (frame 4
through frame 9) for USA application
•1.5 to 40 hp, 2.1 to 52 A, 480 VAC
•1 to 20 hp, 4.2 to 54 A, 230 VAC
•1 to 20 hp, 4.6 to 60 A, 208 VAC
Additional IntelliPass Only
Features
• HAND/OFF/AUTO and DRIVE/BYPASS
selector on keypad that simplifies control
• Two power sources for control ensures
redundancy and provides additional
ride-through capability
• Programmable Automatic Restart Options
— choose from disable; automatically
transfer to Bypass; reset drive only; or reset
drive and, if fails, then transfer to Bypass
(IntelliPass only)
• Fully rated, mechanically interlocked
contacts
• Self-healing power supplies
• Bypass circuit current interrupting rating up
to 65 kAIC without fusing
• Fully featured mechanically interlocked
bypassing featuring Eaton’s XT contactors
• Pre-engineered options to allow for custom
configurations
• Robust steel enclosure for simple
installation
Repair Information
If the VSD Series II Variable Speed Enclosed
IntelliPass and IntelliDisconnect Drives fail to
operate within their specifications, contact the
nearest Johnson Controls representative.
The performance specifications are nomina l and conf orm to accep table industr y standar ds. For ap plications a t condition s beyond th ese specification s, consult the local Johnson Controls o ffice.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2015 Johnson Controls, Inc.
www.johnsoncontrols.com
1

VSD Series II Variable Speed Enclosed IntelliPass and IntelliDisconnect Drives
(Continued)
VSD Series II Enclosed Drives Selection Chart (Frames 4 to 7)
Code Number
Base Product VS = Series II Variable Speed
Amps/hp/kW 2D1 = 2.1 A, 1 hp, 0.75 kW
Voltage 1 = 208 V
Enclosure Rating 1 = NEMA Type 1 (IP21)
Drive Style 1 = IntelliPass
Revision # B = Rev. 2 (Americas)
Separator (—)
Communications 0 = STD (BACnet/Legacy N2/Modbus)
Options 00 = None
1. 480 Volts 3-phase.
2. 230 Volts 3-phase.
3. 208 Volts 3-phase.
4. Contact your local Johnson Controls representative for product availability.
Enclosed IntelliPass and
IntelliDisconnect Drive prefix
3D4 = 3.4 A, 2 hp, 1.5 kW
4D2 = 4.2 A, 1 hp, 0.75 kW
4D6 = 4.6 A, 1 hp, 0.75 kW
5D6 = 4.8 A, 3 hp, 2.2 kW
6D8 = 6.8 A, 2 hp, 1.5 kW
7D5 = 7.5 A, 2 hp, 1.5 kW
7D6 = 7.6 A, 5 hp, 4 kW
9D6 = 9.6 A, 3 hp, 2.2 kW
011 = 10.6 A, 3 hp, 2.2 kW
011 = 11 A, 7.5 hp, 5.5 kW
014 = 14 A, 10 hp, 7.5 kW
016 = 15.2 A, 5 hp, 4 kW
017 = 16.7 A, 5 hp, 4 kW
021 = 21 A, 15 hp, 11 kW
022 = 22 A, 7.5 hp, 5.5 kW
025 = 24.2 A, 7.5 hp, 5.5 kW
027 = 27 A, 20 hp, 15 kW
028 = 28 A, 10 hp, 7.5 kW
031 = 30.8 A, 10 hp, 7.5 kW
034 = 34 A, 25 hp, 18.5 kW
040 = 40 A, 30 hp, 22 kW
042 = 42 A, 15 hp, 15 kW
047 = 46.2 A, 15 hp, 11 kW
052 = 52 A, 40 hp, 30 kW
054 = 54 A, 20 hp, 15 kW
060 = 59.4 A, 20 hp, 15 kW
065 = 65 A, 50 hp, 37 kW
068 = 68 A, 25 hp, 18.5 kW
075 = 74.8 A, 25 hp, 18.5 kW
077 = 77 A, 60 hp, 45 kW
080 = 80 A, 30 hp, 22 kW
088 = 88 A, 30 hp, 22 kW
096 = 96 A, 75 hp, 55 kW
1
2
3
104 = 104 A, 40 hp, 30 kW
2 = 230 V
4 = 480 V
2 = NEMA Type 12 (IP54)
3 = NEMA Type 3R (IP22)
2 = IntelliDisconnect
D = Rev. 2 (Canada)
S = SA Bus, CS Card (added to JC-VSD)
M1 = Manual Bypass Switch, on front door (for frames 4 to 7 IntelliPass
that includes L4 option = HMAX Pilot Lights and P6 option = third
contactor for drive isolation)
P3 = Drive Isolation Fuses, (for frames 4 to 7 IntelliPass and
IntelliDisconnect, not available with IntelliPass, P6 option)
P4 = Drive Output Contactor (IntelliDisconnect only)
P6 = Drive Isolation Contactor includes drive test switch (for frames 4 to 7
IntelliPass, not available with P3 option)
P7 = Drive Isolation Fuses and Drive Output Contactor (IntelliDisconnect
only)
P9 = Both P3 and P6 available only in Type 3R (or larger frame 8 and
frame 9 Type 12 boxes)
L3 = HMAX Pilot Lights (IntelliDisconnect only)
L4 = HMAX Pilot Lights (IntelliPass only)
V S 0 0A—0 0 0 0 0
1
1
2
3
1
2
3
2
3
1
1
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
4
4
The performance specifications are no minal and co nform t o acceptab le ind ustry standar ds. For appl ications at condition s beyond these specifica tions, consult the local Johnson Co ntrols office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2015 Johnson Controls, Inc.
www.johnsoncontrols.com
2