JC-VSD FP Series
II Drives
Description
The Johnson Controls® VSD FP Series II
provides the advanced technology and
features of the Johnson Controls VSD Series
II with a Disconnect or Bypass in a factory
mount option. Either option is available in
NEMA 1 galvanized steel or NEMA 3R
painted product. The FP Series II
IntelliDisconnect comes with an enclosed
disconnect (fused or non-fused) and door
mounted operator. The FP Series II
IntelliPass offers a fused or non-fused
disconnect switch, a two contactor bypass
design, and door mounted controls.
Refer to the JC-VSD FP Series II Drives
Product Bulletin (LIT-12012081) for
important product information.
Features
• Network Connectivity for Drive and Bypass
(BACnet®, SA Bus, N2, and LON) —
allows for compatibility with current and
future Johnson Controls network
architecture
• Software parameters that utilize
engineering units common to the HVAC
industry — allow for quick and easy
startup using the onboard startup wizard
with engineering units transmitted over a
communications bus
• Johnson Controls Support That Includes
Ordering, Estimating, and Project
Management Tools: Advanced Order
Management System (AOMS), Advanced
Installation Management (AIM) Tools QuickLIT, Catalog, PRESTO, and
STORE— allows users to easily identify
and order products
• Closed-Loop Control Programmed with
Engineering Units for Specific HVAC
Applications:
pump— provides software parameters
using engineering units common to the
HVAC industry
• Standard TYPE 12 Keypad on all Drives
with Copy and Paste Function; Capable of
Monitoring Three Parameters
Simultaneously — allows easy transfer of
parameter settings from one drive to
another drive
• Drive Programming Capability Using
Auxiliary
— allows variable speed drive
programming (including network
communication validation) prior to wiring
3-phase power to the drive
Standard, PID, or multi-
24 V Power
Supply
(VS-AUX24V)
Additional FP Series II Features
• NEMA 1 or NEMA 3R designs
• Temperature range of -10°C to 40°C (14°
to 104°F)
• OSHPD Certified
• Plenum rated
• Fused or Non-fused disconnect designs
with handle lockable in Off position
• EMI/RFI Filters standard on all drives
• I/O and communication cards provide
plug-and-play functionality
• Active Energy Control on-board all drives
to minimize energy losses and provide
industry leading efficiency
• Real Time Clock supporting calendaring
and PLC functionality
• Thin metal capacitor design for efficient
drive operation and extended life
• Standard DC link choke wit h MOVs for
enhanced transient and harmonic
distortion protection
• Top and bottom conduit entry for ease of
installation
• Copy and paste keypad function that
allows you to transfer parameter settings
from one drive to another
• Keypad that displays up to nine
monitored parameters simultaneously
• Standard TYPE12 keypad on all drives
• Simplified operating menu allows for
quick programming changes
• Anti-trip DC bus regulation
• Onboard RS-485 Communications
(BACnet, N2, Modbus®)
• Onboard Ethernet-based communications
(BACnet/IP, Modbus/TCP)
• SA bus communication factory installed
option
• Standard I/O: 6DI, 2AI, 1 AO , 1 Form C
RO (NO/NC),
• Short circuit withstand rating of 100kAIC
(additional fuses required for non-fused
disconnect designs)
• Input surge protection against voltage
spikes (varistor input)
• Hard-wired external/damper interlock
• Accommodates a wide variety of
expander boards and adapter boards
• Control logic can be powered from an
external auxiliary control panel
• Robust steel enclosure for simple
installation
FP Series II Drive with
IntelliPass and
IntelliDisconnect
Additional FP Series II IntelliPass
Only Features
• HAND/OFF/AUTO and
DRIVE/OFF/BYPASS sel ect or on keypad
that simplifies control
• 2 contactor bypass with drive isolation
switch
• Control power transformer with primary and
secondary fusing
• Bypass can be controlled mechanically,
electronically, and via SA Bus
Repair Information
If the FP Series II Drive fails to operate within
its specifications, contact the nearest
Johnson Controls representative.
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2015 Johnson Controls, Inc.
460V 3-Phase (YK pr o d uct )
208V, 230V 3-Phase (YK product )
200-240V 3-Phase (YM product)
380-480V 3-Phase (YM product)
1 = 208V (YK only) 6 = 200-240V (YM only)
1 = Non-fused Intell iDi sco nnect 3 = IntelliPass w/ Fused Disconnect
1 = 230V 3-phase Int ell iP ass only
YK = VSD Series II Base Drive
JC-VSD FP Series II Drives (Continued)
Catalog Number Selection
Issued July 1, 2015
YM = VSM Drive
4D8 = 4.8 Amp, 0.75kW (1 Hp)
8D0 = 8.0 Amp, 1.5 kW (2 Hp)
011 = 11 Amp, 2.2 kW (3 Hp)
016 = 16 Amp, 4.0 kW (5 Hp)
018 = 18 Amp, 4.0 kW (5 Hp)
024 = 24 Amp, 5.5 kW (7.5 Hp)
025 = 25 Amp, 5.5 kW (7.5 Hp)
031 = 31 Amp, 7.5 kW (10 Hp)
048 = 48 Amp, 11 kW (15 Hp)
062 = 62 Amp, 15 kW (20 Hp)
070 = 70 Amp, 18.5 kW (25 Hp)
075 = 75 Amp, 18.5 kW (25 Hp)
088 = 88 Amp, 22 kW (30 Hp)
115 = 115 Amp, 37 kW (40 Hp)
140 = 140 Amp, 37 kW (40 Hp)
150 = 150 Amp, 45 kW (50 Hp)
170 = 170 Amp, 45 kW (50 Hp)
2D8 = 2.8 Amp, 0.37 kW (0.5 Hp)
3D7 = 3.7 Amp, 0.55 kW (0.75 Hp)
4D8 = 4.8 Amp, 0.75 kW (1 Hp)
7D0 = 7.0 Amp, 1.1 kW (1.5 Hp)
1
1
1
1
1
2D4 = 2.4 Amp, 1.1 kW (1 Hp)
3D4 = 3.4 Amp, 1.1 kW (1 Hp)
4D0 = 4.0 Amp, 1.5 kW (2 Hp)
4D8 = 4.8 Amp, 1.5 kW (2 Hp)
5D6 = 5.6 Amp, 2.2 kW (3 Hp)
9D0 = 9.0 Amp, 4.0 kW (5 Hp)
9D6 = 9.6 Amp, 4.0 kW (5 Hp)
012 = 12 Amp, 5.5 kW (7.5 Hp)
016 = 16 Amp, 7.5 kW (10 Hp)
023 = 23 Amp, 11 kW (15 Hp)
031 = 31 Amp, 15 kW (20 Hp)
038 = 38 Amp, 18.5 kW (25 Hp)
046 = 46 Amp, 22 kW (30 Hp)
061 = 61 Amp, 30 kW (40 Hp)
070 = 70 Amp, 30 kW (50 Hp)
072 = 72 Amp, 37 kW (50 Hp)
080 = 80 Amp, 45 kW (60 Hp)
087 = 87 Amp, 45 kW (60 Hp)
105 = 105 Amp, 55 kW (75 Hp)
140 = 140 Amp, 75 kW (100 Hp)
170 = 170 Amp, 90 kW (125 Hp)
1D3 = 1.3 Amp, 0.37 kW (0.5 Hp)
1D9 = 1.9 Amp, 0.55 kW (0.75 Hp)
2D4 = 2.4 Amp, 0.75 kW (1 Hp)
3D3 = 3.3 Amp, 1.1 kW (1.5 Hp)
4D3 = 4.3 Amp, 1.5 kW (2 Hp)
2
2
2
2
2
2
2 = 230V (YK only) 7 = 380-480V (YM only)
4 = 460V (YK only)
2 = NEMA Type 3R (YK only)
2 = Fused IntelliDisconnect3 4 = IntelliPass w/ Non-fused Disconnect
2 = 460V 3-phase Int ell iP ass only
3 = Fused Disconnect is only option for YM product