Johnson Controls RIBX243PA, RIBX243PF Data Sheet

0 (0)
Johnson Controls RIBX243PA, RIBX243PF Data Sheet

RELAY & AC CURRENT SWITCH COMBOS

RIBX243PF

RIBX243PA

Enclosed Internal Fixed .50-20 Amp AC Sensor

Enclosed Internal Adjustable .50-20 Amp AC

+ Relay 20 Amp 3PST-N/O with 24 Vac/dc Coil

Sensor + Relay 20 Amp 3PST-N/O with

 

24 Vac/dc Coil

 

Blu - N/O

 

Blu - N/O

 

Yel - N/O

 

Yel - N/O

 

Org - N/O

24 Vac/dc Comm

Org - N/O

Sensor Feedback

Current Sensor Status

 

(Orange WIres)

 

 

Blu - N/O

 

Blu - N/O

 

Yel - N/O

 

Yel - N/O

 

Org - N/O

24 Vac/dc Comm

Org - N/O

Sensor Feedback

Current Sensor Status

 

(Orange WIres)

 

Made in USA

Meets

Buy American

of ARRA 2009

SPECIFICATIONS

FUNCTIONAL DEVICES CERTIFIED FOR USE WITH ECMS

# Relays & Contact Type:

One (1) 3PST Continuous Duty Coil

Contact Ratings:

Expected Relay Life:

10 million cycles minimum mechanical

20 Amp Resistive @ 300 Vac, 28 Vdc

Operating Temperature:

-30 to 140° F

20 Amp Ballast @ 277-480 Vac

Humidity Range:

5 to 95% (noncondensing)

Not rated for Electronic Ballast

Operate Time: 20ms

15 Amp Resistive @ 600 Vac

Relay Status: Red LED On = Activated

770 VA Pilot Duty @ 120 Vac, 1 Phase

Dimensions: 4.00˝ x 4.00˝ x 1.80˝ with .50˝ NPT Nipple

1158 VA Pilot Duty @ 240 Vac, 1 Phase

Wire Length: 16˝, 600V Rated

1110 VA Pilot Duty @ 277 Vac, 1 Phase

Approvals: UL Listed, UL916, C-UL

1640 VA Pilot Duty @ 480 Vac, 1 Phase

 

California State Fire Marshal

1466 VA Pilot Duty @ 240 Vac, 3 Phase

Housing Rating: UL Accepted for Use in Plenum, NEMA 1

2112 VA Pilot Duty @ 480 Vac, 3 Phase

Gold Flash: No

Heavy Pilot Duty @ 600 Vac

Override Switch: No

7.5 HP @ 480 Vac, 3 Phase

Coil Current:

Coil Voltage Input:

5 HP @ 240 Vac, 3 Phase

3 HP @ 480-600 Vac, 1 Phase

210 mA @ 24 Vac

24 Vac/dc ; 50-60 Hz

2 HP @ 240-277 Vac, 1 Phase

154 mA @ 30 Vdc

Drop Out = 3 Vac / 3.8 Vdc

1 HP @ 120 Vac, 1 Phase

 

Pull In = 20 Vac / 22 Vdc

 

Sensor Type: Internal, with contact status Current sensing on orange wires

Sensor Threshold: Fixed, .5 Amps (RIBX243PF) Adjustable, .50-20 Amps (RIBX243PA)

Sensor Range: .50-20 Amps

Sensor Contact:

Solid State Contact

30 Vac/dc, .4 Amp Max.

When current sensor status is off (open), leakage <30 uA @ 30Vac/dc

When current sensor status is on (closed), voltage drop

<.3 Vac/dc @ .1 Amp

<1.6 Vac/dc @ .4 Amp

Notes:

Order Normally Closed by adding “-NC” to end of model number