Johnson Controls M9106 Series Installation Instructions Manual

Installation Instructions M9106-xGx-2
9
0
0
60
30
0
9
0
3
0
6
0
Anti-rotation
Bracket
Coupler
Set Screw
Shaft
Center
Coupler
A
Damper
Frame
or Duct
Gear Release
“A” is the distance from the center of the holes in the anti-rotation bracket to the center of the shaft. (See Table 1.)
Note:
Shaft Diameter
1/2 in.
3/8 in.
Issue Date June 30, 2014
M9106-xGx-2 Series Electric
Non-Spring Return Actuators
IMPORTANT: Use this M9106-xGx-2 Series
actuator only as an operating control. Where failure or malfunction of the this M9106-xGx-2 actuator could lead to personal injury or property damage t o the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or prot ect against failure or malfunction of the M9106-xGx-2 Series actuator.
Utiliser ce M9106-xGx-2 Series actuator uniquement en tant que dispositif de contrôle de fonctionnement. Lorsqu'une défaillance ou un dysfonctionnem ent du M9106-xGx-2 actuator risque de provoquer des blessures ou d'endommager l'équipement contrôlé ou un autre équipement, la conception du système de contrôle doit intégrer des dispositifs de prot ection supplémentaires. Veiller dans ce cas à intégrer de façon permanente d'autres dispositifs, tels que des systèmes de supervision ou d'alarme, ou des dispositifs de sécurité ou de limitation, ayant une fonction d'avertissement ou de protection en cas de défaillance ou de dysfonctionnement du M9106-xGx-2 Series actuator.

Mounting

The actuators are not position sensitive, and may be mounted in any convenient orientation. They may be installed on a 3/8 to 1/2 in. (10 to 12.7 mm) round shaft or a 3/8 in. (10 mm) square shaft, 1.7 in. (43 mm) or longer. If the shaft is less than 1.7 in. (43 mm), install an extension recommended by the damper manufacturer.
To mount the actuator, proceed as follows:
1. Press and hold the gear release lever, and rotate the coupler to the 0 or 90° position. Release the gear release lever. (See Figure 1.)

Parts Included

M9106-xGx-2 actuator
M9000-160 anti-rotation bracket
two No. 12-24 x 1/2 in. self-tapping hex
washer-head screws
spade terminals

Special Tools Needed

drill with a 3/16 in. (No. 15, 4.57 mm) drill bi t
5/16 in. (8 mm) square socket or 3/8 in.(10 mm)
12-point socket
wire/terminal crimper
© 2014 Johnson Controls, Inc. 1 Part No. 34-636-1085, Rev. D www.johnsoncontrols.com
Figure 1: Mounting Positions
Table 1: Distances from the Anti-rotation Bracket to the Shaft Center
“A” Dimensions 5-1/8 in. 5-1/16 in.
(See Figure 1.) 130 mm 128 mm
No. 12-24 Sheet
Metal Screws (2)
Cover
Screw
Slot for Bracket
Anti-rotation Bracket
Anti-rotation Bracket Tab
Damper
Frame
Damper
Damper
Shaft
Damper
Blade
CCW
to
Close
CW
to
Close
2. Bend or cut the anti-rotation bracket to fit t he damper frame or duct as shown in Figure 2.
Figure 2: Anti-rotation Bracket Positions
3. Close the damper.
4. Insert the anti-rotation bracket tab into the slot at the bottom of the actuator (shown in Figure 2), and slide the actuator onto the shaft.
5. Refer to the “A” Dimensions in Table 1 and Figure 1 to position the anti-rotation bracket tab midway in the actuator slot.
IMPORTANT: The anti-rotation bracket tab must be placed midway in the actuator slot to prevent actuator binding and premature wear.
6. Use the anti-rotation bracket as a guide, and drill the holes in the damper frame or duct for the bracket (based on the measurements obtained in Table 1 and Figure 1).
Note: When installing the actuator to a Johnson Controls damper, use the existing holes in the damper frame.
Note: Keep the actuator parallel to the mounting surface while tightening the set screw.
10. Press and hold the gear release lever, and turn the shaft by hand to ensure the damper rotates from its fully closed to fully open position.
11. Release the gear release lever.

Rotation Range

The damper must be checked as follows:
1. Make sure that the damper blade is visually accessible or its position is permanently m arked on the end of the damper shaft as shown in Figure 3.)
Figure 3: Damper Position Icons
2. Grasp the damper shaft firmly with a pliers and manually turn the damper to fully open.

90 Degrees

If the damper shaft rotation is 90°:
1. Press and hold the gear release lever shown in Figure 1, and rotate the actuator coupler and damper shaft to the fully closed position as shown in Figure 4.
7. Attach the anti-rotation bracket to the damper
IMPORTANT: Do not overtighten the mounting screws to avoid stripping the threads.
8. Secure the coupler to the shaft using a 5/16 in.
9. Continue tightening the coupler set screw to
2 M9106-xGx-2 Series Electric Non-Spring Return Actuators Installation Instructions
frame or duct with the two self-tapping screws provided, using a 1/4 in. (7 mm) flat-blade screwdriver or 5/16 in. (8 mm) nut driver.
(8 mm) square socket or 3/8 in. (10 mm) 12-point socket to tighten the coupler set screw again st the damper shaft. (See Figure 1.)
achieve a torque of 150 to 180 lb∙in
(17 to 20 N∙m).
Figure 4: Damper Rotation
2. Note the rotation travel (30 to 90°) and direction, either Clockwise (CW) or Counterclockwise (CCW), required to close the damper.
If rotation is less than 90°, proceed to the Less than 90 Degrees section.
3. Release the gear release lever.

Less than 90 Degrees

9
0
6
0
3
0
0
0
9
0
3
0
6
0
End-stops (2)
Coupler Set
Screw
Damper Shaft
End-stop
Set Screws
(2)
Stop Ge ar
CW
COM
CCW
If the damper shaft rotation is less than 90°, the rotation range of the actuator has to be adjusted with the scale on the actuator cover. (See Figure 5. )
Figure 5: Setting the Rotation Range
Use the center of the coupler set screw as a pointer to observe the position on the scale when rotat i ng the coupler from one side to the other.
Examples:
For a rotation range of 90°, move both end-stop set screws fully up as shown in Figure 5.
To set a rotation range of 60°, leave one end-stop set screw fully up, and adjust the other set scr ew so the coupler rotates between the 30 and 90° indicator marks on the scale.
For a rotation range of 45°, adjust both end-stop set screws so the coupler rotates between t he 30 and 75° indicator marks on the scale.
To set a rotation range of 30°, move both end-stop set screws so the coupler rotates between t he 30 and 60° indicator marks on the scale.
IMPORTANT: Do not remove the end-stop set screws, as this could interfere with the act uator’s operation.
4. Repeat Steps 1 through 3 to set the desired maximum rotation position.
5. Tighten both end-stop set screws to a minimum of 25 lbin (2.8 Nm).
6. Turn the actuator coupler and the damper shaft t o the minimum rotation position.

Setup and Adjustments

Direction of Action

In the Direct Acting (DA) mode, a minimum co ntrol signal drives the actuator to the full CCW position, and a maximum control signal drives it fully CW. Fo r Reverse Acting (RA) operation, a minimum cont rol signal drives the actuator to the full CW posit i on, and a maximum control signal drives it fully CCW. To set an actuator for RA, proceed to the appropriate se ct i on for the actuator model.

Floating Application: AGx and IGx Models

For CW rotation and RA operation, apply 24 VAC to the Common (COM) and CW Terminals. For CCW rotation and DA operation, apply 24 VAC to the COM and CCW Terminals. (See Figure 6.)
To accurately set the end stops:
1. Press and hold the gear release lever. Turn the actuator coupler to the minimum rotation posit ion for the minimum ventilation flow require d.
2. Release the gear release lever.
3. Use a No. 2 Phillips screwdriver to loosen the end-stop set screw on the actuator that is closest to the stop gear, and move it in its slot so it is tight against the stop gear. (See Figure 5.)
M9106-xGx-2 Series Electric Non-Spring Return Actuators Installat i on Instructions 3
Figure 6: Direction of Action on
AGx and IGx Model

On/Off Application: IGx Model Only

Drive the IGx model as an On/Off actuator by wiring continuous 24 VAC power to the COM and CW Terminals. At the same time, command the actuator to open by powering the CCW Terminal with 24 VAC. To drive the actuator back to the ful l CW position, remove the 24 VAC signal from the CCW Terminal.

GGx Models

(CW) DA
(CCW) RA
NC2 NO2 C2
C1
NC1
NO1
FB
VDC/mA
+24
COM
Jumper W3
Factory Set
VDC mA
Jumper W2
Jumper W1
Factory Set
Input
Input
0-10 VDC 0-20 mA
2-10 VDC 4-20 mA
Feedback
0-10 VDC
2-10 VDC
Direct Acting (DA)
Reverse Acting (RA)
Rotation Direction
with Inc re as ing Signal
Factory Set
Note: Jumper W1 is not available on the floating models.
Common +24 VAC Power VDC/mA Feedba c k O utp ut
NC2 NO2 C2
C
1
N
C
1
N
O
1
Time
(Minutes)
1.0
1.5
2.0
5.5
11.0
1.0
Off On
Off On
Off
On
A
B
C Off Off
Off
Off Off Off
On Off On On
On
On
Mode
Switch Settings
A B C
Note: The IGA models have Board 1, and the IG C models have both Board 1 and Board 2.
Board 1
Board 2
COM
CW
CCW
Off On
90°
90°
0.0V
2.0V
10.0V
8.7V
7.3V
6.0V
4.7V
3.3V
10.0V
8.3V
6.7V
5.0V
3.3V
1.7V
75°
75°
60°
60°
45°
45°
30°
30°
15°
15°
Rotation Range
2-10V
Feedback
0-10V
Feedback
Direct
Acting
10.0k
6.7k
1.7k
0
8.3k
0-10k ohm s
Feedback
5.0k
3.3k
Direct or
Reverse
Acting
2-10V
Feedback
Reverse
Acting
0-10V
Feedback
0.0V
1.7V
3.3V 5.0V
6.7V
8.3V
10.0V
10.0V
8.7V7.3V
6.0V4.7V
3.3V
2.0V
Set Screw
Adjustment
Set Screw
Adjustment
Note:
0-10k ohm s f eedback is avail able on AGF model s.
0-10V is available on GGA and GGC models.
The M9106-GGx-2 proportional actuators are factory set for Direct Acting (DA) mode with Jumper W1 in the DA position. Remove Jumper W1 and place it in the RA position. (See Figure 7.)
Figure 8: Mode Switch Settings on IGx Models
The 1-, 1.5-, and 2-minute settings are ideal for on/off and floating applications, and replace the M9104-xGx-2 1.5-minute models. The 5.5- and 11-minute settings are replacements for the 35 lb∙in (4 N∙m) EDA-2040 and the ATP-2040 models.
Figure 7: Calibrating the GGx Models

Jumpers (GGx Models)

The M9106-GGx-2 proportional actuators are factory set with Jumper W2 in the 0 to 10 VDC position and Jumper W3 in the VDC position.
The VDC/mA terminal is the control input signal. Jumper W3 must be in the VDC position for voltage input and in the mA position for current input. The FB Terminal is the feedback output. (See Figure 7.)

Mode Switches (IGx Models)

The M9106-IGx-2 models offer adjustable rotation times of 1, 1.5, 2, 5.5, and 11 minutes (factory set for 1 minute). Switch settings determine the rotat i on time of the IGx models. Refer to Figure 8 to position the mode switches for the desired rotation time.
4 M9106-xGx-2 Series Electric Non-Spring Return Actuators Installation Instructions
The feedback signal will vary with a change to the rotation range. For the GGA and GGC models, a change to the rotation range changes the feedback signal and the operating range proportionally. For the AGF model, resistance feedback is reduced corresponding to the reduced rotation range. (S ee Figure 9.)
Figure 9: Nominal Feedback Signal Rel ative to
the Rotation Range

Feedback Signal

Wiring

!
Proportional Control
Models: GGx
On-Off Control
Models: IGx
0-10 VDC
0-10 VDC
0-20 mA
+ +
FB
VDC/mA
+24
COM
24 VAC
-
<
~
Auxiliary Switches
Models: All xGC
Feedback Potent iometer
Model: AGF (0-10,000 ohms)
S1
C1
NC1
NO1
10°
S2
NC2 NO2
C2
80°
Floating Control
Models: AGx and I Gx
~
~
CCW
CCW
CW
CW
COM
COM
<
<
24 VAC
24 VAC
~
~
CW
0%
100%
CW
CCW
Wiper
Cover
Screw
Cover
Gear
Release
Plugs
(Conduit Openings)
CAUTION: Risk of Property Damage.
Do not apply power to the system before checking all wiring connections. Short circuited or improperly connected wires may result in permanent dam age to the equipment.
MISE EN GARDE: Risque de dégâts matériels.
Ne pas mettre le système sous tension avant d'avoir vérifié tous les raccords de câblage. Des fils formant un court-circuit ou connectés de façon incorrecte risquent d'endommager irrémédiablement l'équipement.
IMPORTANT: Make all wiring connections in accordance with the National Electrical Cod e and all local regulations.
The actuator requires a 24 VAC control signal and is compatible with a variety of controllers. (See Figure 10.)
Note: To avoid excessive wear or drive time on the motor for the AGx models, use a controller and/ or software that provides a time-out function to remove the signal at the end of rotation (stall). The G Gx and IGx models have an auto shutoff to avoid excessiv e wear or drive time on the motor.

Through the Conduit Openings

Depending on the M9106 model selected, one or both conduit openings are used.
1. Loosen the cover screw and remove the actuator cover.
2. Push the plastic conduit plug out of the conduit opening with fingertip. (See Figure 11.)
Figure 10: Wiring for M9106 Models
M9106-xGx-2 Series Electric Non-Spring Return Actuators Installat i on Instructions 5
Figure 11: Location of the Conduit Openings
3. Use the Phillips No. 1 screwdriver to puncture a hole through the center of the plastic conduit pl ug. Reinsert the plug into the conduit opening.
Note: For applications requiring metal conduit, thread the conduit fitting into the conduit opening and hand tighten.
4. Insert the cable wires through the plastic plug, compression fitting, or conduit fitt ing, and connect to the terminals using the appropriate wiring diagram in Figure 10.
IMPORTANT: Install all quick-connect terminals in the same direction to prevent shorti ng. (See Figure 12.)
Figure 12: Orientation of Terminals
Note: If using optional pluggable terminal blocks (M9000-105 or M9000-106), insert the cable wires through the conduit opening, and then connect t he wires to the terminals.
Edge of
Switch
Gear
Release
Plunger
Nodule G uides
(10° Increments)
CW
CW
Coupler
Set Screw
90°

Auxiliary Switches (xGC Models)

The M9106-xGC-2 models have two built-in auxiliary switches that may be set for any angle between 0 and 90° (factory set for 10 and 80°, nominal). Refer to the Technical Data section for auxiliary switch ratings.
The following procedures serve as examples to change the position of the auxiliary switch angles when starting at full CCW position.

Switch S1

To change the angle of Switch S1 to 20°, refer to Figure 13 and proceed as follows:
Figure 13: Switch Angle Settings
1. Press and hold the gear release. Using the 0 to 90° nodule guides, rotate the coupler until the center of the coupler set screw is at 20°.

Switch S2

To change the angle of Switch S2 to 70°, refer to Figure 13 and proceed as follows:
1. Press and hold the gear release. Using the 0 to 90° nodule guides, rotate the coupler until the center of the coupler set screw is at 70°.
2. Rotate Switch S2 CW, and align the edge of the switch with the plunger until the plunger rise s. (See Figure 13.)
Note: At this point, the normally closed contact opens, and the normally open contact closes. (S ee Auxiliary Switches in Figure 10.)
3. Press and hold the gear release. Rotate the coupler until the center of the coupler set screw is back to 0°.
4. Check all the wiring and system settings, and apply power to the controller. Provide signal s t o the actuator to drive it at least one complete cycle open and closed to verify proper operation.

Repairs and Replacement

Field repairs must not be made. For a replacement or an accessory, refer to the Ordering Information section in the M9106-xGx-2 Series Electric Non-spring Return Actuators Product Bulletin (LIT-2681123).
2. Rotate Switch S1 CW, and align the edge of the
Note: At this point, the normally closed contact closes, and the normally open contact opens. (S ee Auxiliary Switches in Figure 10.)
6 M9106-xGx-2 Series Electric Non-Spring Return Actuators Installation Instructions
switch with the plunger until the plunger rise s. (See Figure 13.)
Product
M9106-xGx-2 Series Electric Non-Spring Return Actuators
GGx: 20 to 30 VAC at 50/60 Hz; 3.2 VA supply, Class 2
Input Signal
GGx: 0 to 10 VDC or 0 to 20 mA
Action is jumper selectable Direct (CW) or Reverse (CCW) with signal increase.
GGx: Voltage Input, 150,000 ohms; Current Input, 500 ohms
Corresponds to input signal span selection
Auxiliary Switch Rating
1.5 A inductive, 3.0 A resistive, 35 V A maximum per switch, Class 2
(Running Torque)
5.5- and 11-minute settings: 35 lb∙in (4 N∙m)
Cycles
100,000 full cycles; 2,500,000 reposi tions rated at 53 lbin (6 N∙m)
Audible Noise Rating
35 dBA maximum at 1 m
Rotation Range
Adjustable from 30 to 90°, CW or CCW
All Other Models: Nominal 60 seconds at 60 Hz and 72 seconds at 50 Hz for 90°
Electrical Connection
1/4 in. spade terminals (Optional pluggable terminal blocks are available.)
Mechanical Connection
3/8 to 1/2 in. (10 to 12.7 mm) round shaft or 3/8 in. (10 mm) square shaft
Enclosure
NEMA 2, IP32
Conditions
Conditions
All Other Models: -40 to 176°F (-40 to 80°C); 90% RH maximum, non-condensing
Dimensions (H x W x D)
5.9 x 4.2 x 2.64 in. (150.1 x 106.5 x 67 mm)
Shipping Weight
2.4 lb (1.08 kg)
CE Mark, EMC Directive 89/336/EEC

Technical Data

Power Requirements AGx: 20 to 30 VAC at 50/60 Hz; 2.5 VA supply, Class 2
IGx: 20 to 30 VAC at 50/60 Hz; 2.8 VA supply, Class 2
AGx and IGx: 20 to 30 VAC at 50/60 Hz
Input Signal Adjustments AGx and IGx: CW and COM Terminals, CW rotation
CCW and COM Terminals, CCW rotation GGx (Voltage Input or Current Input): Jumper Selectable: 0 (2) to 10 VDC or 0 (4) to 20 mA Factory Setting: 0 to 10 VDC, CW rotation with signal increase
Input Impedance AGx: 200 ohms, nominal
IGx: 160 ohms, nominal
Feedback Signal AGF: 10,000 ohm potentiometer, 1 W
GGx: 0 to 10 VDC or 2 to 10 VDC for 90° (10 VDC at 1 mA)
xGC: Two Single-Pole, Double-Throw (SPDT) switches rated at 24 VAC,
Mechanical Output
Rotation Time IGx: Adjustable with switch set tings (Factory set for 1 minute. See
Ambient Operating
Ambient Storage
Agency Compliance UL 873 Listed, File E27734, CCN XAPX
1-, 1.5-, and 2-minute settings: 53 lb∙in (6 N∙m)
Figure 12.) 60, 90, 120, 330, or 660 seconds (1, 1.5, 2, 5.5 or 11 min.) at 60 Hz; and 72, 108, 144, 396, or 792 seconds (1.2, 1.8, 2.4, 6.6, or 13.2 mi nutes) at 50 Hz
-4 to 125°F (-20 to 52°C); 90% RH maximum, non-condensing
IGx: -40 to 186°F (-40 to 86°C); 90% RH maximum, non-condensing
CSA C22.2 No. 139 Certified, File LR 85083, Class 3221 02
The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
M9106-xGx-2 Series Electric Non-Spring Return Actuators Installat i on Instructions 7
Building Efficiency
507 E. Michigan Street, Milwaukee, WI 53202
Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.
All other marks herein are the marks of t heir respective owners. © 2014 Johnson Controls, Inc.
8 M9106-xGx-2 Series Electric Non-Spring Return Actuators Installation Instructions