Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 1-year limited parts warranty.
Standard 5-year limited compressor warranty.
LISTED
TECHNICAL
GUIDE
TECHNICAL
GUIDE
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
556723-UTG-A-0210
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be custommatched with one of UPG’s complete line of evaporator sections, with each serving a specific function. Matching air handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric heat kits are
available, if required. Add-on coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers.
FEATURES
• Performance - Efficiency levels from 13.0 SEER/11.5 EER
with a loose coil and up to 15.6 SEER/13.75 EER when coupled with a variable speed indoor blower.
• Easy to Install - Compact “slim-line” design allows for easy
installation in tight spaces. Units can be stacked.
• Lower Installation Cost - Installation time and costs are
reduced by easy power and control wiring connections. The
unit contains enough refrigerant for matching indoor coils
and 15 feet of interconnecting piping.
• Quiet Operation - Levels as low as 71 dBA. High efficiency
scroll compressor and swept wing fan design reducing operating sound to a mere whisper.
• State Of The Art Coil Technology - Micro-channel (MC2)
aluminum coil technology provides enhanced capacities and
efficiencies plus the benefit of maximum corrosion protection
especially in coastal applications (up to 7 times greater corrosion resistance than conventional copper tube and aluminum fin coils).
• Compressor Protection - The compressor is internally pro-
tected against high pressure and temperature. This is
accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the
compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor.
• Durable Cabinet - Heavy-gage steel cabinet and a tubular
base rail provide added support.
• Durable Finish - Automotive quality finish provides the ulti-
mate protection from harmful U.V. rays and rust creep ensuring long-lasting high quality appearance. A powder-paint
topcoat is applied over a baked-on primer, using a galvanized, zinc coated steel base material. The result is a finish
that has been proven in testing to provide 33% greater durability than conventional powder-coat finishes.
• Aesthetic - Powder paint “Champagne” Color provides an
attractive retail finish.
• Low Maintenance - Long life permanently lubricated motor-
bearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connec-
tions and a single panel covering the electrical controls make
for easy servicing of the unit.
• Secured Service Valve - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
• Other Features:
- Factory supplied filter drier
- High pressure switch, low pressure switch
- Accumulator and crankcase heater in all sizes
- Up to 200’ line set out of the box
- Zero lot line clearances (6” clearance in either direction)
• Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
556723-UTG-A-0210
B
C
A
Physical and Electrical Data
MODEL
TCHD30
S43S3
Unit Supply Voltage208-230V, 3I 60Hz460V, 3I 60Hz
Multi-Stage CompressorNoNoNoNoNoNoNoNo
Compressor Type Scroll ScrollScrollScrollScrollScrollScrollScroll
Compressor Amps
Rated Load8.412.816.015.75.26.47.77.8
Locked Rotor58.095.0120.0110.028.045.050.052.0
Crankcase HeaterYesYesYesYesYesYesYesYes
Fan Diameter Inches2323232323232323
Rated HP1 / 41 / 41 / 41 / 41 / 41 / 41 / 41 / 4
Fan Motor
Rated Load Amps1.451.451.451.450.800.800.800.80
Nominal RPM850850850850850850850850
Face Area Sq. Ft.11.9611.9613.9613.9611.9611.9613.9613.96
Coil
Rows Deep11111111
Fins / Inches2323232323232323
Max. Length200200200200200200200200
Max. Lift6565656565656565
4
Refrigerant Lines
Max. Drop150150150150150150150150
Liquid Line Set OD (Field Installed)3 / 83 / 83 / 83 / 83 / 83 / 83 / 83 / 8
Vapor Line Set OD (Field Installed)3 / 43 / 47 / 87 / 83 / 43 / 47 / 87 / 8
Unit Charge (Lbs. - Oz.)
5
4 - 04 - 85 - 55 - 64 - 04 - 85 - 55 - 6
Charge Per Foot, Oz.0.680.680.700.700.680.680.700.70
Operating Weight Lbs.195215240250195215240250
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. When more than 50 feet of interconnecting tubing and more than 30 feet of vertical lift is used, consult the Application Data (part number
247077). For long-line applications, interconnecting lines over 100 feet must be installed with liquid line solenoid.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add
or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
TCHD36
S43S3
TCHD48
S43S3
TCHD60
S43S3
TCHD30
S44S3
TCHD36
S44S3
TCHD48
S44S3
TCHD60
S44S3
187 to 252432 to 532
2030353515151515
1520252515151515
All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.
.
Unit
Model
A
(Inches)
1
BCLiquidVapor
3037-1/8 17-1/8 44-5/8
3637-1/8 17-1/8 44-5/8
4843-1/8 17-1/8 44-5/8
6043-1/8 17-1/8 44-5/8
Dimensions
Refrigerant Connection
Service Valve Size
3/4”
3/8”
7/8”
1. Including Fan Guard.
2Johnson Controls Unitary Products
556723-UTG-A-0210
System Charge for Various Matched Systems
Outdoor Unit TCHD30S4(3,4)S3TCHD36S4(3,4)S3TCHD48S4(3,4)S3TCHD60S4(3,4)S3
Required Orifice or TXV
Factory Charge, lbs-oz4 - 04 - 85 - 55 - 6
1
1TVM4G11TVM4G11TVM4J11TVM4J1
Indoor Coil
AHP24 ––––
AHP36 1612––
AHP/SHP60 ––11–
AHX18––––
AHX24––––
AHX3010–––
AHX361612––
AHX422722––
AHX48262211–
AHX60–271613
AV24 ––––
AV36 1612––
AV/SV48 –2211–
AV/SV60 ––118
F*FP030 0–––
F*FP036 84––
F*FP040 107––
F*FP042 –7––
F*FP048 –1611–
F*FP060 ––16–
F*FV060 –8118
F6FP018––––
F6FP024––––
F6FP03010–––
F6FP036107––
F6FP0422016––
F6FP04810711–
F6FP060– 271613
FC/MC/PC18 ––––
FC/MC/PC24 ––––
FC/MC/PC30 2–––
FC/MC/PC32 106––
FC/MC/PC35 06––
FC/MC/PC36 30––
FC/MC/PC37 1612––
FC/MC/PC42 31––
FC/MC/PC43 160––
FC/MC/PC48 27220–
FC/MC/PC60 ––10–
FC/MC62 ––160
HC18 ––––
HC30 7–––
HC36 106––
HC42 1612––
HC60 –70–
HD24 ––––
HD36 1411––
HD48 –3324–
HD60 ––3022
UC18 ––––
UC24 ––––
For notes see Page 4.
2,3
Additional Charge, oz
Johnson Controls Unitary Products3
556723-UTG-A-0210
System Charge for Various Matched Systems (Continued)
Outdoor Unit TCHD30S4(3,4)S3TCHD36S4(3,4)S3TCHD48S4(3,4)S3TCHD60S4(3,4)S3
Required Orifice or TXV
Factory Charge, lbs-oz4 - 04 - 85 - 55 - 6
1
1TVM4G11TVM4G11TVM4J11TVM4J1
Indoor Coil
UC30 3–––
UC36 41––
UC42 30––
UC48 21176–
UC60 ––11–
FOOTNOTES:
1. For applications requiring a TXV use 1TVM series kit.
2. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
3. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For TXV matches requiring additional charge, the refrigerant needs to be weighed in for specific coil match and lineset length.
2,3
line tubing.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
AHX6024–190557.540.213.0011.00
F6FP06024–171056.538.713.0011.00
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
COOLING
NET MBH
SEEREER
Johnson Controls Unitary Products5
556723-UTG-A-0210
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.