Johnson Controls S1-TTSCC01, S1-TCZCB01, S1-TCZSD01, S1-TCZSN01 Technical Manual

Page 1
ZONING COMMUNICATING CONTROL ZONING COMMUNICATING MODELS:
S1-TTSCC01, S1-TCZCB01, S1-TCZSD01, S1-TCZSN01
TECHNICAL GUIDE
Energy Saver
885616-UTG-A-0812
DESCRIPTION
Johnson Controls, Unitary Products specializes in creating a customized home comfort system tailored to the homeowner's needs with our broad selection of residentia l heating and cool­ing products. The Communicating Control System is the ulti­mate control center for all of your system components. When you add a Touch Screen Communicating Control to a compati­ble modulating variable-speed furnace or air handler, and a pre­mium air-conditioner or heat pump, you'll enjoy longer heating and cooling cycles at lower fan speeds for a more consistent temperature throughout your home, better humidity control, as well as a more energy-efficient comfort system.
The communicating zoning control is the ultimate zoning sys­tem in the industry. It features a color touch screen LCD that can also be used as a zoning sensor to satisfy both tempera­ture and humidity setpoints, making it the sole zoning system in the market to deliver optimum comfort to the homeowner. The communicating zoning system does not require the use of a bypass damper.
WARRANTY
Standard 5-year limited parts warranty.
FEATURES & BENEFITS
The touch screen zoning communicating control offers the same features listed in the non-zoning product with the fo llow­ing additions.
• Up to 6 zones of control with a single zone panel
• Intuitive on-screen prompts for ease of service and installa­tion
• Fan airflow adjustment by zone to compensate for duct work variability
• 4 wire installation from each component in the system
• The color touch screen is designed to be used as a master and a zoning sensor.
• Zoning system designed to provide optimum comfort based on achieving both temperature and humidity setpoints
• Complete system integration to include whole house humidi­fier, whole house dehumidifier, ventilation system, whole house air cleaners, and UVC lights. All these components are controlled from the touch screen zoning commun icating control.
• Programmable fan per zone
• Damper flexibility
• Power open / power close dampers (required when not using a bypass damper)
• Normally open dampers
• Normally closed damper
• Bypass damper is optional
• 3 communicating zone sensors to choose from:
• Touch Screen Sensor - ability to monitor/adjust all zones' information - Ability to control the zone's temperature and humidity levels.
• Zone Display - allows for temperature and fan adjustability
• Zone Sensor
• Indoor air quality pop up reminders
• Quick Heat & Quick Cool functionality
• Easy timed temperature and schedule override
• Multiple schedules that can be assigned to a calendar year
• Simplified vacation scheduling
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Page 2
885616-UTG-A-0812
MODEL NUMBER NOMENCLATURE Touch Screen Master & Sensor
S1 - T TS C C 01 A
S1 Source 1
T Tag in a bag
TS Touch Screen
C Communicating C Control
01 1st Generation
A Revision A
Zone Display
S1 - T C ZS D 01 A
S1 Source 1
T Tag in a bag C Communicating
ZS Zone Sensor
DWith Display
01 1st Generation
A Revision A
Zone Panel
S1 - T C ZCB 01 A
S1 Source 1
T Tag in a bag C Communicating
ZCB Zone Control Board
01 1st Generation
A Revision A
Zone Sensor
S1 - T C ZS N 01 A
S1 Source 1
T Tag in a bag C Communicating
ZS Zone Sensor
NNo Display
01 1st Generation
A Revision A
PRODUCT DATA INFORMATION
Compatible Communicating Products
Model Description YORK COLEMAN LUXAIRE
Air Conditioning CZF, CZH AC6, AC8 AL6, AL8 Heat Pumps YZF, YZH HC6, HC8 HL6, HL8 Gas Furnaces YPLC, YP9C CPLC, CP9C LPLC, LP9C Air Handlers MV, AV*, AHV MV, AV*, AHV MV, AV*, AHV
Physical Characteristics
Dimensions:
See drawing
Appearance:
Plastic, white color, textured
Electrical Characteristics/Communication
Input Volts/Amps 24VAC:
Each device in the communicating system has a four-pin con­nector labeled A+, R, C, B-. It is recommended that the follow­ing color code be used when wiring each device:
A+ Green = Data A+ R Red = 24VAC (Hot) C Black = 24VAC (Com) B- White = Data B-
Environmental Requirements
Operating Temperature/Relative Humidity:
User interface and all sensors: 32F to 104F / 0C to 40C, 95% RH non-condensing.
Storage Temperature/Relative Humidity:
User interface: -40F to 134F /-40C to 56.7C, 95% RH non-con­densing.
Wiring Requirements
Power supply:
Dedicated 24VAC, 40 va, 60 Hz, via indoor equipment A+, R, C, B- Connector. Isolated transformer, field supplied.
Wiring material:
Standard thermostat wire 18 to 24 gauge.
Feature Specifications
• Temperature set point range: 40F to 90F / 4.4C to 32.2C
• Separate heat and cool setpoints
• Programming days: 7 day
• Programming periods: 2 Periods: Day, Away 3 Periods: Day, Away, Sleep 4 Periods: Awake, Away, Return, Sleep
• Non-Programmable
• Auto changeover (may be disabled)
• Programmable fan (installer selectable)
• Humidity Sensor Offsets
• Smart Recovery (in heating and cooling)
• Copy functions: Copy period, day and zone
• Permanent memory
• Humidity display and control
• Temperature sensor offsets (indoor and outdoor)
2 Johnson Controls Unitary Products
Page 3
PRODUCT DIMENSIONS
5.50
.93
4.36
1.38
Touch Screen Communicating Control Zoning Master & Sensor
885616-UTG-A-0812
EQUIPMENT
Equipment
PART NUMBER DESCRIPTION
S1-TTSCC01 Touch Screen Communicating Control Master & Sensor S1-TCZCB01 Communicating Control Zone Panel S1-TCZSD01 Communicating Control Zone Display S1TCZSN01 Communicating Control Zone Sensor
Repair Parts
PART NUMBER DESCRIPTION
S1-02815904000 Face Plate (Rev A) S1-02815904101 Face Plate (Rev B) S1-02815905000 Rear Housing S1-02815906000 Mounting Plate
Optional Accessories
PART NUMBER DESCRIPTION
S1-02815909000 Hard Surface Mounting Plate and Decorative Backplate S1-03102965000 USB Adapter S1-02542694000 Wire Harness S1-CVENTDEH01 ERV/HRV, Ventilation Control Damper and Whole Home Dehumidifier Auxiliary Board S1-02543570000 6’ Service Wire Harness
Johnson Controls Unitary Products 3
Page 4
885616-UTG-A-0812
Zone Dampers
APPLICATION PART NUMBER DESCRIPTION
Round Dampers
Slip-In Round Damper
Rectangular Bottom Mount Dampers
Rectangular Bottom Mount Dampers
Continued on next page.
S1-RDM06 DMPR,ZONING,RND,24V,PWR OPN-CLS,6" S1-RDM07 DMPR,ZONING,RND,24V,PWR OPN-CLS,7" S1-RDM08 DMPR,ZONING,RND,24V,PWR OPN-CLS,8" S1-RDM09 DMPR,ZONING,RND,24V,PWR OPN-CLS,9" S1-RDM10 DMPR,ZONING,RND,24V,PWR OPN-CLS,10" S1-RDM12 DMPR,ZONING,RND,24V,PWR OPN-CLS,12" S1-RDM14 DMPR,ZONING,RND,24V,PWR OPN-CLS,14" S1-RDM16 DMPR,ZONING,RND,24V,PWR OPN-CLS,16" S1-RDM18 DMPR,ZONING,RND,24V,PWR OPN-CLS,18" S1-RDM20 DMPR,ZONING,RND,24V,PWR OPN-CLS,20" S1-RRM04 DMPR,ZONING,RETRO-RND,24V,PWR OPN-CLS,4" S1-RRM05 DMPR,ZONING,RETRO-RND,24V,PWR OPN-CLS,5" S1-RRM06 DMPR,ZONING,RETRO-RND,24V,PWR OPN-CLS,6" S1-RRM07 DMPR,ZONING,RETRO-RND,24V,PWR OPN-CLS,7"
S1-RRM08 DMPR,ZONING,RETRO-RND,24V,PWR OPN-CLS,8" S1-ZDMB0808 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X8 S1-ZDMB0810 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X10 S1-ZDMB0812 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X12 S1-ZDMB0814 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X14 S1-ZDMB0816 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X16 S1-ZDMB0818 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X18 S1-ZDMB0820 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X20 S1-ZDMB0822 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X22 S1-ZDMB0824 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X24 S1-ZDMB1010 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,10X10 S1-ZDMB1012 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,10X12 S1-ZDMB1014 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,10X14 S1-ZDMB1016 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,10X16 S1-ZDMB1018 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,10X18 S1-ZDMB1020 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,10X20 S1-ZDMB1022 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,10X22 S1-ZDMB1024 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,10X24 S1-ZDMB1212 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,12X12 S1-ZDMB1214 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,12X14 S1-ZDMB1216 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,12X16 S1-ZDMB1218 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,12X18 S1-ZDMB1220 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,12X20 S1-ZDMB1414 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,14X14 S1-ZDMB1416 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,14X16 S1-ZDMB1418 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,14X18 S1-ZDMB1420 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,14X20 S1-ZDMB1616 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,16X16 S1-ZDMB1618 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,16X18 S1-ZDMB1620 DMPR ,ZONING,RECT,24V,PWR OPN-CLS,16X20
4 Johnson Controls Unitary Products
Page 5
Zone Dampers (Continued)
APPLICATION PART NUMBER DESCRIPTION
Rectangular Side Mount Dampers
Barometric By-Pass Dampers
885616-UTG-A-0812
S1-ZDMS0808 DMPR,ZONING,RECT,24V,PWR OPN-CLS,8X8 S1-ZDMS1008 DMPR,ZONING,RECT,24V,PWR OPN-CLS,10X8 S1-ZDMS1010 DMPR,ZONING,RECT,24V,PWR OPN-CLS,10X10 S1-ZDMS1208 DMPR,ZONING,RECT,24V,PWR OPN-CLS,12X8 S1-ZDMS1210 DMPR,ZONING,RECT,24V,PWR OPN-CLS,12X10 S1-ZDMS1212 DMPR,ZONING,RECT,24V,PWR OPN-CLS,12X12 S1-ZDMS1408 DMPR,ZONING,RECT,24V,PWR OPN-CLS,14X8 S1-ZDMS1410 DMPR,ZONING,RECT,24V,PWR OPN-CLS,14X10 S1-ZDMS1412 DMPR,ZONING,RECT,24V,PWR OPN-CLS,14X12 S1-ZDMS1414 DMPR,ZONING,RECT,24V,PWR OPN-CLS,14X14 S1-ZDMS1608 DMPR,ZONING,RECT,24V,PWR OPN-CLS,16X8 S1-ZDMS1610 DMPR,ZONING,RECT,24V,PWR OPN-CLS,16X10 S1-ZDMS1612 DMPR,ZONING,RECT,24V,PWR OPN-CLS,16X12 S1-ZDMS1614 DMPR,ZONING,RECT,24V,PWR OPN-CLS,16X14 S1-ZDMS1616 DMPR,ZONING,RECT,24V,PWR OPN-CLS,16X16
S1-SPRD08 DMPR,ZONING,RND,BYPASS,BARO,8" S1-SPRD10 DMPR,ZONING,RND,BYPASS,BARO,10"
S1-SPRD12 DMPR,ZONING,RND,BYPASS,BARO,12" S1-SPRD1208 DMPR,ZONING,RECT,BYPASS,BARO,12X8 S1-SPRD1210 DMPR,ZONING,RECT,BYPASS,BARO,12X10 S1-SPRD1212 DMPR,ZONING,RECT,BYPASS,BARO,12X12
Johnson Controls Unitary Products 5
Page 6
NOTES
Subject to change without notice. Published in U.S.A. 885616-UTG-A-0812 Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: Nothing
York International Corp.
5005 York Drive
Norman, OK 73069
Loading...