Description

The TEC2613-4 and TEC2613-4+PIR Temperature and Humidity Controllers are BACnet® Master-Slave/Token-Passing (MS/TP) network devices that provide control of multi-stage heating and cooling equipment, such as rooftop or self-contained units with a humidifier and/or dehumidifier.

The TEC2613-4+PIR Controller has Passive Infrared (PIR) occupancy sensing capability built into the device. This controller maximizes energy savings in high-energy usage light commercial buildings, such as schools and hotels, during occupied times by using additional setpoint strategies.

The TEC2613-4 and TEC2613-4+PIR Controllers provide exceptional temperature control in an easy-to-use and flexible package. Both models have over 20 configurable parameters, enabling the controllers to adapt to a variety of applications. The controllers also employ an embedded complete humidity solution with a unique, Proportional-Integral (PI) time-proportioning algorithm that virtually eliminates temperature offset associated with traditional, differential-based controllers.

Refer to the TEC2613-4 and TEC2613-4+PIR BACnet MS/TP Network Multi-Stage Temperature and Humidity Controllers Product Bulletin (LIT-12011692) for important product application information.

Features

embedded humidification sequence (0 to 10 VDC output) and dehumidification sequence (dry contact) — simplifies installation and reduces installation costs

onboard occupancy sensor (PIR Model) — provides energy savings without additional installation time and cost

password protection option — protects against unwanted controller tampering

backlit Liquid Crystal Display (LCD) — offers real-time control status of the environment in easy-to-read, English plain text messages with constant backlight that brightens during user interaction

simplified setpoint adjustment — enables the user to change the setpoint by simply pressing the UP/DOWN arrow keys

TEC2613-4 and TEC2613-4+PIR BACnet MS/TP Network

Temperature and Humidity Controllers

five easy-to-use interface keys — allow for easy commissioning and adjustment of the controller, and eliminate the need for

DIP switches

three Light-Emitting Diodes (LEDs) — provide fan, heating, and cooling status at a glance

one configurable digital input — provides additional input for advanced functions such as remote night setback, occupancy override, and service or filter alarms

over 20 configurable parameters — enable the controller to adapt to any application, allowing the installer parameter access without opening the cover

configurable auxiliary output — provides 24 VAC control for exhaust fans, lighting, and other auxiliary functions

Repair Information

If either the TEC2613-4 or TEC2613-4+PIR Temperature and Humidity Controller fails to operate within its specifications, replace the unit. For a replacement controller, contact the nearest Johnson Controls® representative.

Selection Chart

Code Number

Description

TEC2613-4

Multi-Stage Temperature and Humidity Controller

TEC2613-4+PIR

Multi-Stage Temperature and Humidity Controller with Onboard Occupancy Sensor

 

 

Applications

Multi-Stage Packaged Heating/Cooling Equipment with Humidifier and/or Dehumidifier

Accessories

Code Number

Description

Hx-67 Series1

Ductor Wall-Mount Humidity Sensor

TE-6361M-12

Duct-Mount Air Temperature Sensor

TE-636S-12

Strap-Mount Temperature Sensor

MS-BACEOL-0

RS485 End-of-Line Terminator

TE-6363P-12

Outside Air Temperature Sensor

TEC-3-PIR3

Cover with Occupancy Sensor

1.The humidity sensor must have a 0 to 10 VDC output. Remote wall-mounted versions may be used for remote return or room air humidity sensing, with the sensor mounted on the wall. A remote duct-mounted humidity sensor may be used for remote return air humidity sensing, with the sensor mounted on the return air duct or as a supply air humidity sensor used as a high limit protection.

2.Additional TE-636xx-x Series 10k ohm Johnson Controls® Type II Thermistor Sensors are available; refer to the TE-6300 Series Temperature Sensors Product Bulletin (LIT-216320) for more details.

3.The TEC-3-PIR Accessory Cover can be used to replace the existing cover on a non-PIR TEC2613-4 Temperature and Humidity Controller to provide occupancy sensing capability.

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2011 Johnson Controls, Inc. www.johnsoncontrols.com