ZONING COMMUNICATING CONTROL
ZONING COMMUNICATING MODELS:
S1-TTSCC01, S1-TCZCB01, S1-TCZSD01,
S1-TCZSN01
TECHNICAL
GUIDE
TECHNICAL
GUIDE
Energy Saver
885616-UTG-A-0812
DESCRIPTION
Johnson Controls, Unitary Products specializes in creating a
customized home comfort system tailored to the homeowner's
needs with our broad selection of residentia l heating and cooling products. The Communicating Control System is the ultimate control center for all of your system components. When
you add a Touch Screen Communicating Control to a compatible modulating variable-speed furnace or air handler, and a premium air-conditioner or heat pump, you'll enjoy longer heating
and cooling cycles at lower fan speeds for a more consistent
temperature throughout your home, better humidity control, as
well as a more energy-efficient comfort system.
The communicating zoning control is the ultimate zoning system in the industry. It features a color touch screen LCD that
can also be used as a zoning sensor to satisfy both temperature and humidity setpoints, making it the sole zoning system in
the market to deliver optimum comfort to the homeowner. The
communicating zoning system does not require the use of a
bypass damper.
WARRANTY
Standard 5-year limited parts warranty.
FEATURES & BENEFITS
The touch screen zoning communicating control offers the
same features listed in the non-zoning product with the fo llowing additions.
• Up to 6 zones of control with a single zone panel
• Intuitive on-screen prompts for ease of service and installation
• Fan airflow adjustment by zone to compensate for duct work
variability
• 4 wire installation from each component in the system
• The color touch screen is designed to be used as a master
and a zoning sensor.
• Zoning system designed to provide optimum comfort based
on achieving both temperature and humidity setpoints
• Complete system integration to include whole house humidifier, whole house dehumidifier, ventilation system, whole
house air cleaners, and UVC lights. All these components
are controlled from the touch screen zoning commun icating
control.
• Programmable fan per zone
• Damper flexibility
• Power open / power close dampers (required when not using
a bypass damper)
• Normally open dampers
• Normally closed damper
• Bypass damper is optional
• 3 communicating zone sensors to choose from:
• Touch Screen Sensor - ability to monitor/adjust all zones'
information - Ability to control the zone's temperature and
humidity levels.
• Zone Display - allows for temperature and fan adjustability
• Zone Sensor
• Indoor air quality pop up reminders
• Quick Heat & Quick Cool functionality
• Easy timed temperature and schedule override
• Multiple schedules that can be assigned to a calendar year
• Simplified vacation scheduling
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Page 2
885616-UTG-A-0812
MODEL NUMBER NOMENCLATURE
Touch Screen Master & Sensor
S1 - T TS C C 01 A
S1Source 1
TTag in a bag
TSTouch Screen
CCommunicating
CControl
011st Generation
ARevision A
Zone Display
S1 - T C ZS D 01 A
S1Source 1
TTag in a bag
CCommunicating
ZSZone Sensor
DWith Display
011st Generation
ARevision A
Zone Panel
S1 - T C ZCB 01 A
S1Source 1
TTag in a bag
CCommunicating
ZCBZone Control Board
011st Generation
ARevision A
Zone Sensor
S1 - T C ZS N 01 A
S1Source 1
TTag in a bag
CCommunicating
ZSZone Sensor
NNo Display
011st Generation
ARevision A
PRODUCT DATA INFORMATION
Compatible Communicating Products
Model DescriptionYORKCOLEMANLUXAIRE
Air ConditioningCZF, CZHAC6, AC8AL6, AL8
Heat PumpsYZF, YZHHC6, HC8HL6, HL8
Gas FurnacesYPLC, YP9CCPLC, CP9CLPLC, LP9C
Air HandlersMV, AV*, AHVMV, AV*, AHVMV, AV*, AHV
Physical Characteristics
Dimensions:
See drawing
Appearance:
Plastic, white color, textured
Electrical Characteristics/Communication
Input Volts/Amps 24VAC:
Each device in the communicating system has a four-pin connector labeled A+, R, C, B-. It is recommended that the following color code be used when wiring each device:
A+ Green = Data A+
R Red = 24VAC (Hot)
C Black = 24VAC (Com)
B- White = Data B-
Environmental Requirements
Operating Temperature/Relative Humidity:
User interface and all sensors: 32F to 104F / 0C to 40C, 95%
RH non-condensing.
Storage Temperature/Relative Humidity:
User interface: -40F to 134F /-40C to 56.7C, 95% RH non-condensing.
Wiring Requirements
Power supply:
Dedicated 24VAC, 40 va, 60 Hz, via indoor equipment A+, R, C,
B- Connector. Isolated transformer, field supplied.
Wiring material:
Standard thermostat wire 18 to 24 gauge.
Feature Specifications
• Temperature set point range: 40F to 90F / 4.4C to 32.2C
Touch Screen Communicating Control Zoning Master & Sensor
885616-UTG-A-0812
EQUIPMENT
Equipment
PART NUMBER DESCRIPTION
S1-TTSCC01 Touch Screen Communicating Control Master & Sensor
S1-TCZCB01Communicating Control Zone Panel
S1-TCZSD01Communicating Control Zone Display
S1TCZSN01Communicating Control Zone Sensor
Repair Parts
PART NUMBERDESCRIPTION
S1-02815904000 Face Plate (Rev A)
S1-02815904101Face Plate (Rev B)
S1-02815905000 Rear Housing
S1-02815906000 Mounting Plate
Optional Accessories
PART NUMBERDESCRIPTION
S1-02815909000Hard Surface Mounting Plate and Decorative Backplate
S1-03102965000USB Adapter
S1-02542694000Wire Harness
S1-CVENTDEH01ERV/HRV, Ventilation Control Damper and Whole Home Dehumidifier Auxiliary Board
S1-025435700006’ Service Wire Harness