Allows for compatibility with current and future Johnson Controls
Software Parameters That Utilize Engineering
Allow for quick and easy startup using the onboard startup wizard with
Johnson Controls Support That Includes
Allows users to easily identify and order products.
Closed-Loop Control Programmed with
Provides software parameters using engineering units common to the
Standard TYPE 12 Keypad on all Drives with
Allows easy transfer of parameter settings from one drive to another
Drive Programming Capability Using Auxiliary
Allows variable speed drive programm ing (including network
Product Bulletin
The Johnson Controls® VSD FP Series II provides the
advanced technology and features of the
Johnson Controls VSD Series II with a Disconnect or
Bypass in a factory mount option. Either opt ion is
available in NEMA 1 galvanized steel or NEMA 3R
painted product. The FP Series II IntelliDisconnect
comes with an enclosed disconnect (fused or nonfused) and door mounted operator. The FP Series II
IntelliPass offers a fused or non-fused disconnect
switch, a two contactor bypass design, and door
mounted controls.
Table 1: Features and Benefits
Refer to the QuickLIT website for the most up-to-date version of this document.
Code No. LIT-12012081
Issued July 1,
Figure 1: FP Series II Drives
2015
(BACnet®, SA Bus, N2, and LON)
Units Common to the HVAC Industry
Ordering, Estimating, and Project Management
Tools: Advanced Order Management System
(AOMS), Advanced Installation Management
(AIM) Tools - QuickLIT, Catalog, PRESTO, and
STORE
Engineering Units for Specific HVAC
Applications: Standard, PID, or multi-pump
Copy and Paste Function; Capable of
Monitoring Three Parameters Simultaneously
24 V Power Supply (VS-AUX24V)
network architecture.
engineering units transmitted over a communications bus.
HVAC industry.
drive.
communication validation) prior to wiring 3-phase power to the drive.
JC-VSD FP Series II Drives Product Bulletin 1
2
VSD FP Series II Drives Product Bulletin
Additional FP Series II Features
IMPORTANT: Use this FP Series II Drive only
• NEMA 1 or NEMA 3R designs
• Temperature range of -10°C to 40°C
(14° to 104°F)
• OSHPD Certified
• Plenum rated
• Fused or Non-fused disconnect
designs with handle lockable in Off
position
• EMI/RFI Filters standard on all drives
• I/O and communication cards provide
plug-and-play functionality
• Active Energy Control on-board all
drives to minimize energy losses and
provide industry leading efficiency
• Real Time Clock supporting
calendaring and PLC functionality
• Thin metal capacitor design for
efficient drive operation and extended
life
• Standard DC link choke and MOVs for
enhanced transient and harmonic
distortion protection
• Top and bottom conduit entry for ease
of installation
• Copy and paste keypad function that
allows you to transfer parameter
settings from one drive to another
• Keypad that displays up to nine
monitored parameters simultaneously
• Standard TYPE12 keypad on all
drives
• Simplified operating menu allows for
quick programming changes
• Standard I/O: 6DI, 2AI, 1AO, 1 Form C
RO (NO/NC),
• Short circuit withstand rating of
15kAIC (additional fuses required for
non-fused disconnect designs)
• Input surge protection against voltage
spikes (varistor input)
• Hard-wired external/damper interlock
• Accommodates a wide variety of
expander boards and adapter boards
• Control logic can be powered from an
external auxiliary control panel
• Robust steel enclosure for simple
installation
Additional FP Series II IntelliPass Only
Features
• HAND/OFF/AUTO and DRIVE/OFF/BYPASS
selector on keypad that simplifies control
• 2 contactor bypass with drive isolation switch
• Control power transformer with primary and
secondary fusing
• Bypass can be controlled mechanically,
electronically, and via SA Bus
as an operating control. Where failure or
malfunction of the Series II open drive could
lead to personal injury or property damage to
the controlled equipment or other property,
additional precautions must be designed into
the control system. Incorporate and maintain
other devices, such as supervisory or alarm
systems or safety or limit controls, intended to
warn of or protect against failure or malfunction
of the Series II open drive.
Table 2: F P Series II Micro Drive with Fused Disconnect NEMA Type 1 – 200-240V
Code Number hp
1
Frame Enclosure Rating
YM4D8612B-00000
1. All horsepower and current ratings are Variable Torque (VT).
Table 3: FP Series II Micro Drive with Fused Disconnect NEMA Type 1 – 380-480V
Code Number hp
1. All horsepower and current ratings are Variable Torque (VT).
1
Frame Enclosure Rating
VSD FP Series II Drives Product Bulletin
5
FP Series II Drives Product Selection
Table 4: FP Series II IntelliDisconnect NEMA Type 1 - 208V Fused
Code Number
YK4D8112B-00000 1 hp (0.75 kW) 4.8 A1 NEMA Type 1
YK8D0112B-00000 2 hp (1.5 kW) 8 A1 NEMA Type 1
YK011112B-00000 3 hp (2.2 kW) 11 A1 NEMA Type 1
YK018112B-00000 5 hp (4 kW) 18 A1 NEMA Type 1
YK025112B-00000 7.5 hp (5.5 kW) 25 A2 NEMA Type 1
YK031112B-00000 10 hp (7.5 kW) 31 A2 NEMA Type 1
YK048112B-00000 15 hp (11 kW) 48 A3 NEMA Type 1
YK062112B-00000 20 hp (15 kW) 62 A3 NEMA Type 1
YK075112B-00000 25 hp (18.5 kW) 75 A4 NEMA Type 1
YK088112B-00000 30 hp (22 kW) 88 A4 NEMA Type 1
YK140112B-00000 40 hp (37 kW) 140 A4 NEMA Type 1
YK170112B-00000 50 hp (45 kW) 170 A6 NEMA Type 1
1. For non-fused disconnect, change the 8th digit to a 1.
2. All horsepower and current ratings are Variable Torque (VT).
1
hp (kW)
2
Current (A)
Frame Enclosure Rating
Table 5: FP Series II IntelliDisconnect NEMA Type 3R - 208V Fused
Code Number
YK4D8122B-00000 1 hp (0.75 kW) 4.8 C1 NEMA Type 3R
YK8D0122B-00000 2 hp (1.5 kW) 8 C1 NEMA Type 3R
YK011122B-00000 3 hp (2.2 kW) 11 C1 NEMA Type 3R
YK018122B-00000 5 hp (4 kW) 18 C1 NEMA Type 3R
YK025122B-00000 7.5 hp (5.5 kW) 25 C2 NEMA Type 3R
YK031122B-00000 10 hp (7.5 kW) 31 C2 NEMA Type 3R
YK048122B-00000 15 hp (11 kW) 48 C3 NEMA Type 3R
YK062122B-00000 20 hp (15 kW) 62 C3 NEMA Type 3R
YK075122B-00000 25 hp (18.5 kW) 75 C4 NEMA Type 3R
YK088122B-00000 30 hp (22 kW) 88 C4 NEMA Type 3R
YK140122B-00000 40 hp (37 kW) 140 C4 NEMA Type 3R
YK170122B-00000 50 hp (45 kW) 170 C6 NEMA Type 3R
1. For non-fused disconnect, change the 8th digit to a 1.
2. All horsepower and current ratings are Variable Torque (VT).
1
hp (kW)
2
Current (A)
Frame Enclosure Rating
6
VSD FP Series II Drives Product Bulletin
Table 6: FP Series II IntelliDisconnect NEMA Type 1 - 230V Fused
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
Code Number
1
hp (kW)
2
Current (A)
Frame Enclosure Rating
YK4D8212B-00000 1 hp (0.75 kW) 4.8 A1
YK8D0212B-00000 2 hp (1.5 kW) 8 A1
YK011212B-00000 3 hp (2.2 kW) 11 A1
YK018212B-00000 5 hp (4 kW) 18 A1
YK025212B-00000 7.5 hp (5.5 kW) 25 A2
YK031212B-00000 10 hp (7.5 kW) 31 A2
YK048212B-00000 15 hp (11 kW) 48 A3
YK062212B-00000 20 hp (15 kW) 62 A3
YK075212B-00000 25 hp (18.5 kW) 75 A4
YK088212B-00000 30 hp (22 kW) 88 A4
YK140212B-00000 40 hp (37 kW) 140 A4
YK170212B-00000 50 hp (45 kW) 170 A6
1. For non-fused disconnect, change the 8th digit to a 1.
2. All horsepower and current ratings are Variable Torque (VT).
Table 7: FP Series II IntelliDisconnect NEMA Type 3R - 230V Fused
Code Number
1
hp (kW)
2
Current (A)
Frame Enclosure Rating
YK4D8222B-00000 1 hp (0.75 kW) 4.8 C1 NEMA Type 3R
YK8D0222B-00000 2 hp (1.5 kW) 8 C1 NEMA Type 3R
YK011222B-00000 3 hp (2.2 kW) 11 C1 NEMA Type 3R
YK018222B-00000 5 hp (4 kW) 18 C1 NEMA Type 3R
YK025222B-00000 7.5 hp (5.5 kW) 25 C2 NEMA Type 3R
YK031222B-00000 10 hp (7.5 kW) 31 C2 NEMA Type 3R
YK048222B-00000 15 hp (11 kW) 48 C3 NEMA Type 3R
YK062222B-00000 20 hp (15 kW) 62 C3 NEMA Type 3R
YK075222B-00000 25 hp (18.5 kW) 75 C4 NEMA Type 3R
YK088222B-00000 30 hp (22 kW) 88 C4 NEMA Type 3R
YK140222B-00000 40 hp (37 kW) 140 C4 NEMA Type 3R
YK170222B-00000 50 hp (45 kW) 170 C6 NEMA Type 3R
1. For non-fused disconnect, change the 8th digit to a 1.
2. All horsepower and current ratings are Variable Torque (VT).
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.