Johnson Controls JC-VSD FP Series II Drives Data Sheet

JC-VSD FP Series II Drives
Features
Benefits
Network Connectivity for Drive and Bypass
Allows for compatibility with current and future Johnson Controls
Software Parameters That Utilize Engineering
Allow for quick and easy startup using the onboard startup wizard with
Johnson Controls Support That Includes
Allows users to easily identify and order products.
Closed-Loop Control Programmed with
Provides software parameters using engineering units common to the
Standard TYPE 12 Keypad on all Drives with
Allows easy transfer of parameter settings from one drive to another Drive Programming Capability Using Auxiliary
Allows variable speed drive programm ing (including network
Product Bulletin
The Johnson Controls® VSD FP Series II provides the advanced technology and features of the Johnson Controls VSD Series II with a Disconnect or Bypass in a factory mount option. Either opt ion is available in NEMA 1 galvanized steel or NEMA 3R painted product. The FP Series II IntelliDisconnect comes with an enclosed disconnect (fused or non­fused) and door mounted operator. The FP Series II IntelliPass offers a fused or non-fused disconnect switch, a two contactor bypass design, and door mounted controls.
Table 1: Features and Benefits
Refer to the QuickLIT website for the most up-to-date version of this document.
Code No. LIT-12012081
Issued July 1,
Figure 1: FP Series II Drives
2015
(BACnet®, SA Bus, N2, and LON)
Units Common to the HVAC Industry
Ordering, Estimating, and Project Management Tools: Advanced Order Management System (AOMS), Advanced Installation Management (AIM) Tools - QuickLIT, Catalog, PRESTO, and STORE
Engineering Units for Specific HVAC Applications: Standard, PID, or multi-pump
Copy and Paste Function; Capable of Monitoring Three Parameters Simultaneously
24 V Power Supply (VS-AUX24V)
network architecture.
engineering units transmitted over a communications bus.
HVAC industry.
drive.
communication validation) prior to wiring 3-phase power to the drive.
JC-VSD FP Series II Drives Product Bulletin 1
2
VSD FP Series II Drives Product Bulletin
Additional FP Series II Features
IMPORTANT: Use this FP Series II Drive only
NEMA 1 or NEMA 3R designs
Temperature range of -10°C to 40°C (14° to 104°F)
OSHPD Certified
Plenum rated
Fused or Non-fused disconnect designs with handle lockable in Off position
EMI/RFI Filters standard on all drives
I/O and communication cards provide plug-and-play functionality
Active Energy Control on-board all drives to minimize energy losses and provide industry leading efficiency
Real Time Clock supporting calendaring and PLC functionality
Thin metal capacitor design for efficient drive operation and extended life
Standard DC link choke and MOVs for enhanced transient and harmonic distortion protection
Top and bottom conduit entry for ease of installation
Copy and paste keypad function that allows you to transfer parameter settings from one drive to another
Keypad that displays up to nine monitored parameters simultaneously
Standard TYPE12 keypad on all drives
Simplified operating menu allows for quick programming changes
Anti-trip DC bus regulation
Onboard RS-485 Communications (BACnet, N2, Modbus®)
Onboard Ethernet-based communications (BACnet/IP, Modbus/TCP)
SA Bus factory installed communications option
Standard I/O: 6DI, 2AI, 1AO, 1 Form C RO (NO/NC),
Short circuit withstand rating of 15kAIC (additional fuses required for non-fused disconnect designs)
Input surge protection against voltage spikes (varistor input)
Hard-wired external/damper interlock
Accommodates a wide variety of expander boards and adapter boards
Control logic can be powered from an external auxiliary control panel
Robust steel enclosure for simple installation
Additional FP Series II IntelliPass Only Features
• HAND/OFF/AUTO and DRIVE/OFF/BYPASS selector on keypad that simplifies control
• 2 contactor bypass with drive isolation switch
• Control power transformer with primary and secondary fusing
• Bypass can be controlled mechanically, electronically, and via SA Bus
as an operating control. Where failure or malfunction of the Series II open drive could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the Series II open drive.
VSD FP Series II Drives Product Bulletin
3
Catalog Number Selection
460V 3-Phase (YK pr o d uct )
208V, 230V 3-Phase (YK product )
200-240V 3-Phase (YM product)
380-480V 3-Phase (YM product)
1 = 208V (YK only) 6 = 200-240V (YM only) 4 = 460V (YK only)
Base Product
Amps, kW, Hp
Voltage
Enclosure Style
Separator
Options
1 = NEMA Type 1
1 = Non-fused Intell iDi sco nnect 3 = IntelliPass w/ Fused Disconnect
1 = 230V 3-phase Bypass only
B = Rev 2 (Americas)
00000 = No options
YK = VSD Series II Base Drive YM = VSM Drive
Catalog Number
Y
K 4 D
8
4
1
1
B
0
0
0
0
VSD Series II Enclosed Drives Selection Chart
4D8 = 4.8 Amp, 0.75kW (1 Hp) 8D0 = 8.0 Amp, 1.5 kW (2 Hp) 011 = 11 Amp, 2.2 kW (3 Hp) 016 = 16 Amp, 4.0 kW (5 Hp) 018 = 18 Amp, 4.0 kW (5 Hp) 024 = 24 Amp, 5.5 kW (7.5 Hp) 025 = 25 Amp, 5.5 kW (7.5 Hp) 031 = 31 Amp, 7.5 kW (10 Hp) 048 = 48 Amp, 11 kW (15 Hp) 062 = 62 Amp, 15 kW (20 Hp) 070 = 70 Amp, 18.5 kW (25 Hp) 075 = 75 Amp, 18.5 kW (25 Hp) 088 = 88 Amp, 22 kW (30 Hp) 115 = 115 Amp, 37 kW (40 Hp) 140 = 140 Amp, 37 kW (40 Hp) 150 = 150 Amp, 45 kW (50 Hp) 170 = 170 Amp, 45 kW (50 Hp)
2D8 = 2.8 Amp, 0.37 kW (0.5 Hp) 3D7 = 3.7 Amp, 0.55 kW (0.75 Hp) 4D8 = 4.8 Amp, 0.75 kW (1 Hp) 7D0 = 7.0 Amp, 1.1 kW (1.5 Hp)
2 = 230V (YK only) 7 = 380-480V (YM only)
1
1
1
1
1
2D4 = 2.4 Amp, 1.1 kW (1 Hp) 3D4 = 3.4 Amp, 1.1 kW (1 Hp) 4D0 = 4.0 Amp, 1.5 kW (2 Hp) 4D8 = 4.8 Amp, 1.5 kW (2 Hp) 5D6 = 5.6 Amp, 2.2 kW (3 Hp) 9D0 = 9.0 Amp, 4.0 kW (5 Hp) 9D6 = 9.6 Amp, 4.0 kW (5 Hp) 012 = 12 Amp, 5.5 kW (7.5 Hp) 016 = 16 Amp, 7.5 kW (10 Hp) 023 = 23 Amp, 11 kW (15 Hp) 031 = 31 Amp, 15 kW (20 Hp) 038 = 38 Amp, 18.5 kW (25 Hp) 046 = 46 Amp, 22 kW (30 Hp) 061 = 61 Amp, 30 kW (40 Hp) 070 = 70 Amp, 30 kW (50 Hp) 072 = 72 Amp, 37 kW (50 Hp) 080 = 80 Amp, 45 kW (60 Hp) 087 = 87 Amp, 45 kW (60 Hp) 105 = 105 Amp, 55 kW (75 Hp) 140 = 140 Amp, 75 kW (100 Hp) 170 = 170 Amp, 90 kW (125 Hp)
1D3 = 1.3 Amp, 0.37 kW (0.5 Hp) 1D9 = 1.9 Amp, 0.55 kW (0.75 Hp) 2D4 = 2.4 Amp, 0.75 kW (1 Hp) 3D3 = 3.3 Amp, 1.1 kW (1.5 Hp) 4D3 = 4.3 Amp, 1.5 kW (2 Hp)
2
2
2
2
2
2
Rating
2 = 460V 3-phase Bypass only 3 = Fused Disconnect is only option for YM product
2 = NEMA Type 2 (YK only)
2 = Fused IntelliDisconn ect3 4 = IntelliPass w/ Non-fused Disconnect
4
VSD FP Series II Drives Product Bulletin
FP Series II Micro Drives Product Selection
Current (A)
YM2D8612B-00000
0.5 hp
2.8
M1
NEMA Type 1
YM3D7612B-00000
0.75 hp
3.7
M1
NEMA Type 1
1 hp
4.8
M1
NEMA Type 1
YM7D0612B-00000
1.5 hp
7
M1
NEMA Type 1
Current (A)
YM1D3712B-00000
0.5 hp
1.3
M1
NEMA Type 1
YM1D9712B-00000
0.75 hp
1.9
M1
NEMA Type 1
YM2D4712B-00000
1 hp
2.4
M1
NEMA Type 1
YM3D3712B-00000
1.5 hp
3.3
M1
NEMA Type 1
YM4D3712B-00000
2 hp
4.3
M1
NEMA Type 1
Table 2: F P Series II Micro Drive with Fused Disconnect NEMA Type 1 – 200-240V
Code Number hp
1
Frame Enclosure Rating
YM4D8612B-00000
1. All horsepower and current ratings are Variable Torque (VT).
Table 3: FP Series II Micro Drive with Fused Disconnect NEMA Type 1 – 380-480V
Code Number hp
1. All horsepower and current ratings are Variable Torque (VT).
1
Frame Enclosure Rating
VSD FP Series II Drives Product Bulletin
5
FP Series II Drives Product Selection
Table 4: FP Series II IntelliDisconnect NEMA Type 1 - 208V Fused
Code Number
YK4D8112B-00000 1 hp (0.75 kW) 4.8 A1 NEMA Type 1 YK8D0112B-00000 2 hp (1.5 kW) 8 A1 NEMA Type 1 YK011112B-00000 3 hp (2.2 kW) 11 A1 NEMA Type 1 YK018112B-00000 5 hp (4 kW) 18 A1 NEMA Type 1 YK025112B-00000 7.5 hp (5.5 kW) 25 A2 NEMA Type 1 YK031112B-00000 10 hp (7.5 kW) 31 A2 NEMA Type 1 YK048112B-00000 15 hp (11 kW) 48 A3 NEMA Type 1 YK062112B-00000 20 hp (15 kW) 62 A3 NEMA Type 1 YK075112B-00000 25 hp (18.5 kW) 75 A4 NEMA Type 1 YK088112B-00000 30 hp (22 kW) 88 A4 NEMA Type 1 YK140112B-00000 40 hp (37 kW) 140 A4 NEMA Type 1 YK170112B-00000 50 hp (45 kW) 170 A6 NEMA Type 1
1. For non-fused disconnect, change the 8th digit to a 1.
2. All horsepower and current ratings are Variable Torque (VT).
1
hp (kW)
2
Current (A)
Frame Enclosure Rating
Table 5: FP Series II IntelliDisconnect NEMA Type 3R - 208V Fused
Code Number
YK4D8122B-00000 1 hp (0.75 kW) 4.8 C1 NEMA Type 3R YK8D0122B-00000 2 hp (1.5 kW) 8 C1 NEMA Type 3R YK011122B-00000 3 hp (2.2 kW) 11 C1 NEMA Type 3R YK018122B-00000 5 hp (4 kW) 18 C1 NEMA Type 3R YK025122B-00000 7.5 hp (5.5 kW) 25 C2 NEMA Type 3R YK031122B-00000 10 hp (7.5 kW) 31 C2 NEMA Type 3R YK048122B-00000 15 hp (11 kW) 48 C3 NEMA Type 3R YK062122B-00000 20 hp (15 kW) 62 C3 NEMA Type 3R YK075122B-00000 25 hp (18.5 kW) 75 C4 NEMA Type 3R YK088122B-00000 30 hp (22 kW) 88 C4 NEMA Type 3R YK140122B-00000 40 hp (37 kW) 140 C4 NEMA Type 3R YK170122B-00000 50 hp (45 kW) 170 C6 NEMA Type 3R
1. For non-fused disconnect, change the 8th digit to a 1.
2. All horsepower and current ratings are Variable Torque (VT).
1
hp (kW)
2
Current (A)
Frame Enclosure Rating
6
VSD FP Series II Drives Product Bulletin
Table 6: FP Series II IntelliDisconnect NEMA Type 1 - 230V Fused
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
NEMA Type 1
Code Number
1
hp (kW)
2
Current (A)
Frame Enclosure Rating
YK4D8212B-00000 1 hp (0.75 kW) 4.8 A1 YK8D0212B-00000 2 hp (1.5 kW) 8 A1 YK011212B-00000 3 hp (2.2 kW) 11 A1 YK018212B-00000 5 hp (4 kW) 18 A1 YK025212B-00000 7.5 hp (5.5 kW) 25 A2 YK031212B-00000 10 hp (7.5 kW) 31 A2 YK048212B-00000 15 hp (11 kW) 48 A3 YK062212B-00000 20 hp (15 kW) 62 A3 YK075212B-00000 25 hp (18.5 kW) 75 A4 YK088212B-00000 30 hp (22 kW) 88 A4 YK140212B-00000 40 hp (37 kW) 140 A4 YK170212B-00000 50 hp (45 kW) 170 A6
1. For non-fused disconnect, change the 8th digit to a 1.
2. All horsepower and current ratings are Variable Torque (VT).
Table 7: FP Series II IntelliDisconnect NEMA Type 3R - 230V Fused
Code Number
1
hp (kW)
2
Current (A)
Frame Enclosure Rating
YK4D8222B-00000 1 hp (0.75 kW) 4.8 C1 NEMA Type 3R YK8D0222B-00000 2 hp (1.5 kW) 8 C1 NEMA Type 3R YK011222B-00000 3 hp (2.2 kW) 11 C1 NEMA Type 3R YK018222B-00000 5 hp (4 kW) 18 C1 NEMA Type 3R YK025222B-00000 7.5 hp (5.5 kW) 25 C2 NEMA Type 3R YK031222B-00000 10 hp (7.5 kW) 31 C2 NEMA Type 3R YK048222B-00000 15 hp (11 kW) 48 C3 NEMA Type 3R YK062222B-00000 20 hp (15 kW) 62 C3 NEMA Type 3R YK075222B-00000 25 hp (18.5 kW) 75 C4 NEMA Type 3R YK088222B-00000 30 hp (22 kW) 88 C4 NEMA Type 3R YK140222B-00000 40 hp (37 kW) 140 C4 NEMA Type 3R YK170222B-00000 50 hp (45 kW) 170 C6 NEMA Type 3R
1. For non-fused disconnect, change the 8th digit to a 1.
2. All horsepower and current ratings are Variable Torque (VT).
Loading...