Johnson Controls S1-TTSCC01, S1-TCZCB01, S1-TCZSD01, S1-TCZSN01 Technical Manual

ZONING COMMUNICATING CONTROL ZONING COMMUNICATING MODELS:
S1-TTSCC01, S1-TCZCB01, S1-TCZSD01, S1-TCZSN01
TECHNICAL GUIDE
Energy Saver
885616-UTG-A-0812
DESCRIPTION
Johnson Controls, Unitary Products specializes in creating a customized home comfort system tailored to the homeowner's needs with our broad selection of residentia l heating and cool­ing products. The Communicating Control System is the ulti­mate control center for all of your system components. When you add a Touch Screen Communicating Control to a compati­ble modulating variable-speed furnace or air handler, and a pre­mium air-conditioner or heat pump, you'll enjoy longer heating and cooling cycles at lower fan speeds for a more consistent temperature throughout your home, better humidity control, as well as a more energy-efficient comfort system.
The communicating zoning control is the ultimate zoning sys­tem in the industry. It features a color touch screen LCD that can also be used as a zoning sensor to satisfy both tempera­ture and humidity setpoints, making it the sole zoning system in the market to deliver optimum comfort to the homeowner. The communicating zoning system does not require the use of a bypass damper.
WARRANTY
Standard 5-year limited parts warranty.
FEATURES & BENEFITS
The touch screen zoning communicating control offers the same features listed in the non-zoning product with the fo llow­ing additions.
• Up to 6 zones of control with a single zone panel
• Intuitive on-screen prompts for ease of service and installa­tion
• Fan airflow adjustment by zone to compensate for duct work variability
• 4 wire installation from each component in the system
• The color touch screen is designed to be used as a master and a zoning sensor.
• Zoning system designed to provide optimum comfort based on achieving both temperature and humidity setpoints
• Complete system integration to include whole house humidi­fier, whole house dehumidifier, ventilation system, whole house air cleaners, and UVC lights. All these components are controlled from the touch screen zoning commun icating control.
• Programmable fan per zone
• Damper flexibility
• Power open / power close dampers (required when not using a bypass damper)
• Normally open dampers
• Normally closed damper
• Bypass damper is optional
• 3 communicating zone sensors to choose from:
• Touch Screen Sensor - ability to monitor/adjust all zones' information - Ability to control the zone's temperature and humidity levels.
• Zone Display - allows for temperature and fan adjustability
• Zone Sensor
• Indoor air quality pop up reminders
• Quick Heat & Quick Cool functionality
• Easy timed temperature and schedule override
• Multiple schedules that can be assigned to a calendar year
• Simplified vacation scheduling
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
885616-UTG-A-0812
MODEL NUMBER NOMENCLATURE Touch Screen Master & Sensor
S1 - T TS C C 01 A
S1 Source 1
T Tag in a bag
TS Touch Screen
C Communicating C Control
01 1st Generation
A Revision A
Zone Display
S1 - T C ZS D 01 A
S1 Source 1
T Tag in a bag C Communicating
ZS Zone Sensor
DWith Display
01 1st Generation
A Revision A
Zone Panel
S1 - T C ZCB 01 A
S1 Source 1
T Tag in a bag C Communicating
ZCB Zone Control Board
01 1st Generation
A Revision A
Zone Sensor
S1 - T C ZS N 01 A
S1 Source 1
T Tag in a bag C Communicating
ZS Zone Sensor
NNo Display
01 1st Generation
A Revision A
PRODUCT DATA INFORMATION
Compatible Communicating Products
Model Description YORK COLEMAN LUXAIRE
Air Conditioning CZF, CZH AC6, AC8 AL6, AL8 Heat Pumps YZF, YZH HC6, HC8 HL6, HL8 Gas Furnaces YPLC, YP9C CPLC, CP9C LPLC, LP9C Air Handlers MV, AV*, AHV MV, AV*, AHV MV, AV*, AHV
Physical Characteristics
Dimensions:
See drawing
Appearance:
Plastic, white color, textured
Electrical Characteristics/Communication
Input Volts/Amps 24VAC:
Each device in the communicating system has a four-pin con­nector labeled A+, R, C, B-. It is recommended that the follow­ing color code be used when wiring each device:
A+ Green = Data A+ R Red = 24VAC (Hot) C Black = 24VAC (Com) B- White = Data B-
Environmental Requirements
Operating Temperature/Relative Humidity:
User interface and all sensors: 32F to 104F / 0C to 40C, 95% RH non-condensing.
Storage Temperature/Relative Humidity:
User interface: -40F to 134F /-40C to 56.7C, 95% RH non-con­densing.
Wiring Requirements
Power supply:
Dedicated 24VAC, 40 va, 60 Hz, via indoor equipment A+, R, C, B- Connector. Isolated transformer, field supplied.
Wiring material:
Standard thermostat wire 18 to 24 gauge.
Feature Specifications
• Temperature set point range: 40F to 90F / 4.4C to 32.2C
• Separate heat and cool setpoints
• Programming days: 7 day
• Programming periods: 2 Periods: Day, Away 3 Periods: Day, Away, Sleep 4 Periods: Awake, Away, Return, Sleep
• Non-Programmable
• Auto changeover (may be disabled)
• Programmable fan (installer selectable)
• Humidity Sensor Offsets
• Smart Recovery (in heating and cooling)
• Copy functions: Copy period, day and zone
• Permanent memory
• Humidity display and control
• Temperature sensor offsets (indoor and outdoor)
2 Johnson Controls Unitary Products
Loading...